ahead of time Voltage Stabilisers

Similar documents
ahead of time Voltage Stabilisers

ahead of time Voltage Stabilisers

ORION PLUS three-phase kVA

ahead of time Voltage Stabilisers

CT-GB-39/05 VOLTAGE STABILISERS 1

PRODUCT CATALOGUE 2016

TECHNICAL DATA SHEET KVA UPS Systemss

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SAVER DSP SERIES. 3-10kVA USER MANUAL

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

ITW GSE 2400 COMPACT GPU kva solid-state GPU

Technical Specification SENTINEL PRO

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

HOBART POWERMASTER & 90 kva solid-state GPU. It s all about connections

HOBART POWERMASTER & 90 kva solid-state GPU. It s all about connections

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Technical Data Sheets

Technical Data Sheets

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

MASTERYS IP+ 10 to 80 kva

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

60 to 160 kva.

MGE TM Galaxy TM 7000

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Power Quality and Energy Management

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Industrial PFC UPS System

Three Phase UPS Systems Range: 10 to 500kVA

POWER kva

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

DC POWER SUPPLY SYSTEMS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

PQstorI One stop solution for energy storage and power quality

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

MGE TM Galaxy TM 7000 GFC

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Petrochemical processing Ship Yards Oil Fields Irrigation

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Sola/Hevi-Duty S3K Series Mini-Tower UPS

LV Capacitor Bank APC

MKN-DSP SERIES - THREE PHASE

Variable speed application guidelines

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Green Power 2.0 MASTERYS GP

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

UPS Multi Sentry 10-20kVA

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Illuminator Series CR NEMA 3R

PCS AC POWER LINE CONDITIONERS. PCS H SERIES - THREE PHASE - 6 to 500 kva H - THREE PHASE SERVO ELECTRONIC DESIGN. AC - THREE PHASE - 6 TO 500 kva

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Power Conversion System The Best Technology for your photovoltaic and storage system

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Marketing Management Team of Europe

SESL H - THREE PHASE AC VOLTAGE STABILISERS & REGULATORS. SESL H SERIES - THREE PHASE to 1500 kva. AC THREE PHASE TO 1500 kva

DYNACOMP. The top-class reactive power compensator

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Master Plus kva

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Appendix: Safety and application notes for... 15

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TLE Series UPS 400/500 kw With eboost Technology

Master MPS kva kva 3:1 3:3 VFI TYPE

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

ABB central inverters PVS to 2091 kva

Power Protection Discrete Automation & Motion South Africa

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Transcription:

ahead of time Voltage Stabilisers

ahead of time Founded in 1969, ORTEA SpA is a leading company in manufacturing and engineering stabilisers and magnetic components. Over forty years in the business and ongoing technical research have made of ORTEA a competitive and technologically advanced company. Close co-operation between design, production and marketing enables to meet the requirements of a constantly growing number of customers. In 1996 ORTEA joined ICAR Group, made of Italian and European industrial units specialised in manufacturing capacitors and power factor correction systems. Beside standard production, ORTEA can be extremely flexible in developing and manufacturing special equipment according to User s specification. All this thanks to the experience gained over many years of applied technological development. Such development includes IT tools that enable the technical staff to elaborate electrical and mechanical designs for each «custom product» on a quick and cost-effective basis. ORTEA is well established in the global market. Thanks to strategically positioned offices and distributors and efficient commercial relations, ORTEA s products are installed and working in a large number of countries. ORTEA headquarters (Italy) ORTEA branches (Russia, Ivory Coast, Venezuela) www.ortea.com

Index Digital stabilisers Pg. Forward 4 The solution 5 Electro-mechanical digital stabilisers Pg. Design criteria 6 Main components 7 Criteria for choosing the right type 8 Product range 10 Main characteristics 11 Vega Single-phase 0.3-25kVA Antares Single-phase 15-135kVA 16 Orion Three-phase 2-250kVA 20 Orion Plus Three-phase 30-50kVA 26 Sirius Three-phase 60-6000kVA 32 Sirius Advance Three-phase 60-0kVA 40 Accessories 45 Cabinets 54 Static digital stabilisers Pg. Product range 55 Gemini Single-phase 4-20kVA 56 Aquarius Three-phase 10-60kVA 58 «Special» stabilisers Pg. Product range 61 DLC series Line conditioners 63 OPTInet series Line optimisers 64 BTS series Telecommunication (TLC) 68 BC series Broadcasting 70 AOT series Mains filters 71 OUTDOOR series Outdoor installations 72 F&B series Food & Beverage, packaging and bottling industry 73 3

Forward Many electrical devices are designed to work with a sinusoidal AC at a certain nominal value (for example, V) and frequency (for example, 50Hz). In reality, very often the devices have to face more problematic conditions such as: Not sinusoidal supply due to harmonics in the mains caused by non-linear loads (inverters, drives, welders, discharge lamps, etc.). Supply fluctuating in relation to the nominal value. Said variations can be «fast» and waste themselves away in a few milliseconds (for example, distribution lines hit by lightning) or «slow», with duration that can last several seconds, minutes or even hours depending on the cause. Slow fluctuations can increase the level («surges» generated, for example, by poor MV regulation at distribution, disconnection of large loads, over at generators output) or more frequently decrease the nominal («sags» generated, for example, by connection of large loads, motor startup, undersized distribution lines, faults to ground, poor MV regulation). Although specific means for each of the issues listed above are available, the stabiliser is the solution with the best cost/benefit ratio. The availability of high quality supply independently from input fluctuation is very often a key feature to ensure efficiency and reliability for the User. Reduced productivity, data loss, security failure, machine faults, inaccurate information and domestic inconveniences are only a few examples of potential problems caused by unsteady supply. Obviously, all that results in higher managing costs. 4

The solution The stabiliser has proven to be an effective solution able to prevent potentially dangerous situations created by input instability. A list of possible fields and applications where devices sensitive to variations can be used is given below: Public sector: Telecommunication/telephoning, hospitals, public offices, radar installations, military industry. Food & Beverage: Bottling, packaging, food processing industry, intensive breeding. Private sector: Banks, factories, laboratories, small businesses, fun parks and fairs. Industrial sector: Laser cutting, water shearing, electronic drives, tobacco industry, machinery in general. In all these applications, fluctuation, even though within the tolerance admitted by the Standards, can generate operating issues. In that case, devices particularly sensitive can show errors or malfunctions beyond the acceptable limit. Typical situations where can be subject to fluctuation beyond the admitted threshold even in standard equipment, are: Loads supplied by weak or undersized distributing lines. This happens in rural area or where the distributing line is long (breeding farms, tourist resorts, hotels). Private houses with high power installations (swimming pool pumps, big chillers, special lighting systems) and/or particularly sensitive (high power consumer electronics, etc.). Loads located near large industrial plants where individual high power devices (MV motors) can induce reduction at startup. Island operating loads (ships, offshore rigs, loads not connected to the mains). In all the above mentioned examples, the choice of a stabiliser instead of an Uninterruptible Power Supply (UPS) system is the optimum solution: Considerably lower cost at the same power. High output stability guaranteed even for input fluctuation not manageable by a UPS. Given the same performance, absence of introduced harmonic distortion. More robust and reliable construction, allowing for use in hard environments. Overload capability up to twice the rated current (max 2 mins). No concerns in terms of storage, transportation, maintenance and disposal due to the fact that batteries are not used. Smooth and reliable regulation of the load ensuring a ±0.5% accuracy even with important input variation. High efficiency. High inrush current withstand ability. 5

Electro-mechanical digital stabilisers Design criteria A stabiliser is a power device destined to be positioned between the mains and the User. The purpose is to ensure that the User is fed a subject to a variation much lower (±0.5% with regards to the nominal value) that the one guaranteed by the distributing system. The stabilization is performed on the «true rms» and it is not affected by harmonics in the mains. Due to the fact that the regulation does not involve any sine wave partialization (which is what happens in power electronic converters such as inverters and UPSs), neither an appreciable harmonic distortion nor a phase displacement is introduced on the downstream line. The stabiliser is not affected by the load power factor (cos φ) and can operate with a load percentage varying between 0% and 100% on each phase. Regulation speed depends on the input variation percentage and on the type of construction. Indicatively, said speed ranges between 8 and 30millisec/V. Basically, a stabiliser is made of a buck/boost transformer, a regulator and an electronic control. Based on a microprocessor that samples at high frequency the output, the control system drives the regulator gearmotor. By doing so, the regulator rollers change their position and therefore the drawn and supplied to the buck/boost transformer primary winding. Being the secondary of the buck/boost transformer in phase or in opposition to the supply, the drawn from the regulator is added or subtracted to the mains, thus compensating its variations. T h e v o l t a g e r e g u l a t o r i s n o t h i n g b u t a n autotransformer with continuously variable transformer ratio. Depending on the stabiliser power, the regulator can be either toroidal or columnar. The stabilisers are designed and built in compliance with the European Directives concerning CE marking 2006/95/EEC (Low Voltage Directive) and 2004/EEC (Electromagnetic Compatibility Directive). Standard units are housed in an IP21 metallic enclosure RAL7035 painted. Cooling is guaranteed by natural air circulation aided by extracting fans over a certain temperature. The stabiliser can operate with input and output different (380V/415V) from the rated (V). Such setting can be performed at the factory or at the Customer s premises according to the instructions given in the handbook. On SIRIUS stabilisers, the output reference and the main configuration parameters can be set directly on the unit by communicating with the microprocessor via a PC connection (through RS232 and USB interfaces) and/or remotely from a remote station (via Ethernet, GPRS modem or MODBUS TCP/IP protocol). Working principle of an electro-mechanical digital stabiliser U V W TB TB TB U1 V1 W1 VR VR VR INPUT OUTPUT N N M M M TB: Buck/boost Transformer VR: Voltage regulator DIGITAL CONTROL BOARD 6

Main components 1. Buck/boost transformer Standard dry-type transformer with the secondary winding connected in series to the mains and the primary winding supplied by the regulator. 2. Voltage regulator Basically, it is an autotransformer with continuously variable transformer ratio. The intake varies depending on the position of the contacts; therefore the supplied to the transformer primary winding also varies. Being the across the regulator contacts (and consequently that on the secondary winding of the buck/boost transformer) either in phase or in opposition to the supply, it is then added or subtracted to the supply, thus compensating its variations. 3. Auxiliary circuit with microprocessor The DSP (Digital Signal Processor) microprocessor-based control circuit (specifically designed for drives with totally digitalised signal) compares the output value to the reference one sampling it 2000 times per second. When an anomaly is detected, the control drives the regulator gearmotor. By doing so, the regulator rollers change their position thus varying the drawn and supplied to the buck/boost transformer primary winding. The input variation is therefore automatically compensated. The control system operates so that the output accuracy is ±0.5%. The microprocessor is fitted with the soft stop function enabling the regulation to work smoothly even in case of strong fluctuation. 3 2 2 2 1 7

Criteria for choosing the right type Number of phases Rated Input variation range Type of regulation Rated power The number of phases of a stabiliser depends on the type of load: Single-phase load: single-phase stabiliser. Combination of several single-phase loads on the same line: three-phase stabiliser or a single-phase stabiliser on each load. Three-phase load: three-phase stabiliser. Due to the fact that the nominal varies internationally, establish the rated required at the stabiliser input and output. In case of three-phase systems, provide with the line-to-line value. The standard stabiliser can operate with: frequency 50Hz: nominal 380V-V-415V frequency 60Hz: nominal 440V-460V-480V It's key information for the choice and the design of the stabiliser. Establish the amplitude of the oscillation of the input and always keep a safety margin on such percentage: if the measured fluctuation is ±16%, then choose a stabiliser suitable for ±20% variation. The standard production can include stabilisers for symmetrical and asymmetrical input variation range. If the input variation goes beyond the rated range, the difference between real and rated variation is transferred onto the output. The three-phase stabilisers perform an independent regulation on each phase. The connection to the distributing line neutral wire is mandatory. Should the neutral wire not be available, a specific accessory component must be added. For special applications, three-phase stabilisers regulating the average value of the three output s are also available on request. All the stabilisers are designed for the maximum input current, but it is advisable to consider an extra safety margin for possible future expansions. In a stabiliser, the power is expressed in kva, whilst the load power is usually expressed in kw. Remember that the link between these two measuring units is provided by the power factor (cos φ): kva = kw / cos φ Also, remember that: If the power factor and/or the load power in kw cannot be easily established, measure the absorbed currents in order to allow for a correct design of the stabiliser keeping in mind that. kva (1-ph.) = load x load current kva (3-ph.) = Ö3 phase to phase load x load current 8

