UNI EN ISO EN

Similar documents
P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Control block VOFA with safety function

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Redundant Control System

4 Redundant Control System

Ex m Solenoid Operator Type 0519

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Tina 4A Connection block

EStrong-series Emergency Stop

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Tina 11A Connection block

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue. Issue 1

Valves and Solenoid valves Series E 2/

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Tina 10A/B/C Adaptor unit

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

2/2 Solenoid Cartridge Valve, Size 10

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

Operating Manual for the RE-19 Multi-pin Valve Terminal

ME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.

Pumps and pumping units SL i & Micro C

Type Electronic Limit Switch

Short form catalogue ATEX certified products

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

ZB0050 / ZB0051 ZB0070 / ZB0071

Safety Sensor CSS 180 Product Information

ENGINE PROTECTION BOARD PDM1

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Safety valves direct, pilot operated and cartridge execution

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue

Sense7-series Non-contact coded safety switch

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Session Four Applying functional safety to machine interlock guards

Operating instructions Solenoid interlock AZM About this document. Content

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Sensor boxes SRBE Key features and product range overview

Operating Instructions

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

Series 3730 Electropneumatic Positioner Type

FMC-1/2 Tina Muting unit

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

CETOP POSITION PAPER PP 07

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Electronic Limit Switch Type

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Smile 41 Push-button box with/without emergency stop

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Safety Valve HM-SV Installation, maintenance and startup guide

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

INTEGRATED HYDRAULIC BRAKE ACTUATORS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

HIGH POWER SOLENOID DRIVER 1

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

D Series Ex d Stainless Steel

Solenoid valves VUVS/valve manifold VTUS, NPT

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Contents. Part no.: MLC510R Safety light curtain receiver

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

MACH 16 VALVES DISTRIBUTORS

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

DISTRIBUTORS. n o p q. hdm + multi-pole connection TECHNICAL DATA COMPONENTS

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

MONITORED HYDRAULIC VALVE SYSTEMS

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Safety Exhaust Valve Integration Guide

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

WATERFLUX 3070 Quick Start

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

CCAI, CCAIF, CCAIF..H

Material pressure (bar) (Cv (US) kv x 1,2 Seat

USER INSTRUCTIONS FOR SLIDING DOORS

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

ECONOMISER SERIES E2T USER MANUAL

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Explosion-Protected Pressure Switches

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Transcription:

