RTL. Floor Heating Controller Return temperature limiter with and without presetting

Similar documents
Mikrotherm F. Manual Radiator Valves With presetting

Regutec F. Return Lockshield Radiator lockshield

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

three-way mixing valve

Floor heating manifold with automatic flow control

Globo P. Ball valves Pump ball valve made of gunmetal

TA-6-way valve. Standard control valves 6-way valve for change-over systems

dynacon floor heating manifold with automatic flow control

DA 50. Differential pressure controllers Adjustable set-point

TA-PILOT-R. Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

Thermostatic radiator valves with presetting

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Pressure independent balancing and control valve For ON/OFF control

Pressure independent combined control and balancing valves with independent EQM characteristics

STAF-SG. ANSI flanges. Balancing valves DN

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

Pressure independent balancing and control valve

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

ACVATIX MiniCombiValves (MCV)

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

V2000Kx KV type TRV Body

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

HERZ-Motorised flow controler

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

Valve bodies type RA-N with integrated presetting

Fan-coil valves Series

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

RADIATOR VALVE ACCESSORIES

ACVATIX MiniCombiValves (MCV)

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

3-Port Seat Valves with Male Thread, PN 16

Valencia Radiator Valve Range

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

EMO TM. Actuators High performance proportional actuator For modulating control

3-Port Seat Valves with Male Thread, PN 16

3-port seat valves, external thread, PN16

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Self-operated Temperature Regulators Temperature Regulator Type 1u

Three-port slipper valves PN10, female-threaded

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

VPI45..Q with pressure test points. Combi valves, PN 25

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

High capacity valve body, type RA-G

2-Port and 3-Port Zone Valves PN 16

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

X-tra Collection for designer radiators and bathroom towel rails

Manual Presetting Valves LENO MSV-B

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

2-Port and 3-Port Zone Valves PN 16

Automatic balancing valves ASV-PV DN (3rd gen.)

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

k VS DN (mm) Connections ( C) (m 3 /h)

Connection. k VS -Value m 3 /h

System Components. Potable water Distributors, wall boxes and connections

Thermostatic valve Type AVTA

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

AV 23 Balancing valves SETTER Inline

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Cocon QTZ Pressure independent control valve

2-port and 3-port valves with T-bypass PN 16

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

4-way Distribution Valve

2-port and 3-port terminal unit valves PN16

Multiflex Fittings. Technical information

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

3-port seat valves PN16 with flanged connection

BUN: 3-way valve with male thread, PN 16

Connection. k VS -Value m 3 /h

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

2-port and 3-port ball valves PN 40

Flow controller (PN 25) AVQ - return and flow mounting

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

Technote. CirCon/TemCon - thermostatic valves for domestic hot water. Application. Advantages. Functions.

4017 M HERZ Dimensions in mm

MANIFOLDS AND DISTRIBUTION EQUIPMENT

Distributor for Floor Heating Systems

BUD: 3-way flanged valve, PN 6 (pn.)

Transcription:

RTL Floor Heating Controller Return temperature limiter with and without presetting

IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit the return temperatures of radiators or combined floor/radiator systems to equalize the temperature of smaller floor surfaces (up to ca. 1 m 2 ). Key features > > Models with presetting and automatic flow limitation (AFC) > > Body made of corrosion-resistant gunmetal > > Stainless spindle with double O-ring seal > > Outer O-ring can be replaced while under pressure > > Concealed limiting or blocking using stop clips Technical description Applications area: Heating systems Functions: Maximum limitation of the return temperature. Automatic flow limitation with Eclipse valves. Stepless precision presetting with V-exact II valves. Shut-off. Temperature range is limited on both ends and can be blocked using covered stop clips. Control behavior: Proportional controller without auxilliary energy. Dimensions: DN 1 Pressure class: PN Temperature: Max. working temperature: 1 C Min. working temperature: 2 C Maximum sensor temperature: 60 C Specific extension: 0. mm/k, Valve stroke limiter Flow range Eclipse: The flow can be stepless pre-set within the range: -10 l/h. Delivery setting 10 l/h. (Max. nominal flow qmn at kpa respecting EN 21: 11 l/h) Differential pressure (ΔpV) Eclipse: Max. differential pressure: 60 kpa (<30 db(a)) Min. differential pressure: 0 l/h = kpa 0 10 l/h = 1 kpa Marking: THE, flow direction arrow, DN -Designation. II+ -Designation. Material: RTL thermostatic head: ABS, PA6.6GF30, brass, steel, Thermostat filled with an expansible medium. Valve body: corrosion resistant Gunmetal O-rings: EPDM rubber Valve disc: EPDM rubber Return spring: Stainless steel Valve insert: Brass, PPS Spindle: Niro-steel spindle with double O-ring sealing. The outer O-ring can be replaced under pressure. Colour: White RAL 9016 Surface treatment: Valve body and fittings are nickel-plated. Pipe connection: The female-threaded version is designed for connection to threaded pipe, or in conjunction with compression fittings, to copper precision steel or multi-layer pipe (only DN 1). The male-threaded version, in conjunction with the appropriate compression fittings, permits connection to plastic pipe. 2

