GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Similar documents
GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GMR - 67P 67P 09/05/2016 GMR - 067P

GQW1400V. 1MWe TWINGEN in container 20 HC

P6000s 230V 50Hz #CONN #DPP

THE COMPLETE PETROL PACKAGE

P V 50HZ #CONN #DPP

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

S V50HZ #AVR #CONN #DPP

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

MODEL GSW Deutz.

Rating Definitions and Conditions

Rating Definitions and Conditions

Model NA 2 L

Standby Amper VOLTAGE

MODEL GSW80 Deutz & 110 Perkins.

1 / Genset general description

MODEL GBW15-22 Yanmar

Model MP150 W W

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

Rating Definitions and Conditions

Standby Amper VOLTAGE

1 / Genset general description

Rating Definitions and Conditions

Rating Definitions and Conditions

GE.PK.022/020.SS+0_all

1 / Genset general description

Rental Power QSL9 series engine

DIESEL GENERATOR SET MTU 12V1600 DS660

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

19 KW / 24 KVA POWERED by

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Rental Power QSB7 series engine

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET MTU 10V1600 DS500

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage. kva kw kva kw

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

Diesel generator set QSK78 series engine

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

DIESEL GENERATOR SET DG00660D5

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

Standby Amper VOLTAGE

Diesel generator set QSL9 series engine

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V2000 DS1000

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

DIESEL GENERATOR SET MTU 16V2000 DS1100

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Transcription:

Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 562.85 Standby power LTP kw 450.28 Prime power PRP kva 509.86 Prime power PRP kw 407.89 Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

Engine Specifications Brand Model Version Exhaust emission level Engine cooling system Nr. of cylinder and disposition MTU 10V1600G80F 50 Hz Stage IIIA Water 10 V Displacement cm³ 17500 Aspiration Speed governor Turbocharged intercooled Electronic Operating Speed-Nominal rpm 1500 Prime gross power PRP kw 448 Maximum gross power LTP kw 493 Oil capacity L 60 Lube oil consumption @ PRP (max) % 0.5 Coolant capacity L 94.03 Fuel Diesel Specific fuel consumption @ 75% PRP g/kwh 190 Specific fuel consumption @ PRP g/kwh 197 Starting system Electric Starting engine capability kw 8 Electric circuit V 24 Fuel consumption @ 75% PRP L/h 76.54 Fuel consumption @ 100% PRP L/h 105.07 Engine equipment Electric starter Set of dry-type air filters with contamination indicator Fuel delivery pump Fuel main filter Fuel priming pump for initial system filling and venting Closed fuel system Lube oil circulation pump with safety valve Lube oil multi-stage filter Lube oil heat exchanger Oil filter neck and oil dipstick for measurement on non-running engine Electronic engine management system "ADEC" Front-type radiator for jacket water and charge air cooling circuit with integrated expansion tank

Alternator Specifications Brand Mecc Alte Model ECO40-1L/4 Class H IP protection 21 Poles 4 Frequency Hz 50 Frequency tolerance % 0.5 Voltage tolerance % 1 Power factor cos ϕ 0.8 Efficiency @ 75% load % 94.6 Standard AVR DER1-A Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DER 1. The digital DER 1 is a Digital controlled regulator, based on DSP (Digital Signal Processor) that combines function as Voltage Regulation and Alternator Protections and Diagnostic into a very small single board. Voltage supply: 40Vac 270Vac Maximum continuous output current: 4Adc Frequency range: 12Hz 72Hz Single phase sensing automatic recognition Average value of voltage regulation Voltage regulation range (sensing) from 75Vac to 300Vac Precision of voltage regulation: ± 1% from no-load to nominal load in static condition, with any power factor and for frequency variations ranging from -5% to +20% of the nominal value. Precision of voltage regulation: ± 0,5% in stabilized conditions (load, temperature). Transient voltage drop and overvoltage within ± 15% Voltage recovery time within ± 3% of the value set, in less than 300 msec. Underspeed protection with adjustable threshold and slope Overvoltage and undervoltage alarms Excitation overcurrent protection with delayed intervention Allarm conditions storage (type of alarm, number of events, duration of the last event, total time) Memorization of the regulator operation time Windings / Excitation system Generator stator is wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. MAUX (Standard): The MAUX MeccAlte Auxiliary Winding is a separate winding within the main stators that feeds the regulator. This winding enables to take an overload of 300% forced current (short circuit maintenance) for 20 seconds. This is ideal for motor starting requirements. PMAUX (optional): Alternator can be equipped with the optional PMAUX (Permanent Magnet Generator) which matches the performance and is capable of supporting both linear and distorted loads. Insulation / Impregnation Insulation is of class H standard. Impregnation is made with premium tropicalised epoxy resins by dipping and dripping. High voltage parts are impregnated by vacuum, so the insulation level is always very good. In the high-power models, the stator windings undergo a second insulation process. Grey protection is applied on the main and exciter stator to give enhanced protection. Reference standards Alternator manufactured according to, and complies with, the most common specification such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/CSA-C22.2 No14-95-No100-95.

