TSS Single-Duct VAV Terminals

Similar documents
SDL Single-Duct, Low-Height, VAV Terminals

Dual Duct Variable Air Volume Terminal (Model TDS)

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDR Single-Duct VAV Terminals

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

FS Fan-Coil Units Hi-Rise, Vertical

engineering guide TCS Series Fan-Powered, VAV Terminals

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS

Variable Air Volume Distribution Units CII, September 1 st, Home

catalog CFR Series Fan-Powered, VAV Terminals

HOW TO SPECIFY SDV UNITS

Variable Air Volume Dampers

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

catalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

FN Fan-Coil Units High-Performance, Horizontal

catalog VFR Parallel Flow, Fan-Powered, VAV Terminals

catalog VFL Parallel Fan-Powered, Low-Height, VAV Terminals

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

SINGLE DUCT AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

University of Delaware

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Complete HVAC Capability

VAHU Vertical Air Handling Unit

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Variable Air Volume (VAV) Pressure Independent Control

Submittal. Front View Side View

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

MAH. Modular Air Handling Unit

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

SINGLE DUCT VAV TERMINALS MODELS TSS & TSL TSS TSL. New Release Form NOM1 (808) INSTALLATION, OPERATION & MAINTENANCE

LMHS BASIC UNIT NO CONTROLS

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Laboratory Room Single Duct Supply Air Terminal

CCS Zone/Bypass Damper Assembly

I Fan Powered Terminal Unit

FAN POWERED TERMINAL UNITS

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

RAH Engineering Guide

SINGLE DUCT AIR TERMINAL UNITS

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Technical information

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

Electric Furnace KF/KFS Series

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

WAC Air Curtains Technical Guide

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Energy Recovery Laboratory Exhaust

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Direct Gas-Fired Heating

FDCLP2 Constant Volume Series Flow, Low Profile


YCCS Zone/Bypass Damper Assembly

Introduction to Johnson Controls Dampers

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

YCCS Zone/Bypass Damper Assembly

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Energy Recovery Laboratory Exhaust

IAQ. ROUND DUCT RETROFIT Model ARR

FH Fan-Coil Units Low-Profile, Horizontal

FDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

Laboratory Room Single Duct Supply Air Terminal

Climas y Proyectos Leyco, S.A. de C.V.

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

Transcription:

TSS Single-Duct VAV Terminals

Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening ribs adds strength and rigidity Galvanized-steel casing withstands 125-hour, saltspray test per ASTM B-117 Product label includes tagging, airflow, and electrical information Electrical devices installed within a NEMA 1 enclosure, with single-pointpower connection Patented FlowStar airflow sensor (Patent #5,481,925) Slip-and-drive discharge collar for quick field installation Insulation edge covered by metal no raw edges of insulation exposed to airstream Solid-composite damper shaft prevents condensation and breakage s with electronic controls listed with cetl for safety compliance Self-lubricating bearing to reduce friction and air leakage Optional Construction 1/2" thick fiberglass insulation complying with UL 181, NFPA 90A, and ASTM C1071 Low-leakage damper incorporates closed-cellfoam gasket Mechanically fastened insulation for added security Factory-control options: Analog Electronic DDC Electronic Pneumatic For more information, see corresponding Control Selection Guides Scrim-reinforced, foilfaced insulation meeting ASTM C1136 for mold, mildew and humidity resistance or 1/2" thick elastomeric, closed-cell-foam insulation Double-wall construction (not shown) Mounting brackets (not shown) to accept all threaded hanging rods or wire hangers Low-temperature construction for use in thermal-storage applications, includes: Thermally-isolated, primary-air inlet Composite damper shaft