Construction RTL return temperature limiter without presetting 1. Valve body 2. Sensor 3. Overstroke safety Function The return temperature limiter RTL is an automatic thermostatic controller. The temperature of the flowing medium is transferred to the sensor via conductivity. This keeps the specified value constant within a proportional band necessary for control. The valve only opens when the set limiting value has not been reached. Application Among other things, the return temperature limiter RTL is used to limit the return temperatures of radiators or combined floor/ radiator systems to equalize the temperature of smaller floor surfaces (up to ca. 1 m 2 ). The return temperature is constantly controlled. With floor heating systems, it is important to note that the flow temperature controlled by the system is approp riate for the particular system installed. Please make sure the setting value is not below the ambient temperature of the return temperature limiter, as this would then no longer open (carefully choose location of installation). This may also be the case if the return temperature limiter is influenced by transferred heat, e.g. by mounting a floor heating circuit distributor directly on the return collector. Eclipse For RTL valves with automatic Eclipse flow limitation the required design flow for each radiator is set directly on the thermostatic valve. This automatic flow limitation is done with a twist and the adjusted flow will then not be exceeded. Even if there is an oversupply of pressure, due to load changes in the system, for example other valves closing or during morning start up, Eclipse will guarantee the requested flow. Noise behaviour To ensure low-noise performance, the following conditions must be met: On the basis of experience, the differential pressure over the thermostatic valves should not exceed about kpa = 0 mbar = 0.2 bar. If in designing the system, higher transient differentials might be experienced in the part-load flow range, differential pressure control equipment such as a STAP Differential Pressure Controller or Hydrolux bypass valves can be used (see diagram for noise characteristic curve). Mass-flow must be correctly adjusted. The system must be completely deaerated. Noise behaviour Eclipse To ensure low-noise performance, the following conditions must be met: The differential pressure above Eclipse should not exceed 60 kpa = 600 mbar = 0,6 bar (<30 db(a)). Flow must be correctly adjusted. The system must be completely deaerated. 3

IMI HEIMEIER / Floor Heating Control / RTL Sample application Return temperature limiting on radiators Floor heating RTL RTL RTL 1. Thermostatic valve 2. Regulux lockshield Note The composition of the heat transfer medium should be one which avoids damage or the accumulation of stones in hot water heating systems, in accordance with VDI guide line 3. For industrial and long-distance energy systems, see applicable codes VdTÜV and 1466/AGFW FW. Heat transfer media containing mineral oils or lubricants containing mineral oil can have seriously negative effects on the source apparatus and usually lead to the disintigration of EPDM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly details concerning concentration and specific additives. Functional heating Carry out functional heating of heating screed conforming to standards in keeping with EN 1264-4. Earliest start for functional heating: Cement screed: 21 days after laying Anhydrite screed 7 days after laying Do not exceed maximum floor temperature at the heating pipes: Cement and anhydrite screed: C Poured asphalt screed: 4 C according to screed manufacturer s technical advice! Begin C - 2 C flow temperature and maintain for 3 days. Then set maximum design temperature and maintain for 4 days. Flow temperature can be regulated by controlling the heat generator. Turn the protective cap anticlockwise to open valve or turn RTL head to Position. Refer to the screed manufacturer s information! Settings Number on dial 0 1 2 3 4 Return temperature t R [ C] 0 30 40 0 Return temperature t R [ F] 32 0 68 86 4 122 4

