INSTALLATION MANUAL IMMOBILIZER: IM125R-24A

Similar documents
Transponder Immobilizer Genius GT-550

TRAILER LIGHTS CONTROL UNIT MP4S INSTALLATION MANUAL

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

1. Ignition Key IGNITION KEY A: GENERAL SL-2

Ignition Key, Remote Control Key

MiX 2310i with IP Housing. P r o d u c t I n f o r m a t i o n G u i d e

CATALOG. Vehicle GPS Tracking. Mini GPS Tracker. Contact: Allan Feature. Accessories

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Keys and doors. Keys Models without keyless access with push-button start system Models with keyless access with push-button

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

Technical Bulletin AA 304. Central Locking System. m.y. 97

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

CA-210 Installation Instructions

2-2. Keys. start system (if equipped)

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

User Guide TWO-WAY LED AUTOMATIC/MANUAL TRANSMISSION REMOTE STARTER WITH FULL ALARM SYSTEM

EQUIPMENT - MAIN BODY 7-1 SECTION 7 EQUIPMENT CONTENTS

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

INTELLECTUAL PRIZRAK TECHNICAL SPECIFICATION

TWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

Model PRO 9246CH Installation Manual

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

User Guide WARNING TWO-WAY 6-BUTTON LCD AUTOMATIC/MANUAL TRANSMISSION REMOTE STARTER SYSTEM WITH FULL ALARM SYSTEM

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

Moonroof (if equipped) Moonroof switches Sun shade

CA-110 Installation Instructions

Vehicle Security System

ZN-502 A/S/AS USER MANUAL

ELECTROMAGNETIC LOCKS

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

Vehicle Security System

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Model APS-101N Installation Manual

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

CS-2900DP-FM Infinity DP SERIES II (DATA PORT) 2-Way FM Paging Alarm & Remote Engine Starting System OPERATION INSTRUCTIONS

Model APS-25N Installation Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

RF-30-EDP Deluxe OEM Upgrade & Range Extender October 25, 2012 Operation Guide

DYNATECH D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM DYNAMICS AND TECHNOLOGY, S.L.

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

INSTALLATION GUIDE Table of Contents

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

DLKEK3HN INSTALLATION INSTRUCTIONS

Moonroof (if equipped) Moonroof switches Sun shade

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

QUICK INSTALLATION GUIDE

Pandora would like to thank you for choosing our LIGHT+ service and security system

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

GCU-10. Automatic Engine Control Unit Operators Manual

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

2001 Dodge Durango ACCESSORIES & EQUIPMENT' 'Anti-Theft Systems - Dakota & Durango 2001 ACCESSORIES & EQUIPMENT

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

Model APS-25CH Installation Manual

Owner's Manual. Remote Security and Convenience System INS0866 8/98

TRAILER LIGHTS CONTROL UNIT MP4-D2 INSTALLATION MANUAL

SHERIFF ZX Importance

UltiMate Vehicle Systems ultimate-10-edp

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT

CS-2001 REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

e-ask electronic Access Security Keyless-entry

Pandora would like to thank you for choosing our DXL-0090L service and security system

AK-105B. ADVANCED KEYS Smart Keyless Entry + Push Start Ignition System USER MANUAL. Product Features:

AS-1774 / 1774U. User Guide 5-BUTTON AUTOMATIC / MANUAL TRANSMISSION REMOTE STARTER

AWZ 110. AWZ 13,8V/1A/7Ah/LM

VEHICLE THEFT/SECURITY SYSTEMS

COPYRIGHT 2011 LAND ROVER UNLOCKING TECHNOLOGY

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

User Guide 1 WAY FM MANUAL TRANSMISSION REMOTE STARTER. Table of Contents. Introduction

SISTEMA DE CONTROL DEL MOVIMIENTO INCONTROLADO DE LA CABINA UNINTENDED CAR MOVEMENT CONTROL SYSTEM

FM SECURITY AND REMOTE START SYSTEM

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

INSTALLATION MANUAL. Model: PLUS Vehicle Security

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

OPERATING INSTRUCTIONS

AS-1585 SH Installation Guide

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

DEEP SEA ELECTRONICS PLC

2012 > F 1.0 DOHC > Language

User Manual Solar Charge Controller 3KW

12V PROGRAMMABLE POWER OUT

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

SECURITY CONTROL SYSTEM

Onboard. Onboard RTU270 Installation Manual

RA2 Installation Manual Rev. B

2002 Dodge Intrepid ES ACCESSORIES & EQUIPMENT Anti-Theft Systems - Concorde, Intrepid & 300M

CM4200 and CM1000S Starter Control Module Installation Manual

U S A INSTALLATION GUIDE EP400 / E8-B

INSTALLATION GUIDE. FCC ID NOTICE

World-Class AutoSecurity TM

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

INSTALLATION MANUAL 601-S INFORMATION.) 8. REMOVE DOME LIGHT FUSE TO PRE- VENT BATTERY DRAIN.

