Water when you need it!

Similar documents
AVK product programme. Expect A taste of AVK

AVK FIRE PROTECTION FIRE DOESN T COMPROMISE NEITHER SHOULD YOU

EXPECT TOP QUALITY VALVES AND HYDRANTS

Valves and accessories for gas

AVK UL LISTED AND FM APPROVED PRODUCT RANGE FIRE PROTECTION SOLUTIONS


OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS

September 2012 / M&H C502 / Model 129

Data Sheet Issue A

High quality valves for wastewater treatment

Invicta fire protection solutions. EXPECT High quality valve and hydrant solutions. Site Solutions, Valves & Penstocks

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

Mueller Super Centurion 250 Fire Hydrant

Water Supply and Sewerage Approved Products Manual - February 2006

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

BS 5163 Resilient Wedge Gate Valve

FIRE PROTECTION PRODUCTS

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

AA V K U K LT L TD. AV K Va l v e s & A c c e s s o r i e s f o r S e w a g e Tr e a t m e n t

ADMIRAL HYDRANT. clowvalve.com

Swing Check Valves - Series 41

AVK WATER SUPPLY WE DELIVER PURE QUALITY JUST LIKE YOU

According to AWWA-standard

Valves Range RVRX - Resilient Seated Gate Valve PN16 Flange

Cast Iron Valves. Product Information. It s all at Albion

with the specific application. Always read and understand the installation

Approved Branded Traceable Fire Protection & Waterworks Valves

Materials : Cast iron or Stainless steel

WATER AND WASTE WATER SOLUTIONS

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

OPTIMAL VALVE SOLUTIONS PRODUCT PROGRAM

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability

EXPECT RELIABILITY AVK RESILIENT SEATED GATE VALVES

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

HAWLE-specification water

AVK SAUDI VALVES MANUFACTURING COMPANY

MADE OF STAINLESS... Certificate 3.1

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

QUALITY YOU CAN RELY ON AS CUSTOMERS RELY ON YOURS

RESILIENT SEATED GATE VALVE FAF 6200

APPENDIX: TECHNICAL INFORMATION

AVK UK GROSS PRICE LIST 2017

MADE OF STAINLESS... Certificate 3.1

Valves. BS Standard JINAN MEIDE CASTING CO., LTD.

Water Distribution Solutions

VAG NOVA 284 Standpost Hydrant. Technical details. Product features

Water Distribution Solutions

Sentinel 250 Fire Hydrant

MUELLER Super Centurion fire hydrants

Valve Selection. 1. Function and service considerations

Butterfly valves. Introduction. Made of ductile cast iron

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS

BV BAKIO Soft Sealing Gate Valve

TEL: Version: KW2

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

2-6 FIRE HYDRANT---(MODEL ½ & 5 ¼

AVK WATER SUPPLY WE DELIVER PURE QUALITY JUST LIKE YOU

1. Valves shall conform to the latest version of AWWA Standard C-509 covering Resilient Seated gate Valves for Water Supply Service.

ISO RESILIENT WEDGE GATE VALVE. Engineering Creative Solutions for Fluid Systems Since 1901

General information Gate valves

Ref ALL POSITIONS CAST IRON CHECK VALVE PN16. Model/Ref:

ND = Double Door, SEAT NBR ES = Center Guided Silent Check / EPDM NS = Center Guided Silent Check / NBR. Butterfly Valves, Seat in body.

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body. Certificate 3.1

OPTIMAL VALVE SOLUTIONS PRODUCT PROGRAM

KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

Materials : Ductile iron EN GJS body, EPDM seat

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS

AVK TOTAL CONTROL INSIDE BUILDINGS GENERAL VALVES FOR BUILDING

*the installation defects and wear defects are not covered by the guarantee

Cast-Iron Valves G101 DI BUTTERFLY VALVE LEVER... 2 G401 CI GLOBE VALVE CL G403 CI GLOBE VALVE PN G103 DI BUTTERFLY VALVE GEAR...

