TECHNICAL INSTRUCTIONS DGP

Similar documents
TECHNICAL INSTRUCTIONS DGPT2

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

P17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»

Replacement Tubes for Gillian Gas Detection Pumps

HYPRA Prisinter 16/32/63 A

RDN4 - RDN8 Differential pressure switch

RPPN3 - RPPN7 Industrial pressure switch

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

Buchholz Relays Series RR - RRF - GQ

APOVAC R Vacuum Systems

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

TEST REPORT: CHM12-01-LSM

Colorimetric Gas Detector Tube System US Dollar Price List

Filtration efficiency: 99% or more HEPO2element

This convenient system is made entirely of inert parts: glass, Baseline drift

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Small on price, big on boot

Inductive Proximity Sensor

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

MM PISTON PUMP

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Grommet TET. Cable glands. Basic Data. Application. Press the grommet into the hole.

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

Ducting & Ventilation Components

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

Transformer Protection Relay MCHD

Filtration efficiency: 99% or more

EZ-View. Flow Meters ISO CERTIFIED 9001

Liquid filled Thermometers

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

FR PVC COATED RAINWEAR

Inductive Proximity Sensor

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Metallic Systems TYPE SPTC

Pump kits. We deliver values.

&HQWUH1DWLRQDO G ([SHUWLVH5pVHDX[

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

Inductive Proximity Sensor

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Pump Kits. More than just pumps

Hose and Fitting Edition

Marina Cabinets LIMOGES Cedex Telephone: Fax:

Halogen Free, Flame-retardant Polyether based TPU

Flow Meter Terminal Boxes

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

Information Sheet Polyethylene Tank Assemblies

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Rod thermostat with micro switch

Type MR 783 Magnetic level switch

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

NPA-CP Pendant Control Station

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Operating Instruction for Flowmonitor. Model: DF-WM

MM PISTON PUMP

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

16/32/63A - IP44 plugs, mobile sockets, socket inlets and appliance inlets

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

Operating instructions Binary level sensor LMT /00 06/2011

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

Buchholz Relay MBP Gas and Oil Actuated Relay

Rated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Plastic tube variable area flowmeter for liquids and gases

Iron Gate Air Pump System Manual

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

OPERATING INSTRUCTIONS MESURES. Portable sludge level measuring instrument, battery operated MES. MUDLine TGS

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

MF /MS Series

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

VE4000 & VE5000 SERIES

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

High Temperature Marker Tag

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Surface mounting, flush mounting, and DIN track mounting

NCPR DB INOX / NCPRI DB INOX

High pressure industrial ball valves

Pressure transmitter for industrial applications Type MBS 4510

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM

LTX RF LEVEL SENSOR. Instruction Manual

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/

EN WORKMASTER HAZMAX BOOTS. Certification

Transcription:

20 rue de la pommeraie, 78310 Coignières FRANCE Tel: +33-1-361-232 Fax: +33-1-361-8919 info@automation2000.com www.a utomation2000.com TECHNICAL INSTRUCTIONS DGP DGP 1

1 INSTALLATION (COMPLETELY FILLED HERMETIC TRANSFORMERS) 1.1 Preamble The following installation procedure is given for information only. Automation 2000 cannot be held responsible for its execution. 1.2 Installation precautions Before installing the DGP, make sure that: The transformer is not powered. The transformer dielectric is at ambient temperature (approx. 20 C). The dielectric level inside the transformer is slightly below the transformer tank cover. The transformer opening on which the DGP will be installed is opened. 1.3 Installation procedure Remove the drain tap and the level indicator float from the DGP. Fit the FPM seal (supplied) in the DGP attachment flange throat. Mount the DGP on the transformer opening designed for that purpose. Attach the fixing hooks (supplied) on the fixing bolts (3 at 120 or at 90 ) according to the tightening precautions (see page ). The fixing bolts must be located on a circle with a 97 mm diameter (±2 mm). Fill the DGP with transformer dielectric until its level reaches the DGP highest point. Put back the level indicator float into place and close the DGP with its drain tap. Drain tap Fixing hook Level indicator float DGP 2

