Enclosed. High-Performance Resistors. Designs and solutions

Similar documents
Braking Resistors. customized solutions consistent casing design wire-wound the complete product range steel grid < cast iron

High power resistors for transportation systems

EX-D ENCLOSURES AND DISTRIBUTIONS

Unused flameproof threads for cable glands have to be closed with certified plugs.

DBR3, 4500W, 9R, TS - BRAKING RESISTOR

10 Load and Motor Switchgear

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

A good connection. International approvals.

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

10 Pressure/temperature measurement SCPT analogue

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

AC..CS SAFETY WIREWOUND RESISTOR

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Am Rotböll Weiterstadt fax +49 / /

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

SG-B1 SERIES / SG-A1 SERIES

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Pneumatically operated zero dead volume T-Valve CLASSIC

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Junction box for EKL light

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

20 HUBER+SUHNER RADOX SOLAR

GTK 80. Technical data

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Power Factor Correction

KATKO Safety Switches:

Product features & Overview. KA Linear actuators

LV Capacitor CLMD Reliability for Power Factor Correction

DC Cabling Ready for 1,500 V DC

Power Factor Correction Capacitors Type LKT

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Low and Medium Voltage Motors. 21-FII Series. New High Efficiency Design 37 kw 1,400 kw (50 HP 1,850 HP)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

CrossBoard. The new basic system

Pressure switch, high adjustability of switch differential

Am Rotböll Weiterstadt Telefax /

SPECIFICATION FOR APPROVAL

Cable resistance thermometer Model TR40

switchcontrol The robust opto-electric position indicator

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

SKINTOP ST-M, increased oil-resistant plastic cable gland with variable clamping ranges, permanent vibration protection, for offshore platforms

Cable resistance thermometer Model TR40

International approvals.

Rotary Disconnect Switches, Bulletin 194R

Electronic Braking Systems

Pressure/temperature/RPM measurement

Cabinet-built single drives, ACS880-07

Size and Configurations

supplied in Form (B) configuration. Airflow over Impeller- Motor.

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

CAST RESIN TRANSFORMERS

High Performance Thermal-Magnetic Circuit Breakers 410/520/

Installation Accessories

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

dp pumps dpv vertical pumps The dynamics of water made in holland

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Order No. of the options EMC filter Class A

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

PORTS, MARINAS, SHIPYARDS & VESSELS

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

OLIVER ONLINE VOLTAGE REGULATION

COMPRESSOR SYSTEMS MADE IN GERMANY OIL-FREE SCREW COMPRESSOR LENTO

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Junction boxes. X series

varistor plus catalog

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Limit Switches and Safety

Industrial Electric Convectors

Armoured / Un-armoured Cable Gland

SKINTOP ST-M, increased oil-resistant plastic cable gland with variable clamping ranges, permanent vibration protection, for offshore platforms

Product information. ECOSS Electronic compact starter for wound rotor drives

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Standard Interlock Safety Switches

Motors Automation Energy Transmission & Distribution Coatings. Flat-frame Motors K1F / K2F

Technical Data Sheet Sigma Series DG Meter

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

SLH-SERIES. Automatic Sliding Doors

Electric operated valves Type CCM for R744 / CO2

setting the standard Electromagnetic braking systems for wind turbines

Demag KB conical-rotor brake motors. Drives with unique principle

MOBILE PURE AIR DUST EXTRACTORS AL-KO POWER UNIT

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

High Reliable Components for Power Factor Correction and Power Quality

Transcription:

Enclosed High-Performance Resistors Designs and solutions >> Fully enclosed design Type of enclosure IP54/IP65 Pulse-proof, high overload capacity Low inductivity Robust, durable and vibration-proof With or without protection against accidental contact Combinations and special solutions