Installation Choose the other characteristics of the stabiliser considering the installation conditions. The following aspect must be known: IP protection degree required Indoor or outdoor installation Site altitude and climatic characteristics Ambient temperature Possible environmental hazards such as aggressive atmosphere, exposure to chemical components and so on. Accessories Special construction The stabilisers can be fitted with: Interruption and protection devices. Over/under output protection. Manual bypass line. Input isolating transformer. Total protection kit. Surge arrestor (SPD) Integrated automatic power factor correction system. EMI/RFI filter. Neutral point reactor. Up to IP55 protection degree for both indoor and outdoor installation By means of some modifications, it is possible to obtain special stabilisers able to: deal with asymmetrical input variation (for example, from -25% to +10% of the nominal ). deliver an output different from the input one (for example, Vin = V ±15%, Vout = 460V ±0.5%). 9

Product range Vega Single-phase 0.3-25kVA Antares Single-phase 15-135kVA Orion Three-phase 2-250kVA Orion plus Three-phase 30-50kVA Sirius Three-phase 60-6000kVA Sirius advance Three-phase 60-0kVA 10

Main characteristics Single-phase Three-phase Vega Antares Orion Orion plus Sirius Sirius advance Output accuracy ±0,5% ü ü ü ü ü ü Regulator rolling contacts ü ü ü ü ü ü Toroidal regulator ü up to 80kVA ü up to 250kVA x x Columnar regulator x from 100kVA x from 320kVA ü ü Control electronic board ü ü ü ü ü ü Remote communication board x x x x ü ü Local display ü x x x ü ü Alarm signal Display LED LED x x x External alarm LEDs x x x ü ü ü External phase indication LEDs x x x ü ü ü Acoustic alarm ü ü ü ü ü ü USB connection x x x x ü ü RS232 connection x from 100kVA ü x x GPRS modem connection x x x x ü ü Ethernet connection x x x x ü ü MODBUS TCP/IP protocol x x x x ü ü Maintenance required signal x x x x ü ü Regulator protection (magneto-thermal) ü ü ü up to 250kVA x x Regulator protection (electronic) x x x from 320kVA ü ü Varistor protection ü ü up to 45kVA x x x Class I surge arrestor (SPD) ü ü Class II surge arrestor (SPD) from 60kVA ü ü ü Industrial modular enclosure x x x ü ü ü Handling wheels from 20kVA up to 35kVA up to 45kVA x x x Digital voltmeter ü x x x x x Multimetre / Line analyser x ü ü ü ü ü Assisted ventilation x ü from 60kVA ü ü ü Air conditioning ventilation x Load variation up to 100% ü ü ü ü ü ü Overload up to 200% for 2 mins ü ü ü ü ü ü Harmonic distortion none introduced none introduced none introduced none introduced none introduced none introduced IP21 degree protection ü ü ü ü ü ü Protection degree other than IP21 Indoor installation ü ü ü ü ü ü Outdoor installation Ambient temperature -25/+45 C -25/+45 C -25/+45 C -25/+45 C -25/+45 C -25/+45 C Storage temperature -25/+60 C -25/+60 C -25/+60 C -25/+60 C -25/+60 C -25/+60 C Max relative humidity 95% 95% 95% 95% 95% 95% ü standard x not available optional 11

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Vega single-phase 0.3-25kVA Standard features Selectable output 220-230-240V Frequency 50/60Hz ±5% Admitted load variation Up to 100% Cooling Natural ventilation Ambient temperature -25/+45 C Storage temperature -25/+60 C Max relative humidity 95% Admitted overload 200% 2 min. Harmonic distortion None introduced Colour RAL 7035 Protection degree IP21 Instrumentation Output digital voltmeter Installation Indoor A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value.

Vega single-phase 0.3-25kVA VEGA stabilisers can be chosen to match different ranges of input fluctuation. Standard models offer a double input connection so that with the same unit two different input variations (±15/±20% or ±25/±30%) can be dealt with. An automatic circuit breaker is mounted on the regulation circuit to protect against overload and short circuit on the regulator. The auxiliary circuit is protected by fuses. A digital display providing with output and alarm readings is fitted on the front panel. By means of a changeover contact, the stabiliser control card allows for the visual and acoustic signalling of the following alarms: Min/max output. Internal overheating. Overload on the regulator. The control logic is based on a digital microprocessor. All the VEGA stabilisers are fitted with the same control card, thus simplifying maintenance operations and spare parts storage. Rating in relation to the input variation percentage ±15% ±20% ±25% ±30% +15%/-25% +15%/-35% +15%/-45% 1 0.7 0.5 0.3 0.7 0.5 0.3 2.5 2 1.5 1 2 1.5 1 5 4 3 2 4 3 2 7 5 4 3 5 4 3 10 7 5 4 7 5 4 15 10 7 5 10 7 5 20 15 10 7 15 10 7 25 20 15 10 20 15 10 13

Vega single-phase 0.3-25kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±20%/±15% 0.7-20 ±20 0.7 184-276 3.8 3 230 >96 1-15 ±15 1 195-265 5 4.3 16 2-20 ±20 2 184-276 11 8.7 230 >96 2.5-15 ±15 2.5 195-265 13 11 16 4-20 ±20 4 184-276 21 17 230 >96 5-15 ±15 5 195-265 26 22 16 5-20 ±20 5 184-276 28 230 22 7-15 ±15 7 195-265 35 30 16 7-20 ±20 7 184-276 38 30 230 10-15 ±15 10 195-265 51 43 16 10-20 ±20 10 184-276 54 43 230 15-15 ±15 15 195-265 76 65 16 15-20 ±20 15 184-276 81 65 230 20-15 ±15 20 195-265 102 87 16 20-20 ±20 20 184-276 109 87 230 25-15 ±15 25 195-265 8 109 16 Input variation range ±30%/±25% 0.3-30 ±30 0.3 161-300 1.9 1.3 8 230 >96 0.5-25 ±25 0.5 172-288 2.9 2.2 10 1-30 ±30 1 161-300 6.2 4.3 8 230 >96 1.5-25 ±25 1.5 172-288 8.7 6.5 10 2-30 ±30 2 161-300 8.7 8 230 >96 3-25 ±25 3 172-288 17 13 10 3-30 ±30 3 161-300 19 13 8 230 4-25 ±25 4 172-288 23 17 10 4-30 ±30 4 161-300 25 17 8 230 5-25 ±25 5 172-288 29 22 10 5-30 ±30 5 161-300 31 22 8 230 7-25 ±25 7 172-288 40 30 10 7-30 ±30 7 161-300 44 30 8 230 10-25 ±25 10 172-288 57 43 10 10-30 ±30 10 161-300 62 43 8 230 15-25 ±25 15 172-288 87 65 10 16 24 28 13 41 13 47 13 55 14 92 22 115 16 24 28 13 41 13 47 13 56 14 92 22 115 14

Vega single-phase monofase 0.3-25kVA Type Tipo Input Range variazione variation tensione range ingresso Rating Potenza Input Range tensione range ingresso Maximum Corrente input ingresso current massima Output Tensione uscita ±0.5% Output Corrente current uscita Efficiency Rendimento h Speed Velocità regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type Tipo [kg] Enclosure Custodia Weight Peso Input Range variazione variation tensione range ingresso +15%/-25% +15%/-25% 0.7-15/25 +15/-25 0.7 172-265 4 230 3 >96 17 2-15/25 +15/-25 2 172-265 230 8.7 >96 25 4-15/25 +15/-25 4 172-265 23 230 17 >96 29 5-15/25 +15/-25 5 172-265 29 230 22 13 42 7-15/25 +15/-25 7 172-265 40 230 30 13 48 10-15/25 +15/-25 10 172-265 57 230 43 13 56 15-15/25 +15/-25 15 172-265 87 230 65 14 92 20-15/25 +15/-25 20 172-265 116 230 87 22 115 Input Range variazione variation tensione range ingresso +15%/-35% +15%/-35% 0.5-15/35 +15/-35 0.5 150-265 3.4 230 2.2 >96 10 17 1.5-15/35 +15/-35 1.5 150-265 10 230 6.5 >96 10 25 3-15/35 +15/-35 3 150-265 20 230 13 >96 10 29 4-15/35 +15/-35 4 150-265 26 230 17 10 13 42 5-15/35 +15/-35 5 150-265 34 230 22 10 13 48 7-15/35 +15/-35 7 150-265 46 230 30 10 13 56 10-15/35 +15/-35 10 150-265 66 230 43 10 14 92 15-15/35 +15/-35 15 150-265 100 230 65 10 22 115 Input Range variazione variation tensione range ingresso +15%/-45% +15%/-45% 0.3-15/45 +15/-45 0.3 6-265 2.4 230 1.3 >96 8 17 1-15/45 +15/-45 1 6-265 7.8 230 4.3 >96 8 25 2-15/45 +15/-45 2 6-265 16 230 8.7 >96 8 29 3-15/45 +15/-45 3 6-265 24 230 13 8 13 42 4-15/45 +15/-45 4 6-265 31 230 17 8 13 48 5-15/45 +15/-45 5 6-265 40 230 22 8 13 56 7-15/45 +15/-45 7 6-265 55 230 30 8 14 92 10-15/45 +15/-45 10 6-265 78 230 43 8 22 115 15

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Antares single-phase 15-135kVA Standard features Selectable output 220-230-240V Frequency 50/60Hz ±5% Admitted load variation Up to 100% Cooling Natural air ventilation (aided with fans) Ambient temperature -25/+45 C Storage temperature -25/+60 C Max relative humidity 95% Admitted overload 200% 2 min. Harmonic distortion None introduced Colour RAL 7035 Protection degree IP21 Instrumentation Output digital multimetre Installation Indoor Over protection Class II output surge arrestor A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 16

Antares single-phase 15-135kVA ANTARES stabilisers can be chosen to match different ranges of input fluctuation. Standard models offer a double input connection so that with the same unit two different input variations (±15%/±20% or ±25%/±30%) can be dealt with. An automatic circuit breaker is provided on the regulation circuit to protect against overload and short circuit on the regulator. The auxiliary circuit is protected by fuses. The digital measuring instrumentation is installed on the cabinet door and consists of a digital multimetre. The alarms are displayed on the control card. By means of a changeover contact, the stabiliser control card allows for the acoustic signalling of the following alarms: min/maximum output. internal overheating. overload on the regulator. The control logic is based on a digital microprocessor. All the ANTARES stabilisers are fitted with the same control card, thus simplifying maintenance operations and spare parts storage. Rating in relation to the input variation percentage ±15% ±20% ±25% ±30% +15%/-25% +15%/-35% +15%/-45% 35 25 20 15 25 20 15 45 35 25 20 35 25 20 60 45 35 25 45 35 25 80 60 45 35 60 45 35 100 80 60 45 80 60 45 135 100 80 60 100 80 60 17

Antares single-phase 15-135kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±20%/±15% 25-20 ±20 25 184-276 136 109 230 35-15 ±15 35 195-265 179 152 16 35-20 ±20 35 184-276 190 152 230 45-15 ±15 45 195-265 230 196 16 45-20 ±20 45 184-276 245 196 230 60-15 ±15 60 195-265 307 261 16 60-20 ±20 60 184-276 326 261 230 80-15 ±15 80 195-265 409 348 16 80-20 ±20 80 184-276 435 348 230 100-15 ±15 100 195-265 511 435 16 100-20 ±20 100 184-276 544 435 230 135-15 ±15 135 195-265 690 587 16 Potenza Range tensione ingresso Corrente ingresso massima Tensione uscita ±0.5% Corrente uscita Rendimento h Velocità Custodia 23 180 30 200 Peso 40 320 40 390 41 550 41 650 Input variation range ±30%/±25% 15-30 ±30 15 161-300 93 65 8 230 20-25 ±25 20 172-288 116 87 10 20-30 ±30 20 161-300 4 87 8 230 25-25 ±25 25 172-288 145 109 10 25-30 ±30 25 161-300 156 109 8 230 35-25 ±25 35 172-288 203 152 10 35-30 ±30 35 161-300 217 152 8 230 45-25 ±25 45 172-288 261 196 10 45-30 ±30 45 161-300 279 196 8 230 60-25 ±25 60 172-288 348 261 10 60-30 ±30 60 161-300 373 261 8 230 80-25 ±25 80 172-288 464 348 10 23 180 30 200 40 320 40 390 41 550 41 650 18

Antares single-phase 15-135kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range +15%/-25% 25-15/25 +15/-25 25 172-265 145 230 109 14 23 190 35-15/25 +15/-25 35 172-265 203 230 152 14 30 210 45-15/25 +15/-25 45 172-265 261 230 196 14 40 330 60-15/25 +15/-25 60 172-265 348 230 261 14 40 80-15/25 +15/-25 80 172-265 464 230 348 14 41 560 100-15/25 +15/-25 100 172-265 580 230 435 14 41 660 Input variation range +15%/-35% 20-15/35 +15/-35 20 150-265 134 230 87 11 23 200 25-15/35 +15/-35 25 150-265 167 230 109 11 30 220 35-15/35 +15/-35 35 150-265 234 230 152 11 40 340 45-15/35 +15/-35 45 150-265 301 230 196 11 40 410 60-15/35 +15/-35 60 150-265 401 230 261 11 41 570 80-15/35 +15/-35 80 150-265 535 230 348 11 41 670 Input variation range +15%/-45% 15-15/45 +15/-45 15 6-265 118 230 65 9 23 210 20-15/45 +15/-45 20 6-265 158 230 87 9 30 230 25-15/45 +15/-45 25 6-265 198 230 109 9 40 350 35-15/45 +15/-45 35 6-265 276 230 152 9 40 420 45-15/45 +15/-45 45 6-265 356 230 196 9 41 580 60-15/45 +15/-45 60 6-265 474 230 261 9 41 680 Output current Efficiency h Speed regulation Enclosure Weight 19

