Snapshot. SkyScan 4000 USER MANUAL

Similar documents
Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED Pinspot 2. Snapshot. User Manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

LED Pinspot 2. Snapshot. User Manual

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

CH-158 Color Bank 8 USER MANUAL

Snapshot. User Manual BOB LED

Snapshot. Hurricane 1300 USER MANUAL F-1300

1. Before You Begin What Is Included... 3 Unpacking Instructions Claims Product at a Glance... 3 Safety Instructions...

TABLE OF CONTENTS 1. BEFORE YOU BEGIN...

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Bubble King. User Manual

Bubble Machine. User Manual

USER MANUAL PAR56 LED PAR CANS

LED Twister II. User manual UK Version 1.0

USER MANUAL LUX-LD30W LED MOVING HEAD

User Guide for Logo Projector

FL-2R MOVING HEAD 120W

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

HyperFlex 12G.

1. Before you Begin Introduction Setup Operation Technical Information Returns...12

P/N Wheeler. user manual

Mania EF1 user manual

MOVING HEAD. User manual CAUTION!

Navigator ORDERCODE 40410

Compact LED profile with zoom

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

FiberSource Q150. user manual P/N

OBY-5. User manual MOVING HEAD CAUTION!

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Mini Aquatic ORDERCODE 30844

Spotlight 1,000,000 Power Series Cordless Rechargeable

QTFX-F1, QTFX-F2 FLAME EFFECT

Mania DC3 user manual

Measurements are expressed in millimeters.

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

ENGLISH Bumper Waves

OPERATION INSTRUCTIONS

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

USER MANUAL GOBO PROJECTOR Revolver KEEP THIS MANUAL FOR FUTURE NEEDS

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL

Ego 01 Ego 02 Ego 03 Logo Projector user manual

PRO Dimmer INSTRUCTION MANUAL

USER S MANUAL & WARRANTY INFORMATION

SpaceTracer 2000 CMY ORDERCODE 40961

Riverside. Placid Cove Entertainment PIER Assembly Instructions. Pier Left & Right Item # THANK YOU FOR YOUR PURCHASE.

American DJ. User Instructions. American DJ. Los Angeles, CA Charter Street

Maintenance Adjustments

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

TWIN HALOGEN SHOP LIGHT

Pure Spot 120LED USER MANUAL.

FX Shot ORDERCODE 60908

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

American DJ. User Instructions. American DJ

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

Light Source User Guide

82V LITHIUM-ION BATTERY CHARGER GC 400

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

STATIC DAYLIGHT PAR 575 VF

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

1200W INVERTER GENERATOR

4000 SYSTEM OPERATING MANUAL

Neutron Pro Operations Manual

Light Source User Guide

SPOTLIGHT 30 MILLION CANDLEPOWER

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

LED Downlight Ceiling Fixtures

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

MINISCAN ENGLISH INSTRUCTION MANUAL POWER SUPPLY AND INTERFACE INSTALLING THE PROJECTOR. 1.0 m HTI 300 ENGLISH

BL7000 SYSTEM OPERATING MANUAL

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Magnetic Torpedo Laser Level with Base Model No Instruction Manual

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

1 2 3a 3b THREADING CARD 9 10 ABC Office

OWNER'S MANUAL RED LINE EZ50

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Instructions for Installing the Vi p e r Si g n a l Ma s t e r with Brake Module

CONTENT 1 PICTURE GENERAL... 3

FL 150 XT-2 B, F, and C

Section 10: Engraving Machine Cleaning

Cordless two speed drill/driver K 10613

LITHIUM ION BATTERY CHARGER

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Mini Convex HID Fog Lights

BULLDOG OPERATION & SAFETY MANUAL P/N EU /1/10

Installation Instruction ALG Series LED Area Light Version: 3.1

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

shadow focus floodlight SFS-300 INSTRUCTIONS

Transcription:

SkyScan 4000 Snapshot OK on Dimmer For Use in Dry Outdoor Location For Use in Wet Outdoor Location Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse Duty Cycle USER MANUAL 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com

TABLE OF CONTENTS 1. Before You Begin... 3 What is included... 3 Unpacking Instructions... 3 AC Power... 3 Safety Instructions... 4 2. Introduction... 5 Features... 5 Product Overview... 5 3. Setup... 6 Lamp... 6 Lamp Installation... 6 Fuse Replacement... 8 Mounting... 8 Orientation... 8 Rigging... 8 4. Operating Instructions... 9 Operation... 9 To turn the power to the lamp on... 9 To activate the Pan rotation... 9 Contact Us... 12 5. Appendix... 13 General Maintenance... 13 Returns Procedure... 13 Claims... 13 Technical Specifications... 14 SkyScan 4000 User Manual 2 12/3/2008 4:27 PM