Genset equipment BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH: Anti-vibration mountings properly sized Welded or Screwed support legs. (according to canopy size) PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: Filler neck Air breather (ventilation pipe) Minimum fuel level sensor MANUAL OIL DRAININ PUMP: Oil draining facilities ENGINE COMPLETE WITH: Battery Liquids (no fuel) CANOPY: Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles and internal perforated galvanized steel-sheet; Detachable panels, with screws holes protected by rubber tap. Control panel protection door provided with suitable window and lockable handle. Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. Double lifting points frame structure. SOUNDPROOF: Noise attenuation thanks to soundproofing material (rock wool) Efficient residential silencer placed inside the canopy

Dimensional data Length (L) mm 4700 Width (W) mm 1757 Height (H) mm 2430 Dry weight kg 5520 Fuel tank capacity L 636 Autonomy Running time @ 75% PRP h 8.31 Running time @ 100% PRP h 6.05 Noise level Guaranteed noise level (LWA) db(a) 105 Noise pressure level @ 7 mt db(a) 75 Installation data Total air flow m³/min 735.00 Exhaust gas flow @ PRP m³/min 75 Exhaust gas temperature @ LTP C 499 Data Current Battery capacity Ah 180 MAX current A 812.43 Circuit breaker A 800 Control panel availability AUTOMATIC CONTROL PANEL ACP MODULAR PARALLEL PANEL MPP

ACP - Automatic control panel Mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set, protected through door with lockable handle DIGITAL INSTRUMENTATION (through AC-03) Generating set voltage (3 phases) Mains voltage Generating set frequency Generating set current (3 phases) Battery voltage Power (kva - kw - kvar) Power factor Cos φ Hours-counter Engine speed r.p.m. Fuel level (%) Engine temperature (depending on model) COMMANDS AND OTHERS Four operation modes: OFF - Manual starting - Automatic starting - Automatic test Pushbutton for forcing Mains contactor or Genset contactor Push-buttons: start/stop, fault reset, up/down/page/enter selection Remote starting availability DC system disconnection switch Acoustic alarm Automatic battery charger RS232 Communication port Settable PASSWORD for protection level PROTECTIONS WITH ALARM Engine protections: low fuel level, low oil pressure, high engine temperature Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure Circuit breaker protection: III poles Earth Fault included in the control unit OTHERS PROTECTIONS Emergency stop button Panel protected through door with lockable handle OUT PUT PANEL ACP Plinth row for connection from ACP to LTS panel. Predisposed for remote control optional: RCG External Terminal Board (ETB) Standard Socket kit Optional

