AccuPower AQU126B Installation Instructions

Similar documents
AccuPower AQU128B Installation Instructions

Installation Instructions

Installation Instructions

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

SMP3CTX Series Power Supply/Charger

AL600ULX Series. Power Supply/Charger Installation Guide

Package Contents. Mounting Hardware

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

M670/M680BD MAGNALOCK SERIES Installation Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

2904 Power Supply Installation Instructions I-EA00041

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SmartLock Accessories

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

PSU EN54-4 Power Supplies

Industrial Power Supplies

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Specification of Soneil Battery Charger

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

Product Installation Document

MODEL NUMBER: APS2448UL

SECURITY DOOR CONTROLS

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Accessories 286 SDC SECURITY DOOR CONTROLS

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Excel Series Value Engineered Access Hardware

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

Specification of Soneil Battery Charger

Power Supplies DORMA PS

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

SECURITRON POWER SUPPLIES MODELS: BPS-12-3, , 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS

TRAC-Station BT Installation Instructions

Model LA 4100 Time Delay OFF Controller

Non-Spring Return EconoDrive Floating Actuator

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Powerware Vdc Extended Battery Cabinet User s Guide.

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

ID ID. Series 19. Mechanical Products Company

Installation Instructions & Users Manual

User Manual. Solar Charge Controller 3KW

Emotron DCM Control Unit

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS3636VR

MODEL NUMBER: APS2012

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Uninterruptible Power Supplies

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Innovative Circuit Technology Ltd.

Operating and Installation Instruction Manual

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

Solar Hybrid Inverter SP Brilliant Series

Illuminator System Series CM

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Uninterruptible Power Systems

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

630 Series Power Supplies

MODEL NUMBER: APS2424

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Electric Actuator Instructions

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

CONTROL MICROSYSTEMS Power Supply. Hardware Manual

IMPORTANT SAFEGUARDS

Installation Instructions Central Battery Units

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

User Manual Solar Charge Controller 3KW

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Model LA 4400 Time Delay OFF Controller

User Manual 1KVA-5KVA INVERTER / CHARGER

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Transcription:

Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead Acid or Gel Cell Batteries* 1/16 Flat head Screw Driver 6-32x1/4 Mounting Screws *See Battery sizing guide on page 6. Physical Size: AccuPower AQU126B Specifications Mechanical Electrical Environmental Regulatory Board: 3 15/16 x 6 3/8 x 2 3/8 Mounting: : 3 9/16 x 5 3/8 Weight* AQU126B 1.5 lbs Input Voltage Operating Range 110-240VAC 47-63Hz Maximum Output Voltage 72 VA 6 Amps @ 12VDC (±10%) Continuous Output Voltage: 60VA 5 Amps @ 12VDC ((±10%) Voltage Range: 9.8-13.7 VDC/ 13.65V typical Frequency 27KHz Operating Temperature 0ºF to 130ºF [-17 to 54ºC] Humidity 10% to 95% RH For Indoor use Recognized Component: UL294 UL603 UL1481 cul RoHS Compliant Copyright, 2013, all rights reserved Page 1 P/N 500-30035

Overview of AQU126B Series Power Module The Securitron AccuPower AQU126B offers clean, steady and accurate power output for peak performance of access control equipment plus flexibility unmatched by any power supply/battery charger on the market today. Universal AC input with brownout tolerance to 60VAC Tolerates and protects against input voltage fluctuations. External LED AC power indicator Form C contact for AC power fail notification Dedicated voltage for battery charging even under full load Low battery disconnect prevents deep discharge of batteries PTC protection for Thermal Runaway and Current Overload Short Circuit and Reverse Battery protection - will auto restart without removing load. AQU126B and AQU126 provide a single output. The output can be divided into additional channels using any of the optional power distribution boards: PDB4, PDB8, PDB-8F8R, PDB-8C8R, PDB-8C1R or PDB-1R. Applications The AQU126 Series can be used with electrified access control equipment in conjunction with access control systems and fire/burglary systems including most electrified locking hardware and latches, card readers, keypads, electric strikes, REX and motion detectors and more. Pre-Installation Survey Before installing the AQU126 Series, the mounting location should be determined and assessed for the following: Availability of AC power service Protection from vandalism and tampering Sufficient clearance for air circulation and heat dispersal CAUTION: Check with your local code inspectors to ensure your compliance with the National Electrical Code (ANSI/NFPA 70), (Canadian Electrical Code for Canada) or equivalent and any additional licensing and wiring requirements for your jurisdiction. Page 2 P/N 500-30035

A. Installing the Power Module 1. Select mounting location so that AC input conduit can be aligned to maintain separation with DC power outputs. Ensure unit is mounted with sufficient airflow to prevent heat buildup. IMPORTANT: AC Power input is not power limited. AC lines must be enclosed in approved conduit. AC Input lines must be separated by at least ¼ from Class 2 power limited output wires. Mark board mounting hole locations and drill. Install mounting screws appropriate for the mounting location, leaving enough hardware exposed to install standoffs. Install standoffs. Place starwheel on any one of the three standoff locations corresponding to a mounting location on the board that has a metal ring. Affix board to standoffs with provided metal screws. IMPORTANT: User is responsible for observing all electrical and code requirement when installing in self-provided enclosure or mounting location. B. Make Electrical Connections 1. Component Locations Page 3 P/N 500-30035