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Orion three-phase 2-250kVA Standard features Voltage stabilisation Selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to 100% Admitted load imbalance 100% 220-230-240V (L-N) / 380--415V (L-L) Cooling Natural air ventilation up to 45kVA ±15% Aided with fans from 60kVA ±15% Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion -25/+45 C -25/+60 C 200% 2 min. None introduced Colour RAL 7035 Protection degree instrumentation Installation IP21 Output digital multimetre Indoor Over protection Class II output surge arrestor (from 60kVA ±15%) A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 20

Orion three-phase 2-250kVA ORION stabilisers can be chosen to match different ranges of input fluctuation. Standard models offer a double input connection so that with the same unit two different input variations (±15%/±20% or ±25%/±30%) can be dealt with. The output regulation is performed independently on each phase (stabilization of each phase-to-neutral ). ORION stabilisers are used with three-phase loads and single-phase loads with 100% current imbalance across the phases and asymmetrical mains. ORION stabilisers require the neutral wire presence. It can also operate without neutral wire by adding a device able to generate it (D/Yn isolating transformer or neutral point reactor). Every stabiliser belonging to this range is equipped with the same control board used on VEGA and ANTARES models, thus simplifying maintenance operations and spare parts storage. Up to 45kVA, the stabilisers are equipped with wheels for easy handling. An automatic circuit breaker is mounted on the regulation circuit to protect against overload and short circuit on the regulator. The auxiliary circuit is protected by fuses. The measuring instrumentation is installed on the cabinet door and consists of one multi-task digital line analyser. Such instrument is able to provide with information regarding the status of the line downstream the stabiliser, such as phase and linked s, current, power factor, active power, apparent power, reactive power, etc. By means of a changeover contact, the stabiliser control card allows for the acoustic signalling of the following alarms: minimum, maximum, internal overheating and overload on the regulator. Voltage control and stabilisation, performed on the true RMS value, are managed by the digital microprocessor. Rating in relation to the input variation percentage ±15% ±20% ±25% ±30% +15%/-25% +15%/-35% +15%/-45% 5 4 3 2 4 3 2 10 7 4 3 7 4 3 15 10 7 4 10 7 4 20 15 10 7 15 10 7 30 20 15 10 20 15 10 45 30 20 15 30 20 15 60 45 30 20 45 30 20 80 60 45 30 60 45 30 105 80 60 45 80 60 45 135 105 80 60 105 80 60 150 0 90 80 n.d. n.d. n.d. 175 135 105 90 n.d. n.d. n.d. 200 150 0 105 n.d. n.d. n.d. 250 175 135 0 n.d. n.d. n.d. 21

Orion three-phase 2-250kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±20%/±15% 4-20 ±20 4 320-480 7.3 5.8 >96 5-15 ±15 5 340-460 8.5 7.2 16 7-20 ±20 7 320-480 13 10 >96 10-15 ±15 10 340-460 16 14 16 10-20 ±20 10 320-480 17 14 >96 15-15 ±15 15 340-460 25 21 16 15-20 ±20 15 320-480 26 21 20-15 ±15 20 340-460 34 29 16 20-20 ±20 20 320-480 36 29 30-15 ±15 30 340-460 51 43 16 30-20 ±20 30 320-480 54 43 45-15 ±15 45 340-460 76 65 16 45-20 ±20 45 320-480 81 65 60-15 ±15 60 340-460 102 87 16 60-20 ±20 60 320-480 109 86 80-15 ±15 80 340-460 136 116 16 80-20 ±20 80 320-480 145 116 105-15 ±15 105 340-460 179 152 16 105-20 ±20 105 320-480 190 152 135-15 ±15 135 340-460 230 195 16 0-20 ±20 0 320-480 217 174 150-15 ±15 150 340-460 255 217 16 135-20 ±20 135 320-480 244 195 175-15 ±15 175 340-460 298 253 16 150-20 ±20 150 320-480 271 217 200-15 ±15 200 340-460 340 289 16 175-20 ±20 175 320-480 316 253 250-15 ±15 250 340-460 425 361 16 22 90 22 96 22 110 23 155 23 180 23 200 31 310 40 430 41 490 41 580 44 710 44 880 44 910 44 950 22

Orion three-phase 2-250kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±30%/±25% 2-30 ±30 2 280-520 4.1 2.9 8 >96 3-25 ±25 3 300-500 5.7 4.3 10 3-30 ±30 3 280-520 6.1 4.3 8 >96 4-25 ±25 4 300-500 7.7 5.8 10 4-30 ±30 4 280-520 8.3 5.8 8 >96 7-25 ±25 7 300-500 13 10 10 7-30 ±30 7 280-520 14 10 8 10-25 ±25 10 300-500 19 14 10 10-30 ±30 10 280-520 20 14 8 15-25 ±25 15 300-500 29 22 10 15-30 ±30 15 280-520 31 22 8 20-25 ±25 20 300-500 39 29 10 20-30 ±30 20 280-520 41 29 8 30-25 ±25 30 300-500 57 43 10 30-30 ±30 30 280-520 61 43 8 45-25 ±25 45 300-500 86 65 10 45-30 ±30 45 280-520 93 65 8 60-25 ±25 60 300-500 116 87 10 60-30 ±30 60 280-520 4 87 8 80-25 ±25 80 300-500 155 116 10 80-30 ±30 80 280-520 165 116 8 90-25 ±25 90 300-500 173 130 10 90-30 ±30 90 280-520 185 130 8 105-25 ±25 105 300-500 203 152 10 105-30 ±30 105 280-520 217 152 8 0-25 ±25 0 300-500 231 173 10 0-30 ±30 0 280-520 247 173 8 135-25 ±25 135 300-500 260 195 10 22 90 22 96 22 110 23 155 23 180 23 200 31 310 40 430 41 490 41 580 44 710 44 880 44 910 44 950 23

Orion three-phase 2-250kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range +15%/-25% 4-15/25 +15/-25 4 300-460 7.7 5.8 >96 14 22 100 7-15/25 +15/-25 7 300-460 13 10 >96 14 22 110 10-15/25 +15/-25 10 300-460 19 14 >96 14 22 0 15-15/25 +15/-25 15 300-460 29 22 14 23 165 20-15/25 +15/-25 20 300-460 39 29 14 23 190 30-15/25 +15/-25 30 300-460 57 43 14 23 220 45-15/25 +15/-25 45 300-460 87 65 14 31 330 60-15/25 +15/-25 60 300-460 116 87 14 40 450 80-15/25 +15/-25 80 300-460 155 116 14 41 510 105-15/25 +15/-25 105 300-460 203 152 14 41 600 Input variation range +15%/-35% 3-15/35 +15/-35 3 260-460 6.6 4.3 >96 10 22 100 4-15/35 +15/-35 4 260-460 8.9 5.8 >96 10 22 110 7-15/35 +15/-35 7 260-460 15 10 >96 10 22 0 10-15/35 +15/-35 10 260-460 22 14 10 23 165 15-15/35 +15/-35 15 260-460 34 22 10 23 190 20-15/35 +15/-35 20 260-460 45 29 10 23 220 30-15/35 +15/-35 30 260-460 66 43 10 31 330 45-15/35 +15/-35 45 260-460 100 65 10 40 450 60-15/35 +15/-35 60 260-460 134 87 10 41 510 80-15/35 +15/-35 80 260-460 178 116 10 41 600 Input variation range +15%/-45% 2-15/45 +15/-45 2 220-460 5.3 2.9 >96 8 22 100 3-15/45 +15/-45 3 220-460 7.8 4.3 >96 8 22 110 4-15/45 +15/-45 4 220-460 11 5.8 >96 8 22 0 7-15/45 +15/-45 7 220-460 18 10 8 23 165 10-15/45 +15/-45 10 220-460 25 14 8 23 190 15-15/45 +15/-45 15 220-460 39 22 8 23 220 20-15/45 +15/-45 20 220-460 53 29 8 31 330 30-15/45 +15/-45 30 220-460 78 43 8 40 450 45-15/45 +15/-45 45 220-460 118 65 8 41 510 60-15/45 +15/-45 60 220-460 158 87 8 41 600 Output current Efficiency h Speed regulation Enclosure Weight 24

25

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Orion Plus three-phase 30-50kVA Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to 100% Admitted load imbalance 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion from 210V to 255V (L-N) / from 360V to 440V (L-L) Natural air ventilation (aided with fans over 45 C) -25/+45 C -25/+60 C 200% 2 min. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Over protection IP21 Input & output digital multimetre Indoor Output class II surge arrestor Soft start through supercapacitors in case of blackout A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 26

Orion Plus three-phase 30-50kVA ORION Plus stabilisers can be chosen to match different ranges of input fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through different internal connections. They are housed in modular cabinets suitable for any industrial environment and able to tolerate mechanical stress that may occur during transport and installation. The ORION Plus stabilisers regulate the output independently on each phase. Similarly to the Orion stabilisers, the stabilisers can supply any single-phase, bi-phase and three-phase load even in case of and up to 100% unbalanced load current and asymmetrical mains distribution. In this configuration, the presence of the neutral wire is required. The stabiliser can also operate without neutral wire by adding a device able to generate it (D/zn or D /yn isolating transformer or neutral point reactor). The stabilisers are cooled via natural air ventilation, assisted by extracting fans when the cabinet internal temperature exceeds 45 C). The measuring instrumentation is incorporated in a control panel on the cabinet door and consists of two multi-task digital line analysers. Such instruments are able to provide with information regarding the status of the lines upstream and downstream the stabiliser such as phase and linked s, current, power factor, active power, apparent power, reactive power, etc. The operating status of the stabiliser can be easily monitored by means of the LED interface on the front panel, which displays all the information regarding the operating of the three phases and the possible alarms. LED lights signal 'power on', reaching of regulation limits and direction of regulation (increase/decrease). Alarms for minimum and maximum s, maximum current, overtemperature and ventilation failure are also indicated. The alarm indicators are accompanied by an acoustic alarm. Up to 250kVA ±15%, an automatic circuit breaker is mounted on the regulation circuit to protect against overload and short circuit on the regulator. From 300kVA ±15%, an electronic regulator protection system activates in case of overload on the regulator. In such condition, the load supply is not interrupted, but the stabiliser output is automatically set to the lower between the mains and the pre-set output. The service continuity is guaranteed, although the is not stabilised. When the overload condition ceases to exist, the stabiliser switches automatically back to regular functioning. The auxiliary circuits are protected by fuses. The control logic, performed on the true RMS, is based on the 2-way DSP microprocessor. The unit parameters and the output reference can be set by using a personal computer, thus allowing for dealing directly in the field with any problems related to stability. All ORION Plus stabilisers are provided with Class II SPD surge arrestors.. 27

Orion Plus three-phase 30-50kVA Rating in relation to the input variation percentage ±15% ±20% ±25% ±30% +15%/-35% +15%/-45% 80 60 45 30 45 30 105 80 60 45 60 45 135 105 80 60 80 60 150 0 90 80 90 80 175 135 105 90 105 90 200 150 0 105 0 105 250 175 135 0 135 0 320 250 200 150 200 150 300 250 200 250 200 500 300 250 300 250 630 500 300 300 800 630 500 500 1000 800 630 500 630 500 50 1000 800 630 800 630 28

Orion Plus three-phase 30-50kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±20%/±15% 60-20 ±20 60 320-480 109 86 80-15 ±15 80 340-460 136 116 16 80-20 ±20 80 320-480 145 116 105-15 ±15 105 340-460 179 152 16 105-20 ±20 105 320-480 190 152 135-15 ±15 135 340-460 229 195 16 0-20 ±20 0 320-480 216 173 14 150-15 ±15 150 340-460 255 217 18 135-20 ±20 135 320-480 244 195 14 175-15 ±15 175 340-460 298 253 18 150-20 ±20 150 320-480 271 217 14 200-15 ±15 200 340-460 340 289 18 175-20 ±20 175 320-480 316 253 14 250-15 ±15 250 340-460 425 361 18 250-20 ±20 250 320-480 446 361 15 320-15 ±15 320 340-460 544 462 20 300-20 ±20 300 320-480 543 434 15-15 ±15 340-460 680 578 20-20 ±20 320-480 723 578 15 500-15 ±15 500 340-460 851 723 20 500-20 ±20 500 320-480 904 723 15 630-15 ±15 630 340-460 1071 910 20 630-20 ±20 630 320-480 1138 910 18 800-15 ±15 800 340-460 1360 1156 24 800-20 ±20 800 320-480 1445 1156 18 1000-15 ±15 1000 340-460 1700 1445 24 1000-20 ±20 1000 320-480 1806 1445 18 50-15 ±15 50 340-460 25 1806 24 51 430 51 490 51 580 55 710 55 760 55 850 55 1000 55 00 55 1300 53 1 67 1600 62 2000 62 2200 63 2 29