24562/28562 Loader Radio Remote System

CS-2011RS Series III

AS-1535 SH. Installation Guide

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

AS-1414/ AS User Guide

Transcription:

INSTALLATION MANUAL IMMOBILIZER: IM125R-24A QUASAR ELECTRONICS ul. Cieślewskich 25K 03-017 Warszawa tel.(022) 678-68-96, 678-64-50 http://www.quasarelectronics.pl e-mail: biuro@quasarelectronics.pl Revision: 2009.04.08 090408_CK

IMMOBILIZER SPECIFICATIONS IM125R-24A is a transponder immobilizer (wireless authorization) powered by 12V to 24V, that operates on the frequency of 125kHz and offers basic anti-theft functionality. Despite its simple design the IM125R-24A immobilizer features all logical operations and self-check functions. The IM125R-24A features 2 internal electrical cut-off relays, operating on normally closed (NC) contacts. The immobilizer is operated by pendant shaped transponders (2 transponders are included). The immobilizer installation kit includes: a central unit, a 16-connector bundle of wires with a buzzer, LED, authorization switch and antenna. IMMOBILIZER FUNCTIONS The ability to assign up to 30 transponders; Possibility of non-transponder disarming using PIN CODE; 2 x electrical cut-off circuits in the NC configuration (normally closed, 2 x 30A relays); AS Authorization Switch used for entering PIN CODE; IGNITION ON input line (bringing the immobilizer off the power saving mode); STATUS output line (active low state); HORN output line (active low state); Auto-arming; "Service" mode; 4 programmable functions. PACKAGE CONTENTS: Main control unit of the IM125R-24A immobilizer - 16-pin bundle of wires IM125R-24A-W16 LED holder Transponders 1 pc. 1 pc. 1 pc. 2 pcs. Picture of all system components. LOGICAL FUNCTIONS DDI IISS AARRMMI IINNGG TTHHEE IIMMMMOOBBI I IILLI IIZZEERR In order to disarm the immobilizer, place the transponder close to the receiving antenna. Disarming the immobilizer is signalled in the following way: Buzzer - 2 short signals LED - goes OFF (stops flashing) STATUS - high impedance state. (each transponder read-out while the immobilizer is disarmed is signalled by 2 buzzer sounds). NOTICE: Armed immobilizer is in power saving mode. The antenna circuit is powered in 1 sec. on 2 sec. off cycle. Turning the ignition on causes the antenna circuit is powered constantly.turning the ignition on while in the armed state causes disconnection of circuits of the electric lock (switching the relays).

