Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Similar documents
Technical Manual. DLM Module. This manual should remain with the unit.

Owner's/Installation Manual

Owner's Manual 600 and 800 Amp RTS Automatic Transfer Switch

Owner's Manual. GenReady Load Center and Transfer Switch. This manual should remain with the unit. Model Numbers. GenReady Basic Panelboard

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

Owner's Manual Nexus Smart Switch

Technical Manual. Nexus Smart Switch. This manual should remain with the unit.

Owner's Manual. GenReady Multi-breaker Load Center and Transfer Switch. or GENERAC. This manual should remain with the unit.

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Automatic Transfer Switch

Owner s Manual. For Automatic Transfer Switch. PowerPact Home Standby Generator MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

BATTERY CHARGER CHR-1445

Owner's Manual. 400 Amp RTS Automatic Transfer Switch. or GENERAC

POWER SYSTEMS, INC. Owner s Manual. 100 Amp V Type. Transfer Switch Models: This manual should remain with the unit.

POWER SYSTEMS, INC. Owner s Manual. GTS W Type. Automatic Transfer Switch. 200 Amp, 250 Volts. Model This manual should remain with the unit.

RTS Automatic Transfer Switch TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

POWER SYSTEMS, INC. Owner s Manual. Integrated Load Center. 200 Amp, 600 Volts. This manual should remain with the unit.

Owner's Manual. This manual should remain with the unit.

RTS Automatic Transfer Switch TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

RTSS Load Shed Automatic Transfer Switch. Model No. KGALT TECHNICAL MANUAL. This manual should remain with the unit.

Automatic Transfer Switch

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance / Non-Service Entrance

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit.

Emergency Automatic. Backup Power System. The BASIC How-To Installation Guide For The Do-It-Yourselfer

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Automatic Transfer Switch

R-200A R-200B Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance / Non-Service Entrance

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

R-100 Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Sentry Battery Charger. Installation and Operations Manual Section 75

POWER SYSTEMS, INC. Owner s Manual. GTS W Type. Automatic Transfer Switch. 200 Amp, 250 Volts

Carrier Liquid-cooled Generators

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

INSTALLATION GUIDELINES

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

Switching DC Power Supply

User s Manual. Automatic Switch-Mode Battery Charger

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

ELECTRICAL SAFETY-RELATED WORK PRACTICES

High Frequency SineWave Guardian TM

rechargeable umbrella light

MASTERsine Inverter PXA Series Installation Guide

AC CONVERTER / BATTERY CHARGER

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Go Power! Manual. GP-Smart Charger

Rental Industry Safety Tester Safe Check 5s

Powered Industrial Trucks

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Automatic Transfer Switch

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

8300 Series Installation Guidelines

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AVOIDING ELECTROCUTION HAZARDS

MANUAL FOR ROTARY ACTUATORS ABSTRACT. Doc #SED-MAN-Rotary Actuators-002. Date: 11-Sep-2017

Power Inverter 400 MW Owner s Manual

5300 Series Installation Guidelines

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Compact Sine Inverter

AUTO CHARGE D PUMP PLUS

Wind and Temperature Tip Over Hazard Do not add notice boards or similar

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

BATTERY SAVER LOW RIPPLE HO

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Guardian Battery Charger Series. Installation and Operations Manual Section 75

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

DISCHARGER-ANALYZER BDX USER'S MANUAL

User Manual. Solar Charge Controller 3KW

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

GSL Electronics Modified Sine Wave Power Inverters

General Precautions. Personnel Precautions

Owner s Manual. 8, 10, 12, 14, 16, 17 & 20kW Air-cooled, Automatic Standby Generators DO NOT LIFT UNIT BY ROOF!

AUTO CHARGE LPC SERIES

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

FJC, Inc. Part # V BATTERY Charger/Maintainer INSTRUCTION MANUAL SAFETY WARNINGS AND PRECAUTION

POWER INVERTER 1,000 WATT / 2,000 WATT PEAK

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

LESTRONIC II BATTERY CHARGER MODEL 07210

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Owner's Manual. DC-AC Power Inverter. Models: (750W) (400W) (200W) or GENERAC

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

INTELLIGENT BATTERY CHARGER/MAINTAINER

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Transcription:

CHR-1285/2485 BATTERY CHARGER TEL:886-4-2238-0698 FAX:886-4-2238-0891 Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw Copyright 2007 Monicon Instruments Co., Ltd. All right reserved. Contents in this publication may not be reproduced in any form without the expressed written permission of Monicon Instruments Co., Ltd. Precaution: This manual contains important instructions that should be followed during

installation and maintenance of the generator and batteries. Precaution: Read the following information carefully before attempting to install, operate or service this equipment. Also read the instructions and information on tags, decals, and labels that may be affixed to the transfer switch. Replace any decal or label that is no longer legible. Warning: Connection of a generator to an electrical system normally supplied by an electric utility shall be by means of suitable transfer equipment so as to isolate the electric system from utility distribution system when the generator is operating. Failure to isolate electric system by these means may result in damage to generator and may result in injury or death to utility workers due to back feed of electrical energy. Monicon Instrument, Inc., hereafter referred to as the manufacturer, cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive. If using a procedure, work method or operating technique the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique chosen does not render the battery charger unsafe. Throughout this publication, and on tags and decals affixed to the battery charger, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows: Three commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates follows: After this heading, read instructions that, if not strictly complied with, will result will result in personal injury, including without limitation, death, or property damage.

