Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Similar documents
DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on right side

DX³ 4-pole RCBO 6000 A/10 ka

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DX³ RCBO 6000 A Phase + Neutral, neutral right side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DX³ RCCBs - ID 4P up to 100 A

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

TX³ RCCBs 2P up to 100 A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

(1,5 modules per pole)

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

Btdin RCBO 6000A up to 63A (2P)

up to 63 A (1 module per pole)

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

R.C.B.O. SP / 1 module

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Cat N 3. OVERALL DIMENSIONS

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

New DX 3 High rating & breaking capacity

DPX moulded case circuit breakers

Industrial Contactors CTX 3 3P 185A - 800A

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

cor Long Run Experience

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

3 - Protection components Motor circuit-breakers

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

COMPLETE SOLUTIONS FOR POWER PROTECTION

MCBs and RCDs LR TM 6000

Low Voltage A GE Power Controls Company. General catalogue

Vistop TM isolating switches 63 to 160A

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

NB1 Miniature Circuit Breaker

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Breaking and protection devices

Modular contactors and relays

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Protection components

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

DPX earth leakage DPX 3 -I earth leakage

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

AF40... AF96 3-pole contactors Technical data

Power protection solutions

ic60a circuit breakers (curve C)

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable)

Electronic overload relays EF205 and EF370

DPX 1600 Electronic release

For Info: Phone: Fax:

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Electronic overload relay EF65, EF96 and EF146

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

The effective choice The benefits of a product with the highest quality standards

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

Thermal overload relay TF65 and TF96

Practical and completely safe

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

and other modular devices for low voltage installation

Essential equipment for all your requirements

Manual Motor Starters. Meta-MEC

DRX 125 Circuit breaker (not adjustable)

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE


ZS4-SF1 Screw Clamp Terminal Block

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Thermal-magnetic Miniature Circuit Breaker 4230-T...

K50H004UP cam changeover switch - 4-pole A - screw mounting

DSE201 Compact design with enhanced protection

Thermal overload relay TF140DU and TF140DU-V1000

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Miniature Circuit Breaker

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

DPX Electronic + earth leakage

BETA Switching Switches and Light Indicators

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Control Circuit Protection

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

SD Series Non-Fused Load Switches

DPX 630 Electronic release

Electronic circuit breaker EBU10-T


020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Viking 3 - Screw connection Disconnect terminal blocks

Transcription:

Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance and approvals... 14 7. Curves... 15 8. Auxiliaries and accessories... 20 9. Safety... 20 1. DESCRIPTION - USE Residual Current Circuit Breaker with Overload (RCBO) with positive contact indication for control, protection against short-circuits and overloads, and isolation of electrical circuits, protecting people from direct and indirect contact and protecting installations from insulation faults. 2. RANGE (continued) Breaking capacity:. Icn = 4500 A in accordance with standard EN/IEC 61009-1. Icu = 6 ka in accordance with standard EN/IEC 60947-2 3. OVERALL DIMENSIONS Symbol: Technology:. Limiting device. The Neutral contact closes before and opens after the Phase contact. The phase pole provides protection and isolation for the phase circuit. The neutral pole provides isolation for the neutral circuit 2. RANGE Polarity:. 2 poles including 1 protected pole and 1 neutral pole Width:. 2 modules (2 x 17.8 mm) Rated current In:. 10 / 16 / 20 / 25 / 32 A Magnetic tripping curve:. C curve (between 5 In and 10 In) 4. PREPARATION - CONNECTION Mounting:. On symmetrical rail EN 60715 or DIN 35 rail Operating positions: Vertical Horizontal Upside down flat Type:. AC (sinusoidal differential alternating current) Sensitivity:. 30 ma in AC type Rated voltage and frequency:. 230 V~, 50 Hz with standard tolerances. 240 V ~, 50 Hz with standard tolerances Trip indication on residual current fault:. Yellow indicator on the front Power supply:. Either from the top or the bottom 1 / 20