Technical data RTL Eclipse with automatic flow limitation l/h 160 2 db(a) 30 db(a) max. Lowest flow tolerances 140 1 0 80 60 40 min. 0 0 30 40 0 60 kpa 30 0 70 90 1 130 10 l/h - 0 l/h: kpa 0-10 l/h: 1 kpa *) P-band [xp] max. 2 K. Setting 1 l l l l l l l l l l l 1 l/h 30 40 0 60 70 80 90 0 1 1 130 140 10 P-band [xp] max. 2 K. P-band [xp] max. 1 K bis 90 l/h. Setting values with different radiator performances and system differential temperatures 0 300 400 00 600 700 800 900 00 10 1400 1600 1800 00 20 2400 2600 l/h 8 1 3 4 7 9 12 14 2 3 3 4 7 8 9 11 13 1 2 2 3 3 4 6 7 8 9 12 14 1 1 2 2 3 3 4 6 7 8 9 12 13 14 1 Q = Radiator performance Δt = System differential temperature Δp = Differential pressure Sample: Q = 00 W, Δt = 8 K Einstellwert: 11 (=1 l/h)

IMI HEIMEIER / Floor Heating Control / RTL Technical data RTL V-exact II with stepless precision presetting Diagram, valve body with thermostatic head P-band [xp] 2,0 K kv 0,02/ xp 1 K 0 00 30 300 0 1 2 3 4 6 7 8 0 0 3 30 2 1 0, 0,3 3 p [kpa] 0,2 0,1 1 2 ª [kg/h] 3 30 0 0 0 300 2 1 00 Δp [mbar] Thermostatic radiator valve (DN /1) with thermostatic head Presetting 1 2 3 4 6 7 8 Permitted differential pressure, during which the valve is kept closed Δp [bar] Kvs 0,049 0,2 0,18 0,313 0,4 0,6 0,740 0,860 Flow tolerance ± [%] 18 16 14 12 1 Kv/Kvs = m3/h at a pressure drop of 1 bar. Sample calculation Target: Setting range Given: Heat flow Q = 1308 W Temperature spread ΔT = 1 K (/40 C) Pressure loss, thermostatic valve ΔpV = 1 mbar Solution: Mass flow m = Q / (c ΔT) = 1308 / (1,163 1) = 7 kg/h Setting range from Diagram: 4 6

Technical data RTL without presetting 30 2 K 4 K 6 K 8 K K kvs 300 0 0 0 3 30 2 1 0, 0,3 3 0,2 2 Δp [kpa] 0,1 ª [kg/h] 30 0 0 1 0 300 00 00 Δp [mbar] Controller with valve body (angle, straight) DN 1 (1/2 ) Kv P-band xp [K] Kvs Permitted differential pressure at which the return temperature limiter still closes p [bar] 2 4 6 8 0,32 0,66 1,00 1,34 1,60 2,00 1 7

87, 87, IMI HEIMEIER / Floor Heating Control / RTL Articles RTL with Eclipse automatic flow limitation SW2 Angle 28 H1 D SW1 l3 l4 d2 DN D d2 l3 l4 H1 Flow range EAN Article No [l/h] 1 (1/2 ) Rp1/2 R1/2 29 8 21, -10 402402931712 9113-02.000 SW1 H2 D l1 l2 SW2 d2 Straight DN D d2 l1 l2 H2 Flow range EAN Article No [l/h] 1 (1/2 ) Rp1/2 R1/2 66 9 21, -10 4024029319 9114-02.000 ø3 RTL Thermostatic head for reverse-flow temperature white RAL 9016. With heat transfer piece expecially for thermostatic radiator valves. Setting range EAN Article No 0 C - 0 C 4024029112 6-00.00 Articles RTL with V-exact II stepless precision presetting SW2 Angle 28 H1 D SW1 l3 l4 d2 DN D d2 l3 l4 H1 Kv p-band max. 2 K 1 (1/2 ) Rp1/2 R1/2 29 8 21, 0,02 0,670 Kvs EAN Article No 0,86 402402899111 93-02.000 SW1 H2 D l1 l2 SW2 d2 Straight DN D d2 l1 l2 H2 Kv p-band max. 2 K 1 (1/2 ) Rp1/2 R1/2 66 9 21, 0,02 0,670 Kvs EAN Article No 0,86 402402899319 94-02.000 ø3 RTL Thermostatic head for reverse-flow temperature white RAL 9016. With heat transfer piece expecially for thermostatic radiator valves. Setting range EAN Article No 0 C - 0 C 4024029112 6-00.00 8