1. BEFORE YOU BEGIN What is included 1 x SkyScan 4000 1 x Power connector (no cable) 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. AC Power 230V ONLY! To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart. A fixture s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture s requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use. Wiring diagram The fixture includes an IP-44 wire terminator. This is designed to use the wire configuration shown below. Note: this unit does not ship with a wire terminator installed or in the package. You will need to supply your own power cable and terminator when installing/setting up this fixture. This should only be done by a qualified technician! You must use the proper cable when connecting this fixture. Use the minimum recommended cable of 10AWG-3 conductor insulated wiring. This will allow for proper grounding connection. Connector Wire Diagram SkyScan 4000 User Manual 3 12/3/2008 4:27 PM

Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product. Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. This product is intended for dry locations only! To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating. The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source. Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles. Maximum ambient temperature (Ta) is 104 F (40 C). Do not operate fixture at temperatures higher than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Never connect the device to a dimmer pack. Make sure the power cord is never crimped or damaged. Never disconnect the power cord by pulling or tugging on the cord. Avoid direct eye exposure to the light source while it is on. Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. SkyScan 4000 User Manual 4 12/3/2008 4:27 PM

2. INTRODUCTION Features Professional 4000W search light Motorized pan: 120 / manual tilt: 40 Quad power switches control lamp s intensity (1k, 2k, 3k, or 4k) Silent, hot-restrike ignition Variable mechanical zoom Ingress Protection: IP33 Product Overview Front lens Tilt Adjustment knob Fan intake vents Carrying handle Access panel Power input connector Transport, locking wheels SkyScan 4000 User Manual 5 12/3/2008 4:27 PM

3. SETUP Lamp The lamp for this fixture arrives installed at the factory. Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with alcohol and wipe it with a lint free cloth before installation. Warning! When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool! Always disconnect from main power prior to lamp replacement. Lamp Installation Note: the lamp is installed from the back (rear) of the fixture. 1) Be sure to remove power to the fixture before replacing the lamp. 2) Using a Phillips #2 screwdriver, remove the back cover of the fixture. Be careful of the wires for the fan, as this is attached to the back cover and is easy to damage when removing the panel. 3) Then, remove the front cover with a Phillips #2 screwdriver. Although the lamp is installed through the back of the fixture, you will need to gain access to the front of the fixture to detach the front end of the lamp. This is done with a crescent wrench. 4) Remove the lamp by loosening and detaching both ends of the lamp. Then, pull the old lamp out through the back of the fixture. 5) Then, install the new lamp the same way the old lamp was removed, but in reverse. 6) Close the front & rear cover before connecting power to the fixture. Note: be careful not to touch the envelope of the lamp! Always use an alcohol wipe to clean the lamp after installation to remove any residue and oil from the envelope! Back end of lamp Front end of lamp This is the nut to remove the lamp This is the nut to remove the lamp SkyScan 4000 User Manual 6 12/3/2008 4:27 PM

WARNING! Note: please be sure to adhere to the following instructions and cautions before installing/servicing this lamp. Mechanical installation Because of their high luminance, UV radiation and internal pressure in both the hot and cold state, Xenon lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Always use the safety covers supplied when handling Xenon lamps. When handling the lamps without their safety boxes, always wear safety goggles, a face mask and gauntlets with wrist protectors. Lamps with standard or Suprasil quartz emit intense UV radiation and produce ozone in the surrounding air. Certain precautions must therefore be observed when handling these lamps: All Xenon lamps are supplied in a safety cover. This protects users from possible spontaneous or induced bursting of the lamp. You should handle lamps only with safety cover. Store this safety cover for use during the removal of the lamp at the end of its service life. You should wear leather gloves covering the arteries and veins of your wrists and protective goggles or complete face protection covering the arteries and veins of your neck, such as a transparent plastic mask. Lamp Storage Lamps may only be stored if suspended freely from their bases inside their safety covers. Leaving them to roll around unprotected on a desk or shelf can result in micro cracks in the surface of the quartz glass, and burst lamps later on. If the lamp is inadvertently operated inside its safety cover, the sleeve will melt within a few seconds and the lamp will be unusable. When removing lamps, the reverse procedure must be followed: first put the safety cover or some protection around the lamp, then remove the lamp. Electrical connection Care must be taken to ensure that the lamp is connected with correct polarity; the positive pole of the rectifier must be connected to the base marked +, the negative pole to the base marked -. Incorrect polarity results in total lamp failure within a few seconds. Cleaning the lamps Xenon lamps may only be held by the base. If the quartz bulb or the shafts should ever be inadvertently touched with bare fingers (which should never happen, because unprotected lamps should only be handled with leather gloves), the fingerprints must be removed immediately. A lint-free cloth moistened with spirit is best for this, after which the lamp should be rubbed dry, taking care not to scratch the quartz glass surface. Damage to the quartz may cause the lamp to break during later operation. If fingerprints are not removed they burn into the quartz glass surface where they act as a seed for ever-expanding recrystallization of the quartz. This causes the quartz to lose its strength and increases the risk of bursting. SkyScan 4000 User Manual 7 12/3/2008 4:27 PM

Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a Phillips #2 screwdriver, unscrew the fuse holder from its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its place and reconnect power. Note: there are 4 fuses in this fixture, each located by the corresponding lamp power switches The fuse is located inside this compartment. Remove using a Phillips #2 screwdriver. FUSE Mounting ORIENTATION This fixture may only be mounted in a standing, vertical position, provided there is adequate room for ventilation and movement. Note: this fixture MUST be positioned in an upright position to allow proper cooling, ventilation, and IP rating! RIGGING It is important never to obstruct the fan or vents pathway. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs. When selecting installation location, take into consideration lamp replacement access and routine maintenance. For use in dry locations only! SkyScan 4000 User Manual 8 12/3/2008 4:27 PM

4. OPERATING INSTRUCTIONS Operation Pan motor switch Power Indicator Fuse (X4) 15A 250V Lamp power switch (X4) TO TURN THE POWER TO THE LAMP ON 1) Using the 4 lamp power switches, select one at a time, in combination, until you reach the desired light output. 2) Please wait 30 seconds between activating each additional lamp switch. TO ACTIVATE THE PAN ROTATION 1) Locate the pan motor switch. 2) Switch it to the ON position to enable bi-directional rotation. 3) To disable bi-directional rotation, switch this to the OFF position. Note: the pan cannot be manually adjusted. SkyScan 4000 User Manual 9 12/3/2008 4:27 PM

TO ADJUST THE ZOOM OF THE FIXTURE 1) Locate the ZOOM adjustment of the fixture, highlighted in the diagram below. 2) Turn the adjustment knob clockwise to increase the beam angle. 3) Turn the adjustment knob counter-clockwise to decrease the beam angle. Zoom adjustment knob SkyScan 4000 User Manual 10 12/3/2008 4:27 PM

General Troubleshooting Applies to Symptom Solution(s) Lights Foggers & Snow Controllers Dimmers & Chaser Auto shut off Check fan thermal switch reset Beam is very dim or not bright Breaker/Fuse keeps blowing Clean optical system or replace lamp Check total load placed on device Chase is too slow Check users manual for speed adjustment Device has no power Check for power on Mains. Check device s fuse. (internal and/or external) Fixture is not Check DMX Dip switch settings for correct addressing responding Check DMX cables Check polarity switch settings Fixture is on but Make sure you have the correct audio mode on the there is no control switches. If audio provided via ¼ jack, make movement to the sure a live audio signal exists audio Adjust sound sensitivity knob Lamps cuts off Possible bad lamp or fixture is overheating. sporadically Lamp may be at end of its life. Light will not come Some discharge lamps require a cooling off period on after power failure before the electronics in the fixture can kick start it again, wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note: Keep DMX cables separated from power cables or black lights. Moves slow Check 220/110v switch for proper setting No flash Re-install bulb, may have shifted in shipping No laser output No light output Relay will not work Remote does not work Stand alone mode Bounce mirror motor may have shifted during shipping, readjust Check slip ring & brushes for contact Install bulb Call service technician Check reset switch Check cable connections Make sure connector is firmly connected to device All Chauvet lighting fixtures featuring stand-alone functions do not require additional settings, simply power the fixture and it will automatically enter into this mode If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location on the next page. SkyScan 4000 User Manual 11 12/3/2008 4:27 PM

Contact Us World Wide General Information CHAUVET 3000 North 29 th Court Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084 Technical Support World Wide Web CHAUVET 3000 North 29 th Court Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service) www.chauvetlighting.com SkyScan 4000 User Manual 12 12/3/2008 4:27 PM

5. APPENDIX General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint. Returns Procedure The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. Note: If you are given an RMA #, please include the following information on a piece of paper inside the box: 1) Your name 2) Your address 3) Your phone number 4) The RMA # 5) A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise. SkyScan 4000 User Manual 13 12/3/2008 4:27 PM

Technical Specifications WEIGHT & DIMENSIONS Length... 27 in (686 mm) Width... 27 in (686 mm) Height... 43.5 in (1,105 mm) Weight... 174 lbs (79 kg) POWER AC Power... 230V 50Hz Fuse... 15A 250V (4X) Power Consumption & current (1K)... 853W (5.3A) max 0.83 PF at 230V Power Consumption & current (2K)... 1481W (13.7A) max 0.63 PF at 230V Power Consumption & current (3K)... 2.300W (21.6A) max 0.68 PF at 230V Power Consumption & current (4K)... 3,200W (26.4A) max 0.73 PF at 230V Inrush Power... (1.2A ~ 26.4A) at 230V LIGHT SOURCE Lamp... XQ4000 4000W 6000 K 500hrs PHOTO OPTIC Luminance @ 27m... (490,000 lux) Beam Angle... 1 ~15 RANGE Pan (motorized)... 120 Tilt (manual)... 40 THERMAL Maximum ambient temperature... 104 F (40 C) ORDERING INFORMATION SkyScan 4000... SKYSCAN4000 WARRANTY INFORMATION Warranty... 1-year limited warranty SkyScan 4000 User Manual 14 12/3/2008 4:27 PM