RCBO 2p 4. PREPARATION - CONNECTION (continued) Connection:. Terminals protected against direct finger contact IP20 when wired device. Cage terminals, with release and captive screws. Terminals fitted with shutters preventing a cable being placed under the terminal, with the terminal partly open or closed. Alignment and spacing of the terminals permitting shutters with the other products via pin and fork supply busbars. Terminal depth: 14 mm. Terminal capacity: 60 mm². Screw head: mixed head, slotted head and Philips / Pozidriv no. 2. Tightening torques: - Minimum / Maximum: 1.2 Nm / 3.5 Nm - Recommended: 2.5 Nm Conductor type:. Copper cable at the top and bottom of the product. Cable cross-section 5. GENERAL CHARACTERISTICS Neutral earthing system:. IT,TT, TN Marking on the front side:. By permanent ink pad printing Marking on the upper panel:. By permanent ink pad printing Rigid cable Without ferrule 1 x 0.75 to 50 mm² 2 x 0.75 to 16 mm² With ferrule - Flexible cable 1 x 0.75 to 35 mm² 2 x 0.75 to 16 mm² 1 x 0.75 mm² to 25 mm². Prong busbar, alone or with a 10 mm² flexible wire (without ferrule) or a connection terminal in the same terminal. Required tools:. For the terminals: - 5.5 mm / 6.5 mm blade screwdriver recommended - Pozidriv n 2 / Philips N 2 screwdriver recommended. For the latching: - 5.5 mm blade screwdriver recommended / 6 mm maximum - Pozidriv n 2 / Philips N 2 screwdriver recommended Manual actuation of the RCBO:. Ergonomic 2-position handle - O-OFF : device open - I-ON : device closed Contact status display:. By marking of the handle - O-OFF in white on a green background = contacts open - I-ON in white on a red background = contacts closed. The terminals upstream and downstream of the neutral pole are marked with an "N" moulded close to the screw heads. Maximum operating voltage:. U = 250 V Test operating voltages: I n 30 ma min. U 110 V~ max. U 264 V~ Breaking capacity:. With a single-phase network (with alternating current 50 Hz) Standard Breaking capacity Voltage between poles Breaking capacity Locking:. Possible in the open or closed positions with padlock support (Cat. No. F80BL) and Ø5 mm padlock or Ø6 mm padlock.. Possible in the open or closed positions Labelling:. Circuit identification by way of a label inserted in the label holder situated on the front of the product. EN/IEC 61009-1 EN/IEC 60947-2 Ics Icn Ics Icn Icu Ics 127 V 230 V 230 V 6 ka 6 ka 4.5 ka 4.5 ka 6 ka 75% Icu 2 / 20