Orion Plus three-phase 30-50kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Speed regulation [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Enclosure Weight Input variation range ±30%/±25% 30-30 ±30 30 280-520 61 43 8 45-25 ±25 45 300-500 86 65 10 45-30 ±30 45 280-520 93 65 8 60-25 ±25 60 300-500 116 87 10 60-30 ±30 60 280-520 4 87 8 80-25 ±25 80 300-500 155 116 10 80-30 ±30 80 280-520 166 116 9 90-25 ±25 90 300-500 173 130 11 90-30 ±30 90 280-520 185 130 9 105-25 ±25 105 300-500 203 152 11 105-30 ±30 105 280-520 217 152 9 0-25 ±25 0 300-500 231 173 11 0-30 ±30 0 280-520 247 173 9 135-25 ±25 135 300-500 260 195 11 150-30 ±30 150 280-520 310 217 10 200-25 ±25 200 300-500 385 289 200-30 ±30 200 280-520 413 289 10 250-25 ±25 250 300-500 481 361 250-30 ±30 250 280-520 515 361 10 300-25 ±25 300 300-500 579 434 300-30 ±30 300 280-520 620 434 10-25 ±25 300-500 771 578-30 ±30 280-520 826 578 500-25 ±25 500 300-500 963 723 15 500-30 ±30 500 280-520 1032 723 630-25 ±25 630 300-500 14 910 15 630-30 ±30 630 280-520 1300 910 800-25 ±25 800 300-500 1541 1156 15 51 430 51 490 51 580 55 710 55 760 55 850 55 950 55 00 55 1300 53 1 67 1600 62 2000 62 2200 63 2 30

Orion Plus three-phase 30-50kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range +15%/-35% 45-15/35 +15/-35 45 260-460 100 65 10 51 470 60-15/35 +15/-35 60 260-460 134 87 10 51 550 80-15/35 +15/-35 80 260-460 178 116 10 51 600 90-15/35 +15/-35 90 260-460 200 130 11 55 850 105-15/35 +15/-35 105 260-460 234 152 11 55 950 0-15/35 +15/-35 0 260-460 266 173 11 55 1050 135-15/35 +15/-35 135 260-460 300 195 11 55 00 200-15/35 +15/-35 200 260-460 445 289 55 1500 250-15/35 +15/-35 250 260-460 555 361 52 1650 300-15/35 +15/-35 300 260-460 668 434 52 1750-15/35 +15/-35 260-460 889 578 62 2100 500-15/35 +15/-35 500 260-460 1111 723 15 63 2900 630-15/35 +15/-35 630 260-460 1 910 15 63 3050 800-15/35 +15/-35 800 260-460 1778 1156 15 64 3800 Input variation range +15%/-45% 30-15/45 +15/-45 30 220-460 78 43 8 51 470 45-15/45 +15/-45 45 220-460 118 65 8 51 550 60-15/45 +15/-45 60 220-460 158 87 8 51 600 80-15/45 +15/-45 80 220-460 211 116 9 55 850 90-15/45 +15/-45 90 220-460 236 130 9 55 950 105-15/45 +15/-45 105 220-460 276 152 9 55 1050 0-15/45 +15/-45 0 220-460 315 173 9 55 50 150-15/45 +15/-45 150 220-460 395 217 10 55 1450 200-15/45 +15/-45 200 220-460 525 289 10 52 1650 250-15/45 +15/-45 250 220-460 656 361 10 52 1800 300-15/45 +15/-45 300 220-460 789 434 10 62 2200-15/45 +15/-45 220-460 1051 578 63 3000 500-15/45 +15/-45 500 220-460 1315 723 63 3200 630-15/45 +15/-45 630 220-460 1655 910 64 0 Output current Efficiency h Speed regulation Enclosure Weight 31

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 3YEARS Digital stabiliser Sirius three-phase 60-6000kVA Standard features Voltage stabilisation Output selectable via display, PC and/or Ethernet Independent phase control from 210V to 255V (L-N) from 360V to 440V (L-L) Frequency 50/60Hz ±5% Admitted load variation Up to 100% Admitted load imbalance 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion Natural air ventilation (aided with fans over 45 C) -25/+45 C -25/+60 C 200% 2 min. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Regulator overload protection Communication system Over protection IP21 Input and output digital multimetre with RS485 port LCD display Indoor Digital control Ethernet / GPRS / USB / MODBUS TCP/IP Input class I surge arrestor Output class II surge arrestor Soft start through supercapacitors in case of blackout A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 32

Sirius three-phase 60-6000kVA SIRIUS stabilisers are equipped with columnar regulators which make possible to achieve high ratings (up to 6000kVA) and a solid and reliable construction, so that any industrial need can be met. The three-phase SIRIUS line allows for the choice of several input variation percentages within a broad range (from +30% down to -45%). The SIRIUS type can be used when the mains phases are asymmetrical and it is suitable for supplying unbalanced three-phase loads, two-phase loads and single-phase loads. The SIRIUS stabilisers perform an independent regulation on each phase. The presence of the neutral wire is therefore required. The stabiliser can also operate without neutral wire by adding a D/zn isolating transformer or a neutral point reactor). The stabilisers are air cooled (natural convection up to 45 C, assisted by fans when the temperature exceeds said value). The measuring instrumentation is incorporated in the control panel on the cabinet door and consists of two multi-task digital line analysers. Such instruments are able to provide with information regarding the status of the lines upstream and downstream the stabiliser such as phase and linked current, frequency, power factor, active power, apparent power and reactive power. The readings are stored locally by the control system and (if the Ethernet connection is established) sent to a server at Ortea HQ, thus providing the Service centre with the necessary information. The front panel is provided with a user-friendly LED interface which allows for a complete monitoring of the unit. LED lights are provided for each phase signalling «power on», reaching of regulation limits and direction of regulation (increase/decrease). Alarms for minimum and maximum s, maximum current, over-temperature, cabinet overheating and maintenance required are also indicated. The alarm indicators are accompanied by an acoustic alarm. Monitoring activities can be run remotely by installing on a PC (connected to the stabiliser via Ethernet) the STABIMON software provided with the unit. It is also possible to communicate with the stabiliser with the Modbus TCP/IP protocol (standard communication protocol between electronic industrial equipment) via an Ethernet connection with RJ45 cable. The control system is able to interface with the Internet thanks to its capability to connect with ETHERNET and GPRS protocols. This allows for a remote monitoring of the equipment made by ORTEA at its headquarters, thus guaranteeing prompt assistance worldwide. The control system is also provided with two USB ports for downloading the stored data on a memory key and uploading setting parameters if operating modifications in the system are needed. Also, the control firmware can be updated either through the USB port or via the Ethernet connection. The SIRIUS stabiliser is provided with an electronic regulator protection system activates in case of overload on the regulator. In such condition the load supply is not interrupted, but the stabiliser output is automatically set to the lower between the mains and the pre-set output. The service continuity is guaranteed, although the is not stabilised. When the overload condition ceases to exist, the stabiliser switches automatically back to regular functioning. The control logic, performed on the true RMS, is based on two 2-way DSP microprocessor (one performing the control and the other one managing the measurements). The user can monitor the system and set all the parameters of the stabiliser via a PC connection. The whole system is supervised by a third bodyguard microprocessor controlling the correct functioning of the other microprocessors. The output is reset to the minimum value in case of blackout by means of supercapacitor banks in order to ensure the correct shutdown. All SIRIUS stabilisers are provided with Class I and Class II SPD surge arrestors. 33

Sirius three-phase 60-6000kVA Remote communication system The all-in-one control card manages also the remote communication to the stabiliser. The card is fitted with a local display (showing alarms and setting parameters) and with a keypad used to interact with the card itself. This remote data monitoring system enables the user and Ortea Service Centre the chance of monitoring the stabiliser on-line wherever installed by means of the STABIMON dedicated software, supplied with each unit. Alternatively, the communication with the stabiliser can be established via the Modbus TCP/IP protocol. Should the Ethernet connection not be available, the remote communication can be performed via an embedded GPRS modem. A common SIM data card purchased locally and inserted in the modem allows for a simple data transmission. STABIMON software STABIMON is the software managing the communication with the stabiliser. The program can be run when the user wishes to communicate with the stabiliser or simply read the collected information. In a single page, the dashboard provides the main information concerning, current, power and alarm status. In the top left-hand side of the page, each phase input, current and cos are shown. In the top righthand side, the corresponding output parameters are shown. In the area between the input and output parameters, mains frequency and general information for the stabiliser identification are displayed. Below said data, the communication errors (if any) are listed. The lower part of the page is used to visualise input and output active, reactive and apparent powers, s and temperature measured on the base board and the reproduction of the LED status as available on the stabiliser control panel. The LEDs are red in case of error. Graphs and statistics relevant to the stabiliser operating status can also be displayed. 34

Sirius three-phase 60-6000kVA Rating in relation to the input variation percentage ±10% ±15% ±20% ±25% ±30% +15%/-35% +15%/-45% 200 5 100 80 60 80 60 250 160 5 100 80 100 80 320 200 160 5 100 5 100 250 200 160 5 160 5 500 320 250 200 160 200 160 630 320 250 200 250 200 800 500 320 250 320 250 1000 630 500 320 320 50 800 630 500 500 1600 1000 800 630 500 630 500 2000 50 1000 800 630 800 630 2500 1600 50 1000 800 1000 800 3200 2000 1600 50 1000 50 1000 0 2500 2000 1600 50 1600 50 5000 3200 2500 2000 1600 2000 1600 6000 0 3200 2500 2000 2500 2000 35

Sirius three-phase 60-6000kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range ±10% 200-10 ±10 200 360-440 321 289 30 54 650 250-10 ±10 250 360-440 401 361 30 54 670 320-10 ±10 320 360-440 514 462 30 55 900-10 ±10 360-440 642 578 30 55 950 500-10 ±10 500 360-440 803 723 30 55 1050 630-10 ±10 630 360-440 1011 910 30 55 1300 800-10 ±10 800 360-440 84 1156 30 53 1 1000-10 ±10 1000 360-440 1606 1445 30 62 1700 50-10 ±10 50 360-440 2007 1806 36 62 2200 1600-10 ±10 1600 360-440 2569 23 36 63 2 2000-10 ±10 2000 360-440 3211 2890 36 64 3000 2500-10 ±10 2500 360-440 4014 3613 36 70 0 3200-10 ±10 3200 360-440 5138 4624 36 70 4300 0-10 ±10 0 360-440 6422 5780 45 80 6000 5000-10 ±10 5000 360-440 8028 7225 45 80 7300 6000-10 ±10 6000 360-440 9634 8671 54 90 11000 Output current Efficiency h Speed regulation Enclosure Weight 36

Sirius three-phase 60-6000kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range ±20%/±15% 100-20 ±20 100 320-480 180 144 15 5-15 ±15 5 340-460 213 181 20 54 650 5-20 ±20 5 320-480 226 181 15 160-15 ±15 160 340-460 272 231 20 54 670 160-20 ±20 160 320-480 289 231 15 200-15 ±15 200 340-460 340 289 20 55 900 200-20 ±20 200 320-480 361 289 15 250-15 ±15 250 340-460 425 361 20 55 950 250-20 ±20 250 320-480 452 361 15 320-15 ±15 320 340-460 544 462 20 55 1050 320-20 ±20 320 320-480 578 462 15-15 ±15 340-460 680 578 20 55 1300-20 ±20 320-480 722 578 15 500-15 ±15 500 340-460 851 723 20 53 1 500-20 ±20 500 320-480 903 723 15 630-15 ±15 630 340-460 1071 910 20 62 1700 630-20 ±20 630 320-480 1138 910 18 800-15 ±15 800 340-460 1360 1156 24 62 2200 800-20 ±20 800 320-480 1445 1156 18 1000-15 ±15 1000 340-460 1700 1445 24 63 2 1000-20 ±20 1000 320-480 1806 1445 18 50-15 ±15 50 340-460 25 1806 24 64 3000 50-20 ±20 50 320-480 2258 1806 18 1600-15 ±15 1600 340-460 2720 23 24 70 0 1600-20 ±20 1600 320-480 2890 23 18 2000-15 ±15 2000 340-460 3 2890 24 70 4300 2000-20 ±20 2000 320-480 3613 2890 22 80 6000 2500-15 ±15 2500 340-460 4251 3613 30 80 6000 2500-20 ±20 2500 320-480 4516 3613 22 80 7300 3200-15 ±15 3200 340-460 5440 4624 30 80 7300 3200-20 ±20 3200 320-480 5780 4624 27 90 11000 0-15 ±15 0 340-460 6800 5780 36 90 11000 Output current Efficiency h Speed regulation Enclosure Weight 37

