Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

Similar documents
Indice Pag. 1. Indice

DRIVER MOS-FET UNIDIRECTIONAL AM** SERIES. Instruction Manual for use

Continental Hydraulics Installation Manual CEM-AA-A

User Guide. Mini Maestro Drive. Variable Speed Drive for Permanent-magnet DC Servo-motors. Part Number: Issue Number: 2

User Guide. Mini Maestro. Variable Speed Drive for Permanent-magnet DC Servo-motors. Part Number: Issue: 5.

Mini Maestro Drive. User Guide. Variable Speed Drive for Permanentmagnet DC Servo-motors. Part Number: Issue Number: 4

Electronic Ballast EVG 2000-T

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

BSC Series

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

5001TCP SPEED CONTROLLER

CD3000S-1PH Thyristor Unit Heater Break version

DC Variable Speed Drive Panel

Filtered PWM Speed Control for Permanent Magnet DC Motors

SAILMON SYSTEM LOAD CELL BOX MANUAL. Sailmon LoadCellBox Manual V1.0 Page 1

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

DC3N Non-Regenerative DC Drives

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

Fincor Series 2230 MKII/2240

INSTRUCTION MANUAL. Code 270R SOFT STARTERS FOR ASYNCRONOUS THREE-PHASE MOTORS. Motori, azionamenti, accessori e servizi per l'automazione

MDC Series

ENGINE GOVERNING SYSTEMS

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Electronic Controls Proportional Valve Control Power Plugs

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

ELECTRIC MACHINES EUROLAB 0.3 kw

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY

Compliance with CE Marking and UL Standard

Installation and Operating Instructions for ROBA -takt Switch Gear Type

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

TRAC-3 TENSION READOUT AND CONTROL

Description 1/8-7.5HP

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

CD3000S-1PH Thyristor Unit Analog Input version

user's manual nx frequency converters brake resistors

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

DKG-114 MANUAL AND REMOTE START UNIT

INSTRUCTIONS MANUAL COD Motori, azionamenti, accessori e servizi per l'automazione. Via Fogazzaro, 67 - CALDOGNO - VICENZA - ITALIA

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

MDC Series

5001TCP SPEED CONTROLLER

M A N U A L. Thyristor - Drive 1 Quadranten Classic P A. Stegmaier-Haupt GmbH Industrieelektronik 01/2018 V 01

Functional Symbols and Application Notes

ECONOMISER SERIES E2T USER MANUAL

Power Plugs for Proportional Valves (12 volt supply)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

ATOTH-G Series BLDC Motor Controller. User s Manual

Brushed. Brushed. Brushed Motor

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

RHINO MOTION CONTROLS

MDC Series

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

8. Filter / Autoranging Rectifier Module (FARM )

ALTIVAR 18 AC Drives. File 8805

ALTIVAR 58 AC Drives

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

FE100/FE200. Inverter

OD OD DIGITAL DISSOLVED OXYGEN CONTROLLERS

ESD-5500E Series - Speed Control Unit

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

Troubleshooting. CryoSmart 1 - CryoSmart 20

VFD Best Practices: Getting the Most from Your VFD Investment

AC drive has detected too high a Check loading

VSD Series II Variable Speed Micro Drives

ELECTRIC MACHINES EUROLAB 0.3 kw

Adjustable Torque Controls

Model 1000AR INSTALLATION AND OPERATION. Regenerative Brushless DC Motor Control INSTRUCTION MANUAL

17429X.00 SERIES MODELS:

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

PowerOhm Installation Manual for BM R Series Braking Modules

ESD5550 / 5570 Series Speed Control Units

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

PowerOhm Installation Manual for LG ATV Series Braking Modules

PM300E Voltage Regulator Instruction Manual

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

Center Winder Specification

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

MDC Series

Power Factor Improvement

SUM340 SUMMATION BOARD

Transcription:

MANUAL Micro Driver Via Ilaria Alpi N 6 - zona industriale - Lonato (BS) Tel. 030/9913491r.a. Fax. 030/9913504 http://www.re-elettronica.it E-mail : info@re-elettronica.it

Pag. 1 Index Index........pag.1 General features.....pag.2 Mechanical features Available size Electrical features pag.3 Protections Signalling Led Setting trimmer..... pag. 4 Terminal connection Lay out components Calibration resistors. pag. 5 Failure search...pag.6

Pag. 2 GENERAL FEATURES: Mechanical features: Avaiable Size: VDC VAC I nom. I peak V motor 60 V 28 44V 5A 10A 24 48V 60 V 28 44V 10A 20A 24 48V

Pag. 3 Electrical Features Switching driver with PWM technology four quadrant with high speed response. Single supply in dc. Double loop for speed and current control. FF next to one, it is not required inductance in series to the motor Analogue control signal 10V from C.N., potentiometer or other source. Switching Frequency 16khz (no sound noise) Cutting frequency switching >600 Hz (response time<16ms). Both single and differential mode speed control input. Speed Offset adjustable. Input impedence 20Kohm. Temperature range from 0 C to 40 C. Start current (I peack) double of noninal current for one second. Speed feedback from tacho dynamo or from armature with R*I compensation. MOSFET failure Missing of internal supply voltage. Short circuit of the motor. Overtemperature Minimum voltage. Overvoltage. Protections: The intervention of protection is signalled by RED LED (fault), and by the opening of the transistor in open collector configuration between terminal 7 and 0V of the driver. Signalling LED : GREEN LED Driver is supplied and works correctly. YELLOW LED Driver is in limited current condition ( the load requires a greater current than nominal current ) RED LED Driver is in fault for the intervention of one of the aforementioned protections.