RCBO 2p Breaking capacity on one single pole (phase pole):. In accordance with I IT EN60947-2 Appendix H (double fault in IT system): 3 ka at 400 V~ and 3 ka at 230 V~. In accordance with Icn1 EN60898-1: 4.5 ka at 230 V~ and 10 ka at 127V~ Residual breaking capacity:. In accordance with standard EN/IEC 61009-1 section 9.12.11.4d (I m: short-circuit to earth) I m = 3 ka Insulation voltage:. Ui = 250 V in accordance with standard EN/IEC 61009-1 Isolation distance:. The distance between the contacts is greater than 5.5 mm with the handle in the open position.. The RCBO is suitable for isolation in accordance with standard EN/IEC 61009-1. Degree of pollution:. 2 in accordance with standard EN/IEC 61009-1. Dielectric strength:. 2,000 V Rated impulse withstand voltage. Uimp = 4 KV (wave 1.2/50 s) Protection from false tripping:. 8/20 µs wave resistance : 250 A for AC type. 0.5 µs/100 khz damped recurring wave resistance : 200 A for AC Degree or class of protection:. Terminals protected against direct contact, class of protection against solid objects and liquids (wired device): IP20 in accordance with standards IEC 529 / EN 60529 and NF 20-010. Front side protected against direct contact: IP40. Class II in relation to metallic conductive parts. Class of protection against mechanical impacts IK02 in accordance with standard EN 62262. Plastic materials:. Polyamide and P.B.T. Enclosure heat and fire resistance:. Resistance to glow wire tests at 960 C, in accordance with standard EN/IEC 61009-1. Classification V2, in accordance with standard UL94 Higher heating potential:. The heat potential is assessed at: 2.1MJ Closing and opening force via the handle:. 4 N on opening. 10 N on closing Electrical endurance:. Conpliant with standard EN/IEC 61009-1. Tested with 10,000 operations with load (at In x Cos 0.9). Tested with 2,000 residual current trip operations using the Test button or the fault current Sinusoidal vibration resistance (in accordance with IEC 68.2.6):. Axes: x y z. Frequency: 10 to 55 Hz. Acceleration: 3g (1g = 9.81 m.s - ²) Resistance to tremors:. In accordance with standard NF EN 61009-1 Ambient temperature:. Operation:. For the AC type from - 25 C to + 70 C.Storage: from - 40 to +70 DC operation:. No Frequency:. Operation at 400Hz: No Packaged volume and quantity: Volume (dm 3 ) Packaging For all ratings 0.4 Per 1 Derating of RCBOs function of the number of devices placed side by side: When several RCBOs are installed side by side and operate simultaneously, the heat dissipation of one pole is limited. This results in an increased operating temperature for RCBOs which may cause false tripping. Applying the following coefficients to the operating currents is recommended. Number of RCBOs side by side Coefficient 2-3 0.9 4 5 0.8 6-9 0.7 10 0.6 These values are provided by recommendation IEC 60439-1 and the standards NF C 63421 and EN 60439-1. In order to avoid having to use these coefficients there must be good ventilation and the devices must be kept apart using the spacing elements Cat. No. F80/05D (0.5 module). Mechanical endurance:. Compliant with standard EN/IEC 61009-1. Tested with 20,000 operations with no load 3 / 20

RCBO 2p Impact of height: 2000 m 3,000 m 4,000 m 5,000 m Dielectric strength 2,000 V 1,750 V 1,500 V 1,250 V Maximum operating voltage 230 V 230 V 230 V 230 V Derating at 30 C none none none none Derating of RCBOs in the event of use with fluorescent tubes: Electronic or ferromagnetic ballasts provide a high inrush current for a very short time. These currents are liable to cause tripping of the RCBOs.The maximum number of ballasts per RCBO stated by the lamp and ballast manufacturers in their catalogues should be taken into account during installation. Product weight: Catalogue Number Description Weight (kg) GC8813AC10 C10 AC type 30 ma 0.24 GC8813AC16 C16 AC type 30 ma 0.25 GC8813AC20 C20 AC type 30 ma 0.24 GC8813AC25 C25 AC type 30 ma 0.25 GC8813AC32 C32 AC type 30 ma 0.26 Dissipated power (W):. C curve RCBOs in In/Un RATED CURRENT Power (W) Phase pole Power (W) Neutral pole 10 A 16 A 20 A 25 A 32 A 1.9 W 3.3 W 4.9 W 3.7 W 5.7 W 0.5 W 1.5 W 2.3 W 2.6 W 4.2 W Derating of RCBOs depending on the ambient temperature:. The nominal characteristics of a circuit breaker are modified depending on the ambient temperature which prevails in the cabinet or enclosure where the RCBO is located.. Reference temperature: 30 C in accordance with standard EN/IEC 61009-1. In (A) - 25-10 0 10 20 30 40 50 60 70 10 12.5 12 11.5 11 10.5 10 9.7 9.4 9.1 8.8 16 20 19.2 18.4 17.6 16.8 16 15.52 15.04 14.56 14.08 20 25 24 23 22 21 20 19.4 18.8 18.2 17.6 25 31.25 30 28.75 27.5 26.25 25 24.25 23.5 22.75 22 32 40 38.4 36.8 35.2 33.6 32 31.04 30.08 29.12 28.16 4 / 20