NON-TRANSPONDER DISARMING THE IMMOBILIZER In case of loosing or damaging the transponder there is possibility of immobilizer disarming using the 4-digits PIN CODE entered with the Authorization Switch (AS). Example of entering the PIN CODE 1 2 3 4: Turn ignition off (if it is turned on) FIRST DIGIT 1: Press AS 1 time (The LED starts light constantly), after 2 seconds the single buzzer signal confirms the digit was entered; SECOND DIGIT 2: Press AS 2 times, after 2 seconds the single buzzer signal confirms the digit was entered; THIRD DIGIT 3: Press AS 3 times, after 2 seconds the single buzzer signal confirms the digit was entered; FOURTH DIGIT 4: Press AS 4 times, after 2 seconds the single buzzer signal confirms the digit was entered; The LED goes off. Entering correct PIN CODE will be confirmed with 2 buzzer short signals, the immobilizer will be disarmed. In case the entered PIN CODE is incorrect there will be heard single, long for 3 sec. buzzer signal. Entering the incorrect PIN CODE for the fourth time causes that further entering PIN CODE is impossible for 60 sec. Every pressing the Authorization Switch in this case causes the long for 3 sec. buzzer signal. NOTE: THE FACTORY SETTING OF PIN CODE IS 2 2 2 2. AUTO-ARMING OF THE IMMOBILIZER. The immobilizer is automatically armed after a defined period of time (30 seconds or 3 minutes, depending on the "auto-arming time" function setting - see the chapter "Programmable functions" of the manual) from the moment of turning the ignition off. Going into the armed state is signalled in the following way: Buzzer - a single signal lasting for 5 seconds LED - flashes once per 1 second (50 ms ON - 1 second OFF) STATUS active state (ground level). NOTICE: Each read-out of the transponder resets the auto-arming countdown time again. SSI IIGGNNAALLLLI IINNGG TTHHEE IIMMMMOOBBI I IILLI IIZZEERR SSTTAATTUUSS WWI IITTHH TTHHEE LLEEDD OFF - the immobilizer is disarmed, flashes - the immobilizer is armed, ON indication that the armed immobilizer enters the alarming state with HORN output active or state of entering the PIN CODE (after pressing AS). STATUS OUTPUT The STATUS output indicates the immobilizer status: ground level (Imax=50mA) - the immobilizer is armed. high impedance state - the immobilizer is disarmed. HORN OUTPUT The HORN output is the alarm output: HORN - the intermittent signal (0,5 sec. ON - 1 sec. OFF) for 30 seconds. Turning the ignition on for the time longer than 10 seconds when the immobilizer is armed causes the LED begins to light constantly and triggers the intermittent operation of the HORN. The alarm can be interrupted by disarming the immobilizer (placing the transponder close to the antenna). The output active state: ground level (Imax=50mA). IMMOBILIZER "SERVICE" MODE The "service" mode is used, when it is necessary to leave the car for servicing, to enable the service teams to access and operate the vehicle. In this mode the immobilizer is disarmed (no auto-arming) while the power saving mode for antenna circuit is active. To activate the "service" mode you should: Disarm the immobilizer. Turn the ignition ON. Place the transponder close to the antenna for 10 seconds, until you hear a single, 2-second buzzer sound and then move the transponder away from the antenna vicinity and turn the ignition OFF within the 5 seconds time. The immobilizer is now in the "service" mode. The "service" mode of the immobilizer is signalled in the following way: Each turning the ignition ON or OFF is signalled by a 2-second buzzer sound. To deactivate the "service" mode you should proceed in the same way as when activating the "service" mode. PROGRAMMABLE FUNCTIONS