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

British Standard Underground Hydrant Range

CV-SFS4-PN16 SERIES SLIENT CHECK VALVE, GLOBE TYPE FEATURES SPECIFICATIONS PRODUCT IDENTIFICATION SYSTEM PRODUCT DATA

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

Materials : Ductile iron EN GJS body, EPDM seat

Series 1500TD Bell Restraint Harness for Ductile Iron & C900 PVC Pipe Split Serrated Restraint Rings on Both Sides of the Bell

Materials : Cast iron or stainless steel body

BI-DIRECTIONAL KNIFE GATE VALVES XD-PRE SERIES WITH D/A PNEUMATIC ACTUATOR

Size : Ends : Min Temperature : Max Temperature : MADE OF STAINLESS... MADE OF STAINLESS...

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body. Certificate 3.1

Series 800 AWWA Butterfly Valves

MADE OF STAINLESS...

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

Materials : Cast iron or Stainless steel

FIRE PROTECTION PRODUCTS

Materials : Cast iron

BUTTERFLY VALVE - WAFER FAF 3500

American Flow control Series 2500

2 PIECES BALL VALVE PN63

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

Fire Protection Indicator Post

Transcription:

Water when you need it! AVK Belgium n.v.

It s all about constraining fire with water! Safety comes first don t compromise on the quality. AVK ensures a reliable water supply. We offer quality products with long life that operate faultless even after a long period of standstill. When every second counts you can count on valves and hydrants from AVK. 2 Valves and hydrants for fire protection

Hydrant with pumper connection: head loss = max 0.345 bar, when flow = 3785 L/min 30 Valves and hydrants for fire protection Weathershield note: open left shown. Technical appendix Flanges: Gate valves according to DIN - raised face, PN 10/16 600 840 685 725 770 29 5 34 37 20 20 M27 M33 Technical appendix Flanges: Gate valves accoring to AWWA C509, flat face ANSI B16.42, class 150 Dh ds Number D mm df dr mm of holes Bolt size DN mm cl. 125/150 mm mm cl. 125/150 cl. 125/150 cl. 125/150 50 152 121 15,8 3 19 4 M16 65 178 140 17,5 3 19 4 M16 80 191 152 19,1 3 19 4 M16 100 229 191 23,9 3 19 8 M16 150 297 241 25,4 3 22,2 8 M20 200 343 298 28,5 3 22,2 8 M20 250 406 362 30,2 3 25,4 12 M24 300 483 432 31,8 4 25,4 12 M24 350 533 476 35,1 4 28,6 12 M27 400 597 540 36,6 4 28,6 16 M27 Stop nut resting against internal lubrication reservoir in the nozzle section. EN 1092 / ISO 7005-2 450 635 578 39,6 4 33 16 M30 500 699 635 42,9 4 33 20 M30 600 813 749 47,8 5 36 20 M33 DN ds DN ds df dr df dr Dt Dt Dh D Dh D Valves and hydrants for fire protection 31 Complete assortment for fire protection Index Dry barrel hydrants series 27... 6 Post indicators and gate valves for post indicators... 14 Air valve for rapid filling and draining... 22 Gate valves for sprinkler systems... 24 Technical appendix Series 27 - flow/pressure loss/operation The AVK dry barrel hydrant meets or exceeds the requirements of FM 1510 and UL 246. Hydrant, bury depth of 1.5 meters to bottom of pipe: head loss = max. 0.069 bar per hose connection flow = min. 946 L/min per hose connection OPERATION AND MAINTENANCE The AVK modern hydrant is designed to be an easily operated, low torque, high flow fire hydrant. The thrust bearing hydrant requires a minimum of torque to operate. It is possible to damage the hydrant by forcing it beyond its limits of travel with excess torque; therefore: 1. Check direction of opening as marked on the hydrant weathershield. 2. To open, turn the operating nut in the opening direction, indicated by an arrow on the weathershield, until the main valve, is fully open (approximately 19 to 21 turns). The stop nut, should prevent the hydrant from opening beyond the fully open position. Do not force the hydrant in the opening direction beyond full open as indicated by sudden resistance to turning. If water does not flow when the hydrant is open, it is probably due to a closed valve upstream from the hydrant. 3. To close, turn the operating nut until the main valve stops off the flow. It is not necessary to close this type of hydrant with great force. Once the flow has stopped, loosen the operating nut in the opening direction, 1/2 to 1 turn to take the strain off the operating parts of the hydrant and to make it easier to open the hydrant. Dh ds Number D Dt mm df dr mm of holes Bolt size DN mm mm PN 10 PN 16 mm mm PN 10 PN 16 PN 10 PN 16 PN 10 PN 16 50 165 102 125 16 3 19 4 M16 65 185 122 145 16 3 19 4 M16 80 200 138 160 16 3 19 8 M16 100 220 158 180 16 3 19 8 M16 125 250 188 210 16 3 19 8 M16 150 285 212 240 16 3 23 8 M20 200 340 268 295 295 17 3 23 23 8 12 M20 M20 250 400 320 350 355 19 3 23 28 12 12 M20 M24 300 455 370 400 410 21 4 23 28 12 12 M20 M24 350 520 430 460 470 23 4 23 28 16 16 M20 M24 400 575 482 515 525 28 4 28 31 16 16 M24 M27 450 640 535 565 585 28 4 28 31 20 20 M24 M27 500 715 590 620 650 28 4 28 34 20 20 M24 M30 Technical appendix... 32 Valves and hydrants for fire protection 3