RCBO 2p Association and coordination of an RCBO with a protective device located upstream: This association allows a device's breaking capacity to be increased by combining it with another protective device placed upstream. This combination makes it possible to use a downstream device with a breaking capacity which is lower than the maximum prospective short-circuit current at its installation point. Association and coordination with upstream fuses:. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system Upstream fuse gg and am types Downstream RCBO Ph+N 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 160 A 10 A 50 ka 50 ka 50 ka 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 50 ka 50 ka 50 ka 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A - 50 ka 50 ka 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A - - 50 ka 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 16 ka 32 A - - - 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 16 ka BTDIN 60 6000 A B, C and D curves Downstream RCBO Ph+N 1/2 mod / P 20 A 25 A 32 A 40 A 32 A 40 A 50 A 63 A 10 A 6 ka 6 ka 6 ka 6 ka 10 ka 10 ka 10 ka 10 ka 16 A 6 ka 6 ka 6 ka 6 ka 10 ka 10 ka 10 ka 10 ka 20 A - 6 ka 6 ka 6 ka 10 ka 10 ka 10 ka 10 ka 25 A - - 6 ka 6 ka 10 ka 10 ka 10 ka 10 ka 32 A - - - 6 ka - 10 ka 10 ka 10 ka BTDIN 100 10kA B, C and D curves Downstream RCBO Ph+N 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A - 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 5 / 20

RCBO 2p Association and coordination with upstream MCBs:. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system BTDIN 160 16kA B, C and D curves Downstream RCBO Ph+N 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A 32 ka 32 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 32 ka 32 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 32 ka 32 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A - 32 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A - - 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka BTDIN 250 25kA B, C and D curves Downstream RCBO Ph+N 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 50 ka 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A - 50 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A - - 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka BTDIN 500 50kA B, C and D curves Downstream RCBO Ph+N 25 A 32 A 40 A 50 A 63 A 10 A 50 ka 50 ka 25 ka 25 ka 25 ka 16 A 50 ka 50 ka 25 ka 25 ka 25 ka 20 A 50 ka 50 ka 25 ka 25 ka 25 ka 25 A - 50 ka 25 ka 25 ka 25 ka 32 A - - 25 ka 25 ka 25 ka 6 / 20

RCBO 2p Association and coordination with upstream Moulded Case Circuit Breakers (MCCBs):. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system M1 160E MT 16 ka Downstream RCBO Ph+N 16 A 25 A 40 A 63 A 80 A 100 A 125 A 160 A 10 A 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 16 A - 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 20 A - 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 25 A - - 22 ka 22 ka 22 ka 22 ka 22 ka 22 ka 32 A - - 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka M1 160B MT 25 ka / M1 160F MT 36 ka / M1 160N MT 50 ka Downstream RCBO Ph+N 16 A 25 A 40 A 63 A 80 A 100 A 125 A 160 A 10 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 16 A - 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 20 A - 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 25 A - - 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A - - 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka ME160 B / ME160 N / ME160 H 50 ka Downstream MCB 25 A 40 A 63 A 100 A 160 A 10 A 30 ka 30 ka 30 ka 30 ka 30 ka 16 A 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 A - 20 ka 20 ka 20 ka 20 ka 32 A - 10 ka 10 ka 10 ka 10 ka 7 / 20

RCBO 2p Association and coordination with upstream Moulded Case Circuit Breakers (MCCBs):. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system ME250 B / ME250 N / ME250 H 50 ka Downstream RCBO Ph+N 100 A 160 A 250 A 10 A 30 ka 30 ka 30 ka 16 A 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 A 20 ka 20 ka 20 ka 32 A 10 ka 10 ka 10 ka M2 250B / M2 250F / M2 250N / M2 250H 70 ka (thermal-magnetic) M2 250B / M2 250F / M2 250N / M2 250H 70 ka (electronic) Downstream RCBO Ph+N 100 A 160 A 200 A 250 A 40 A 100 A 160 A 250 A 10 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 16 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 20 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 25 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka MP2 250F 36 ka MP2 250H 70 ka Downstream MCB 100 A 160 A 200 A 250 A 6 A 30 ka 30 ka 30 ka 30 ka 10 A 30 ka 30 ka 30 ka 30 ka 16 A 30 ka 30 ka 30 ka 30 ka 20 A 30 ka 30 ka 30 ka 30 ka 25 A 25 ka 25 ka 25 ka 25 ka 32 A 16 ka 16 ka 16 ka 16 ka 40 A 16 ka 16 ka 16 ka 16 ka 8 / 20