Enclosed high-performance resistor profiles System VPR VPR resistors are enclosed in an aluminium profile with PTFE insulated connecting wires of pure nickel. The designs S = vertical and L = horizontal are available. The resistors can be mounted as standalone units or on a mounting base. The mounting area must be resistant to the intended operating temperature, and flame-retardant. Any installation location is possible, optimum cooling conditions are achieved in vertical position with the connecting wires at the lower end. Type of enclosure IP65 Permanent performance from 60 W to 500 W and 800 W to 1500 W Operating voltage: 800 V up to 200 W, 1000 V > 200 W, in special design also 1500 V Test voltages up to 2.5 kv or 4 kv, in special designs also up to 6 kv Vibration-proof up to 4 g Tensile strength of wires 100 N Resistant to climatic conditions and rupture-proof Dimensions from 102x40x21 mm to 337x60x31 mm or from 340x50x100 mm to 700x50x100 mm

VPR profiles in various housings System DEG The enclosed resistors can be combined in various housings. Due to their design, the DEG types are also suitable for operation in high humidi condition. In the standard design, the resistors are mounted on a terminal block so that the resulting type of enclosure is IP20 or, with connection box or connection line, IP54. Cable entry is ensured through cable glands. Resulting type of enclosure IP00 to IP54 Permanent performance from 100 W to 4000 W High overload capacity in short-term operation Operating voltage: 800 V up to 200 W, 1000 V > 200 W, higher voltages available in special designs Test voltages up to 2.5 kv or 4 kv, higher test voltages available in special designs Resistor profiles can be combined Vibration-proof and impact-proof Resistant to climatic conditions and rupture-proof Optional temperature monitoring

Special designs Systems VPR and DEG Different requirements are to be met by special, customer-specific solutions. Enclosed resistor profiles are also available in three-phase design and integrated star-type jumper or equipped with a shielded connecting line. The flexible application range is rounded off by projectspecific assemblies and housings for direct installation underneeth the frequency converter. Applications: Precharging and discharging resistors, e.g. for capacities Voltage-limiting resistors and series resistors Three-phase load resistors Assemblies for the traffic sector Automotive applications Housings for substructures Braking resistors Other technical data as for VPR resistors or DEG housings.

Water-cooled resistor solutions System VPR-W By using water-cooled resistors, the heat development that usually occurs at the location of use is prevented. During braking processes, the electrical drive energy is converted to heat energy. This heat energy is absorbed by the water and can be re-used. Whereas in smaller resistor systems the cooling water is routed directly through the resistor profile, heat exchangers are used in resistors with a power > 50 kw. Converter with Choppermodule Inlet Cascadable installation possible Cooling circuit / heat exchange Performance range from 4 kw to approx. 500 kw Great application variety, including mining technology M Motor Braking resistor with water-cooling Outlet Clearly improved energy efficiency Various designs and systems No heat dissipation to the environment Application also in explosion-hazardous areas

<< Information about optional UL mark Our enclosed VPR resistor profiles are already UL-certified up to the size of VPR500 so that marking with the cur mark according to our UL File E221095 is permitted. A number of housing combinations DEG and special designs are likewise covered with the cur certificate according to the UL File. R C US << Surface temperature on housing of VPR resistors T C 400 350 Ambient temperature 300 40 C 20 C 250 200 150 100 50 0 0 10 20 30 40 50 60 70 80 90 100 Duty factor % Ihr Weg zu uns Friedrich-Wöhler-Str. 65, 53117 Bonn, Tel. 02 28 / 9 89 86-0 Rh e l Kö ns tra A555 de r J he Lie ve g lin sweg Doro thee n weg A565 Vorg ebir gss traß e Bo rn h eim er Certified acc. to ISO 9001: 2015, IRIS Siegburg stra Stra B56 ing l-r ar -K DW_e_07/2009 Ak Bonn-Nord A555 info@gino.de www.gino.de/en hö in A565 Opp elne r Stra Lievelin gs fs st ra Ka i se r Telefon: +49 228 98 98 6-0 Fax: +49 228 98 98 6-34 An e os er ra St B9 Köln Rö m St ra ler rse He Gino AG Elektrotechnische Fabrik Friedrich-Wöhler-Str. 65 53117 Bonn Germany Par ise r << Your contact: GINO GmbH Elektrotechnische Fabrik, Zentrale Bonn