supervision of: Lead Auditor Bizonvej 1, DK-8464 Galten, Denmark Locations included in the certification will appear in the appendix. SYSTEM Reg.nr. 5001 Lack of fulfilment of conditions as set out in the Certification Agreement may render this certificate invalid. Smedeskovvej 40, DK-8464 Galten, Denmark has been found to conform to the safety management system standard: ACCREDITED UNIT: DET NORSKE VERITAS,BUSINESS ASSURANCE,DANMARK A/S, TUBORG PARKVEJ 8,2.,DK-2900, HELLERUP,DANMARK,TEL:+45 39 45 48 00, WWW.DNVBA.COM and Danish occupational health and safety regulation no. 87 dated 31 th of January 2005 This certificate is valid for the following product or service ranges: Design and production of valves and valve accessories. Marketing and sales of valves and Lead Auditor Locations included in the certification will appear in the appendix. SYSTEM Reg.nr. 6503 Lack of fulfilment of conditions as set out in the Certification Agreement may render this certificate invalid. Place and date: ACCREDITED UNIT: DET NORSKE VERITAS,BUSINESS ASSURANCE,DANMARK A/S, TUBORG PARKVEJ 8,2.,DK-2900, HELLERUP,DANMARK,TEL:+45 39 45 48 00, WWW.DNVBA.COM supervision of: Lead Auditor has been found to conform to the management system standard: SYSTEM Reg.nr. 6001 Place and date: ACCREDITED UNIT: DET NORSKE VERITAS,BUSINESS ASSURANCE,DANMARK A/S, TUBORG PARKVEJ 8,2.,DK-2900, HELLERUP,DANMARK,TEL:+45 39 45 48 00, WWW.DNVBA.COM Excellence in quality throughout the process DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE Certificate No. 05980-2003-AE-DEN-DANAK Certificate No. 05030-1998-AQ-DEN-DANAK This is to certify that This is to certify that AVK International A/S AVK International A/S Bizonvej 1, DK-8464 Galten, Denmark has been found to conform to the management system standard: DS/EN ISO 9001:2008 DS/EN ISO 14001:2004 This certificate is valid for the following product or service ranges: This certificate is valid for the following product or service ranges: Production of valves and valve accessories. Marketing and sales of valves and valve accessories Production of valves and valve accessories. Marketing and sales of valves and valve accessories Locations included in the certification will appear in the appendix. DNV BUSINESS ASSURANCE This certificate is valid until: 2015-03-31 MANAGEMENT SYSTEM CERTIFICATE The audit has been performed under the Certificate No. 05982-2003-AHSO-DEN-DANAK DANAK Place and date: Hellerup, 2012-06-01 DET NORSKE VERITAS, BUSINESS ASSURANCE, DANMARK A/S This certificate is valid until: 2015-03-31 The audit has been performed under the DANAK Hellerup, 2012-06-01 DET NORSKE VERITAS, BUSINESS ASSURANCE, DANMARK A/S Jens Østergaard Lars Appel Managing Director Jens Østergaard Lars Appel This is to certify that Managing Director AVK International A/S Lack of fulfilment of conditions as set out in the Certification Agreement may render this certificate invalid. DS/OHSAS 18001:2008 valve accessories This certificate is valid until: 2015-03-31 The audit has been performed under the supervision of: DANAK Hellerup, 2012-06-01 DET NORSKE VERITAS, BUSINESS ASSURANCE, DANMARK A/S Jens Østergaard Lars Appel Managing Director From design to finished product AVK s high design quality is based on thorough research of the customers needs. AVK products are manufactured in modern factories using high technology, computerised machining centres and robots to ensure precision and uniformity. The overall framework for quality from development to distribution is our extensive quality assurance system certified to ISO 9001. Optimum corrosion protection for maximum durability AVK products meet GSK requirements and conform to other international standards of effective corrosion protection. By virtue of our GSK membership (Gütegemeinschaft Schwerer Korrosionsschutz), our entire coating process complies with RAL-GZ 662 guidelines and is being monitored and approved twice a year by MPA-Hannover (Materialprüfanstalt), an independent testing institute. The step-by-step process with automatical monitoring of time, temperatures, coating thickness etc. ensures that each individual step is optimised to enhance the durability of the coating. 4 Valves and hydrants for fire protection