TSS VAV Terminals: Quiet performance with single-duct simplicity Owners TSS terminals offer the typical benefits provided by single-duct units, while performing at extremely low sound levels. This is critical in today s buildings where occupants are placing more emphasis on indoor acoustics. In addition to quiet and accurate temperature control, the building owner will benefit from lower operating costs. The highly amplified, velocity-pressure signal from the FlowStar inlet sensor allows precise airflow control at low air velocities. The FlowStar sensor s airfoil shape provides minimal pressure drop across the terminal. This allows the central fan to run at a lower pressure and with less brake horsepower, while maintaining occupant comfort. The TSS terminal is manufactured and assembled with a multi-point, center-averaging, airflow sensor, which provides a signal to the controller enabling it to quietly and precisely measure airflow. Superior flow measuring allows control at lower minimum cubic-feet-per-minute (CFM) values, which reduces energy costs and sound levels. ordered with or without a Direct Digital Controller (DDC), which can operate as a stand-alone unit, on a Johnson Controls BACnet, N2, or LON trunk. Contractors Physical installation is simple with low-profile, compact design and standard metal hanging straps. And control-installation time is minimized with the availability of factory-mounted and calibrated controls. Controls are located on the outside of the unit casing for easy access by maintenance personnel. A standard, single-point, main-power connection is provided with all electronic controls and electrical compo nents located on the same side of the casing, for quick access, adjustment, and troubleshooting. The FlowStar sensor ensures accurate airflow measurement, regardless of the field-installation conditions. A calibration label and wiring diagram is located on the terminal for quick reference during start-up. Designers TSS terminals provide variable-air-volume (VAV) control beyond the typical single-duct box. The compact cabinet design and quiet operation give the system designer the option to place units directly above occupied spaces. It is not necessary to locate the unit in the crowded space above a hall or corridor. This reduces lengthy and expensive discharge-duct runs. The TSS terminal provides the ultimate in airflow control with the patented FlowStar airflow sensor. No other sensor in the industry can match the FlowStar s ability to quietly and precisely measure airflow. The FlowStar sensor ensures accurate control, even when space constraints do not permit long, straight, inletduct runs to the terminal. All metal components are fabricated from galvanized steel. Unlike most manufacturers terminals, the TSS is capable of withstanding a 125-hour, salt-spray test without showing any evidence of red rust. For added flexibility, model TSS terminals with electric heat are invertible. They may be installed with the control enclosure on the left or right, except when position-sensitive control options are required (e.g. mercury contactors). Model TSS terminals are available in ten unit sizes to handle airflow capacities between 45 and 8000 CFM. s can be VMA Series Controller (left) and LN Series Controller (right) Bundled with the TSS terminal is a digital controller from the VAV Modular Assembly (VMA) Series or the LN Series. Each model in the VMA 1400 or 1600 Series and the LN Series combines a controller, pressure sensor, and actuator housed in one pre-assembled unit. TSS terminals require no periodic maintenance and provide trouble-free operation. Model TSS terminals with electronic controls and/or electric heat are listed with ETL as an assembly, and bear the ETL label. TSS terminals and accessories are wired in compliance with all applicable NEC requirements and tested in accordance with ARI Standard 880.

Model TSS W H L A I X Y 4 10" [254] 10" [254] 11" [279] 10-1/2" [267] 3-7/8" [98] 8-3/4" [222] 8-3/4" [222] 5 10" [254] 10" [254] 11" [279] 10-1/2" [267] 4-7/8" [124] 8-3/4" [222] 8-3/4" [222] 6 10" [254] 10" [254] 11" [279] 6-1/2" [165] 5-7/8" [149] 8-3/4" [222] 8-3/4" [222] 8 12" [305] 10" [254] 11" [279] 6-1/2" [165] 7-7/8" [200] 10-3/4" [273] 8-3/4" [222] 10 14" [356] 12-1/2" [318] 13" [330] 6-1/2" [165] 9-7/8" [251] 12-3/4" [324] 11-1/4" [286] 12 16" [406] 15" [381] 13" [330] 6-1/2" [165] 11-7/8" [302] 14-3/4" [375] 13-3/4" [349] 14 20" [508] 17-1/2" [445] 17-1/2" [445] 6-1/2" [165] 18-3/4" [476] 16-1/4" [413] TOP VIEW 16 24" [610] 17-1/2" [445] 17-1/2" [445] 6-1/2" [165] 15-7/8" [403] 22-3/4" [578] 16-1/4" [413] 19 30" [762] 17-1/2" [445] 11" [279] 8" [203] 22 34" [864] 17-1/2" [445] 11" [279] 8" [203] 15-7/8" [403] 28-3/4" [730] 16-1/4" [413] 32-3/4" [832] 16-1/4" [413] RIGHT SIDE END VIEW Model TSS-WC (Hot-Water Coil) W H L A I 4 10" [254] 10" [254] 15-1/2" [394] 10-1/2" [267] 3-7/8" [98] 5 10" [254] 10" [254] 15-1/2" [394] 10-1/2" [267] 4-7/8" [124] 6 10" [254] 10" [254] 15-1/2" [394] 6-1/2" [165] 5-7/8" [149] 8 12" [305] 10" [254] 15-1/2" [394] 6-1/2" [165] 7-7/8" [200] 10 14" [356] 12-1/2" [318] 17-1/2" [445] 6-1/2" [165] 9-7/8" [251] 12 16" [406] 15" [381] 17-1/2" [445] 6-1/2" [165] 11-7/8" [302] 14 20" [508] 17-1/2" [445] 21-1/2" [546] 6-1/2" [165] TOP VIEW 16 24" [610] 17-1/2" [445] 21-1/2" [546] 6-1/2" [165] 15-7/8" [403] 19 30" [762] 17-1/2" [445] 15-1/2" [394] 8" [203] 22 34" [864] 17-1/2" [445] 15-1/2" [394] 8" [203] 15-7/8" [403] RIGHT SIDE END VIEW NOTES: 1. All dimensions are in inches [mm] with a tolerance of ±1/8" [3mm]. 2. s 19 and 22 have rectangular inlet collar. NOTE: Drawings are not to scale and are not for installation purposes. Contact your Johnson Controls representative for more information. All data and dimensions are subject to change without notice.