Sirius three-phase 60-6000kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range ±30%/±25% 60-30 ±30 60 280-520 4 87 10 80-25 ±25 80 300-500 154 116 54 650 80-30 ±30 80 280-520 165 116 10 100-25 ±25 100 300-500 193 144 54 670 100-30 ±30 100 280-520 206 144 10 5-25 ±25 5 300-500 241 181 55 900 5-30 ±30 5 280-520 258 181 10 160-25 ±25 160 300-500 308 231 55 950 160-30 ±30 160 280-520 330 231 10 200-25 ±25 200 300-500 385 289 55 1050 200-30 ±30 200 280-520 413 289 10 250-25 ±25 250 300-500 482 361 55 1300 250-30 ±30 250 280-520 516 361 10 320-25 ±25 320 300-500 617 462 53 1 320-30 ±30 320 280-520 661 462 10-25 ±25 300-500 770 578 62 1700-30 ±30 280-520 826 578 500-25 ±25 500 300-500 963 723 15 62 2200 500-30 ±30 500 280-520 1032 723 630-25 ±25 630 300-500 14 910 15 63 2 630-30 ±30 630 280-520 1300 910 800-25 ±25 800 300-500 1541 1156 15 64 3000 800-30 ±30 800 280-520 1651 1156 1000-25 ±25 1000 300-500 1927 1445 15 70 0 1000-30 ±30 1000 280-520 2064 1445 50-25 ±25 50 300-500 2408 1806 15 70 4300 50-30 ±30 50 280-520 2580 1806 15 80 6000 1600-25 ±25 1600 300-500 3083 23 18 80 6000 1600-30 ±30 1600 280-520 3303 23 15 80 7300 2000-25 ±25 2000 300-500 3853 2890 18 80 7300 2000-30 ±30 2000 280-520 4130 2892 18 90 11000 2500-25 ±25 2500 300-500 4817 3613 22 90 11000 Output current Efficiency h Speed regulation Enclosure Weight 38

Sirius three-phase 60-6000kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range +15%/-35% 80-15/35 +15/-35 80 260-460 178 116 54 770 100-15/35 +15/-35 100 260-460 222 144 54 800 5-15/35 +15/-35 5 260-460 278 181 55 1050 160-15/35 +15/-35 160 260-460 356 231 55 1150 200-15/35 +15/-35 200 260-460 444 289 55 50 250-15/35 +15/-35 250 260-460 556 361 52 1700 320-15/35 +15/-35 320 260-460 711 462 52 1800-15/35 +15/-35 260-460 889 578 63 2100 500-15/35 +15/-35 500 260-460 1111 723 15 63 2900 630-15/35 +15/-35 630 260-460 1 910 15 64 3050 800-15/35 +15/-35 800 260-460 1778 1156 15 70 3800 1000-15/35 +15/-35 1000 260-460 2223 1445 15 70 4450 50-15/35 +15/-35 50 260-460 2779 1806 15 72 4800 1600-15/35 +15/-35 1600 260-460 3557 23 18 82 7700 2000-15/35 +15/-35 2000 260-460 4446 2890 18 82 9050 2500-15/35 +15/-35 2500 260-460 5558 3613 22 92 13500 Input variation range +15%/-45% 60-15/45 +15/-45 60 220-460 158 87 10 54 850 80-15/45 +15/-45 80 220-460 211 116 10 54 900 100-15/45 +15/-45 100 220-460 262 144 10 55 00 5-15/45 +15/-45 5 220-460 329 181 10 55 50 160-15/45 +15/-45 160 220-460 420 231 10 55 1 200-15/45 +15/-45 200 220-460 525 289 10 52 1900 250-15/45 +15/-45 250 220-460 656 361 10 52 2000 320-15/45 +15/-45 320 220-460 840 462 10 63 2300-15/45 +15/-45 220-460 1051 578 63 3200 500-15/45 +15/-45 500 220-460 1315 723 64 3 630-15/45 +15/-45 630 220-460 1655 910 70 4200 800-15/45 +15/-45 800 220-460 2102 1156 70 4900 1000-15/45 +15/-45 1000 220-460 2627 1445 72 5300 50-15/45 +15/-45 50 220-460 3284 1806 15 82 8700 1600-15/45 +15/-45 1600 220-460 4204 23 15 82 10100 2000-15/45 +15/-45 2000 220-460 5254 2890 18 92 15000 Output current Efficiency h Speed regulation Enclosure Weight 39

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 5YEARS Digital stabiliser Sirius Advance three-phase 60-0kVA Standard features Voltage stabilisation Output selectable via display, PC and/or Ethernet Independent phase control from 210V to 255V (L-N) from 360V to 440V (L-L) Frequency 50/60Hz ±5% Admitted load variation Up to 100% Admitted load imbalance 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion Natural air ventilation (aided with fans over 45 C) 25/+45 C 25/+60 C 200% 2 min. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Regulator overload protection Communication system Over protection Total protection by-pass kit Integrated automatic power factor correction system IP21 Input and output digital multimetre with RS485 port LCD display Reactive power regulator Indoor Digital control Ethernet / GPRS / USB / MODBUS TCP/IP input class I surge arrestor Output class II surge arrestor Soft start through supercapacitors in case of blackout Input automatic circuit breaker to protect against short-circuit Bypass switch made of an interlocked automatic circuit breaker to protect against short-circuit Output motorized automatic circuit breaker to protect against overload, over, under, phase sequence error and phase failure Based on high energy density metallised polypropylene three-phase capacitors (Un = 525V) Three-phase blocking reactor (tuning frequency: 180Hz) A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 40

Sirius advance three-phase 60-0kVA SIRIUS Advance stabilisers derive from the SIRIUS type, of which they maintain the main technical characteristics. The standard integration of some functions and accessories usually offered as optional, complete and enrich the equipment. The additional features are: Input automatic circuit breaker; Bypass switch via an interlocked automatic circuit breaker; Output interlocked motorized automatic circuit breaker; Integrated automatic power factor correction system. The input automatic circuit breaker (QF1) ensures protection against failure and/or short-circuits inside the unit. The bypass automatic circuit breaker (QF2) protects the line supplying the load against overload and shortcircuits in bypass condition. The output motorized automatic circuit breaker (QF3), interlocked with the bypass switch, protects against overload, short-circuit, over, under, phase sequence error and phase failure. The integrated automatic Power Factor Correction system maintains the power factor value (cos φ) to a high level ensuring the known advantages for the users but also affecting the sizing of the stabiliser. The PFC system exploits high energy density metallised polypropylene three-phase capacitors (Un=525V) exclusively thus guaranteeing robustness and reliability. The addition of blocking reactors (detuned filters) eliminates undesired harmonics and protects the capacitors. The reactive power controller is mounted on the external control synoptic panel. INPUT QF1 AUTOMATIC CIRCUIT BREAKER DVS QF2 QF3 AUTOMATIC CIRCUIT BREAKER PFC OUTPUT Rating in relation to the input variation percentage ±15% ±20% ±25% ±30% +15%/-35% +15%/-45% 5 100 80 60 80 60 160 5 100 80 100 80 200 160 5 100 5 100 250 200 160 5 160 5 320 250 200 160 200 160 320 250 200 250 200 500 320 250 320 250 630 500 320 320 800 630 500 500 1000 800 630 500 630 500 50 1000 800 630 800 630 1600 50 1000 800 1000 800 2000 1600 50 1000 50 1000 2500 2000 1600 50 1600 50 3200 2500 2000 1600 2000 1600 0 3200 2500 2000 2500 2000 41

Sirius advance three-phase 60-0kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range ±20%/±15% 100-20 ±20 100 320-480 180 144 15 5-15 ±15 5 340-460 213 181 20 53 880 5-20 ±20 5 320-480 226 181 15 160-15 ±15 160 340-460 272 231 20 53 900 160-20 ±20 160 320-480 289 231 15 200-15 ±15 200 340-460 340 289 20 56 1150 200-20 ±20 200 320-480 361 289 15 250-15 ±15 250 340-460 425 361 20 56 20 250-20 ±20 250 320-480 452 361 15 320-15 ±15 320 340-460 544 462 20 50 1450 320-20 ±20 320 320-480 578 462 15-15 ±15 340-460 680 578 20 50 1700-20 ±20 320-480 722 578 15 500-15 ±15 500 340-460 851 723 20 57 1880 500-20 ±20 500 320-480 903 723 15 630-15 ±15 630 340-460 1071 910 20 64 2200 630-20 ±20 630 320-480 1138 910 18 800-15 ±15 800 340-460 1360 1156 24 64 2720 800-20 ±20 800 320-480 1445 1156 18 1000-15 ±15 1000 340-460 1700 1445 24 65 2950 1000-20 ±20 1000 320-480 1806 1445 18 50-15 ±15 50 340-460 25 1806 24 72 4240 50-20 ±20 50 320-480 2258 1806 18 1600-15 ±15 1600 340-460 2720 23 24 73 5500 1600-20 ±20 1600 320-480 2890 23 18 2000-15 ±15 2000 340-460 3 2890 24 73 5980 2000-20 ±20 2000 320-480 3613 2890 22 82 7840 2500-15 ±15 2500 340-460 4251 3613 30 82 7840 2500-20 ±20 2500 320-480 4516 3613 22 84 9600 3200-15 ±15 3200 340-460 5440 4624 30 84 9600 3200-20 ±20 3200 320-480 5780 4624 27 93 800 0-15 ±15 0 340-460 6800 5780 36 93 800 Output current Efficiency h Speed regulation Enclosure Weight 42

Sirius advance three-phase 60-0kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range ±30%/±25% 60-30 ±30 60 280-520 4 87 10 80-25 ±25 80 300-500 154 116 53 880 80-30 ±30 80 280-520 165 116 10 100-25 ±25 100 300-500 193 144 53 900 100-30 ±30 100 280-520 206 144 10 5-25 ±25 5 300-500 241 181 56 1150 5-30 ±30 5 280-520 258 181 10 160-25 ±25 160 300-500 308 231 56 20 160-30 ±30 160 280-520 330 231 10 200-25 ±25 200 300-500 385 289 50 1450 200-30 ±30 200 280-520 413 289 10 250-25 ±25 250 300-500 482 361 50 1700 250-30 ±30 250 280-520 516 361 10 320-25 ±25 320 300-500 617 462 57 1880 320-30 ±30 320 280-520 661 462 10-25 ±25 300-500 770 578 64 2200-30 ±30 280-520 826 578 500-25 ±25 500 300-500 963 723 15 64 2720 500-30 ±30 500 280-520 1032 723 630-25 ±25 630 300-500 14 910 15 65 2950 630-30 ±30 630 280-520 1300 910 800-25 ±25 800 300-500 1541 1156 15 72 4240 800-30 ±30 800 280-520 1651 1156 1000-25 ±25 1000 300-500 1927 1445 15 73 5500 1000-30 ±30 1000 280-520 2064 1445 50-25 ±25 50 300-500 2408 1806 15 73 5980 50-30 ±30 50 280-520 2580 1806 15 82 7840 1600-25 ±25 1600 300-500 3083 23 18 82 7840 1600-30 ±30 1600 280-520 3303 23 15 84 9600 2000-25 ±25 2000 300-500 3853 2890 18 84 9600 2000-30 ±30 2000 280-520 4130 2892 18 93 800 2500-25 ±25 2500 300-500 4817 3613 22 93 800 Output current Efficiency h Speed regulation Enclosure Weight 43

Sirius advance three-phase 60-0kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% [%] [kva] [V] [A] [V] [A] [%] [ms/v] Type [kg] Input variation range +15%/-35% 80-15/35 +15/-35 80 260-460 178 116 53 1000 100-15/35 +15/-35 100 260-460 222 144 53 1030 5-15/35 +15/-35 5 260-460 278 181 56 1300 160-15/35 +15/-35 160 260-460 356 231 56 1420 200-15/35 +15/-35 200 260-460 444 289 56 1650 250-15/35 +15/-35 250 260-460 556 361 58 2100 320-15/35 +15/-35 320 260-460 711 462 58 2220-15/35 +15/-35 260-460 889 578 65 2600 500-15/35 +15/-35 500 260-460 1111 723 15 65 3420 630-15/35 +15/-35 630 260-460 1 910 15 71 3700 800-15/35 +15/-35 800 260-460 1778 1156 15 72 5040 1000-15/35 +15/-35 1000 260-460 2223 1445 15 73 5950 50-15/35 +15/-35 50 260-460 2779 1806 15 75 6480 1600-15/35 +15/-35 1600 260-460 3557 23 18 84 9540 2000-15/35 +15/-35 2000 260-460 4446 2890 18 86 11350 2500-15/35 +15/-35 2500 260-460 5558 3613 22 95 15500 Input variation range +15%/-45% 60-15/45 +15/-45 60 220-460 158 87 10 53 1080 80-15/45 +15/-45 80 220-460 211 116 10 53 1130 100-15/45 +15/-45 100 220-460 262 144 10 56 1450 5-15/45 +15/-45 5 220-460 329 181 10 56 1520 160-15/45 +15/-45 160 220-460 420 231 10 56 1800 200-15/45 +15/-45 200 220-460 525 289 10 58 2300 250-15/45 +15/-45 250 220-460 656 361 10 58 2420 320-15/45 +15/-45 320 220-460 840 462 10 65 2800-15/45 +15/-45 220-460 1051 578 65 3720 500-15/45 +15/-45 500 220-460 1315 723 71 4050 630-15/45 +15/-45 630 220-460 1655 910 72 5440 800-15/45 +15/-45 800 220-460 2102 1156 73 6 1000-15/45 +15/-45 1000 220-460 2627 1445 75 6980 50-15/45 +15/-45 50 220-460 3284 1806 15 84 10540 1600-15/45 +15/-45 1600 220-460 4204 23 15 86 2000-15/45 +15/-45 2000 220-460 5254 2890 18 95 16800 Output current Efficiency h Speed regulation Enclosure Weight 44

