SPLIT SYSTEM HEAT PUMP 12 SEER

Similar documents
SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED

LISTED TECHNICAL GUIDE STELLAR 2000 TM

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE LISTED

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

R-22, 13 SEER 60 Hertz

LISTED TECHNICAL GUIDE

SINGLE PACKAGE HEAT PUMPS

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL GUIDE LISTED

DESCRIPTION FEATURES

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

R4H4. Product Specifications

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

HP19 Bulletin No August 1994 Supersedes November 1993

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

HEAT PUMPS UPKB- SERIES. Seven Models

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

Q7RE Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase

E4FH, E5FH SERIES 12 SEER HEAT PUMP

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

HCH6. Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

4SHP18LS PRODUCT SPECIFICATIONS

Product Data. 38YCB 50 Hz Heat Pump. 38YCB Sizes 024 thru 060 FEATURES/BENEFITS

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION

10AC DIPLOMAT SERIES RFC SYSTEMS

4SHP18LS. Product Specifications. 18 SEER Split System Enhanced Heat Pump COMPONENTS COMPRESSOR CABINET DESIGN WARRANTY COIL

TECHNICAL GUIDE R-410A AFFINITY SERIES BHZ MODELS 2-5 TON 60 Hertz

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

13 HP x

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

PHB SERIES 7-1/2 and 10 TON

Transcription:

515.18-TG1C (600) SPLIT SYSTEM HEAT PUMP 12 SEER 018 thru 060 1.5 thru 5 NOMINAL TONS GENERAL DESCRIPTION The series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or horizontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. FEATURES Durable Construction - The outdoor unit is constructed of pre-painted steel that offers tough protection against corrosion and resists fading when exposed to sunlight. Drain holes are incorporated into the base pan to permit free drainage of moisture. Quality Coil - The black outdoor coil is constructed of copper tube and aluminum fins for durability. Coil guard provides additional protection when installed in a heavy traffic area. Protected Compressor - The hermetic compressor is internally protected against high pressure and temperature by the simultaneous operation of a high pressure relief valve and temperature sensors which stop the compressor if operating temperatures go too high. Both protectors reset automatically. A discharge line solid core filter drier further protects the compressor. Time Temperature defrost control includes a five-minute anti-short cycle timer to protect the compressor from short cycling. Field selectable 30, 60, 0 minutes defrost intervals. Low Operating Sound Level - The compressor is mounted on rubber isolators to reduce operating sounds. The slow moving condenser fan keeps air turbulence and sound to a low level. Easy Access - Removable panel affords accessibility to the electrical box. Fully charged and factory wired - to simplify installation and reduce labor costs. Only power supply and control wiring and refrigerant lines must be connected. All models are sweat connect with re-usable service valves. Factory tested - to verify system operation and control functioning before shipment. U.L. and C.U.L. listed - approved for outdoor application. ARI certified - to comply with ARI standard 240 for rating air cooled heat pump units. Single phase - one (1) year limited parts warranty to original registered owner. Ten (10) year warranty for compressor. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