2 INSTALLATION (BREATHING TRANSFORMERS WITH CONSERVATOR) 2.1 Preamble The following installation procedure is given for information only. Automation 2000 cannot be held responsible for its execution. 2.2 Installation precautions Before installing the DGP-IB, make sure that: The transformer is not powered. The transformer dielectric is at ambient temperature (approx. 20 C). The transformer conservator is empty. The dielectric level inside the transformer is slightly below the transformer tank cover. The transformer opening on which the DGP-IB will be installed is opened. 2.3 Installation procedure Fit the FPM seal (supplied) in the DGP-IB attachment flange throat. Mount the DGP-IB on the transformer opening designed for that purpose. Attach the fixing hooks (supplied) on the fixing bolts (3 at 120 or at 90 ) according to the tightening precautions (see page ). The fixing bolts must be located on a circle with a 97 mm diameter (±2 mm). Connect the DGP-IB to the conservator through its IB insert with a flexible tube equipped with both a 3/8 female threaded end and a rotary fitting. Fill the conservator up to its normal level. Slowly open the DGP-IB sampling tap until the transformer dielectric level reaches the DGP-IB highest point and close it. Sampling tap Fixing hook Flexible tube IB insert DGP 3

TIGHTENING PRECAUTIONS When you tighten the HM8 bolts on the DGP fixing hooks, make sure that: The tighten coupling is not higher than 3 m.kg (30 N.m). The DGP attachment flange DOES NOT TOUCH the transformer cover (the FPM seal should stay visible approx. 1 or 2 mm). The DGP fixing hooks are tightened one after the other, clockwise in two steps. During the first step, use a loose tighten coupling on all fixing hooks. During the second step, use a tighten coupling not higher than 3 m.kg (30 N.m). LEAKPROOFNESS PRECAUTIONS The DGP drain tap s leakproofness is insured by a FPM seal positioned at the root of the screw thread undercut. NEVER USE Teflon tape (or similar tape) to insure the DGP drain tap s leakproofness through its screw thread. DGP

3 ELECTRICAL OPERATION 3.1 Preamble All DGP monitoring functions come with change-over contacts (a Normally Opened contact, a Normally Closed contact and a Common point). In the following diagrams, the contacts are shown unpowered (dead), meaning not under the influence of any defect for their respective monitoring functions. 3.2 Operating diagram 3.2.1 Gas discharge Gas discharge is usually due to an electrical defect in the transformer active part, creating an electrical arc not strong enough to cause an instantaneous pressure increase. NORMAL LEVEL Reed contact(s) Gas accumulation tank NO NC NO NC Triggering float C C Indicator float Reed 3 2 1 3 2 1 Terminal block G2 (as an option) G1 When the gas volume inside the gas accumulation tank reaches a certain value (depending on the dielectric density), the Reed contact changes position. Dielectric density < 1 Volume < 10 cm 3 Dielectric density = 1 Volume = 10 cm 3 (±5 cm 3 ) Dielectric density > 1 Volume > 10 cm 3 DGP 5

3.2.2 Excessive pressure Excessive pressure is usually due to an internal short-circuit, creating an electrical arc strong enough to indirectly cause an instantaneous pressure increase. Excessive pressure set-point is always defined by the transformer manufacturer. NORMAL PRESSURE Pressure switch s contact(s) Pressure switch NO NC NO NC C C Setting system 6 5 6 5 Terminal block P2 (as an option) When the tank pressure reaches the set-point value (±0.01 bar), the pressure switch s contact changes position. P1 DGP 6

TESTS.1 Precautions Before carrying out the tests, make sure: That the transformer is not powered. To carefully check the wiring system. That the electric interlocking system is powered so that the loops can be tested up to the final element (e.g. LED for alarm function, actuators for trigger function)..2 Gas discharge Element concerned: Reed contact Moving a magnet (minimum Ø 22 mm, thickness 10 mm) under the Reed housing (or on the side) will change the contact s position. Check that the loop is operating correctly..3 Excessive pressure Element concerned: Pressure switch type 1 Press the test button located on the left side of the pressure switch. The contact changes position. Check that the loop is operating correctly, then release the test button. Element concerned: Pressure switch type 2 Turn the setting knob clockwise to bring the set-point to zero. The contact changes position. Check that the loop is operating correctly, then reset the set-point at the value indicated on the yellow identification plate. Reed housing Magnet TYPE 1 Test button TYPE 2 Setting knob DGP 7