Airplus Safeline

eneral Upon implementation of the AIRPLUS T series, air-treatment units, PNEUMAX develops a supply and discharge valve, with an electropneumatic control and spring-return, fitted with a diagnostic system regarding the state of the valve, with the possibility of creating a double channel to determine the system s redundancy. The valve, as a safety feature, provides the interruption of the air supply and the exhaust of the air circuit it is connected to. The version with one single channel emphasises the features of an EV / NC, monostable with electropneumatic control and spring-return, whose operation involves: - condition of the VALVE AT REST, with a DE-ENERISED coil; Port (air supply) is not been connected to Port (downstream air circuit). Port is discharged out of Port ; - condition of the VALVE ACTIVATED, with an ENERISED coil; Port (air supply) is connected to Port (downstream air circuit), with Port (Discharge) closed. By de-energising the coil, the system resets the condition of VALVE AT REST by means of the return spring, which repositions the spool. Once again Port (downstream air circuit), discharges via Port. The state of the valve is constantly monitored by a diagnostic system, using a Hall effect sensor, which reads the position of the spool and consequently takes note of the valve s position. The sensor is in the ON position when the valve is at rest (DE-ENERISED coil), while it is in the OFF position when the valve is activated (ENERISED coil). The sensor is in the OFF position under conditions of an activated valve (DE-ENERISED coil), indicating a possible problem. The SAFELINE supply and discharge valve in the single version is a classified component in CATEORY according to ISO EN 89 and is appropriate for use in safety circuits until PL=C. The version with a double redundant channel is made using two single solenoid valves / NC provided with diagnostics, mounted in series so that the Port of the first solenoid valve is linked to the Port of the second solenoid valve. It is sufficient that only one of the EV is de-energised to guarantee the discharge of the air circuit. If one of the two EV must remain blocked due to a malfunction, the other one ensures the discharge function of the pneumatic installation. Even in this case, the diagnostic system of both solenoid valves constantly monitors the state of the single EV. The SAFELINE supply and discharge valve in the double version is a classified component in CATEORY according to ISO EN 89 and is appropriate for use in safety circuits until PL=E. Both single and double solenoid valves are provided with the following certifications released by BUREAU VERITAS: - TYPE APPROVAL certificate according to the EN ISO 89 regulations - certification of examination of compliance in accordance to the machinery directive 006//CE II Ex na IIC T6 c (X) The AIRPLUS SAFELINE are solenoid valves marked as ATEX II D Ex tc IIIC T= C Dc (X) IP65 Construction characteristics Body Solenoid Operator Rear end cap Spool Spool seals Piston Spring Electrical Interface Operational characteristics Fluid Working Temperature Working Pressure, MIN Working Pressure, MAX Assembly and Installation: Aluminium Technopolymer Aluminium Aluminium Polyurethane Aluminium EN 0- DH Steel Male M PIN TYPE A Connector filtered and lubricated or non-lubricated air; if lubricated it must be continuous -0 C +50 C,5 bar 0 bar Undertake the installation respecting the safety requirements with regards to the system and components for hydraulic and pneumatic transmissions. Install the device as close as possible to the point of use. Its assembly is possible in any position. Pay attention to the flow direction, indicated on the main body with the labels IN and OUT. During the components discharge, high levels of noise occur. The use of a silencer on the discharge port is recommended. Ensure there is sufficient space for assembly during the installation process. Please ensure that the discharge area is always clear, and in case a silencer is used, periodically verify that it is not obstructed. It is possible to integrate and install the device in an existing AIRPLUS group or in a new installation, or else to use the device individually attaching it by aligning the assembled unit with the relevant fastening flange for the supply and discharge valve, or to use the device individually attaching it by aligning the assembled unit with the type "Y" fastening flange for the double supply and discharge valve. WARNIN! Pay particular attention to external factors such as the nearness of live wires, magnetic fields, metallic objects providing magnetic conduction very close to the device, which may influence and disturb the diagnostic system. WARNIN! The electrical connection must be made exclusively by specialized personnel, using components that have no voltage present. Only use power supplies which can guarantee a safe electrical isolation of the working voltage in accordance to IEC/EN 600-. Additionally, observe the requirements anticipated by the PELV circuits in accordance to IEC/EN 600-. CARE AND MAINTENANCE: WARNIN! Do not connect or disconnect the device when energised! Do not open and/or disassemble the parts that are included in the energised valve. Once the power supply is disconnected, wait for a few minutes before opening or disassembling parts of the valve that result in its disassembly. Before carrying out any operation, it is essential to remove the pneumatic and power supply to the device and wait for the residual pressure to be completely discharged. Please ensure that the discharge is always clear, and in case a silencer is used, periodically verify that it is not obstructed. Periodically remove any dust deposits from the valve using a damp cloth. Use soapy water to clean the device. Do not use corrosive or alcohol-based products. For maintenance operations on internal components, please consult with PNEUMAX SPA.

Regulatory Framework The purpose of the EU s Machinery Directive is to define the health and safety requirements in the framework of designing and constructing machinery. Since 009, the new Machinery Directive has become effective in the European Union. Member countries of the EU are required to implement this standard. The manufacturers of machinery can comply with the Machinery Directive applying the harmonised standards listed in the Official Journal of the European Union. The design and manufacture of safety controls are developed in compliance with one of the two important harmonised standards: UNI EN ISO 89- Safety of machinery Safety-related parts of control systems Part : eneral design principles EN 606 Safety of machinery Functional safety of electrical, electronic and programmable control systems regarding safety The UNI EN ISO 89- standard is one of the most important harmonised standards, which has been widely used; it is intended to provide a guide to principles for design and integration of safety-related parts of the control system. Each safety-related control system must be designed and constructed in accordance with the principles of ISO 00 and ISO by which the possible risks are considered and assessed, in view of the intended uses and the reasonably anticipated incorrect uses. The parts of a machinery s control system are called Safety-related parts of control systems. Their capacity to perform a safety function under predictable conditions is assigned by means of five possible levels called "performance levels" (PL). These levels are defined in terms of probability of dangerous malfunction per hour. PL Performance Level a b c d e Average probability of dangerous malfunction per hour (/h) -5-0 to < 0-6 - x0 to < 0-6 -6 0 to < x0-7 -6 0 to < 0-8 -0 0 to < 0 The calculated PL must be greater or equal to the necessary value, which arises from the calculation of the risk correlated to one single function and to the need to reduce it to an acceptable level. S Slight danger S Serious danger F Occasional danger and brief exposure F Frequent danger and long exposure F Occasional danger and brief exposure F Frequent danger and long exposure P possibly avoidable danger P largely unavoidable danger P possibly avoidable danger P largely unavoidable danger P possibly avoidable danger P largely unavoidable danger P possibly avoidable danger P largely unavoidable danger PL = a PL = b PL = c PL = d PL = e www.pneumaxspa.com