515.18-TG1C COOLING CAPACITY - With Air Handler Coils AIR HANDLER COIL 2 COOLING * ELECTRIC RATED NET MBH W KW SEER SEER/ HEAT KW CFM TOTAL SENS. TXV 1 EER / NXAH (Standard) 0181BD NXAHB08 2,5,8,10 17 GBFD024S17 800 17.8 12.8 1.72 -- 12.00 10.35 0241BD NXAHB08 2,5,8,10 17 GBFD024S17 800 23.4 17.3 2.28 -- 12.005 10.25 NXAHB08 2,5,8,10 17 GBFD030S17 850 23.8 17.6 2.30 -- 12.10 10.35 0301BD NXAHB12 5,8,10,15,18 17 GBFD030S17 1025 27.8 20.6 2.71 -- 11.65 10.25 NXAHB12 5,8,10,15,18 17 GBFD036S17 1025 28.0 20.7 2.72 -- 12.00 10.30 0361BD NXAHB12 5,8,10,15,18 17 GBFD036S17 1250 33.4 24.7 3.31 12.00 12.10 10.10 0421BD NXAHC16 5,8,10,15,20 21 GBFD042S21 1400 40.0 3.83 12.00 -- 10.45 NXAHC16 5,8,10,15,20 21 GBFD048S21 1450 40.5 30.0 3.80 -- 12.00 10.65 NXAHC16 5,8,10,15,20 21 GBFD048S21 1600 45.5 33. 4.25 -- 12.00 10.70 0481BE NXAHD20 8,10,15,20,25,30 24 GBFD060S24 1600 46.5 34.6 4.27 -- 12.00 10.0 NXAHD20 8,10,15,20,25,30 24 GBFD061H24 1600 47.0 35.1 4.27 -- 12.00 11.00 0601BE NXAHD20 8,10,15,20,25,30 24 GBFD060S24 1700 57.5 40.4 5.35 -- 12.00 10.75 NXAHD20 8,10,15,20,25,30 24 GBFD061H24 2000 5.0 44.0 5.46 -- 12.00 10.80 / NXVS - (Variable Speed) 018 NXVSB12 5,8,10,15,18 17 GBFD024S17 800 18.4 13.2 1.60 13.00 -- 11.80 024 NXVSB12 5,8,10,15,18 17 GBFD030S17 850 24.4 18.1 2.10 13.00 -- 11.50 030 NXVSB12 5,8,10,15,18 17 GBFD036S17 1025 28.6 21.2 2.60 13.00 -- 11.20 036 NXVSB12 5,8,10,15,18 17 GBFD036S17 1200 34.0 25.2 3.10 13.00 -- 11.00 NXVSB16 5,8,10,15,20 17 GBFD046S17 1250 34.6 25.6 3.10 13.00 -- 11.00 042 NXVSC16 5,8,10,15,20 21 GBFD048S21 1450 41.5 30.7 3.80 13.00 -- 11.00 048 NXVSD20 8,10,15,20,25,30 24 GBFD060S24 1605 47.5 36.0 3.8 1 -- 12.20 NXVSD20 8,10,15,20,25,30 24 GBFD061H24 1605 48.0 36.3 3.0 1 -- 12.30 060 NXVSD20 8,10,15,20,25,30 24 GBFD060S24 1860 5.0 43.5 4.6 1 -- 11.0 NXVSD20 8,10,15,20,25,30 24 GBFD061H24 180 60.0 45.4 5.00 1 -- 12.00 AIR HANDLER COOLING COIL * 2 ELECTRIC RATED NET MBH W KW SEER SEER/ HEAT KW CFM TOTAL SENS. TXV 1 EER / F*RP / F*FP 0181BD FYRP/FP024 5,8,10 18 -- 650 13.3 1.71 12.00 -- 10.50 0241BD FYRP/FP030 5,8,10,15 18 -- 800 23.6 17.5 2.25 12.00 -- 10.50 0301BD FYRP/FP036 5,8,10,15 18 -- 1035 28.6 21.2 2.70 12.00 -- 10.60 0361BD FYRP/FP036 5,8,10,15 21 -- 1250 34.0 25.2 3.27 12.00 -- 10.40 FYRP/FP042 5,8,10,15 21 -- 1250 34.0 25.2 3.27 12.00 -- 10.40 0421BD FYFP/FP042 5,8,10,15 21 -- 1400 3.5 2.2 3.85 -- 11.70 10.25 FYFP048 10,15,20,25 24 -- 1400 41.0 30.3 3.87 12.00 -- 10.60 FYFP045 5,8,10,15 24 -- 1500 46.0 33.5 4.18 12.00 -- 11.00 0481BE FYFP048 10,15,20,25 24 -- 1600 45.5 33.7 4.31 -- 12.00 10.55 FYFV060 10,15,20,25 24 -- 1605 47.5 35. 3.1 1 -- 12.15 0601BE FYFP060 10,15,20,25 24 -- 1700 57.0 3. 5.48 -- 12.00 10.40 FYFV060 5,8,10,15 24 -- 1860 5.0 43.4 4.6 1 -- 11.0 Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standards 210/240. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 5 F outdoor ambient divided by the total electric power in watthours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1 1TV0700 Series = Thermal Expansion Valve Kit Required. Must be used with Hard Start Assist. (Hard Start not required with scroll compressor.) 2 Refer to coil installation guide for proper coil application. 3 G8T, L8T, or GT furnaces and FRP/FRC air handlers have B.O.D. standard (included in performance rating). 4 To meet R=4.2 insulation requirements, substitute and FYFP for FYRP models. All ratings remain the same. 5 Requires 2FD fan time delay. * All models are single phase, unless noted otherwise. ** Field transition may be required. -- = Not Applicable. 2 Unitary Products Group