MPP - Modular parallel panel Mounted on the genset, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple gen-sets operating in standby or parallel modes (up to 32 gen-sets in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) Mains: voltage, Intensity, Frequency. Mains kw - kvar -Power factor Cos f. Genereting set voltage (3 phases). Generating set frequency. Generating set current (3 phases). Generating set Power (kva - kw - kvar). Generating set Power factor Cos f. Generating set kwh and kvah. Battery voltage. Hours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). COMMAND AND OTHERS Graphical display 128x64 pixels. Operation modes: OFF - AMF function - Single Parallel to mains Island application - Single Parallel to Mains AMF application - Mulitple parallel genset Island application. Pushbutton for forcing Mains Breaker/contactor or Genset Breaker/contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Multiple parallel and Power Management operation with digital load AVR sharing. Automatic synchronizing and power control (via speed goveroner or ECU) Baseload Import/Export and Peak shaving Voltage and PF control (AVR). Configurable digital I/O (12/12) and analogue inputs (3). Integrate PLC programmable functions. Event-based history (up to 500records). Selectable measurment range 120/277V and 0-1/0-5A. Remote starting and Blocking signal availability. DC system disconnection switch. Acoustic alarm. Automatic battery charger. 2xRS232/RS485/USB Comuncation ports. Setable PASSWORD for protection level. PROTECTION WITH ALARM AND SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Others: overcurrent, shortcircuit, reverse power, Earth fault OTHERS PROTECTION: Circuit breaker protection: IV poles Motorized. Emergency stop button. Panel protected through door with lochetable handle OUT PUT PANEL MPP Multi-pin connectors (in and out ) for parallel with other generators n 2 Connecting cable with 2 connectors multipin (length 10m) n 1 ETB External terminal board ETB

Supplements: Only Available when order : CONTROL PANEL SUPPLEMENT RCG - Various supplements for remote controls - available for models: TLP - Various supplements for remote signals - available for models: ADI - Adjustable Differential Intensity - available only for models: TIF - IV Poles Circuit Breaker instead of III - available for models: ACP MPP ACP MPP ACP ACP Socket kit Kit SKB or Kit SKC (for total n. 4 socket) - avaliable for model: ACP Individual CB and Earth Fault protection 400V/63A 3P+N+T CEE n 1 400V/32A 3P+N+T CEE n 1 230V/16A SCHUKO n 1 With version SKB: 400V/16A 3P+N+T CEE n 1 With version SKC: 400V/125A 3P+N+T CEE n 1 GENSET EQUIPMENT LPT - Leak Proof Tray AFP - Automatic Fuel Pump - available for models: KRT- Kit Rental for HEI gensets which includes: 3-way fuel valve, battery switch ACP MPP Extended Fuel Tank Fuel tank capacity L 4620 Length (Genset) (L) mm 4730 Width (Genset) (W) mm 1920 Height (Genset) (H) mm 2980 ENGINE SUPPLEMENTS PHS - Coolant Pre-Heating System - available for models: ACP MPP

Accessories Items available as accessory equipment LTS - LOAD TRANSFER SWITCH - Accessories ACP Load Transfer Switch panel complete with: Two layers motorized change-over switch 4pole made by means of two switch disconnectors mechanically interlocked. Automatic under-load change-over (AC22, AC23) from and to any of positions 1, 0, 2 both electrical and manual (emergency change-over), transfer function with direct transition from position 1 to position 2 and vice versa. Front display of positions 1, 0, 2 by digital display and mechanical indicator. Safety: locking by padlock preventing any electrical or manual operation, key lock for the selection of electrical or manual operation.- Quick operating time from pos. 1 to 2 and vice versa. Easy and fast electrical connections by means of terminal blocks of quick connection type. Conformity to standards: IEC 60947-1 IEC 60947-3, CEI EN 60947-1 / CEI EN 60947-3IEC 439-1, CEI EN 60439-1IEC 204-1, CEI EN 60204-1, VDE 0660 Teil 107 Signalling lamps for MAINS SUPPLY or GENSET SUPPLY. Manual selector switch for power supply manual selection: MAINS AUTO GENSET NOMINAL CURRENT & DIMENSIONS PANEL LTS (standard*) Nominal Current A 1000 Width (W) mm 1000 Height (H) mm 800 Depth (D) mm 450 * = Available electrical power more Publishing date: 30/04/14 2012 PR INDUSTRIAL s.r.l. All rights reserved Image shown may not reflect actual package. Specifications subject to change without notice ENERGY GENERATION is registered trademarks of PR INDUSTRIAL s.r.l. Other company, product or service names may be trademarks or service marks of others. RevA (06/2012).