Supply and Discharge Valve Single (VS) ATEX II Ex na IIC T6 c (X) II D Ex tc IIIC T= C Dc (X) IP65 7 6 65 M P TYPE A Pneumatic symbol 7 0 /" 7 65 6 M P TYPE A 0 /" 7 7.5 M P TYPE A 7 0 /" /" 0 7 0 /" /8" /" 0 Dimensions with fixing bracket mounted.5.5 Ø5.5 Ø5.5 8 6 6 Electrical Connection PIN DESCRIPTION + VDC (Sensor) + VDC (EV) ND (Sensor + EV) SENSOR OUTPUT Electrical Features Technical Features Electrical Connection Coil Features Suppressor diode for coil reverse voltage spike Supply Voltage Allowance Electrical features of sensor Sensor Features Operating Principle Contact Type Output Type Permanent Maximum Current Permanent Maximum Power Voltage Drop, MAX Safety features Regulatory Compliance Safety Function Fulfiled Performance Level (PL) UNI EN 89 Category Safety Integrity Level (SIL) PFH D Male M PIN TYPE A Connector VDC, Watt Present -5% +0% 0 0V DC Hall effect N.O. PNP 00 ma Watt V EN ISO 89- Interruption of supply and unloading of the downstream pneumatic circuit c -6,7*0 Connections Fluid Function Working Pressure, MIN Working Pressure, MAX Working Temperature Flow rate at 6bar p (from to ) Flow rate at 6bar p (from to ) Flow rate at 6bar (from to ) with free discharge Type of Installation Mounting Position Noise Level Response Time ON ISO 8 Response Time OFF ISO 8 Protection degree /" UNI-ISO 8/ filtered and lubricated or non-lubricated air; if lubricated it must be continuous / NC monostable,5 bar 0 bar -0 C +50 C 500 NL/min 000 NL/min 0 NL/min In line Indifferent 90 db 6 ms 76 ms Ip65 (with connector installed) V F Ordering code N7BVSVF VERSIONS = Standard*(without connections) M= Incorporated pressure gauge W= Incorporated pressure gauge (Right-Left) = /8" pressure gauge Connection FIXINS = Without fixing * 0= Fixing bracket mounted (Left-Right) 0= Fixing bracket mounted (Right-Left) * no additional letter required CE Marking In accordance with the EU Machinery Directive, annex V

Installation tip of a safety system by means of a Single Please note: the safety valve is not sufficient alone to guarantee the safety function. Its setup requires the use of a monitoring device. valve In this setup, the SIEMENS SK-BB0 monitoring device has been indicated, activated by an S start / reset pushbutton, blocked by an S emergency shutdown key. Said monitoring device, by means of the readings of the sensor placed inside the valve (reading made by means of the K relay), operates the activation of the valve itself. The monitoring device transmits the safety status as an output. The preliminary estimate and the final verification of the achieved PL are the responsibility of the designer of the part of the system dedicated to providing the safety function. Note: with a single valve, it is not possible to obtain a PL greater than "c". Setup suggestions The double stop pushbutton is connected to clamps T-IN and T-IN of SK-BB0. The start / reset pushbutton is connected between + V and the INS clamp of SK-BB0. The valve is supplied between 0 V (Pin of the supply connector) and the clamp of SK-BB0 (Pin of the supply connector). The HALL effect sensor is supplied between 0 V (Pin of the supply connector) and V (Pin of the supply connector). The HALL effect sensor drives (Pin of the supply connector) the K relay, whose N.A. contact will be connected between the monitoring device s clamp T and INF. The circuit diagram of the suggested configuration is provided, along with the configuration of SK-BB0. VDC 0 VDC S S K K A+ A- T IN T IN SK-BB0 INF INS SK-BB0 Configuration Autostart / Monitored Start Cross fault detection OFF / ON BLUE BROWN BLACK STATE single-ch. sensors / double-ch. sensor Startup test YES / NO EV Analysis of malfunctions The diagnostic system (monitoring device plus sensor) has the purpose of verifying the appearance of malfunctions within the valve that undermine the safety function. In particular, (with SK-BB0 configured as in the illustration), the K relay prevents resetting the system by means of S when the coil is deenergised, but the sensor remains in the OFF position (K remains de-energised).