AVK builds long life and good economy into your fire protection systems Under control fire is invaluable, but out of control it can be devastating. Firemen risk their lives to extinguish fires. They rely fully on their equipment to function perfectly when needed. Therefore, it is crucial that the products installed are highly reliable, are easy to maintain and last a lifetime. AVK is a leading supplier of high quality hydrants and valves for fire protection and sprinkler systems. Our unique design and wide product range is based on the needs of customers worldwide. We offer a wide range of valves and hydrants which, along with a series of accessories, build the optimum solution. The complete fire protection package complies with international standards and consists of hydrants, NRS post indicator valves, handwheel operated OS&Y gate valves, post and wall indicators all UL/ ULC listed and FM approved. Furthermore, AVK holds VDS approval for NRS handwheel operated gate valves. Valves and hydrants for fire protection 5

Dry barrel fire hydrants Dry barrel fire hydrants are primarily designed for areas with frost, where the water main is located below ground frost zone. The series 27 dry barrel hydrant has two drain outlets located just above the water main level. The main valve disc is designed with the purpose of flushing the drain channels for soil and other impurities during opening. These impurities could lead to damage of the main valve disc. After turning the operation key 2 to 3 times the drain will stop flushing, and the barrel will be filled with water which will flow directly into the hoses and pumper connection or whatever is connected. Furthermore, when the hydrant is closed after service, the barrel will drain the water through the drain holes in the base. Therefore, it is important to make sure that the base is surrounded by gravel allowing the hydrant to drain and flush without washing off the soil. If not, this could result in under mining of the pavement. AVK dry barrel fire hydrants meet or exceed AWWA C-502 and are UL/ULC listed and FM approved. The fire hydrants are designed for high performance, easy repair and minimum end user costs for labor and inventory. Series 27 is available in different configurations. 6 Valves and hydrants for fire protection

All AVK hydrants offer numerous features including: Hydrant serviceable under pressure Light-weight, inexpensive hydrant tools available Ductile iron nozzle section, barrel section and base High pressure rating - 17.2 bar (250 PSI) Electrostatically applied epoxy coating in- and outside and above ground parts additionally with UV-resistant red polyester coating 360 nozzle section rotation possible Removable nozzles secured with external stainless steel allen screw Travel stop nut in the nozzle section for additional safety Pumper nozzle can be changed from 4" - 41/2" Nozzles available in most thread configurations Traffic flange designed for easy repair Stainless steel traffic coupling designed for longer operational life and high corrosion resistance Extensions available in lengths from 6"-60", bury depths 2'-13' Patented AVK main valve design - 1 piece replaces up to 13 pieces Ductile iron core fully encapsulated with EPDM rubber Completely corrosion resistant (stop pins of stainless steel) 51/4" valve opening for high flow rating 360 all bronze drain channel Inlet shoe can be easily changed - available in most configurations Internal trim for higher corrosion resistance Optional extra: Monitor elbow Multioutlet Handwheel Landing valves Valves and hydrants for fire protection 7