RCBO 2p Association and coordination with upstream Moulded Case Circuit Breakers (MCCBs):. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system MA 160/250 36 ka / MH 160/250 70 ka / ML 250 100 ka thermal-magnetic MA 160/250E 36 ka MH 160/250E 70 ka / ML 250E 100 ka electronic Downstream RCBO Ph+N 25 A 40 A 63 A 100 A 160 A 250 A 40 A 100 A 160 A 250 A 10 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 16 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 20 A 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 30 ka 25 A - 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A - 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka MA 400/630MT 36 ka / MH 400/630MT 70 ka ML 400/630MT 100 ka thermal-magnetic MA 400/630E 36 ka / MH 400/630E 70 ka ML 400/630E 100 ka electronic Downstream RCBO Ph+N 250 A 320 A 400 A 500 A 630 A 160 A 250 A 400 A 630 A 10 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka M4 36kA / M4 50kA / M4 70kA / M4 100kA thermal-magnetic & electronic MP4 36kA / MP4 70kA thermal-magnetic MP4 36kA / MP4 70kA electronic Downstream RCBO Ph+N 250 A 320 A 400 A 500 A 630 A 400 A 500 A 630 A 320 A 400 A 6 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 10 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 40 A 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 16 ka 9 / 20

RCBO 2p Association and coordination with upstream Moulded Case Circuit Breakers (MCCBs):. Three-phase network (+N) 230/400 V or 240/415 V in accordance with standard EN/IEC 60947-2. TT neutral earthing or TNS system MA 630/800/1250 50kA MH 630/800/1250 70kA ML 630/800/1250 100kA MA 630/800/1250ES 50kA MH 630/800/1250ES 70kA ML 630/800/1250ES 100kA Downstream RCBO Ph+N 500 A to 1,250 A 630 A to 1,600 A 10 A 25 ka 25 ka 16 A 25 ka 25 ka 20 A 25 ka 25 ka 25 A 25 ka 25 ka 32 A 10 ka 10 ka M5 36kA / 50kA / 70kA / 100kA thermal-magnetic & electronic M5 36kA / 50kA / 70kA / 100kA electronic MP5 36kA MP5 70kA Downstream RCBO Ph+N 500 A 630 A 800 A 1000 A 1250 A 1250 A 1600 A 800 A 1000 A 6 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 10 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 16 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 20 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 A 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 25 ka 32 A 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 40 A 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka 10 ka Selectivity between two levels of protection. The downstream RCBO must always have a magnetic threshold and a rated current lower than those of the upstream protection.. Selectivity or Discrimination is said to be total (T) if there is discrimination up to the value of breaking capacity (in accordance standard with EN/IEC 60947-2) of the downstream RCBO. Discrimination with upstream fuses:. Discrimination limit with a voltage of 230 V ~ (Values in A) Upstream fuse cartridge gg cartridge Downstream RCBO Ph+N 32 A 40 A 50 A 63 A 80 A 100 A 125 A 160 A 10 A - 1600 2200 3200 3600 T T T 16 A - 1400 1800 2600 3000 T T T 20 A - 1200 1500 2200 2500 T T T 25 A - - 1300 2000 2200 4100 T T 32 A - - 1200 1700 1900 3500 T T. T = Total discrimination 10 / 20