Digital stabiliser Accessories The characteristics described so far are relevant to the standard stabilisers. Accessories to perform specific tasks are available on request. Combinations or one or more of the accessories listed in the following might result in an increase of the stabiliser overall dimensions. Accessories Interrupting devices Over/under protection Manual bypass line Total protection kit Input isolating transformer Integrated automatic power factor correction system SPD surge arrestors EMI/RFI filters Neutral point reactors IP54 protection degree for indoor and outdoor installation 45

Interrupting devices Every stabiliser can be fitted with an automatic circuit breaker with thermal and magnetic release on the input and/or on the output. The input breaker protects the stabiliser and the downstream line against potential short-circuits on the input line. The output breaker protects the stabiliser against potential overload. The input breaker is sized according to the maximum input current, whilst the output one is sized in relation to the stabiliser rated current. Accessories Over/under protection This circuit offers a double protection by: delaying the connection to the load each time the stabiliser switches on, so that the user can undergo a smooth start-up with an already stabilised ; protecting the load from surges, sags and overload by disconnecting the load from the stabiliser. The protection intervenes when the output is outside the set range (with regard to the rated value). When the supply goes back to the regular value, the load is automatically re-connected. Up to 320A, the protection is obtained with contactors. From A upwards, an automatic motorised circuit breaker is used. The protection must be sized according to the stabiliser nominal current. Nominal Breaking Additional module current capacity Length Weight [A] [ka] [mm] [kg] 10 6 not needed 16 6 not needed 20 6 not needed 25 6 not needed 32 6 not needed 40 6 not needed 50 6 not needed 63 6 not needed 80 10 not needed 100 16 not needed 5 16 not needed 160 25 not needed 200 36 not needed 250 36 not needed 320 36 not needed 36 not needed 500 36 not needed 630 36 not needed 800 50 not needed 1000 50 not needed 50 50 not needed 1600 50 not needed 2000 85 600 90 2500 85 600 90 3200 85 600 90 0 100 600 90 5000 100 00 200 6300 100 00 200 Nominal Additional module current Length Weight [A] [mm] [kg] 10 not needed 16 not needed 20 not needed 25 not needed 32 not needed 40 not needed 50 not needed 63 not needed 80 not needed 100 not needed 5 not needed 160 not needed 200 not needed 250 not needed 320 not needed not needed 500 not needed 630 not needed 800 not needed 1000 not needed 50 not needed 1600 not needed 2000 600 90 2500 600 90 3200 600 90 0 00 200 5000 00 200 6300 00 200 46

Accessories Manual bypass line The bypass circuit enables the stabiliser to be segregated from the line supplying the load. The operator can therefore access the internal components and perform maintenance or repairing sessions without having to disconnect the load. For the duration of the bypass condition, the load is directly fed by the mains: the is therefore not stabilised. The bypass line configuration can be: 1. I-0-II changeover interlocked switch (QS) 2. Input disconnecting switch (QS1) Output I-0-II changeover interlocked switch (QS2) INPUT QS DVS I 0 II QS OUTPUT INPUT QS1 DVS I 0 II QS2 OUTPUT VOLTAGE STABILISER CHANGEOVER INTERLOCKED SWITCH DISCONNECTING SWITCH VOLTAGE STABILISER CHANGEOVER INTERLOCKED SWITCH Nominal Additional module current Length Weight [A] [mm] [kg] 10 not needed 16 not needed 20 not needed 25 not needed 32 not needed 40 not needed 50 not needed 63 not needed 80 not needed 100 not needed Nominal Additional module current Length Weight [A] [mm] [kg] 5 70 160 70 200 70 250 70 320 70 70 500 70 630 600 90 800 600 90 1000 600 90 50 600 90 1600 600 90 2000 00 200 2500 00 200 47

Accessories Manual bypass line 3. Input automatic circuit breaker (QF1) Output I-0-II changeover interlocked switch (QS2) Nominal Additional module current Length Weight [A] [mm] [kg] INPUT QF1 AUTOMATIC CIRCUIT BREAKER DVS VOLTAGE STABILISER I 0 II QS2 CHANGEOVER INTERLOCKED SWITCH OUTPUT 5 70 160 70 200 70 250 70 320 70 70 500 600 90 630 600 90 800 600 90 1000 600 90 50 600 90 1600 00 200 2000 00 200 2500 00 200 48

Accessories Total protection kit The total protection kit includes: Input automatic circuit breaker (QF1); Bypass switch made of an interlocked automatic circuit breaker (QF2); Output interlocked motorized automatic circuit breaker (QF3). The input automatic circuit breaker protects against potential faults and/or short-circuits inside the unit. The bypass switch with automatic circuit breaker protects the load supplying line against overload and short-circuits in bypass condition. The output motorized circuit breaker (interlocked with the bypass circuit breaker) protects against overload, shortcircuit, over, under, phase sequence error and phase failure. INPUT QF1 AUTOMATIC CIRCUIT BREAKER DVS VOLTAGE STABILISER QF2 QF3 AUTOMATIC CIRCUIT BREAKER OUTPUT Current Additional module Input Output Length Weight [A] [A] [mm] [kg] 200 160 100 250 200 100 320 250 110 320 5 500 5 630 500 600 170 800 630 600 170 1000 800 600 200 50 1000 600 200 1600 50 600 200 2000 1600 00 630 2500 2000 00 640 3200 2500 00 650 0 3200 00 730 5000 0 1800 1100 6300 5000 1800 00 QF1: Input automatic circuit breaker. QF2: Bypass switch made of an interlocked automatic circuit breaker. QF3: Output automatic circuit breaker. QF3 is interlocked with QF2 by means of an individual key. When one of the breakers is closed, the other one is open and the closing spring cannot be manually loaded. 49

Accessories Input isolating transformer The input isolation transformer is the best solution to provide for: galvanic separation between the stabiliser and the mains delta/star or delta/zig-zag connection in order to cancel the 3rd and triplen harmonics and improve the balance of the phase s generation of a fixed and steady neutral point protection from over generated by connecting/disconnecting manoeuvres on the line The transformer is fitted with electrostatic screen between primary and secondary winding. It is also possible to have high insulation level (16kV) between input and output. Current Single-phase transformer for VEGA & ANTARES Power Cabinet (TRS+DVS) Additional weight [A] [kva] [tipo] [kg] 8 2 13 48 13 3 13 59 21 5 22 79 34 8 22 95 43 10 23 110 52 23 113 65 15 23 115 86 20 23 5 108 25 30 135 130 30 30 150 173 40 40 160 217 50 40 220 273 63 40 240 304 70 40 260 347 80 2x40 285 391 90 2x40 300 435 100 2x41 335 478 110 2x41 355 543 5 2x41 770 175 2x41 455 Current Dyn11 three-phase transformer for ORION Power Cabinet (TRS+DVS) Additional weight [A] [kva] [tipo] [kg] Dzn0 three-phase transformer for ORION PLUS, SIRIUS & SIRIUS ADVANCE Current Power Additional cabinet Additional weight [A] [kva] [tipo] [kg] 130 90 54 430 144 100 54 580 158 110 54 600 180 5 54 630 202 140 54 660 231 160 54 710 260 180 54 750 289 200 54 800 325 225 55 910 361 250 55 960 404 280 55 1020 462 320 55 1070 505 350 55 10 578 55 10 650 450 55 90 722 500 55 1430 910 630 61 1700 1156 800 61 2000 1445 1000 61 2450 1806 50 62 3100 23 1600 62 3600 2890 2x1000 63 4900 36 2x50 63 5800 4650 2x1600 80 7200 5780 2x2000 80 8600 7250 2x2500 91 10600 17 30 135 21 15 30 145 28 20 30 170 36 25 40 205 43 30 40 225 57 40 40 290 72 50 2x40 335 91 63 2x40 365 101 70 2x40 370 115 80 2x40 395 50

Accessories Integrated automatic power factor correction system DVS PFC Additional module Power Power Length Weight [kva] [kvar] [mm] [kg] 80 50 not needed 40 100 50 not needed 40 5 75 not needed 50 160 75 not needed 50 200 100 not needed 60 250 5 not needed 80 320 150 not needed 90 200 not needed 100 500 250 not needed 0 630 300 600 185 800 600 220 1000 500 600 240 50 600 600 300 1600 800 00 380 2000 1000 00 410 2500 50 00 550 3200 1600 00 750 0 2000 00 950 A PFC system can be integrated in the same cabinet with a stabiliser, offering the stabilisation and the correction of the power factor of the plant in the same solution. The result is a stabilised supply to the load and a higher power factor of the load itself, with the advantage of having available the maximum active power. ORTEA PFC systems exploit high energy density metallised polypropylene three-phase capacitors (Un=525V) exclusively thus guaranteeing robustness and reliability. 51

SPD surge arrestors SPD arrestors protect the load and the stabiliser against peaks of atmospheric or operational origin by discharging them to ground. The installation depends on the system configuration. For example, in case of high ratings the suggested sequence would be: spark-gap arresters followed by an isolating device (ideally an isolating transformer) and varistorbased arresters on the output. Accessories EMI/RFI filters The addition of EMI/RFI filters is a valid solution to remove the electromagnetic interferences generated by many electronic devices (power supplies, converters, motor drives ). Current [A] Type Discharge current Type Rated current [A] CLASS I ORTEA 50kA single-phase+n CLASS I ORTEA 50kA three-phase+n CLASS II ORTEA 40kA single-phase+n CLASS II ORTEA 40kA three-phase+n CLASS I DEHN 100kA single-phase+n CLASS I DEHN 200kA three-phase+n CLASS II DEHN 40kA single-phase+n CLASS II DEHN 40kA three-phase+n FL170.10.00 10 FL170.30.00 30 FL170.50.00 50 FL170.80.00 50 FL170.0.00 0 FL170.150.00 150 FL170.250.00 250 FL170.300.00 300 FL170..00 FL170.500.00 500 FL170.700.00 700 FL170.1000.00 1000 FL170.1600.00 1600 FL170.2500.00 2500 Neutral point reactor The neutral point reactor creates a reference neutral for the system when the input AC mains does not include the neutral connection or when a stable neutral is required to supply the load. The neutral point inductor is available for all the stabilisers. THREE-PHASE INPUT U1 V1 W1 VOLTAGE STABILISER U2 V2 W2 N N THREE-PHASE + NEUTRAL OUTPUT NEUTRAL POINT REACTOR 52

Accessories IP54 protection degree for indoor and outdoor installation IP54 indoor installation These units are equipped with air conditioning units to ensure the correct ventilation and cooling of the internal magnetic and electrical components. The cabinet is completely sealed: this makes the stabiliser suitable for operating in damp and dusty environments. IP54 outdoor installation ORTEA s stabilisers are also available for outdoor installation. 53

Cabinet size/industrial cabinets Type Dimensions [mm] W D H 11 210 200 280 430 260 13 300 570 280 14 350 610 600 Type Dimensions [mm] W D H 21 300 500 900 22 390 520 1050 23 410 670 00 Type Dimensions [mm] W D H 30 600 700 1300 31 600 700 1500 32 600 700 1700 33 830 700 1700 35 00 700 1300 36 00 700 1500 37 00 700 1700 Type Dimensions [mm] W D H 40 600 830 1500 41 600 830 1700 43 00 830 1500 44 00 830 1700 46 1800 830 1500 47 1800 830 1700 Type Dimensions [mm] W D H 50 2 800 1800 51 600 800 1800 52 1800 800 2000 53 00 800 2000 54 600 800 2000 55 00 800 1800 56 1800 800 1800 57 2 800 2000 58 3000 800 2000 59 3600 800 2100 Type Dimensions [mm] W D H 60 600 1000 1800 61 00 1000 1800 62 1800 1000 2000 63 2 1000 2000 64 3000 1000 2000 65 3600 1000 2000 67 00 1000 2000 Type Dimensions [mm] W D H 70 3600 1000 2100 71 4200 1000 2100 72 4800 1000 2100 73 5 1000 2100 74 6000 1000 2100 75 6600 1000 2100 76 7200 1000 2100 Type Dimensions [mm] W D H 80 3600 1 2200 81 4200 1 2200 82 4800 1 2200 83 5 1 2200 84 6000 1 2200 85 6600 1 2200 86 7200 1 2200 Type Dimensions [mm] W D H 90 4200 2000 2 91 5 2000 2 92 6000 2000 2 93 6600 2000 2 94 7200 2000 2 95 8 2000 2 H Type Dimensions [mm] W D H C20 6000 2 2 C30 9000 2 2 HC40 000 2 2700 L P 54