COOLING CAPACITY - With Upflow, Downflow & Horizontal Furnace and Coils FURNACE** COIL 2 COOLING NOMINAL AIRFLOW W RATED NET MBH SEER/ KW SEER EER CFM TOTAL SENS. TXV 14,17 GXUA024S14,17 650 17.6 13.0 1.70 11.70* -- 10.30 0181BD 1000 14 GXUA030S14 650 17.6 13.2 1.70 11.85* -- 10.40 14,17 GXFD024S14,17 650 17.8 13.2 1.70 -- 12.00 10.35 14 GXUA030S14 850 23.0 17.0 2.20 -- 12.00 10.25 14 GXUA036S14 800 23.8 17.6 2.30 -- 12.00 10.35 17,21 GXUA036S17,21 800 23.8 17.6 2.30 -- 12.00* 10.35 0241BD 14,17 GXFD024S14,17 800 23.4 17.3 2.30 -- 12.00 10.25 800 17 GXFD030S17 800 23.8 17.6 2.30 12.00 12.10 10.35 1000 1200 14 GXFD035S14 800 23.8 17.6 2.30 12.10 -- 10.35 -- GXHD024S 800 23.7 18.7 2.30 -- 12.20 10.37 -- GXHD036S 800 26.6 1.0 2.31 12.00 -- 10.51 -- GXNF036SOF 800 23.0 17.0 2.20 12.00* -- 10.50 17 GANA030S17K 850 22. 16. 2.30 12.00 -- 10.0 0301BD 0361BD 0421BD 0481BE 1000 1200 1400 1200 1400 1600 1400 1600 2000 1600 2000 515.18-TG1C 14 GXUA036S14 1000 28.2 20.4 2.72 11.50* -- 10.35 17,21 GXUA036S17,21 1025 27.8 20.6 2.70 11.50* -- 10.25 14,17 GXFD030S17 1000 27.8 20.6 2.70 11.50* 11.65 10.25 14 GXFD035S14 1000 27.8 20.6 2.70 11.70 -- 10.30 -- GXNF036SOF 1025 2.0 21.5 2.30 12.00* -- 12.70 21 GXFD036S21 1025 28.0 20.7 2.70 -- 12.00 10.55 17 GXFD036S17 1025 28.0 20.7 2.70 11.80* 12.00 10.30 -- GXHD036S 1000 28.2 22.4 2.73 -- 12.00 10.11 -- GXHD048S 1025 2.3 23.3 2.75 12.15 -- 10.68 -- GXNF036SOF 1200 33.6 24. 3.30 12.00* -- 10.20 21,24 GXUA048S21,24 1250 25.8 3.30 12.20* -- 10.50 21 GXFD042S21 1225 34.2 25.3 3.30 12.10* 12.20 10.30 21 GXFD036S21 1225 34.0 25.2 3.30 -- 12.15 10.35 17 GXFD036S17 1225 33.4 24.7 3.30 12.00* 12.10 10.10 -- GXHD036S 800 33.4 26.4 3.31 -- 12.00 10.11 -- GXHD048S 800 36.0 27. 3.43 12.00 -- 10.4 -- GXNF048SOF 1400 40.5 30.0 3.0 12.00* -- 10.50 -- GXHD048S 1400 40.6 31.5 3.83 12.00 -- 10.60 21,24 GXUA048S21,24 1425 40.5 30.0 3.80 12.00* -- 10.65 21 GXFD042S21 1400 40.5 30.0 3.80 12.00 -- 10.65 21,24 GXFD048S21,24 1425 40.5 30.0 3.80 -- 12.00 10.65 24 GXFD060S24 1450 41.0 30.3 3.80 12.10* 12.30 10.0 -- GXNF060SOF 1600 46.0 34.0 4.20 12.00* -- 11.00 -- GXHD060S 1600 46.0 34.1 4.26 12.00 -- 10.80 21,24 GXFD048S21,24 1600 45.0 33.3 4.00 12.00* 12.00 11.35 21,24 GXUA048S21,24 1500 45.5 33.0 4.21 12.10* -- 10.80 21,24 GXUA060S21,24 1620 46.0 34.0 4.10 12.10* -- 11.30 24 GXFD060S24 1620 46.5 34.4 4.00 12.20* 12.40 11.55 24 GXFD061H24 1605 48.0 36.3 3.0 1 -- 12.30 21,24 GXUA060S21,24 1700 57.5 40.4 5.35 12.00 -- 10.75 -- GXNF060SOF 1800 58.0 40.5 5.37 12.00 -- 10.80 0601BE 2000 24 GXHD060S 1800 57.0 40.7 5.38 12.00 -- 10.60 24 GXFD060S24 1700 57.5 40.4 5.35 12.00 -- 10.75 24 GXFD061H24 2000 5.0 44.0 5.46 12.00 -- 10.80 * Requires 2FD fan time delay. ** Refer to Quick Selection Chart for specific furnace match-up. Note: GXNF coils apply to the P1WH outdoor furnace only. SOUND RATINGS SOUND RATINGS BELS SOUND RATINGS BELS 018 8.0 042 8.0 024 8.0 048 TBD 030 8.0 060 TBD 036 8.0 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYS- TEM IS LISTED WITH ARI Unitary Products Group 3