5 CLEANING PRECAUTIONS 5.1 Basic precautions DGP plastic body is made of a transparent polyamide specifically treated against ultraviolet with an improved outdoor weathering behaviour. When the DGP plastic body needs to be cleaned, always make sure that the composition of the cleaning product (or leak detection product) does not contain any chemical listed on page 9. Diesel fuel and kerosene are excellent cleaning agents. If you use a cleaning product containing one of these chemicals, cracks caused by the stress release inside the polyamide will appear on the DGP plastic body. These stress-cracks will cause leaks and make the DGP inoperative until its plastic body has been replaced. CRACKS 5.2 Loss of transparency In contaminated atmosphere, successive layers of deposit can alter the DGP plastic body transparency, and even totally occult the visibility of both the dielectric level and the floats. In that case, the best way to recover partial visibility is: To use a cleaning product containing no chemical listed on page 9. To use an ultrafine plastic or painting polishing compound used for car body. DGP 8

5.3 Chemical and solvent prohibited with DGP plastic body A Acetone Acrylonitrile Allyl alcohol Ammonium sulfide, 0% Amyl alcohol Aniline B Benzaldehyde Benzoic acid* Bromine, liquid 1,3-butanediol 1,-butanediol 2,3-butanediol n-butyl alcohol t-butyl alcohol Butylene glycol C Chloroform Chlorosulfuric acid Crotonaldehyde Cyclohexane D 1,2-dichloroethane 1,2-dichloroethylene Difluoromonochloromethane Dimethylformamide 1,-dioxane E Ethyl alcohol Ethylamine, 33% Ethylene diamine Ethylene glycol F Fluorodichloromethane Formic acid, concentrated Furfuralcohol G Gasoline (5% methanol) Glacial acetic acid H Hydrazine hydrate, 80% Hydrochloric acid, concentrated I Isoamyl alcohol Isopropanol M Methylene chloride Methyl ethyl ketone N Nitric acid, 2% Nitric acid, 10% Nitric acid, 30% P Potassium chlorate* n-propanol Propylene glycol S Sulfuric acid, concentrated T Tartaric acid* * Saturated solution in water at 23 C DGP 9

6 TECHNICAL DATA 6.1 Metal housing - Housing and cover in AISI 30 with 2 screws that can be sealed by lead Ratings: IP56, IK07 - Wiring output through M25 cable gland with anchor (two positions possible) Tighten capacity: 13-18 mm - Wiring through terminal block with a 6 pitch Tighten capacity: mm² (6 or 12 terminals) - 5 mm diameter earthing screw inside the housing - 6 mm diameter earthing screw at the outside base of the housing - Insulation: 500 VDC, 20 MΩ between terminals and earth - Dielectric rigidity: 2,000 VAC, 1 minute between terminals and earth - Fire hazard: the stuffing glands, terminal blocks, wires, etc. are made of selfextinguishing halogen free material. The housing contains fire. 6.2 Plastic body - Plastic body in polyamide with ultraviolet stabilizer Ratings: IP56, IK07 6.3 Reed contact - 1 Reed contact (2 Reed contacts as an option) - Change-over contacts 6. Pressure switch - Metallic bellows with adjustable counterspring pressure switch with 1 microcontact (2 microcontacts as an option) - Change-over contacts - Adjustable set-point that can be sealed by lead - Setting scale: 0 500 mbar (0-700 mbar on request) - Measure accuracy: ±5 mbar - Response time: < 10 milliseconds 6.5 Fitting - Fitting at the base of the housing through a flange in composite with a thermowell to be installed on a 60 mm diameter opening (FPM seal and fixing hooks supplied). Flange diameter: 85 mm Thermowell: 10 mm (length), 27-2 mm (diameter from top to bottom end) - The flange and the thermowell do not conduct electricity. DGP 10