Static digital stabilisers Product range The static stabiliser is used when the correction speed represents the critical issue (for example, computers, laboratory equipment, measuring benches and medical instrumentation). The stabilisers are designed and built in compliance with the European Directives concerning CE marking 2006/95/EEC (Low Voltage Directive) and 2004/EEC (Electromagnetic Compatibility Directive). The stabiliser can operate with input and output different (380V/415V) from the rated (V). Such setting can be performed at the factory or at the Customer's premises according to the instructions given in the handbook. The stabiliser operates with a load variation range for each phase from 0 to 100% and is not affected by the power factor of the load. The standard cabinet is an IP21 metal enclosure with RAL7035 finish for indoor installation. The operating principle is similar to the one described for the electro-mechanical stabilisers. The difference lies in the fact that the compensation on the buck/boost primary winding is performed by an electronic board through IGBT static switches instead of the autotransformer with variable transformer ratio. The microprocessor-based system monitors the output and determines the opening/closing of the IGBT switch ensuring the best regulation. The GEMINI series is provided with a display (run by the control system microprocessor) showing output and alarm signals. The AQUARIUS series is provided with an output digital multimetre. Main standard components: Multi-tap autotransformer. Input automatic circuit breaker. Manual maintenance bypass. Automatic protection bypass (in the control board). Microprocessor-based control and command system. IGBT-based power regulation circuit. Input EMI/RFI filter. Output Class II surge arrestors. Digital display or multimetre. Accessories Isolating transformer IP54 cabinet for outdoor installation. Gemini Single-phase 4-20kVA Aquarius Three-phase 10-60kVA 55

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Static digital stabiliser Gemini single-phase 4-20kVA Standard features Voltage regulation IGBT control Selectable output 220-230-240V Frequency 50/60Hz ±5% Admitted load variation Up to 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion Forced ventilation -25/+45 C -25/+60 C 150% 2 sec. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Over protection Protections IP21 Output digital voltmeter Indoor Output class II surge arrestor Input automatic circuit breaker. Automatic bypass protection. Manual maintenance bypass. A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 56

Gemini single-phase 4-20kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Correction time [%] [kva] [V] [A] [V] [A] [%] Type [kg] Enclosure Weight Input variation range ±20%/±15% ES7-20 ±20 7 184-276 38 30 230 ES10-15 ±15 10 195-265 51 43 ES10-20 ±20 10 184-276 54 43 230 ES15-15 ±15 15 195-265 76 65 ES15-20 ±20 15 184-276 81 65 230 ES20-15 ±15 20 195-265 102 87 Input variation range ±30%/±25% ES4-30 ±30 4 161-300 25 17 230 ES5-25 ±25 5 172-288 29 22 ES5-30 ±30 5 161-300 31 22 230 ES7-25 ±25 7 172-288 40 30 ES7-30 ±30 7 161-300 44 30 230 ES10-25 ±25 10 172-288 57 43 Half-cycle 13 32 Half-cycle 13 40 Half-cycle 14 57 Half-cycle 13 32 Half-cycle 13 40 Half-cycle 14 57 57

«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Static digital stabiliser Aquarius three-phase 10-60kVA Standard features Voltage regulation Voltage stabilisation IGBT control Independent phase control Selectable output 220-230-240V (L-N) / 380--415V (L-L) Frequency 50/60Hz ±5% Admitted load variation Up to 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion Forced ventilation -25/+45 C -25/+60 C 150% 2 sec. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Over protection Protections IP21 Output digital multimetre Indoor Output class II surge arrestor Input automatic circuit breaker. Automatic bypass protection. Manual maintenance bypass. A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 58

Aquarius three-phase 10-60kVA Type Input variation range Rating Input range Maximum input current Output ±0.5% Output current Efficiency h Correction time [%] [kva] [V] [A] [V] [A] [%] Type [kg] Enclosure Weight Input variation range ±20%/±15% ET20-20 ±20 20 320-480 36 29 ET30-15 ±15 30 340-460 51 43 ET30-20 ±20 30 320-480 54 43 ET45-15 ±15 45 340-460 76 65 ET45-20 ±20 45 320-480 81 65 ET60-15 ±15 60 340-460 102 87 Input variation range ±30%/±25% ET10-30 ±30 10 280-520 20 14 ET15-25 ±25 15 300-500 29 22 ET15-30 ±30 15 280-520 31 22 ET20-25 ±25 20 300-500 39 29 ET20-30 ±30 20 280-520 41 29 ET30-25 ±25 30 300-500 57 43 Half-cycle 23 130 Half-cycle 23 170 Half-cycle 30 200 Half-cycle 23 130 Half-cycle 23 170 Half-cycle 30 200 59

60 R

«Special» stabilisers Beside designing and manufacturing customised stabilisers tailored on the Customer's requirements, ORTEA developed product series particularly thought and optimised for specific necessities and/or applications. Here below is a list summarizing said series. DLC series OPTInet series BTS series BC series AOT series OUTDOOR series F&B series Line conditioners Line optimisers Telecommunication (TLC) Broadcasting Mains filters Outdoor installations Food & Beverage, packaging and bottling industry 61

62 R

DLC series ORTEA product range is completed by a range of line conditioners based on stabilisers and provided with additional protective devices. The following sketch shows the typical line conditioners: Input automatic circuit breaker (protection against short-circuit). Delta/Star or Delta/Zig-zag input isolation transformer (complete galvanic isolation between the mains and the load and cancellation of third and triplen harmonics). Class 1 SPD surge protective device (protection against lightning). Class 2 SPD surge protective device (protection against transients). EMI/RFI filter (protection against electro-magnetic and radio-frequency noise). INPUT AUTOMATIC CIRCUIT BREAKER ISOLATING TRANSFORMER VOLTAGE STABILISER EMI/RFI FILTER OUTPUT CLASS I SPD SURGE ARRESTOR CLASS II SPD SURGE ARRESTOR Lybra Single-phase Vega/Antares + advanced protection package 0.3-135kVA Aries Three-phase Orion + advanced protection package 2-250kVA Aries plus Three-phase Orion plus + advanced protection package 30-50kVA Discovery Three-phase Sirius + advanced protection package 60-6000kVA 63

OPTInet series Electrical equipment is usually designed to withstand a range of input s rather than just the nominal. Nevertheless, supplying a device a higher than the rated one implies higher consumption and decrease of the expected life. The IEC 60038 Standard states that the nominal should be: 230V ±10% (207V-253V) for single-phase devices; V ±10% (360V-440V) for three-phase devices. However, the attempt to harmonise the nominal across Europe to the 230/V scheme has yet to be fulfilled and at the moment there is no scheduled date for a single distribution system for all the Countries member of the European Union. This means that 220/380V and 240/415V systems are still present, although the established tolerances allow for an overall 'coverage' of the different possibilities. Moreover, the legislation concerning CE marking requires for all the devices produced or marketed in Europe to be able to work over the wide range of distributed. In relation to the UK market, for example, it must be highlighted that most of the equipment imported from continental Europe are designed for working at a level lower than the supplied one. Such units are therefore forced to function with a 10 or 20 Volts higher than the one for which they were designed, which means that they consume more energy than necessary. In case of resistive loads, supplying 240V instead of 230V implies approximately 10% increase in the power consumption. Moreover, higher supplying might induce problems in magnetic components such (possibility of core saturation). Finally, other elements, such as proximity to power plants or distribution stations and supplied at high level to cover the far end of distribution lines, might affect performance of the supplied loads and energy bills. The first step towards an optimised use of energy is to have the load analysed by a qualified technician, so that further actions can be planned and the potential energy savings estimated. To summarise, the elements allowing for an estimate of the energy savings can be reduced to: Mains different from the rated : the higher the gap, the higher the energy savings Type of load: the load can be more or less sensitive to variations. Incandescent, fluorescent and discharge lamps LED lamps Asynchronous motor Inverter driven asynchronous motors Production lines Electronic devices Consumed power is in this case directly proportional to the square of the supply and the load can be defined as dependant. Using an optimiser can extend the expected life of the load by preventing the supplying from being higher than the nominal one. No advantage with these lamps due to the fact that they are supplied a constant. Low rating motors (typically under 20/25kW), widely spread at a level both domestic and industrial, are considered as dependant. If the motor is driven by an inverter (speed electronic control) then it becomes independent. Usually, dependant loads (low rating motors and heating systems) are mixed with independent loads (electronic devices). Only a careful investigation can establish the energy savings entity. A typical application is provided by the refrigerating banks used in supermarkets, made of combination of small motors directly fed by electronic units. Small equipment such as computers, office machines and telecom systems are generally fed via power supplies, which are insensitive to variations. a little sensitive to variation sensitive to variation 64

OPTInet series EXISTING SITUATION ADDITION OF A SIMPLE VOLTAGE OPTIMISER (OPTIpower autotransformer) ADDITION OF AN OPTInet 240V 220V SAVINGS OPTIMISED SAVING kwh kwh kwh A precise analysis will enable the choice of the best solution in terms of size. Sometimes, for example, the installation of optimizing units on individual loads could be the most efficient choice. OPTInet is a specially developed stabiliser that adjusts the incoming from the distributing line to a level closer to the level for which the load had been designed. OPTInet optimizes the performance of the s u p p l i e d e q u i p m e n t, t h u s a c h i e v i n g l o w e r consumption, energy savings, costs reduction and longer life expectancy. While a traditional stabiliser is designed to compensate for input variations within a certain range (for example, ±20% of the nominal ), OPTInet has been specially developed to only reduce the input still maintaining the stabilization characteristics. OPTInet is therefore equally efficient and reliable, but financially more suitable for the purpose. In the standard configuration, the output phase can be adjusted between 200V and 240V, with an input up to 15% higher than the output one. OPTInet is available in three different versions: Basic - simple design still with electronic control. Reliable performance and economical. Plus - more sophisticated control system, user-friendly panel with phase status and alarm signals, local PC connection Advanced - top of the range control system, local LCD display showing settings and operating parameters, user-friendly panel with phase status and alarm signals, local PC connection, possibility of remote monitoring. OPTInet basic Three-phase 90-260A / 65-185kVA OPTInet plus Three-phase 160-1000A / 115-720kVA OPTInet advanced Three-phase -6000A / 290-4300kVA 65

OPTInet Standard features Voltage stabilisation Selectable output OPTInet Basic OPTInet Plus OPTInet Advanced Independent phase control 220-230-240V (L-N) 380--415V (L-L) selectable from 210V to 255V (L-N) from 360V to 440V (L-L) PC selectable from 210V to 255V (L-N) from 360V to 440V (L-L) PC / Ethernet selectable Output range ±0.5% Frequency 50/60Hz ±5% Admitted load variation Fino al 100% Admitted load imbalance 100% Cooling Ambient temperature Storage temperature Natural air ventilation (aided with fans over 45 C) -25/+45 C -25/+60 C Max relative humidity 95% Admitted overload Harmonic distortion 200% 2 min. None introduced Colour RAL 7035 Protection degree Installation IP21 Indoor Natural air ventilation (air extraction over 45 C) Over protection Output class II surge arrestor Output class II surge arrestor Input class I surge arrestor Output class II surge arrestor A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 66