AVK DRY BARREL FIRE HYDRANT UL/FM approved, stem rod of SS AISI 316, 250 PSI 27/EM AVK dry barrel hydrants are designed with a traffic flange for easy repair after collision. The hydrant s main valve has a ductile iron core which is fully encapsulated in EPDM rubber. The nozzle section can be rotated 360 degrees. The upper section of the hydrant is repairable under pressure. Product Description: Dry barrel hydrant for fire protection application Outlets: 2 x 2½" NST hose nozzles + 1 x 4" BSP pumper nozzle, male threads Inlet: Straight shoe 6", ANSI B16.42, class 150 Standards: Designed according to AWWA C502 Flange drilling to ANSI B 16.42, class 150 Test/Approvals: Hydraulic test to AWWA C502. Body 2 x 250 PSI, seat 2 x 250 PSI FM approved. UL and ULC listed CE Reg.Nr. 0620-CPD-6122 Features: UL/ULC listed and FM approved Meets or exceeds AWWA C502 (latest) High pressure rating (250 psi) The breakable flange and stem rod coupling ensure no leaking and easy repair at traffic knock down Ductile iron nozzle section, barrel section, bonnet, and base 5.25 valve opening for high flow rating Hydrant drain easily plugged if required - may be plugged internally or externally Extensions available in lengths from 6 to 60 Inlet shoe is available as straight shoe or elbow shoe; in DN100, DN150 PN16 or 4", 6" ANSI class 150. Epoxy coating according to DIN 30677-2, GSK approved. Above ground parts additionally coated with red UV-resistant polyester coating NB. The hydrant is shown with accessories COPYRIGHT AVK GROUP A/S 2013 AVK Belgium N.V. 8 Valves and hydrants for fire protection

AVK DRY BARREL FIRE HYDRANT UL/FM approved, stem rod of SS AISI 316, 250 PSI 27/EM 762 504 2 4 5 7 9 10 11 12 18 19 20 18 23 19 20 Screw rotated 45 from true position Screw rotated 45 from true position 1 3 6 8 13 14 15 16 17 21 22 24 25 24 50 mm 19 26 27 28 189 34 35 36 6" flat face flange 30 29 31 32 33 Component list 1. Bolt Stainless steel 2. Weather shield Grey cast iron 3. Lubrication hole seal NBR rubber 4. O-rings NBR rubber 5. Lock plate and screw Stainless steel 6. Thrust nut Bronze 7. Stem nut Bronze 8. Nozzle section Ductile iron 9. Stop nut Stainless steel 10. Stem rod bushing Brass 11. O-rings NBR rubber 12. O-rings NBR rubber 13. Cap Ductile iron 14. Cap gasket NBR rubber 15. Nozzle Bronze 16. Nozzle O-ring NBR rubber 17. Cap chain Plated steel 18. Bolt Stainless steel 19. Lock ring Stainless steel 20. Barrel gasket, steel insert NBR rubber 21. Upper stem rod Stainless steel 22. Upper barrel Ductile iron 23. Breakable flange Ductile iron 24. Split bolt and pin Stainless steel 25. Breakable coupling Stainless steel 26. O-rings NBR rubber 27. Valve seat ring Bronze 28. Drain ring Bronze 29. Lower barrel Cast iron 30. Lower stem rod Stainless steel 31. Standpipe flange Cast iron 32. Threaded rod Stainless steel 33. Flanged inlet shoe Cast iron 34. Main flange gasket NBR rubber 35. O-ring NBR rubber 36. Main valve disc Iron core, EPDM rubber Reference nos. and dimensions Total Bury Therotical AVK ref. nos. DN length depth Weight mm mm mm Kg 27EMU72040AJ08CQ 150 1701 914 154.0 Valves and hydrants for fire protection 9