Model TSS-EH (Electric Heat) W H L I X Y A 4 10" [254] 10" [254] 41" [1041] 3-7/8" [98] 8-3/4" [222] 8-3/4" [222] 10-1/2" [267] 5 10" [254] 10" [254] 41" [1041] 4-7/8" [124] 8-3/4" [222] 8-3/4" [222] 10-1/2" [267] 6 10" [254] 10" [254] 41" [1041] 5-7/8" [149] 8-3/4" [222] 8-3/4" [222] 6-1/2" [165] 8 12" [305] 10" [254] 41" [1041] 7-7/8" [200] 10-3/4" [273] 8-3/4" [222] 6-1/2" [165] 10 14" [356] 12-1/2" [318] 41" [1041] 9-7/8" [251] 12-3/4" [324] 11-1/4" [286] 6-1/2" [165] 12 16" [406] 15" [381] 41" [1041] 11-7/8" [302] 14-3/4" [375] 13-3/4" [349] 6-1/2" [165] 14 20" [508] 17-1/2" [445] 41" [1041] 18-3/4" [476] 16-1/4" [413] 6-1/2" [165] 16 24" [610] 17-1/2" [445] 41" [1041] 15-7/8" [403] 22-3/4" [578] 16-1/4" [413] 6-1/2" [165] 19 30" [762] 17-1/2" [445] 44-1/2" [1130] 28-3/4" [730] 16-1/4" [413] 1-1/2" [38] 22 34" [864] 17-1/2" [445] 44-1/2" [1130] 15-7/8" [403 32-3/4" [832] 16-1/4" [413] 1-1/2" [38] Model TSS-SA (Sound Attenuator) W H A I X Y 4 10" [254] 10" [254] 10-1/2" [267] 3-7/8" [98] 8-3/4" [222] 8-3/4" [222] 5 10" [254] 10" [254] 10-1/2" [267] 4-7/8" [124] 8-3/4" [222] 8-3/4" [222] 6 10" [254] 10" [254] 6-1/2" [165] 5-7/8" [149] 8-3/4" [222] 8-3/4" [222] 8 12" [305] 10" [254] 6-1/2" [165] 7-7/8" [200] 10-3/4" [273] 8-3/4" [222] 10 14" [356] 12-1/2" [318] 6-1/2" [165] 9-7/8" [251] 12-3/4" [324] 11-1/4" [286] 12 16" [406] 15" [381] 6-1/2" [165] 11-7/8" [302] 14-3/4" [375] 13-3/4" [349] 14 20" [508] 17-1/2" [445] 6-1/2" [165] 18-3/4" [476] 16-1/4" [413] 16 24" [610] 17-1/2" [445] 6-1/2" [165] 15-7/8" [403] 22-3/4" [578] 16-1/4" [413] 19* 30" [762] 17-1/2" [445] 8" [203] 22* 34" [864] 17-1/2" [445] 8" [203] 15-7/8" [403] 28-3/4" [730] 16-1/4" [413] 32-3/4" [832] 16-1/4" [413] NOTE: Drawings are not to scale and are not for installation purposes. Contact your Johnson Controls representative for more information. All data and dimensions are subject to change without notice.

TSS Terminal Features Standard Features: Construction ARI Standard 880-certified and labeled 22-gauge, galvanized-steel casing and valve 1/2" thick, fiberglass insulation, mechanically fastened for added security Hot-Water Coils ARI Standard 410-certified and labeled 1, 2, 3, 4-row coils Tested at a minimum of 350 psig under water Mechanically expanded copper tubes leak tested to 350 psig air pressure Male sweat-type water connections Primary Air Valve Embossed rigidity rings Low-thermal-conductance damper shaft with position indicator Mechanical stops for open and closed position Multi-point, center-averaging, airflow sensor Balancing tees Plenum-rated sensor tubing Electrical Components cetl listed for safety compliance with UL 1996 National Electrical Manufacturers Association (NEMA) Type 1 wiring enclosure Electric Heat cetl listed as an assembly for safety compliance Integral, electric-heat assembly Automatic-reset primary and back-up secondary thermal limits Single-point-power connection Hinged, electrical-enclosure door Fusing per NEC Airflow switch Ni-chrome elements Wiring diagram Optional Features: Construction 20-gauge, galvanized-steel construction 3/4" or 1" fiberglass insulation Scrim-reinforced, foil-faced insulation meeting American Society for Testing and Materials (ASTM) C1136 for mold, mildew, and humidity resistance 1/2" elastomeric, closed-cell-foam insulation Double-wall construction with 22-gauge liner Mounting brackets to accept all threaded hanging rods or wire hangers Low-temperature construction for use in thermal-storage applications, including a thermally-isolated, primary-air inlet and a composite damper shaft Hot-Water Coils Low-pressure steam coils Multi-circuit coils for reduced water-pressure drop Opposite-hand water connections Bottom and top access plates for cleaning Electrical Components Toggle-disconnect switch Primary and secondary transformer fusing Electric Heat Proportional, solid-state relay (SSR) heater control Mercury contactors Disconnect (toggle or door-interlocking) Pneumatic-electric (PE) switches Manual-reset secondary limit Controls Factory-provided controls include: - Direct-digital controls (DDC) for BACnet, N2, or LON networks - Pneumatic controls - Analog electronic controls Consignment DDC controls (factory-mount and wire controls provided by others) Printed on recycled paper. PUBL-5513 (908) 2008 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.johnsoncontrols.com