515.18-TG1C HEATING PERFORMANCE - / AIR HANDLERS and MULTI-POSITION COILS * 0181BD 0241BD 0301BD 0361BD 0421BD 0481BE COIL 1 ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD V.S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW FYRP/FP024 1.0 3.20 10.6 2.05 7.2 -- GXFD024S14,17 18.8 3.40 10.6 3.04 7.0 7.1 7.2 1.44 8. 1.47 10.6 1.52 13.0 1.63 14.8 1.58 1.65 1.3 1.71 FYRP/FP030 24.0 3.15 14.0 2.05 7.3 --.1 1.75 1.3 1.86 14.0 2.00 15.8 2.08 21.1 2.13 24.0 2.23 27.1 2.32 GXFD024S14,17 23.6 3.04 13.8 2.02 7.2 -- 7.8 1.80 10.8 1.0 13.8 2.00 16.8 2.10 20.1 2.1 23.4 2.26 27.3 2.36 GXFD030S14,17 7.3 7. 1.81 11.0 1.0 14.0 1. 17.8 2.08 20.3 2.60 23.6 2.22 27.7 2.31 23.6 3.12 14.0 2.06 7.3 GXFD035S14 -- 8.0 1.82 11.0 1.0 14.0 1. 17.0 2.08 20.3 2.16 23.6 2.22 27.6 2.31 FYRP/FP036 3.40 2.30 8.0 -- 11.6 2.02 15.0 2.22 2.2 20.2 2.34 26.0 2.43 2.55 33. 2.68 GXFD030S17 3.36 2.28 8.0 -- 10.2 2.10 14.1 2.21 2.31 21. 2.42 26.1 2.52 2.58 35.2 2.78 GXFD035S14 3.26 2.28 8.0 -- 10.3 2.04 14.2 2.18 2.31 21.8 2.45 26.0 2.57 2.66 35.2 2.86 GXFD036S17 30.0 3.40 18.2 2.30 8.0 8.1 10.3 2.10 14.2 2.21 18.2 2.32 22.2 2.45 26.4 2.52 30.0 2.5 35.8 2.77 GXFD036S21 3.40 18.2 2.30 8.0 -- 10.5 2.13 14.4 2.22 18.2 2.32 22.0 2.41 26.1 2.50 2.55 35.1 2.74 FYRP/FP036 -- 12.1 2.26 15. 2.40 20.6 2.62 25.0 2.86 30.8 2.7 35.0 2.3 3.6 3.12 35.0 20.6 2.30 8.0 FYRP/FP042 -- 10.4 2.26 15.5 2.4 20.6 2.63 25.7 2.76 31.3 2.8 35.0 2.3 40.8 3.13 GXFD036S17 35.4 3.54 2.20 8.0 8.1 10.6 2.61 15.7 2.6 2.77 25. 2.85 31.6 2.3 35.4 2.3 41.1 3.03 GXFD046S17(*) 35.4 3.60 2.40 8.1 8.1 10.4 2.24 15.6 2.3 2.54 26.0 2.6 31.7 2.83 35.4 2.88 41.2 3.10 GXFD036S21 35.0 3.46 20.4 2.16 7.8 -- 10.1 2.56 15.2 2.66 20.4 2.77 25.6 2.87 31.2 2.6 35.0 2.6 40.7 3.14 GXFD042S21 35.4 3.52 2.30 8.0 -- 10.6 2.40 15.7 2.52 2.65 25. 2.78 31.6 2.0 35.4 2.5 41.1 3.0 FYRP/FP042 41.5 3.38 25.2 2.30 8.0 -- 14.7 2.3 20.0 3.07 25.2 3.21 30.4 3.35 36.2 3.47 41.5 3.60 48.1 3.78 FYFP048 42.0 3.60 2.38 8.0 -- 14.8 2.3 20.1 3.04 25.5 3.14 30. 3.24 36.7 3.33 42.0 3.42 48.8 3.54 GXFD042S21 42.0 3.58 2.36 8.0 -- 14.5 2.0 1. 3.04 25.2 3.18 30.5 3.32 36.3 3.45 41.5 3.56 48.1 3.71 GXFD048S21,24 42.0 2.36 8.0 8.1 14.8 2.1 20.1 3.03 3.15 30.7 3.27 36.6 3.3 42.0 3.52 48.8 3.6 GXFD060S24 42.0 3.58 2.36 8.0 -- 14.6 2.3 20.0 3.04 3.15 30.8 3.27 36.6 3.36 42.0 3.44 48.8 3.56 F+FP045 47.0 3.22 2.4 2.40 -- 17.7 3.13 23.5 3.36 2.4 3.5 33.7 3.71 37. 3.78 47.0 4.28 52. 4.3 F+FP048 47.5 3.18 30.0 2.40 -- 18.3 3.1 24.2 3.42 30.0 3.66 34.3 3.76 38.6 3.86 48.0 4.38 53.3 4.62 F+FV060 46.0 3.34 28.4 2.54 -- 8.25 16.7 2.77 22.5 3.02 28.4 3.28 32.7 3.40 37.0 3.52 46.0 4.04 51. 4.2 GXFD048S21 47.5 3.22 2.8 2.42 -- 3.11 23. 3.36 26.8 3.61 34.1 3.71 38.4 3.81 48.0 4.35 53.4 4.60 GXFD048S24 47.5 3.16 2.38 7.5 -- 17.7 3.0 23.6 3.35 3.61 34.0 3.74 38.4 3.86 48.0 4.40 53.5 4.67 GXFD060S24 46.0 3.34 28.4 2.54 -- 8.25 16.7 2.77 22.5 3.02 28.4 3.28 32.7 3.40 37.0 3.52 46.0 4.04 51. 4.2 GXFD061H24 45.0 3.30 28.6 2.56 -- 8.25 17.7 2.7 23.1 3.03 28.6 3.27 32.6 3.3 36.6 3.51 45.0 4.00 50.5 4.24 F+FP060 5.0 3.40 35.2 2.30 7.75 -- 1.3 3.6 27.3 4.18 35.2 4.41 38.8 4.45 42.5 4.4 5.0 5.08 66. 5.31 F+FV060 57.5 3.80 33.6 2.50 8.25 -- 17.7 3.61 25.6 3.77 33.6 3.4 37.2 3.4 40. 3.5 57.5 4.43 65.5 4.60 0601BE GXFD060S24 58.5 2.40 -- 1.0 3.82 26. 4.03 4.25 38.6 4.31 42.3 4.36 58.5 4.0 66.4 5.11 GXFD061H24 5.5 35.6 2.40 -- 1.7 3.86 27.6 4.0 35.6 4.31 3.2 4.35 42. 4.3 5.5 4.8 67.5 5.21 Note: (*) GXFD046S17 coil only listed as a variable speed match. This is not an approved furnace coil match. 1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. 4 Unitary Products Group