AVK DRY BARREL FIRE HYDRANT WITH MONITOR ELBOW UL/FM approved, stem rod of SS AISI 316, 250 PSI 27/CY AVK dry barrel hydrants are designed with a traffic flange for easy repair after collision. The hydrant s main valve has a ductile iron core which is fully encapsulated in EPDM rubber. The nozzle section can be rotated 360 degrees and fixed in four positions. The upper section of the hydrant is repairable under pressure. Product Description: Dry barrel hydrant for fire protection application Outlets: 2 x 2½" NST hose nozzles + 1 x 4" BSP pumper nozzle, male threads - monitor elbow 4" flange, ANSI B16.42, class 150 Inlet: Straight shoe 6", ANSI B16.42, class 150 Standards: Designed according to AWWA C502 Flange drilling to ANSI B 16.42, class 150 Test/Approvals: Hydraulic test to AWWA C502 body 2x250 PSI, seat 2x250 PSI FM Approved. UL and ULC listed. Features: UL/ULC listed and FM approved Meets or exceeds AWWA C502 (latest) High pressure rating (250 psi) Monitor elbow with 4" ANSI cl. 150 flange, optionally with 3" ANSI cl. 150 flange Ductile iron nozzle section, barrel section, bonnet, and base 5.25" valve opening for high flow rating Hydrant drain easily plugged if required - may be plugged internally or externally Extensions available in lengths from 6" to 60" Inlet shoe is available as straight shoe or elbow shoe; in DN100, DN150 PN16 or 4", 6" ANSI class 150 Epoxy coating according to DIN 30677-2, GSK approved. Above ground parts additionally coated with red UV-resistant polyester coating NB. The hydrant is shown with accessories COPYRIGHT AVK GROUP A/S 2013 AVK Belgium N.V. 10 Valves and hydrants for fire protection

AVK DRY BARREL FIRE HYDRANT WITH MONITOR ELBOW UL/FM approved, stem rod of SS AISI 316, 250 PSI 27/CY 2 4 4 flange and elbow, 5 available in 3 flange and elbow. 7 9 10 11 31 12 22 20 18 19 20 18 23 19 20 Bolt rotated 45 from true position Bolt rotated 45 from true position View A 1 3 6 8 13 14 15 16 17 21 22 24 25 24 50 mm 19 26 27 28 189 34 35 36 6" flat face flange 30 29 31 32 33 Component list 1. Bolt Stainless steel 2. Weather shield Grey cast iron 3. Lubrication hole seal NBR rubber 4. O-rings NBR rubber 5. Lock plate and screw Stainless steel 6. Thrust nut Bronze 7. Stem nut Bronze 8. Nozzle section Ductile iron 9. Stop nut Stainless steel 10. Stem rod bushing Brass 11. O-rings NBR rubber 12. O-rings NBR rubber 13. Cap Ductile iron 14. Cap gasket NBR rubber 15. Nozzle Bronze 16. Nozzle O-ring NBR rubber 17. Cap chain Plated steel 18. Bolt Stainless steel 19. Lock ring Stainless steel 20. Barrel gasket, steel insert NBR rubber 21. Upper stem rod Stainless steel 22. Upper barrel Ductile iron 23. Breakable flange Ductile iron 24. Split bolt and pin Stainless steel 25. Breakable coupling Stainless steel 26. O-rings NBR rubber 27. Valve seat ring Bronze 28. Drain ring Bronze 29. Lower barrel Cast iron 30. Lower stem rod Stainless steel 31. Standpipe flange Cast iron 32. Threaded rod Stainless steel 33. Flanged inlet shoe Cast iron 34. Main flange gasket NBR rubber 35. O-ring NBR rubber 36. Main valve disc Iron core, EPDM rubber Reference nos. and dimensions Total Bury Therotical AVK ref. nos. DN length depth Weight mm mm mm Kg 27CYU72040AJ08CQ 150 1701 914 154.0 Valves and hydrants for fire protection 11

AVK DRY BARREL FIRE HYDRANT Multi outlet type, stem rod of SS AISI 316, 250 PSI 27/EK AVK dry barrel hydrants are designed with a traffic flange for easy repair after collision. The hydrant s main valve has a ductile iron core which is fully encapsulated in EPDM rubber. The nozzle section can be rotated 360 degrees and fixed in four positions. The upper section of the hydrant is repairable under pressure. Product Description: Dry barrel hydrant for fire protection application Outlets: 2 x 2½" NST hose nozzles + 1 x 4" BSP pumper nozzle, male threads Multi outlet: 1 x 4" BSP female thread Inlet: Straight shoe 6", ANSI B16.42, class 150 Standards: Designed according to AWWA C502 Flate face flanges Test/Approvals: Hydraulic test to AWWA C502, body 2x250 PSI, seat 2x250 PSI Features: Meets or exceeds AWWA C502 (latest) High pressure rating (250 psi) Multi outlet with 4" BSP female thread, optionally additional 2 x 2½" hose outlets, BSP female thread Ductile iron nozzle section, barrel section, bonnet, and base 5.25" valve opening for high flow rating Hydrant drain easily plugged if required - may be plugged internally or externally Extensions available in lengths from 6" to 60" Inlet shoe is available as straight shoe or elbow shoe; in DN100, DN150 PN16 or 4", 6" ANSI class 150. Epoxy coating according to DIN 30677-2, GSK approved. Above ground parts additionally coated with red UV-resistant polyester coating NB. The hydrant is shown with accessories COPYRIGHT AVK GROUP A/S 2013 AVK Belgium N.V. 12 Valves and hydrants for fire protection