Articles - RTL without presetting incl. RTL Thermostatic head Ø 3 7 9 R1/2 SW2 SW1 Rp1/2 28 Angle Connection Kvs EAN Article No R1/2 2,00 40240228716 9173-02.800 7 29 Angle Ø 3 SW2 G3/4 8 Connection Kvs EAN Article No G3/4 2,00 40240228013 913-02.800 R1/2 R1/2 Straight Ø 3 SW2 9 Connection Kvs EAN Article No R1/2 2,00 40240228914 9174-02.800 SW1 7 Rp1/2 Ø 3 Straight Connection Kvs EAN Article No 7 SW2 G3/4 2,00 40240228112 914-02.800 R1/2 G3/4 91 *) SW1: 27 mm; SW2: 30 mm Values H1 and H2 are at the bearing surface thermostatic head or actuator. Kvs = m 3 /h at a pressure drop of 1 bar and fully open valve. Attention: The RTL return temperature limiter without presetting is constructed from a special valve body and sensor element. Thermostatic valve bodies cannot be used. 9

IMI HEIMEIER / Floor Heating Control / RTL Accessories Thermostatic insert Eclipse with automatic flow limitation for thermostatic valve bodies with II+ marking, from 1. Retrofitting/ EAN Article No Replacement inserts For DN valve, 1, 402402940912 3930-02.300 Thermostatic insert V-exact II with stepless precision presetting for thermostatic valve bodies with II marking, from 12 and II+ marking, from 1. Retrofitting/ EAN Article No Replacement inserts For DN valve, 1, 402402841417 3700-02.300 Thermostat-Oberteil V-exakt with precision presetting for thermostatic valve bodies with boss marking, from 1994 to end of 11. With yellow label. Also suitable for reversed flow direction. Retrofitting/ EAN Article No Replacement inserts For DN valve, 1 402402737611 302-24.300 (also for DN V-exakt valve bodies) Note: After retrofitting to thermostatic inserts with presetting the appropriate RTL thermostatic head Article No 6-00.00 has to be used. Replacement heat transfer piece for RTL thermostatic head 6-00.00. EAN Article No 40240292113 6-00.433 Compression fitting for copper or precision steel pipe according to DIN EN 7/30-1/2. Female thread connection Rp1/2. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 1 mm. Follow the specifications of the pipe manufacturer. Ø Pipe EAN Article No 1 40240217017 21-1.31 16 40240217116 21-16.31 Compression fitting for copper or precision steel pipe according to DIN EN 7/30-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8-1 mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Ø Pipe EAN Article No 12 402402214211 3831-12.31 1 402402214617 3831-1.31 16 402402214914 3831-16.31 18 40240221218 3831-18.31

Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Ø Pipe L EAN Article No 12 2,0 402402127016 1300-12.170 1 26,0 402402127917 1300-1.170 16 26,3 402402128419 1300-16.170 18 26,8 40240212881 1300-18.170 Compression fitting for copper or precision steel pipe according to DIN EN 7/30-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Soft sealed, max. 9 C. Nickel-plated brass. Ø Pipe EAN Article No 1 402402181 1313-1.31 18 4024021606 1313-18.31 Compression fitting for plastic pipe according to DIN 4726, ISO 08. PE-X: DIN 16892/16893, EN ISO 187; PB: DIN 16968/16969. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel plated brass. Ø Pipe EAN Article No 14x2 402402134618 1311-14.31 16x2 402402134816 1311-16.31 17x2 40240213491 1311-17.31 18x2 402402131 1311-18.31 x2 40240213318 1311-.31 Compression fitting for Alu/PEX multi-layer pipe according to DIN 16836. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel-plated brass. Ø Pipe EAN Article No 16x2 402402137312 1331-16.31 Compression fitting for Alu/PEX multi-layer pipe according to DIN 16836. Female thread connection Rp 1/2. Nickel-plated brass. Ø Pipe EAN Article No 16x2 402402138616 133-16.31 RTL thermostatic head As spare part for return temperature limiter RTL without presetting. Colour EAN Article No white RAL 9016 40240227311 600-00.00 Spindle extension for RTL Brass, nickel-plated. L EAN Article No 40240021 913-.700 Insert for RTL Since 12 (II marking on the valve body). With 2 mm brass sleeve. EAN Article No 402402909711 130-02.300 11

IMI HEIMEIER / Floor Heating Control / RTL The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 3400-18.483 EN RTL 11.17