2. Understanding the Power Module Component Label AC L N AC FAIL -DC+ -BAT+ DC LED LOW BAT Component Name AC LED Connector AC In Terminal Block AC Status Relay DC-Out Terminal Block Battery Backup Plug DC Output Power Indicator Low Battery Warning Relay 3. Make AC Power Input Connections IMPORTANT: VERIFY AC POWER IS OFF BEFORE MAKING CONNECTIONS The AQU126 has a universal transformer that accommodates 90-240 VAC input. Connect AC power wires as follows: Black/Positive = L White/Negative = N Green/Ground= G Function 2-pin connector for plug-in onboard LED or remote LED harness (included) A 3-wire terminal block for AC power input. Handles 110-240 VAC. Accepts wire gauge 12AWG to 18AWG. L = Line (+) N = Neutral = Ground A 3-wire terminal block providing a SPDT-Form C contact that changes state when the AC power is interrupted. Provides 2amp@120VAC output for triggering alert notification NO = Normally Open C = Common NC = Normally Close The switch is NO/C open when energized, C/NC closed when energized. During power loss, the switch changes state with NO/C closed and C/NC open. A 2-wire terminal block for DC output voltage to devices, power distribution or accessory board. Accepts 10 AWG to 24AWG wire. NOTE: DC output is not power limited. A 2-pin plug for connecting battery cables for uninterruptable battery backup. Red LED indicator is lit when DC power is ON. Three position terminal block providing a SPDT Form C contact that changes state when battery output drops to 11V. Default position is Normally Open when energized. Terminal accepts 22-30AWG wire. 4. Make DC Power Output Connections to Distribution or Accessory Boards Using 18 to 24 AWG wire, connect the DC OUT Positive (+) terminal to the positive (+) IN terminal on the distribution board. Connect the DC OUT Negative (-) terminal to the Negative/Common/C (-) IN terminal on the distribution board. It is recommended to pass the wires under the power module board before connecting to the accessory board in order to maintain separation from battery cables. Page 4 P/N 500-30035

5. Make DC Power Output Connections to Devices Using 10AWG to 24AWG wire, connect the device wire run to the DC outputs. Maintain separation from battery cable placement by passing wires under power module before connecting to terminal screws. Connect the Positive wire to DC OUT Positive (+) terminal Connect the Negative wire to DC OUT Negative (-) terminal -/Negative +/Positive Note: Use appropriate wire gauge for the Amperage and distance of the run. For more info, see Wire Loss Calculator at http://www.securitypower.com/an2wire.html 6. Wiring for Status Monitoring Options AC Fail NO C NC Access Control System Panel The diagram shows basic wiring to provide output to a control panel or local alarm for notification of AC power loss. AC-ON state energized the NO/C switch. The Switch changes state when power is lost. 7. Wiring for Limited Time Warning/Low Battery Low Bat NO C NC Access Control System Panel The diagram shows wiring to an access system controller to provide low battery warning. The switch changes state from NO/C to C/NC when battery voltage drops to 11VDC 8. Turn on AC Power After making electric connections, turn on AC power before installing batteries. The AC LED power indicator should be lit. Page 5 P/N 500-30035

C. Install Batteries 1. Understanding Battery Charging and Backup Power The AQU126B is a backup battery charger with automatic fail over to battery power in case of primary AC power failure when batteries are installed and connected to the power module. The use of battery backup is optional - the unit will function without batteries installed, but no internal backup power will be available in case of AC power failure. Note: The battery circuit features automatic disconnect when the battery output falls to 9.8VDC to prevent deep discharge and also protects the power module in case the battery is connection is reversed. For battery backup in 12VDC operation, a single 12V battery may be used, or two (2) 12V batteries may be used wired in parallel for longer run time. Backup power run time depends on the continuous output needed to support the load and the ambient temperature at the enclosure. Estimates are provided in the Estimated Time table: Estimated Time (3 amp/5 minute reserve for alarm) Amps 4Ah Battery 7Ah Battery 12Ah Battery 24Ah Battery 40Ah Battery 3A.6 Hrs 1.1 Hrs 2.4 Hrs 5.7 Hrs 9.5 Hrs 4A.4 Hrs.79 Hrs 1.5 Hrs 3.6 Hrs 7.4 Hrs 5A.32 Hrs.63 Hrs 1.2 Hrs 2.9 Hrs 5.9 Hrs 6A.27 Hrs.49 Hrs.96 Hrs 2.4 Hrs 4.75 Hrs Larger batteries may be used external to the enclosure by running the battery cable through a dedicated knockout separate from the AC input and DC output. Charge current is not less than 500mA @12VDC at peak load. 2. Connecting the Battery Plug battery cable assembly into battery backup plug -BAT+. Install batteries. Mark batteries with Installed date and Replace By date according to manufacturer s battery life recommendations. Connect leads to batteries. For 12VDC operation: Connect red battery lead to the Positive (+) battery terminal. Connect black battery lead to the Negative (-) battery terminal. D. Testing 1. Test Input and Outputs AC Input: Enable AC power to input line. Confirm LED on front of enclosure is lit. DC output: If connected to load or distribution board, DC output indicator on power module will be lit. If not connected to load or distribution board, test output with Amp Meter to verify current. AC Fail Notification: Disable AC power to input line. If AC fail notification is configured, the switch will change state, triggering the notification output. Low Battery Notification: Disable AC power to input and allow batteries to run down to Low Battery Warning Page 6 P/N 500-30035

Recommended Annual Maintenance Turn off AC power Battery Test AC Fail Test Check DC output voltage under battery operation. For fully charged batteries, voltage should be above 11.5V. If voltage is below this range, test batteries per battery manufacturer instructions and replace if needed. Turn off AC power. AC Fail switch should trigger an alert upon disconnect or upon fail over to battery power. Problems with installation? Call Securitron: 1-800-MAG-LOCK For warranty information visit: www.securitron.com/en/site/securitron/about/magnacare-warrantyxsd Page 7 P/N 500-30035