HEATING PERFORMANCE - / UPFLOW FURNACE & COILS * 0181BD 0241BD 0301BD 0361BD 0421BD 0481BE 0601BE COIL 1 ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F -3 F 7 F 17 F 27 F 37 F 47 F 57 F HSPF MBH COP MBH COP MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW GXUA024S14,17 18.8 3.14 10.4 2.02 7.00 5.0 1.33 7.7 1.42 10.4 1.50 13.1 1.5 15.8 1.67 1.75 21.8 1.84 GXUA030S14 1.0 3.22 10.4 2.04 7.10 4.8 1.33 7.6 1.41 10.4 1.4 13.2 1.57 16.0 1.65 1.0 1.73 22.0 1.81 GXNF036SOF 23.0 3.10 13.0 2.00 7.00 6.60 1.70.8 1.80 13.0 1.1 16.2 2.01 1.5 2.10 23.0 2.17 27.2 2.2 GXUA030S14 23.4 3.04 13.8 2.02 7.20 7.80 1.80 10.8 1.0 13.8 2.00 16.8 2.10 20.1 2.1 23.4 2.26 27.3 2.36 GXUA036S14 23.6 3.12 14.0 2.06 7.30 7.0 1.80 11.0 1.0 14.0 1. 17.0 2.0 20.2 2.16 23.6 2.22 27. 2.30 GXHD024S 23.4 3.0 13.8 2.05 7.20 7.70 1.78 10.7 1.88 13.8 1.7 16. 2.07 20.1 2.15 23.4 2.22 27.5 2.32 GXHD036S 23.6 3.12 14.0 2.06 7.30 7.0 1.80 11.0 1.0 14.0 1. 17.0 2.0 20.2 2.16 23.6 2.22 27. 2.30 GXUA036S17,21 23.6 3.12 14.0 2.06 7.30 7.0 1.81 11.0 1.0 14.0 1. 17.0 2.08 20.3 2.16 23.6 2.22 27.7 2.34 GANA030S17K 24.3 3.05 15.0 2.16 7.30 10.0 1.58 12.2 1.6 15.0 1.72 18.7 1.81 22.0 1.2 24.3 2.02 28.5 2.25 GXUA036S17,21 GXUA036S14 GXHD036S GXHD048S GXNF036SOF GXUA048S21,24 GXHD036S GXHD048S GXNF036SOF GXUA048S21,24 GXHD048S GXNF048SOF GXUA048S21,24 GXHD060S GXUA060S21,24 GXNF060SOF GXUA060S21,24 GXHD060S GXNF060SOF 2.8 30.0 30.3 28.6 35.8 35.4 35.4 33.2 42.0 42.0 41.0 47.5 46.5 47.0 46.0 58.5 58.5 57.0 3.36 3.40 3.54 3.00 3.58 3.56 3.5 3.10 3.55 3.30 3.24 3.24 3.30 3.10 3.20 18.2 18.2 18.3 27.4 2.0 2.8 35.0 2.28 2.28 2.35 2.36 1.0 2.32 2.21 2.22 1.56 2.36 2.38 2.50 2.40 2.38 2.36 2.42 2.40 2.40 2.30 7.00 7.00 7.5 7.0 7.70 10.2 10.5 10.3 10.3 10. 0.4 10.4 10.4 7.30 14.6 14.7 18.7 17.7 18.3 17.6 1.0 2.10 2.1 2.07 2.08 2.72 2.37 2.58 2.58 3.47 2.4 2.8 2.2 3.16 3.27 3.21 3.0 14.1 14.3 14.2 14.3 14.4 15.6 15.6 15.6 12.6 20.0 20.0 23.1 23.6 24.0 23.3 24.4 2.21 2.26 2.17 2.17 2.75 2.50 2.67 2.66 3.43 3.05 3.01 3.07 3.3 3.46 3.40 3.34 18.2 18.2 18.3 27.4 2.0 2.8 2.31 2.34 2.27 2.27 2.78 2.63 2.76 2.75 3.38 3.15 3.13 3.21 3.61 3.64 3.60 3.5 21. 22.2 22.3 21.6 26.0 26.0 26.0 23.4 30.8 30.8 31.7 34.0 33.7 34.7 33.8 2.42 2.31 2.37 2.37 2.80 2.76 2.85 2.83 3.34 3.26 3.24 3.36 3.70 3.71 3.80 3.72 26.1 23.3 26.4 26.6 31. 31.6 31.7 2.2 36.7 36.6 36.6 38.4 37. 40.8 37.7 1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of intonnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. 1.0 1.0 22.0 3.82 3.88 4.07 26. 2. 28.4 4.03 4.08 4.25 4.25 4.28 4.43 38.6 38.4 41.2 4.31 4.33 4.62 42.3 42.1 48.3 2.52 2.27 2.46 2.46 2.82 2.88 2.2 2.0 3.28 3.38 3.35 3.7 3.78 4.00 3.84 4.36 4.37 4.82 2.8 30.0 30.3 28.6 35.8 35.4 35.4 33.2 42.0 42.0 41.0 48.0 47.0 47.0 46.0 58.5 58.5 56.0 2.58 2.57 2.51 2.51 2.7 2.3 2.1 2.8 3.14 3.52 3.47 3.64 4.30 4.21 4.17 4.35 4.0 4.0 5.07 515.18-TG1C 35.2 33.7 35.7 36.1 33. 41.6 41.2 41.2 3.1 48. 48.8 46.8 53.5 52.1 55.6 51.4 66.4 66.4 66.2 2.78 2.64 2.70 2.68 2.0 3.07 3.07 3.04 3.17 3.5 3.64 3.84 4.52 4.3 4.46 4.60 5.11 5.10 5.16 Unitary Products Group 5