Supply and Discharge Valve Double (VS) ATEX II Ex na IIC T6 c (X) II D Ex tc IIIC T= C Dc (X) IP65 6 7 7 M P TYPE A M P TYPE A.5 77 Pneumatic symbol Ø5. 7 Ø5. 0 0 /" 6 7 7 77 M P TYPE A M P TYPE A.5 Ø5. 7 Ø5. 0 0 0 /" /8" 6 7 7 8.5 M P TYPE A M P TYPE A.5 Ø5. 7 Ø5. 0 0 /" 0 0 Electrical Connection PIN DESCRIPTION + VDC (Sensor) + VDC (EV) ND (Sensor + EV) SENSOR OUTPUT Electrical Features Technical Features Electrical Connection Coil Features Suppressor diode for coil reverse voltage spike Supply Voltage Allowance Electrical features of sensor Sensor Features Operating Principle Contact Type Output Type Permanent Maximum Current Permanent Maximum Power Voltage Drop, MAX Safety features Regulatory Compliance Safety Function Fulfiled Performance Level (PL) UNI EN 89 Category Safety Integrity Level (SIL) PFH D Male M PIN TYPE A Connector VDC, Watt + Watt Present -5% +0% 0 0V DC Hall effect N.A. PNP 00 ma + 00 ma Watt + Watt V + V EN ISO 89- Interruption of supply and unloading of the downstream pneumatic circuit e -8,7*0 Connections Fluid Function Working Pressure, MIN Working Pressure, MAX Working Temperature Flow rate at 6bar p (from to ) Flow rate at 6bar p (from to ) Flow rate at 6bar (from to ) with free discharge Type of Installation Mounting Position Noise Level Response Time ON ISO 8 Response Time OFF ISO 8 Protection degree /" UNI-ISO 8/ filtered and lubricated or non-lubricated air; if lubricated it must be continuous / NC monostable,5 bar 0 bar -0 C +50 C 500 NL/min 000 NL/min 0 NL/min In line Indifferent 90 db 68 ms 79 ms Ip65 (with connector installed) V F D Ordering code N7BVSVFD VERSIONS = Standard*(without connections) M= Incorporated pressure gauge = /8" pressure gauge Connection FIXIN X= "X" Flange Y= "Y" Flange K= "Y" Aluminium flange FLOW RATE DIRECTION = Standard (Left-Right)* W= (Right-Left) * no additional letter required CE Marking In accordance with the EU Machinery Directive, annex V

Installation tip of a safety system by means of a Double Please note: the safety valve is not sufficient alone to guarantee the safety function. Its setup requires the use of a monitoring device. valve In this setup, the SIEMENS SK monitoring device has been indicated, activated by an S start / reset pushbutton, blocked by an S emergency shutdown key. Said monitoring device, by means of the readings of the sensors placed inside the double valve, operates the activation of the valve itself. The preliminary estimate and the final verification of the achieved PL are the responsibility of the designer of the part of the system dedicated to providin the safety function. Setup suggestions The double stop pushbutton is connected to clamps T-F-IN and T-F-IN of SK. The start /reset pushbutton is connected between + V and the F-IN0 clamp of SK. The double valve, for notation simplicity, is indicated as consisting of valves: EV and Ev Ev The valve is supplied between 0 V (Pin of the supply connector) and the F-Q clamp of SK (Pin of the supply connector). The HALL effect sensor is supplied between 0 V (Pin of the supply connector) and V (Pin of the supply connector). The HALL effect sensor is attached (Pin of the supply connector) to the monitoring device s F-IN clamp. Ev The valve is supplied between 0 V (Pin of the supply connector) and the F-Q clamp of SK (Pin of the supply connector). The HALL effect sensor is supplied between 0 V (Pin of the supply connector) and V (Pin of the supply connector). The HALL effect sensor is attached (Pin of the supply connector) to the monitoring device s F-IN clamp. The circuit diagram of the suggested configuration is provided. VDC 0 VDC S S BLUE BROWN BLACK EV BLUE BROWN A+ A- T F-IN F-Q F-IN F-IN5 F-IN7 F-IN9 T F-IN SK F-Q F-IN F-IN6 F-IN8 F-IN0 QM EV BLACK Analysis of malfunctions The diagnostic system (monitoring device plus sensors) has the purpose of verifying the appearance of malfunctions within the valves, which undermine the safety function. In particular, the monitoring device must be appropriately programmed to avoid the system s reset by means of S when both coils are deenergised and at least one sensor remains in an OFF position. Accessories Pressure gauge Ordering code V.S E D V s VERSION A = Dial Ø0 B = Dial Ø50 SCALE A = Scale 0- bar B = Scale 0-6 bar C = Scale 0- bar CODE A B A 5 B 0 0 B DIMENSIONS C 6 7 D 9 E C A /8" /8" Weight g. 60

S.p.A. 050 Lurano (B) Italy Via Cascina Barbellina, 0 Tel. +9.05.9777 Fax +9.05.97 info@pneumaxspa.com www.pneumaxspa.com D.DPL.-B 0/07 PRINTED IN ITALY 0/07 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice.