EMERGENCY EYEWASH PULL HANDLE TO ACTIVATE UNIT USH TO TIVATE HOWER www.bradleycorp.com USH S19-325BF S19-325FBF S19-325BF S19-325FBF S19-325PBF S19-325FPBF Barrier Free Recess-Mounted Drench Shower with Barrier Free Cabinet-Concealed Swing-Down Eye/Face Wash Table of Contents Pre- Information.... 2 Dimensions.... 3 Rough-Ins... 4 Instructions... 5 6 Drench Shower Components and Parts List... 7 Eye/Face Wash Components... 8 9 Eye/Face Wash Parts List.... 10 TO TIVATE HOWER www.bradleycorp.com 215-1619 Rev. F; ECN 14-05-006 2014 Bradley Page 1 of 10 5/12/2014 P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817 bradleycorp.com
R 114-051 Datum Signe P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA TEL: 1-800-BRADLEY FAX: (262-251-5817) http://www.bradleycorp.com S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF IMPORTANT Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer. THIS SIDE UP Packing List Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. P.O. Box 309, Menomonee Falls, WI 53051 TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement. Unterschrift Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be ON at all times. Provisions shall be made to prevent unauthorized shutoff. The ANSI Z358.1 standard requires an uninterrupted supply of flushing fluid. Bradley plumbed emergency fixtures require a minimum of 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI Z358.1. The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1. Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358.1. For questions regarding the operation or installation of this product, visit www.bradleycorp. com or call 1-800-BRADLEY. Product warranties and parts information may also be found under Products on our web site at www.bradleycorp.com. NOTICE! Avoid cleaners containing organic solvents, alcohols, and hydrocarbons. Rinse with water after cleaning. Local codes may require the installation of a backflow prevention valve to complete proper installation. Compliance with local codes is the responsibility of the installer. Valve must be tested annually to verify that it is functioning properly. Backflow prevention valves are not included with the fixture and may be supplied by the contractor or purchased from Bradley Corporation. 2 5/12/2014 Bradley 215-1619 Rev. F; ECN 14-05-006
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF Eye/Face Wash Cabinet Dimensions Side View Front View Side View ⁷ ₈" (22mm) 27⁵ ₈" (702mm) 6" (152mm) 1⁷ ₈" (48mm) 25½" (648mm) 33⁵ ₈" (854mm) 3¹ ₁₆" (78mm) Ø 1¼" (32mm) Waste Ø 1" (25mm) nominal copper tube supply Bottom View 1" (25mm) NPT to showerhead 22¾" (578mm) 15⁹ ₁₆" (395mm) 17⁷ ₁₆" 29⁷ ₁₆" (443mm 748mm) to floor for ANSI compliance 17⁷ ₁₆" 21⁷ ₁₆" (443mm 545mm) to floor for barrier free compliance 1¾" (44mm) Ø ¼" mounting hole (qty. 4) 22³ ₈" (568mm) 1¹ ₈" (29mm) 29¹ ₈" (740mm) 2¹ ₁₆" (52mm) 6³ ₈" (162mm) Bradley 215-1619 Rev. F; ECN 14-05-006 5/12/2014 3
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF 1 Rough-Ins ceiling hole Ø 1½" (38mm) ceiling hole Ø 5" (127mm) S19-325BF S19-325PBF S19-325FBF S19-325FPBF Piping and adequate supports by installer 4⁵ ₁₆" (110mm) 25" (635mm) min. 82 to 96" (2083mm to 2438mm) to floor Piping and adequate supports by installer 4⁵ ₁₆" (110mm) 25" (635mm) min. 6" (152mm) min. clearance 82 to 96" (2083mm to 2438mm) to floor Wall Opening 25⁵ ₈" (651mm) wide 32¹ ₈" (816mm) high 4 5/12/2014 Bradley 215-1619 Rev. F; ECN 14-05-006
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF 2 Piping and adequate supports by installer Piping and adequate supports by installer S19-325BF S19-325PBF Supplied by installer NOTE: Use teflon tape only. S19-325FBF S19-325FPBF NOTE: Use teflon tape only. Secure cabinet to wall, four places. Bradley 215-1619 Rev. F; ECN 14-05-006 5/12/2014 5
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF 3 Connect Water Supplly Mount safety sign to wall. To showerhead Connect 1" NPT supply piping Exploded view of valve and handle assembly 6 5/12/2014 Bradley 215-1619 Rev. F; ECN 14-05-006
R P.O. Box 309, Menomonee Falls, WI 53051 TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement. S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF Assembly of Components and Parts List for Drench Shower 150-212 (S19-325BF OR S19-325PBF) 169-1027 (S19-325BF or S19-325PBF) 114-052 Service Prepacks Datum Unterschrift Signe 204-421 113-864 (S19-325BF OR S19-325PBF) Valve Mounting Hardware Prepack (includes Valve Mounting Bracket, U-Bolt, Nuts and Washers) S45-2236 S24-189 (S19-325BF or S19-325PBF) S24-197 (S19-325FBF or S19-325FPBF) Screw Prepack (includes twelve screws and Torx Power Bit) S45-2245 Valve/Handle Prepack (includes Handle and Valve Assembly) S45-2237 Bradley 215-1619 Rev. F; ECN 14-05-006 5/12/2014 7
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF Assembly of Components for Eye/Face Wash (parts list on page 10) 1g 1s 1d 1k 1b 1e 1a Items 1a-1p and Items 15 17 come preassembled as Item 1. 1c 1f Shown in the ON position. 1h 1j 10 (Tailpiece) or 1p 1l 1m 1n 17 15 16 14 10 (Tubular Trap) 8 5/12/2014 Bradley 215-1619 Rev. F; ECN 14-05-006
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF Assembly of Components for Eye/Face Wash continued... 8 2 6 11 13 12 4 5 7 9 3 Bradley 215-1619 Rev. F; ECN 14-05-006 5/12/2014 9
S19-325BF, S19-325FBF, S19-325PBF, S19-325FPBF Parts List for Eye/Face Wash Item Part No. Qty. Description 1 S39-679 1 Swing-Down Sub-Assembly 1a S05-092 1 Eye/Face Wash Yoke Assembly 1b 113-1125 1 Pipe - Plated 1c 118-288 1 Valve Body - Plated 1d 125-120 1 O-Ring 1e 125-135 1 O-Ring 1f 192-016 1 Insert, Direction - Plated 1g 160-413 1 Screw, Set 1h S39-598 1 Actuator Sub-Assembly - Valve 1i 132-047 1 Insert, Flow Control 1j 125-001CS 1 O-Ring 1k 125-032 1 Flow Control 1l 110-115A 1 Hex Nut - Plated 1m 125-001DA 1 O-Ring 1n 131-082 1 Base Item Part No. Qty. Description 2 S39-691 1 Cabinet Assembly 3 S45-2196 1 Handle/Hardware Kit 4 S45-2197 1 Swing-Down Stop Kit 5 269-1836 2 Rod End 6 182-1181 Spacer 7 140-949 1 Bracket, Swing-Down 8 204-602 1 Decal, Pull Down Eyewash 9 204-603 1 Decal, Concealed Eyewash 10 269-1830 1 Tailpiece or 269-142 1 Tubular Trap, 1-1/4" 11 269-18351 Gas Spring 12 160-264 1 Bolt, 5/16"-18 x 1" 13 160-4581 Bolt, 5/16"-18 x 3/4" 14 S27-102 1 Stop Valve 1p 160-428 1 Screw, Set 15 169-348 1 Union 1q 113-1058 1 Shank 16 169-639 1 1/2" Elbow, 90 1r 110-115 1 Hex Nut 17 142-002CB 1 Washer 1s S05-158 1 Eye/Face Wash Assembly 10 5/12/2014 Bradley 215-1619 Rev. F; ECN 14-05-006