515.18-TG1C TYPICAL INSTALLATION - 018 thru 060 60" OVERHEAD CLEARANCE 18" SERVICE ACCESS CLEARANCE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10" CLEARANCE COIL AREA TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING 4 * H + ; H : 6 / - ) 1 4 1 / 6 * - 1 ) + + 4, ) + - 1 6 0 ) 6 1 ) - - + 6 4 1 + +, - ), 4 + ) +, - 5 6 0-4 5 6 ) 6 1, 4 7 16 K F A HJA H E = I - = @ J D A = J B EH I J I J = C A @ K H E C - A H C A? O 0 A = J 6 A H E = J K I A @ = J D A H I J = J I + 1 4 + 7 1 6 / 4, 7 / 7 6, 4 7 1 6! " 8 6 ) / - 6-4 1 ) * +, -. 4 5 6 1 ) 14 0 ), - 4 16 0 - - + 6 4 1+ 0 - ) 6 + 6 4 % 1 4-5 4 -, 4 4 / 4, 5 + 4 - + * + + 6 ) + 6 4 ; - ; ; 4 / 6 6 * 4 2 4 2 :. 1 -, 1 5 6 ) -, 7 2-4 / * 0 6 2-4 1 4 1 / &! $! # * 4 - ) - 4 2-4 1 4 1 /! " 8 + 6 4 14 + 1 D A /? J D A M L J = C A J A H E = >? J D A E @ H K EJ BJD B AHJA J D H A = E? = J K I= = H H = C A A J - + + ) 5 5 " + A? J F M A H M EH E C J J A H E = >?! 6 * K EJ I M EJ D K J A A? J H E? D A = J H? EH? K E, - 0 7 1, 1. 1 + ) 6 1 + 6 4 + - + 6 1 0 K E@ EI J = J K F A H K I J > A H A L A @ 6 Unitary Products Group

515.18-TG1C ACCESSORIES Refer to Price Manual for specific model numbers. Compressor Blanket - Designed to further reduce the normal operating sound and is required to meet Canadian sound levels for units of three tons and below. Blower Time Delay - 2FD06700224 allows blower to run 60 seconds after the cooling thermostat has been satisfied. Hard Start Kit (Single Phase Units) - Provides required starting torque for use with themal expansion valve. Low Temperature Lockout - 2LT06700224 - Prevents heat pump operation below minus 10 F ambient temperature. Outdoor Thermostat - 2TD06700124 - Consists of an adjustable outdoor thermostat and relay ina vented enclosure. It provides additional second stage control of the supplemental resistance heat.(balance Point Control) Room Thermostats - One of the following thermostats may be used with these heat pump systems. 6TH11702224 - Two stage heat / one stage cool / manual changeover, non electronic with sub-base. 6ET11704324 - Two stage heat / one stage cool / manual changeover, auxillary heat indicator, electronic non programmable. Unitary Products Group 7

MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application GXUA UPFLOW GXNA UPFLOW GYFD MULTI-POSITION (Upflow, Horizontal, Downflow) GXNF OUTDOOR FURNACE GXHD HORIZONTAL Air Handlers - For Non-Furnace Application UPFLOW DOWNFLOW HORIZONTAL NXVS or NXAH BLOWER FYRP or FYFP FAN COIL GYFD COIL UPFLOW HORIZONTAL 515.18 -TG1C (600) Unitary Products Group 5005 York Drive Norman, OK 7306 Supersedes: 515.18-TG1C (2)