AVK DRY BARREL FIRE HYDRANT Multi outlet type, stem rod of SS AISI 316, 250 PSI 27/EK 762 504 2 4 5 7 9 10 11 12 18 19 20 18 23 19 20 Screw rotated 45 from true position Screw rotated 45 from true position 1 3 6 8 13 14 15 16 17 21 22 24 25 24 50 mm 19 26 27 28 189 34 35 36 6" flat face flange 30 29 31 32 33 Component list 1. Bolt Stainless steel 2. Weather shield Grey cast iron 3. Lubrication hole seal NBR rubber 4. O-rings NBR rubber 5. Lock plate and screw Stainless steel 6. Thrust nut Bronze 7. Stem nut Bronze 8. Nozzle section Ductile iron 9. Stop nut Stainless steel 10. Stem rod bushing Brass 11. O-rings NBR rubber 12. O-rings NBR rubber 13. Cap Ductile iron 14. Cap gasket NBR rubber 15. Nozzle Bronze 16. Nozzle O-ring NBR rubber 17. Cap chain Plated steel 18. Bolt Stainless steel 19. Lock ring Stainless steel 20. Barrel gasket, steel insert NBR rubber 21. Upper stem rod Stainless steel 22. Upper barrel Ductile iron 23. Breakable flange Ductile iron 24. Split bolt and pin Stainless steel 25. Breakable coupling Stainless steel 26. O-rings NBR rubber 27. Valve seat ring Bronze 28. Drain ring Bronze 29. Lower barrel Cast iron 30. Lower stem rod Stainless steel 31. Standpipe flange Cast iron 32. Threaded rod Stainless steel 33. Flanged inlet shoe Cast iron 34. Main flange gasket NBR rubber 35. O-ring NBR rubber 36. Main valve disc Iron core, EPDM rubber Reference nos. and dimensions Total Bury Therotical AVK ref. nos. DN length depth Weight mm mm mm Kg 27EKU72040AJ08CQ 150 1701 914 343 154.0 Valves and hydrants for fire protection 13

Post indicators and gate valves for post indicators Post indicators are mounted end to end with the extension spindle connecting the valve. It is mounted in places where direct access is impossible. It could be gate valves mounted on a water ring main in a factory area, such as oil refineries, chemical plants or airports. The post indicator indicates if the valve is in open or closed position. According to government regulations, it must be easy for firemen to see if the valve is open or closed, even at a long distance. The post indicator signs OPEN and SHUT are mounted on the target according to valve size. The post indicator valves are used for underground installation in fire protection systems. The post indicator flange is incorporated in the top gland, giving a compact design. The basic valve construction is, like the construction of valves Vejle Brandvæsen for water supply, characterized by a fully rubber coated wedge, full and straight bore, low torque operation and O-ring stem seals replaceable under pressure. UL/FM for DN 100-400 14 Valves and hydrants for fire protection

AVK series 34/00 post indicators for fire protection waiting to be installed under pressure at FM Logistic - Petresti, Romania. Resilient seated gate valves Metal seated gate valves Resilient seated gate valves A published test performed in City of Roseville, US, has proved that impurities up to Ø 8.7 mm can be handled by a DN 150 mm valve without any problems. The same test proved that the unique AVK EPDM rubber quality is the only rubber quality which instantly returns to the original shape when the valve is opened again. Valves and hydrants for fire protection 15