Pag. 4 Setting Trimmers: Ramp.: to adjust the acceleration and deceleration time. V.max.: to adjust the V max of the motor. K V: to adjust gain of speed loop (improving the response of the motor to load variations) Offset: to bring the speed to 0 when indicated by the reference. Terminal connections: 1. - Tacho-dinamo input 2. - Tacho-dinamo input 3. - Input for current limitation 4. - Enabling, the driver is enabled if a voltage between 8 and 24 V is present on terminal 4 5. Negative differential input for speed reference 6. - Positive differential input for speed reference 7. Output driver OK (open collector transistor 0,1A, normally 0V) 8. - Common zero V 9. - Positive supply +10V (5mA MAX) 10.- Negative supply 10V (5mA MAX) Layout components:

Pag. 5

6 Pag. Tacho dynamo feedback: Calibration resistors: (see page 4 for layout components) JP6 JP7 Dynamo Votage 10K 10K 5 20V 47K 47K 11 45V 150K 150K 30 120V JUMPERS I JP2,JP4 e JP5 MUST BE OPEN. ARMATURE FEEDBACK : JP2 JP4 JP5 Motor voltage See note 1 Jumper Jumper 12 35V See note 1 47K 47K 20 75V See note 1 82K 82K 30 100V JUMPERS JP6 AND JP7 MUST BE OPEN. NOTE 1: JP2 sets R*I compensation, it must be chosen in a way that the motor speed remains constant as the load changes. Example of current setting: JP1 JP3 Current (In Ip) 100K 100K 1.25 2.5 A 47K 47K 2.5 5 A 22K 22K 5 10 A 27K 27K 8 16 A 22K 22K 10 20 A NOTE 2: pay attention to the output current when adjusting JP1 and JP3, a current too high can damage the driver

6 Pag. Size of external components Supply: 3-phase supply Single-phase supply 3-phase net Transformer Single-phase net Transformer Fuses F3-ph C Fuses Fs-ph C The output voltage from the transformer is 0.9*(motor nominal V). In any case between: 28-44 Vac for MicroDriver60 driver type Power of the transformer Pt = 1.5 * (motor nominal V) * (motor nominal I) Levelling capacitors 100V voltage for MicroDriver60 driver type Capacity in F C = (motor power) / Vdc * 1000 If, during braking phase, overvoltage protection turns on, use higher and higher capacity capacitors until the driver works correctly. Fuses Fs-ph (Ampere) = 1.7 * Pt Single-phase supply Vdc F3-ph (Ampere) = Pt Vdc 3-phase supply Attention: these sizing indications are for general use, after evaluating specific applications it is possible to reduce the power of the transformer and the capacity of capacitors.

6 Pag. FAILURE SEARCH: FAILURE PROBABLY CAUSE REMEDY The motor does not break RED FAULT ON, LED OK OFF The supply capacitor is not enough to absorb the braking energy Increase the supply capacitor The motor escapes LED OK OFF Supply is OK LED FAULT ON Tacho-dynamo connection interrupt or reversed Failure on the tachodynamo. External short circuit Internal short circuit Supply voltage exceed the nominal voltage Termal protection for excessive heating of the driver. Check connection from dynamo to driver Check the efficiency of the dynamo. Remove the short circuit Replace the driver Reduce the supply voltage Turn off supply voltage, wait for 15 minutes and eventually install a fan.

Pag. 9 General rules to eliminate network disturbs and EMI (CE certification) All the electrical equipments that switch inductive loads generate disturbs that can spread electromagnetically (EMI) or via conduction (along the electrical network, on inductive couplings of wires). We supply some rules to eliminate these disturbs. ATTENTION!!! The driver you bought has been tested for electromagnetical compatibility and CE certification, anyways to guarantee the electromagnetical compatibility of the whole equipment you have to follow these instructions. Net filters utilization To prevent the generated disturbs from propagating on the electrical networks and from disturbing other connected devices is necessary to use net filters. To choose a net filter you must pay attention to the type of network it will be connected (single phase or three phase), to the power absorbed by the load and to the power of the filter (single cell or double cell). It is important to connect the filter near to the driver (not beyond 30 cm of wire), and its metallic cover must be grounded. In this manual there is written next to each driver size the adequate net filter. If needed net filters can be bought from us. Electrical network Net filter Driver M Shielded cables use Connection cables are antennas that receive and transmit disturbs; you must use shielded cables both for low-power links (control links) and high-power links (links with the motor). By doing this you will reduce the noise and the emitted electro-magnetic interference. Attention! The shield must be grounded only on one end of the cable, you can link it to the mass of the motor which will be grounded as well. Adequate cables layout The correct wiring of the panel is fundamental for a good functioning of the entire system and to solve problems of electromagnetical compatibility. Here there are the main rules for the array of the cables. Use shielded cable both for control and power links.

Pag. 10 If possible keep a distance between control and power cables. Put the cables into wireways or metal pipes. Avoid tangles and crossings, where this is not possible make only 90 crossings. Grounding Grounding is fundamental to reduce disturbs; follow this general rules: Ground the mass of the driver (0V signal) linking it to all the shields of the control cables. Ground all the metallic shells of the system (cover and radiator of the driver, motor shell, etc.) trying to use wide surfaces of contact. For the groundings use low-impedance cable even for high frequencies. Remove layers of paint or oxide from the surfaces of contact. Insert in the usual maintenance program the control of the low-impedance of ground links. Electric panel example Supply wireway Motor connections wireway High power system Signals Ground bar Transformers PLC, PC Driver Drivers Num. Contr. Contactors Net filter Signals wireway Power round bar Signals ground bar Not painted zync plated metal sheet shield