6.6 Operating conditions - Ambient temperature: 0 C to 65 C - Dielectric temperature: 10 C 6.7 Breaking capacity 6.8 Standard compliance The DGP conforms to the following Standards: NF EN 50216-1 NF EN 50216-3 NF EN 60529 NF EN 6039-1 NF EN 60950 NF C17-300 NF C52-107 RESISTIVE LOAD - L/R < 0 ms Function 2 VDC 8 VDC 110 VDC 220 VDC 250 VAC 50/60 Hz Cos φ 0.5 Gas discharge 1 A 1 A 0.5 A 0.25 A 1 A Excessive pressure 2 A 3 A 0.5 A 0.25 A 5 A DGP 11

7 SPATIAL REQUIREMENT 97 65 2 297 207 231 58 5 2 ø 85 10 66 20 93 18 3 Flange axis 52 DGP 12

8 OPTIONS 2G: 2 synchronous gas contacts The DGP is equipped with two Reed contacts, whose triggering thresholds are identical. The Reed contacts characteristics are identical to the Reed contact equipping the Standard DGP. Conforming to NF EN 50216:3 Standard, the Reed contacts change position when the gas inside the transparent body reaches a volume between 100 and 200 cm 3. 2GD: 2 gas contacts with an offset The DGP is equipped with two Reed contacts, whose triggering thresholds are offset by 0 cm 3 approximately. Conforming to NF EN 50216:3 Standard, the Reed contacts change position when the gas inside the transparent body reaches a volume between 100 and 200 cm 3. 2P: 2 synchronous pressure contacts The DGP is equipped with a pressure switch with 2 microcontacts, whose triggering thresholds are identical. The triggering threshold is defined by the customer. 2PD: 2 pressure contacts with an offset The DGP is equipped with a pressure switch with 2 microcontacts, whose triggering thresholds are offset. Defined at the time of the order, this offset (10 to 100 mbar) cannot be modified by the customer afterwards. The value indicated on the pressure switch s setting system is the lowest triggering threshold (P1). IB: connection for conservator The flange of this DGP is equipped with two 3/8 male inserts for conservator connection (or connection to any other accessories). DGP 13

PA: marine cable gland The DGP is equipped with a marine cable gland insuring the cable anchorage, the continuity of armour and the water tightness of both the internal and external cable coating from the connecting cable. SB : flangeless The DGP is equipped with a 1 gas female threaded base, enabling it to be installed on a 1 gas male threaded socket located on top of the transformer cover. SO: drain tap with popoff relief valve The drain tap equipping the DGP includes a popoff relief valve. Its calibration is defined by the customer and adjusted by Automation 2000. X: industrial and marine atmosphere The DGP is equipped with a metal housing and cover made of AISI 316L stainless steel, a drain tap made of brass with chemical nickel coating, and fixing hooks made of AISI 316L stainless steel. The DGP equipped with this option is IP67 classified. DGP 1

9 ACCESSORIES AND SPARE PARTS 1 Reed contact Spare part for Standard DGP. 2 synchronous Reed contacts Spare part for DGP with option 2G. 2 Reed contacts with an offset Spare part for DGP with option 2GD. 3/8 flexible tube for conservator fitting This accessory consists of a corrugated hose made of AISI 316L stainless steel with a braiding made of AISI 30L stainless steel. Its standard version is equipped with a 3/8 female threaded end and a rotary fitting made of AISI 316L stainless steel on both extremities. The flexible tube s length is defined at the time of the order. Antimagnetic shield This accessory has been designed to prevent spurious releases of the DGP s Reed contact in highly magnetic environments. Made of AISI 30 ferromagnetic stainless steel, it is supplied with its fixing screw. Drain tap Spare part made of nickel plated brass. DGP 15

Drain tap with popoff relief valve Spare part made of nickel plated brass. Its calibration is defined by the customer and adjusted by Automation 2000. Fixing hooks Spare parts made of steel or AISI 316L stainless steel. Flat seal for drain tap Spare part made of FPM for drain tap with or without popoff relief valve. Flat seal for flange Spare part made of FPM. DGP 16