After this heading, read instructions that, if no strictly complied with, may result in personal injury or property damage. Caution After this heading, read instructions that, if not strictly complied with, could result in damage to equipment and/or property. NOTE: After this heading, read explanatory statements that require special emphasis. These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents. GENERAL HAZARDS Improper or unauthorized installation, operation, service or repair of the equipment is extremely dangerous and may result in death, serious personal injury, or damage to equipment and/or personal property. Extremely high and dangerous power voltages are present inside an installed battery charger. Any contact with high voltage terminals, contacts or wires will result in extremely hazardous, and possibly LETHAL, electric shock. DO NOT WORK ON THE BATTERY CHARGER UNTIL ALL POWER VOLTAGE SUPPLIES TO THE SWITCH HAVE BEEN POSITIVELY TURNED OFF. IMPORTANT SAFETY INSTRUCTIONS Competent, qualified personnel should install, operate and service this equipment. Adhere strictly to local, state and national electrical and building codes. When using this equipment, comply with regulations the National Electrical Code (NEC), CSA Standard; C22.1 Canadian Electric Code and Occupational Safety and Health Administration (OSHA) have established.

Never handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT. Jewelry conducts electricity and wearing it may cause dangerous electrical shock. Remove all jewelry (such as rings, watches, bracelets, etc.) before working on this equipment. If work must be done on this equipment while standing on metal or concrete, place insulated mats over a dry wood platform. Work on this equipment only while standing on such insulated mats. Never work on this equipment while physically or mentally fatigued. Keep the battery charger enclosure closed and bolted at all times. Only qualified personnel should be permitted access to the charger interior. In case of an accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor but AVOID DIRECT CONTACT WITH THE VICTIM. Use a non-conducting implement, such as a dry rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help. When a battery charger is installed for a standby generator set, the generator engine may crank and start at any time without warning. To avoid possible injury that might be caused by such sudden start-ups, the system s automatic start circuit must be disabled before working on or around the generator or battery charger. For that purpose, a SAFETY DISCONNECT is provided inside the controller panel. Always set that control panel to its OFF position before working on the equipment. Then place a DO NOT OPERATE tag on the battery charger and on the generator. Remove the Negative (Neg) or ( ) battery cable.

Table of Content 1. Descriptions...5 2. Features...5 3. Specifications...6 4. Installation and Operation...6 5. Notes...6 6. Dimension...7 7. Safety Precautions...8 1. Descriptions CHR-1285/2485, intelligence module, serves lead acid battery at full charging all the time. Short-circuit, Over load, and Over Voltage Protection prevent any damage from lead acid battery. Widely AC input voltage and adjustable DC output voltage realize the ideal of high flexibility. CHR-1285/2485 also in accordance with the principle of high Efficiency at the ratio: at Full Loaded >85% saving more energy due to the high- tech design. Easy operation reduces the time and cost for the client. 2. Features -Short circuit protection -Overload protection -Boost charge input -Float charging system -Constant voltage output -Current limited

-Rugged design for industrial environments -Wide operating voltage range 3. Specifications AC Input Voltage: DC adjustable output voltage range: Voltage 80~250VAC (110/220 VAC) CHR-1285 Voltage 12-14VDC Frequency 50/60HZ CHR-2485 Voltage 25-27VDC Changing algorithm: Protection: Constant voltage then constant current Over Voltage, Over Current, Short Circuit Protection Efficiency: Working Temperature: at Full Loaded >85% -30~70 Storage Temperature: Relative humidity: -40~85 Max. 90 % Dimension: Weight: 147mmL*82mmW*43mmmH 482.2g Specifications subject to change without notice 4. Installation and Operation 4.1. Line on the L1 and L2 with AC power. Note: there is no AC volt output before line on with the battery. 4.2. Turn off the AC power then put the + and pole of charger with the + and pole of battery together then turn on the AC current. 4.3. Included Self-detected charging circuit that automatically shut down charging when battery is filled. Never turn off the power or line off with battery. 4.4. Build-in short circuit and reverse polarity protection. 5. Notes: 5.1. All the adjustment has regulated at factory before ex-work.

5.2. In charging state, because lead-acid batteries will gas, please located it on well- ventilated storage. 5.3. Avoiding the place of raining, exposing, non-neutralization or existing corrosive gas. 5.4. Battery detected voltage must over 10V(or 21V) otherwise the charger stop charging automatically. 5.5. Charger only for battery charging 6. Load indication 6.1.Four light indicator shows the load of the battery charger, with the following 1 light on: low load 2 light on: half load 3 light on: full load Red light on: unloaded indicated with no charge 7. Label 8. Dimension

9. Safety Precautions When operating your battery charger, basic safety precautions should always be followed to reduce the potential risk of fire, electric shock and/or injury to persons, including the following: 9.1. Read this owner s manual thoroughly before operating your battery charger. 9.2. Do not allow any objects or liquid into the openings of your battery charger.

9.3. Do not place any flammable materials such as gasoline near your battery charger. 9.4. Do not cover or obstruct ventilating opening of your battery charger. Overheating may result. 9.5. To reduce the risk of fire or electric shock, do not remove any service covers. No user s serviceable parts are inside. Repair should be done by your dealer s authorized personnel only. 9.6. If you have any questions or comments about this product, please contact your local dealer for assistance. CAUTIION: To prevent fire, do not cover or obstruct ventilation openings. Do not mount in zero-clearance compartment. Overheating may result. CAUTIION: The protection of overload or any fault condition in each output circuit is operated by current fuse. These fuses of output circuit are located in the above printed wiring board. CAUTIION: Disconnect supply before changing fuse. Monicon Instrument Co. Ltd. reserves the right to change specification without prior notice.