RCBO 2p Discrimination with upstream modular MCBs:. Discrimination limit with a voltage of 230 V ~ (Values in A) Upstream fuse cartridge am cartridge Downstream RCBO Ph+N 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 160 A 10 A - 1100 1700 2500 T T T T T 16 A - 1000 1400 2100 4000 T T T T 20 A - - 1300 1800 3400 T T T T 25 A - - 1100 1600 3000 T T T T 32 A - - - 1300 2400 3800 T T T BTDIN60/100/160 B curve Downstream RCBO Ph+N 10 A 13 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A - - - 80 100 128 160 200 252 3000 T T 16 A - - - - - 128 160 200 252 2000 3600 T 20 A - - - - - - 160 200 252 1600 3000 4000 25 A - - - - - - - 200 252 1300 2400 3300 32 A - - - - - - - - 252 1000 1800 2700 BTDIN45/60/100/160 C curve Downstream RCBO Ph+N 10 A 13 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A - 98 120 150 187 240 300 375 472 3000 T* T* 16 A - - - 150 187 240 300 375 472 2000 3600* T* 20 A - - - - 187 240 300 375 472 1600 3000 4000* 25 A - - - - - 240 300 375 472 1300 2400 3300* 32 A - - - - - - 300 375 472 1000 1800 2700. T = Total discrimination. *: If the discrimination value stated in the table is greater than the breaking capacity of the upstream RCBO then the breaking capacity of the upstream device must be taken as the discrimination value (the discrimination value may not exceed the breaking capacity of the upstream device). 11 / 20

RCBO 2p Discrimination with upstream modular MCBs:. Discrimination limit with a voltage of 230 V ~ (Values in A) BTDIN60/100/160 D & K curve Downstream RCBO Ph+N 10 A 13 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A - - 192 240 300 384 480 600 756 3000 T T 16 A - - - 240 300 384 480 600 756 2000 3600 T 20 A - - - - 300 384 480 600 756 1600 3000 4000 25 A - - - - - 384 480 600 756 1300 2400 3300 32 A - - - - - - 480 600 756 1100 1450 2700 BTDIN250 B curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A - - 80 100 500 700 1000 1800 3000 T T 16 A - - - - 300 500 700 1300 2000 3600 T 20 A - - - - - 400 500 1000 1600 3000 4000 25 A - - - - - - 500 800 1300 2400 3300 32 A - - - - - - 500 600 1000 1800 2700 BTDIN250 C curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 10 A - 120 150 187 500 700 1000 1800 3000 T T 16 A - - 150 187 300 500 700 1300 2000 3600 T 20 A - - - 187 300 400 500 1000 1600 3000 4000 25 A - - - - 240 400 500 800 1300 2400 3300 32 A - - - - - 300 500 600 1000 1800 2700. T = Total discrimination 12 / 20

RCBO 2p Discrimination with upstream modular MCBs:. Discrimination limit with a voltage of 230 V ~ (Values in A) BTDIN250 D curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 10 A - 192 240 300 500 700 1000 1800 16 A - - 240 300 384 600 700 1300 20 A - - - 300 384 600 600 1000 25 A - - - - 384 600 600 800 32 A - - - - - 600 600 756 BTDIN500 B curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 10 A - - 150 210 500 700 1000 1800 16 A - - - - 300 500 700 1300 20 A - - - - - 400 500 1000 25 A - - - - - - 500 800 32 A - - - - - - 500 600 BTDIN500 C curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 10 A - 120 150 210 500 700 1000 1800 3000 16 A - - 150 187 300 500 700 1300 2000 20 A - - - 187 300 400 500 1000 1600 25 A - - - - 240 400 500 800 1300 32 A - - - - - 300 500 600 1000. T = Total discrimination 13 / 20

RCBO 2p Discrimination with upstream modular MCBs:. Discrimination limit with a voltage of 230 V ~ (Values in A) BTDIN500 D curve Downstream RCBO Ph+N 10 A 16 A 20 A 25 A 32 A 40 A 50 A 63 A 10 A - 192 240 300 500 700 1000 1800 16 A - - 240 300 384 500 700 1300 20 A - - - 300 384 480 600 1000 25 A - - - - 384 480 600 800 32 A - - - - - 480 600 756 Downstream RCBO Ph+N M1/ME/M2//MA/MH/ML/M4/M5/MP all models all ratings T. T = Total discrimination 6. COMPLIANCE AND APPROVALS In accordance with standard:. EN/IEC 61009-1 Usage in special conditions:. Category C compliant (testing temperature range from -25 C to +70 C, resistant to salt spray) in accordance with the classification defined in Appendix Q of standard IEC/EN 60947-1 Respect for the environment Compliance with European Union Directives:. Compliance with Directive 2002/95/EC of 27/01/03 known as "RoHS" which provides for a restriction on the use of dangerous substances such as lead, mercury, cadmium, hexavalent chromium and polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) brominated flame retardants from 1 st July 2006. Compliance with the Directive 91/338/EEC of 18/06/91 and decree 94-647 of 27/07/04 Plastic materials:. Halogen free plastic materials.. Labelling of parts compliant with ISO 11469 and ISO 1043. Packaging:. Design and manufacture of packaging compliant with decree 98-638 of 20/07/98 and Directive 94/62/EC Approvals obtained:. Italy: IMQ 14 / 20