OPTInet series Type Nominal current* Rating Efficiency h [A] [kva] [%] [kw] [ms/v] [Type] [kg] OPTInet Basic +15% OPTInet Basic 90A 90 65 >97 1.5 16 23 200 OPTInet Basic 5A 5 90 1.3 16 31 320 OPTInet Basic 160A 160 115 2.2 16 40 390 OPTInet Basic 200A 200 145 2.8 16 41 490 OPTInet Basic 260A 260 185 3.4 16 41 580 OPTInet Plus +15% OPTInet Plus 160A 160 115 2.2 18 60 430 OPTInet Plus 200A 200 145 2.9 18 60 490 OPTInet Plus 260A 260 185 3.5 18 60 580 OPTInet Plus 300A 300 215 4.1 18 55 710 OPTInet Plus 350A 350 250 4.9 18 55 760 OPTInet Plus A 290 6.0 18 55 850 OPTInet Plus 450A 450 325 6.5 18 55 950 OPTInet Plus 500A 500 360 6.8 18 55 1000 OPTInet Plus 600A 600 430 8.2 18 55 1100 OPTInet Plus 700A 700 500 9.5 18 55 00 OPTInet Plus 800A 800 575 10.9 18 55 1300 OPTInet Plus 1000A 1000 720 13.7 18 55 1 OPTInet Advanced +15% OPTInet Advanced A 290 3.8 20 55 900 OPTInet Advanced 500A 500 360 4.8 20 55 950 OPTInet Advanced 600A 600 430 5.4 20 55 1050 OPTInet Advanced 700A 700 500 6.8 20 55 1300 OPTInet Advanced 800A 800 575 6.8 20 55 1300 OPTInet Advanced 900A 900 650 8.5 20 56 1 OPTInet Advanced 1000A 1000 720 8.5 20 56 1 OPTInet Advanced 1100A 1100 800 10.1 20 62 1700 OPTInet Advanced 50A 50 900 10.1 20 62 1700 OPTInet Advanced 1A 1 1000.8 24 63 2200 OPTInet Advanced 1500A 1500 1100.8 24 63 2200 OPTInet Advanced 1750A 1750 50 16.0 24 63 2 OPTInet Advanced 2000A 2000 1450 16.0 24 63 2 OPTInet Advanced 2500A 2500 1800 20.0 24 64 3000 OPTInet Advanced 3000A 3000 2200 25.6 24 70 0 OPTInet Advanced 0A 0 2900 30.0 24 70 4300 OPTInet Advanced 5000A 5000 3600 37.5 30 80 6000 OPTInet Advanced 6000A 6000 4300 48.0 30 80 7300 Losses (approx) Speed regulation Enclosure Weight * Current (calculated @ 415V nominal ). Other configuration available on request. 67

BTS series The acronym BTS stands for Base Transceiver Station and is used to indicate all the transmitting and receiving devices that enable the radio coverage in a telecom cell. This is definitely an application where high quality supply, regardless of the incoming fluctuation, is very often the key for ensuring efficiency and reliability, fundamental qualities to guarantee operating continuity. Disrupted service, loss of data, security failure, inaccurate information and general inconvenience are examples of possible problems caused by unstable supply. Of course, all this results in increased costs. A stabiliser is a device able to respond to changes in the level on the input line caused by sags (due to undersized distribution lines, connection of large loads to the network, ground faults, etc.) and surges (generated by disconnection of large loads, increased at the generating plant, atmospheric events, etc.) The duration of such phenomena depends on their cause and is not easily predictable. Sags are generally more common especially where the distribution is not efficient The stabiliser specifically designed for BTS sites has proved to be an efficient solution in the telecommunication field. The stabiliser is fitted with: Metallic enclosure for outdoor installation. IP54 protection degree. Manual bypass. Input and output circuit breakers. Input digital voltmeter. Output Class II surge arrestors. Optional isolating transformer. The stabilisers can be single-phase, three-phase or specifically designed for receiving a three-phase input and releasing a single-phase output. With the three-phase configuration, the regulation is performed independent on each phase and the stabiliser requires the neutral wire presence for a correct operation. If the neutral wire is not available, the addition of a D/Y isolating transformer or neutral-point reactor is required. Three-phase stabilisers can be used with three-phase loads and up to 100% unbalanced single-phase loads, even in case of asymmetric mains. The instrumentation is installed on the cabinet door. An output digital multimetre provides with information on the line downstream the stabiliser (phase and linked s, current, power factor, active power, apparent power, reactive power, etc). Minimum, maximum, internal overheating and overload on the regulator are signalled by an acoustic alarm. The stabiliser exploits a microprocessor-based control logic. Main features Power design based on the maximum input current. Regulation based on the «rms» and insensitivity to harmonics on the mains. Full functionality with load charge variable from 0 to 100%. Up to 30% harmonic content admitted on the load current. Insensitivity to the load power factor. No generation of noticeable harmonics in the output. Protections and signals Motor rotation stop due to regulation reaching the limit switches. Maximum and minimum line alarm. Ambient thermostat (set to 65 C). Automatic circuit breaker to protect the regulator. Fuses to protect the auxiliary circuits. Class II surge arrestors. 68

INPUT ISOLATING TRANSFORMER QF1 INPUT AUTOMATIC CIRCUIT BREAKER DVS VOLTAGE STABILISER QF2 OUTPUT AUTOMATIC CIRCUIT BREAKER I 0 II QS CHANGEOVER SWITCH OUTPUT (optional) CLASS II SPD SURGE ARRESTOR Standard features BTS1 BTS3 BTS3/1 Number of phases 1 3 3-1 Output 220-230-240V (L-N) 380--415V (L-L) 380--415V (L-L) INPUT 220-230-240V (L-N) OUTPUT Nominal rating from 5kVA to 80kVa Input range ±15% - ±20% - ±25% - ±30% - +15%/-25% - +15%/-35% - +15%/-45% Output range ±0.5% Frequency 50/60Hz ±5% Admitted load variation Fino al 100% Admitted load imbalance n.a. 100% n.a. Cooling Ambient temperature Storage temperature Natural air ventilation (air extraction over 45 C) -25/+45 C -25/+60 C Max relative humidity 95% Admitted overload Harmonic distortion 200% 2 min. None introduced Colour RAL 7035 Protection degree Installation Over protection IP54 Outdoor Output class II surge arrestor A P P R O V E D M A N A G I N G S Y S T E M All ORTEA stabilisers are designed and built in compliance with the 2006/95/EEC (Low Voltage) and 2004/108/EEC (Electromagnetic Compatibility) European Directives with regard to the CE marking requirements. ORTEA products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the Company applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO11:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the Company at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value. 69

BC series The acronym DVB stands for Digital Video Broadcasting and is used to indicate all the devices transmitting and receiving digital signal. The availability of high quality supply is the key for ensuring operating continuity. The BC series is specifically designed for DVB stations and consists of a digital stabiliser able to compensate for variation on the input line generated by sags or surges, completed by additional devices for the protection against transients and electric noise generated by electronic appliances. Usually, a BC stabiliser includes: Digital stabiliser. Isolating transformer. Input & output automatic circuit breakers. Input Class I surge arrestors. Output Class II surge arrestors. EMI/RFI filter. Instrumentation (voltmeter/multimetre). For outdoor installation, the unit is housed in an IP54 metallic enclosure. Small power units can be assembled in enclosures suitable for 19 rack mounting, thus advantaging practicality and ergonomics. 70

AOT series AOTs (wave absorbers) are obtained by assembling in a cabinet a combination of protective devices to deal with transients carried by the distributing lines. In order to achieve the most complete protection level, the AOT combines two complementary concepts: smoothing and filtering. The task is performed through surge arrestors, isolating transformers, detuning reactors and capacitors. AOTs must be installed upstream and in series to the equipment that needs protection in order to avoid inductive and /or capacitive effects on the lines. Usually, AOTs include: Input automatic circuit breaker. Parallel surge arrestors (redundant system). Isolating transformer. Capacitors. Detuning/blocking reactor. Output automatic circuit breaker. The operation can be divided in three phases: 1. The surge arrestors discharge to ground the direct over energy 2. The isolating transformer ensures galvanic isolation between the mains and the equipment to be protected 3. The filtering module eliminates the residual energy. 71

OUTDOOR series All ORTEA stabilisers can be assembled in c a b i n e t s s p e c i fi c a l l y d e s i g n e d f o r o u t d o o r installation. The standard outdoor cabinets are built for an IP55 protection degree and are painted with powder paint for C3 anti-corrosion class (C4 on request). On request, ORTEA is also able to provide with units destined to be installed in particularly aggressive environments (for example, AISI304 and AISI316 stainless steel cabinets). 72

F&B series Specifically designed for food & beverage, packaging and bottling industries, these stabilisers are housed in an IP54 cabinet cooled via air conditioning units. The stabiliser is therefore protected against dust or other volatile substances and liquid sprays. The configuration includes raised feet, so that normal cleaning routines can be performed underneath the stabiliser. On request, the cabinet can be in stainless steel. 73

Warranty terms 1.1 Warranty The purchased equipment is under warranty against any material or workmanship defects that might occurs within the terms indicated in the following starting from the date of purchase and for all mechanical, electrical and electronic parts. During the warranty period, the Manufacturer will repair or replace any defective parts, unless said defects are due to: improper handling, storage and/or use: wear & tear resulting from normal usage; incompetence or negligence on the Buyer s side when installing, running and maintaining the unit; interventions performed by or on behalf of the Buyer without written authorization; failure to comply with instructions given by the Manufacturer; removal, alteration or forgery of the nameplate and the data indicated thereof; and fortuitous or force majeure events such as (but not limited to) fire, earthquake, flood, riot and revolution, war, political instability, terroristic act, strike, etc.). Moreover, the provided warranty will immediately become null and void in case of: failure to comply with the payment terms; failure to carry out routine and / or extraordinary maintenance; improper use of the equipment; and external phenomena beyond the unit s scope and control. In case of failure, the Buyer shall contact the Head Office where the Manufacturer will decide whether the repair can be performed on location, or if the equipment has to be shipped to the Manufacturer's facilities or to an after-sale Service Centre authorised by the Manufacturer. If the repairing intervention can be performed at the Buyer s facility, all the expenses relevant to travelling, boarding and lodging of the Seller personnel shall be at the Buyer s charge, whilst spare parts and labour costs shall be at the Manufacturer s charge. However, the Buyer shall produce copy of the purchasing document (invoice) and report the detected anomaly prior to the intervention. If the intervention is performed at the Manufacturer's facility, the equipment shall be duly packed and shipped back at the Buyer s expense and risk. The shipment after the repairing operations shall be under the Manufacturer s responsibility. Unless otherwise agreed upon in writing, this warranty does not cover the replacement of the entire equipment under no circumstances whatsoever. Nothing shall be due to the Buyer for the time in which the equipment is left idle. The Buyer may not claim any compensations and/or reimbursements for expenses or indirect damages caused by the equipment failure. Parts provided as spare parts and/or replacements are subject to the same warranty terms. Repair or replacement of a defective part does not extend the original warranty period on the product as a whole. The competent place of jurisdiction for any disputes is in Monza (Italy). 1.2 Proper use While the unit is functioning, the operator must be protected from any risks associated with the functioning mode. The proper / correct use of the equipment allows for full exploitation of its characteristics in complete safety. For such purpose: follow the instructions in the user manual; check the integrity of equipment and components; comply with instructions and warnings provided; check status of preservation and keep maintenance on the equipment under control; check the status of cables and electrical connections; comply with the nameplate data such as (but not limited to) power, and amperage; use the equipment for the purpose intended by the Manufacturer; operate the equipment in the environmental conditions for which it was designed; cut off the power supply in case of inspection, repair and maintenance; use suitable work clothing and personal protective equipment (PPE); immediately report any malfunction (bad behaviour, suspicion of rupture, incorrect movement and noise beyond the standard level) to the department manager and switch off the equipment; comply with the recommended maintenance frequency, recording every control and comment related to the performed intervention. 1.3 Misuse / Improper use The Manufacturer defines as «misuse / improper use» of the equipment any other than what described in the previous paragraph and in addition to that: modification of the operating parameters. Should it be necessary to make any modification to the equipment, the Buyer shall contact the Manufacturer; use of unsuitable or inadequate energy sources; employment of not adequately trained/skilled personnel to run the unit; failure to comply with the maintenance instructions or maintenance incorrectly carried out; use of non-original spare parts or unsuitable ones; modification and / or tapering with the equipment safety devices; performance of control operations, maintenance, or repairs without having first disconnected the energy supply; performance of temporary repairs or remedial measures not complying with the instructions.. WARNING. The Manufacturer declines all responsibility for damage to persons or belongings due to improper use as defined above. 1.4 Warranty terms 24 months from invoice date for VEGA, ANTARES, ORION, ORION PLUS, GEMINI e AQUARIUS. 36 months from invoice date for SIRIUS. 60 months from invoice date for SIRIUS Advance. 74

www.ortea.com The belief that product quality and Customer satisfaction are the core of a modern organisation, led to the implementation of an ISO9001:2008 certified Company Managing System. T h e a c h i e v e m e n t o f t h e I S O 1 4 0 0 1 : 2 0 0 4 a n d OHSAS18001:2007 accreditation was a natural integration in order to optimise the Company s performance, showing at the same time the commitment towards environmental and safety at work issues. APPROVED MANAGING SYSTEM ISO9001 ISO11 OHSAS18001 The present document is reserved property of ORTEA SpA: it is compulsory to inform head office and ask for authorisation before proceeding with any release or reproduction. ORTEA SpA will not be held liable or responsible in any way for unauthorised copies, alterations or additions to the text or to the illustrated parts of this document. Any modification involving company logo, certification symbols, names and official data is strictly forbidden. In order to obtain better performance, ORTEA SpA reserves also the right to alter the products described in this document at any date and without prior notice. Technical data and descriptions do not therefore have any contractual value.