ENTERING THE PROGRAMMING MODE OF THE IMMOBILIZER FUNCTIONS: To enter the programming mode of the immobilizer functions you should: Activate the immobilizer "service" mode. Turn the ignition OFF (if it is turned on). Place the transponder close to the antenna for 10 seconds, until you hear a 5-second buzzer sound and then move the transponder away from the antenna vicinity. The buzzer will start beeping to indicate the number of the current programmable function and its current setting by emitting short signals with 3 second intervals (see the table below). The selection of the function setting is confirmed by placing the transponder close to the antenna after a particular number is signalled in accordance with the table below (the number of the buzzer signals) for approx. 2 seconds. Setting of function is confirmed by a 5-second buzzer sound. When a function has been set up, the process of signalling a function number restarts from 1. If within 5 seconds from signalling the last function number the transponder is not placed close to the antenna, the programming mode is deactivated. Deactivation of the programmable functions mode is signalled by a 5 second buzzer sound. Deactivate the immobilizer "service" mode. DESCRIPTION OF THE PROGRAMMABLE FUNCTIONS: FUNCTION No.: FUNCTION NAME FUNCTION SETTING 1 Auto-arming time 3 min (standard) 2 30 sec 3 Delay of activation cut-off relays 0 sec. - immediate (standard) 4 10 sec. 5 Assigning of transponders The ability to assign up to 30 transponders 6 Programming PIN CODE Programming of 4-digits PIN CODE (see function F6 description) F 1 - The immobilizer will be automatically armed after 3 minutes from turning the ignition off. F 2 - The immobilizer will be automatically armed after 30 seconds from turning the ignition off. F 3 - Turning the ignition on while the immobilizer is armed will immediately disconnect the locked circuits. F 4 - Turning the ignition on while the immobilizer is armed will disconnect the locked circuits with a 10 seconds delay. F 5 - Transponders should be assigned to device by placing them close to the antenna (once), with 4-second intervals for each transponder. You can assign max. 30 transponders to immobilizer. The immobilizer will automatically leave the assigning mode if it does not read any transponder for 5 seconds. You should assign all transponders the immobilizer is to read. This mode of transponder assigning does not modify the settings of the programmable functions. F 6 PIN CODE is programmed using the Authorization Switch (AS) after turnig the LED on. Example of programming the PIN CODE 1 2 3 4: FIRST DIGIT 1: Press AS 1 time, after 2 seconds the single buzzer signal confirms the digit was entered; SECOND DIGIT 2: Press AS 2 times, after 2 seconds the single buzzer signal confirms the digit was entered; THIRD DIGIT 3: Press AS 3 times, after 2 seconds the single buzzer signal confirms the digit was entered; FOURTH DIGIT 4: Press AS 4 times, after 2 seconds the single buzzer signal confirms the digit was entered. PIN CODE was changed. The LED goes off. FACTORY ASSIGNING TRANSPONDERS. Turning on the power supply with shorted pins as described on the picture will enter the mode of factory transponders assignment, which is signalled with a single, short buzzer sound. The assignment process involves placing transponders close to the antenna one by one, confirmed each time with a single, short buzzer sound. After all 30 transponders are assigned to the device or if it does not read any transponder for 5 seconds the assignment mode is automatically deactivated, which is signalled by a 5-second buzzer sound. This mode of transponders assignement modifies the settings of the programmable functions, resetting them to factory defaults. WHERE AND HOW TO INSTALL THE IMMOBILIZER The immobilizer main control unit should be mounted inside the vehicle cabin, preferably under the dashboard. You should avoid places exposed to humidity, e.g. areas near air-conditioning outlets, etc. The main control unit should be mounted to the vehicle fixed elements, using band clips. INSTALLATION OF THE RECEIVING ANTENNA To avoid the significant reduction of the transponder reading range, the receiving antenna should be installed

under the upholstery, in adequate distance from the vehicle metal parts. It is not permissible to shorten or lengthen the antenna. IINNSSTTAALLLL I AATTI IIOONN OOFF TTHHEE BBUUZZZZEERR The buzzer should be installed in a place that would assure good conditions for propagation of emitted sound signals. INSTALLATION OF THE LED The LED should be installed in a place clearly visible to the vehicle user. You should avoid places exposed to excess sunlight. INSTALLATION OF THE AUTHORIZATION SWITCH (AS) Authorization switch should be mounted in easily accessible though hidden place. CONNECTING THE IGNITION INPUT Connection should be made to the wire with +12/24VDC when the ignition is switched to the ON position. DESCRIPTION OF THE IMMOBILIZER INPUTS AND OUTPUTS: INPUTS. Antenna input - terminal of the antenna that generates low power electromagnetic field of the 125 khz frequency. Authorization switch input used for entering PIN CODE, triggered by providing ground, Ignition - ignition ON identification input, triggered by supply of +12/24V, +12/24V - main power supply input +12/24V, GROUND ground power supply. CONTROL OUTPUTS. Buzzer - control output providing +5V (max. 50mA), LED - control output providing +5V (max. 5mA), STATUS - control output providing ground level in active mode (max. 50mA), HORN - control output providing providing ground level in active mode (max. 50mA), CUT-OFF CIRCUITS - 2 independent NC (normally closed) circuits with load-carrying capacity of each circuit of 40A of constant current for 12V installation or 30A for 24V installation. TECHNICAL SPECIFICATIONS No.: Parameter Unit Value Remarks 1 Supply voltage V +12 do +24V +/-30% 2 Operating temperature range o C -30 do + 85 3 Current consumption at standby state Current consumption at disarmament state ma 10 50 4 Load-carrying capacity of outputs: Load-carrying capacity of NC contacts of the cut-off relays A 40 for U=12V 30 for U=24V 2 circuits Buzzer control ma 20 Pin 11 LED control ma 5 Pin 10 STATUS ma 50 Pin 13 HORN ma 50 Pin 12 5 Inputs impedance IGNITION kohm 4,7 Pin 15 AUTHORIZATION SWITCH kohm 20 Pin 14 6 Radio communication frequency khz 125 7 Communication range cm 6 8 Transponder type SYKOMAT IMMOBILIZER INSTALLATION DIAGRAM

Factory assigning the transponders