t (sec) RCBO 2p 7. CURVES Thermal-magnetic tripping range typical of C curve RCBOs: In < 63A In < 63A In > 32A In < 32A x In Standard limits Thermal tripping at ambient temperature = 30 In = RCBO rated current 15 / 20

RCBO 2p 7. CURVES (continued) Average thermal-magnetic tripping curves range typical of C curve RCBOs: 16 / 20

RCBO 2p 7. CURVES (continued) Current limiting curves:. C curve RCBOs from 10 A to 32 A lcc = Prospective short-circuit symmetrical current (rms value in ka) lp = Maximum peak value (in ka) 1 = Short-circuit rms currents (max. peak) 2 = Unlimited peak currents (max.), corresponding to power factors shown above (0.15 to 0.9) NB: For 3A rating, the limited values are less than 1kA 17 / 20

RCBO 2p 7. CURVES (continued) Thermal stress limiting curves:. C curve RCBOs (230V/50Hz) lcc = Prospective short-circuit symmetrical current (rms value in A) l 2 t = Limited thermal stress (in A s) 2 NB: -The 3A rating limits to values less than 3,000 A s 2 18 / 20

RCBO 2p 7. CURVES (continued) Tripping current curves:. Tripping time curve depending on the value of the fault current: AC TYPE 19 / 20

RCBO 2p 8. AUXILIARIES AND ACCESSORIES Wiring accessories:. Supply busbar: Pin and Fork busbar (See Btcino catalogue) Sealable screw cover (Cat. No. F80CV1) Signalling auxiliaries:. Auxiliary contact (0.5 module, Cat. No. F80CA05). Auxiliary contact that can be changed into fault signalling contact (0.5 module, Cat. No. F80RC05). Auxiliary contact + fault signalling contact that can be changed into 2 auxiliary contacts (1 module, Cat. No. F80CR) Control auxiliaries:. Shunt trip (1 module, Cat. No. F80ST1/F80ST2). Autonomous shunt trip release (1 module, Cat. No. F80SV1/F80SV2). Stand-alone release for N/C push-button (1.5 module, Cat. No. F80SVE2).Pop auxiliary (Cat. No. F80SVP) Motor-driven control modules:. Motor-driven control module (1 module, Cat. No. F80MC24/F80CM230). Motor-driven control module with integrated automatic reset. (2 modules, Cat. Nos. F80MR24/F80MR230) STOP&GO automatic resetting modules:. STOP&GO automatic resetting module (2 modules, Cat. No. F80SG). STOP&GO automatic resetting module with auto-test (2 modules, Cat. Nos. F80SGB) Possible combinations of auxiliaries and RCBOs:. The auxiliaries are installed to the left of the RCBOs. Maximum number of auxiliaries = 3. Maximum number of 1 module signalling auxiliaries = 2. Maximum number of control auxiliaries = 1. The control auxiliary must mandatorily be placed to the left of the signalling auxiliaries where the auxiliaries from these 2 families are connected to the same RCBO Sealing:. Possible in the open or closed positions Locking options:. Via Ø 5 mm padlock or Ø 6 mm padlock and padlock support (Cat. No. F80BL) 9. SAFETY: For your safety your electrical installation is equipped with residual current protection which must be tested periodically. In the absence of any national regulations on the time period required for this, Legrand recommends that this test be carried out every month: press the " T " test button, the device should trip. Please call an electrician immediately if this does not happen as the safety level of your installation has been reduced. The presence of residual current protection does not remove the need to observe all the precautions associated with using electrical energy. 20 / 20