AVK FLANGED GATE VALVE, AWWA C509, 250 PSI 45/5D With post indicator plate and wrench nut, UL/FM approved, CTC AVK gate valves are designed with built-in safety in every detail. The wedge is fully vulcanized with AVK s own drinking water approved EPDM rubber compound. It features an outstanding durability due to the ability of the rubber to regain its original shape, the double bonding vulcanization process and the sturdy wedge design. The triple safety stem sealing system, the high strength stem and the thorough corrosion protection safeguard the unmatched reliability. Product Description: Flanged gate valve with post indicator plate for fire protection applications to max. 70 C Standards: Designed according to AWWA C509, Designed according to FM 1120/1130, UL 262 Face to face according to ANSI B16.10 Flange drilling to ANSI B16.42 cl. 150 Test/Approvals: Hydraulic test according to AWWA C509. Seat: 1.5 x PN (in Bar). Body: 2 x PN (in Bar). Operating torque test. FM Approved. UL listed. Features: Rated working pressure: DN 100-300 250 PSI, DN 350-400 200 PSI Fixed, integral wedge nut prevents vibration and ensures durability Fully vulcanized wedge with guide rails, integrated wedge shoes and a large conical stem hole Stem with wedge stop and rolled threads for high strength of aluminium bronze Stem sealing with an NBR wiper ring, two upper O-rings in a polyamide bearing, one lower O-ring and one O-ring gland seal Round NBR bonnet gasket fixed in a recess Countersunk and sealed acid-resistant stainless steel bonnet bolts encircled by the bonnet gasket Full bore Low operating torque Epoxy coating to DIN 30677-2 and AVK guidelines, RAL 3000 Accessories: Post indicator, wall post indicator COPYRIGHT AVK GROUP A/S 2013 2013-02-01 16 Valves and hydrants for fire protection

AVK FLANGED GATE VALVE, AWWA C509, 250 PSI 45/5D With post indicator plate and wrench nut, UL/FM approved, CTC 1 H 2 3 5 6 7 12 15 4 8 9 10 11 13 14 16 17 18 19 20 L Component list 1. Hexagon bolt Stainless steel 2. Washer Stainless steel 3. Wrench nut Grey cast iron 4. Gland bolt Stainless steel 5. Wiper ring NBR rubber 6. Bearing Polyamide 7. O-ring stem seal NBR rubber 8. Post indicator plate Ductile iron GJS-500-7 (GGG-50) 9. O-ring gland seal NBR rubber 10. Thrust collar Brass 11. O-ring stem seal NBR rubber 12. Bonnet bolt seal Hot melt 13. Bonnet Ductile iron GJS-500-7 (GGG-50) 14. Bonnet gasket NBR rubber 15. Bonnet bolt Stainless steel A4 16. Wedge nut Dezincification resistant brass 17. Stem Aluminium bronze 18. Wedge rubber EPDM rubber 19. Wedge Ductile iron 20. Body Ductile iron GJS-500-7 (GGG-50) Reference nos. and dimensions AVK ref. nos. DN L H Theoretical mm mm mm weight Kg 45-100-5D02614120 100 229 343 169.0 45-150-5D02614120 150 267 445 253.0 45-200-5D02614120 200 292 546 378.0 45-250-5D02614120 250 330 628 566.0 45-300-5D02614120 300 356 701 728.0 45-350-5D02614120 350 381 899 288.0 45-400-5D02614120 400 406 914 365.0 Valves and hydrants for fire protection 17

AVK FLANGED GATE VALVE, PN 10/16, DIN F5 With post indicator plate and wrench nut, FM approved, CTC 45/AD AVK gate valves are designed with built-in safety in every detail. The wedge is fully vulcanized with AVK s own drinking water approved EPDM rubber compound. It features an outstanding durability due to the ability of the rubber to regain its original shape, the double bonding vulcanization process and the sturdy wedge design. The triple safety stem sealing system, the high strength stem and the thorough corrosion protection safeguard the unmatched reliability. Product Description: Flanged gate valve with post indicator plate for fire protection applications to max. 70 C Standards: Designed according to EN 1074 part 1 & 2, Designed according to FM 1120/1130, Face to face according EN558 table 2, series 15 Standard flange drilling to EN1092 (ISO 7005-2), PN 10/16 Test/Approvals: Hydraulic test according to AWWA C509. Seat: 1.5 x PN (in Bar). Body: 2 x PN (in Bar). Operating torque test. FM Approved. Features: Rated working pressure: DN 100-300 250 PSI, DN 350-400 200 PSI Fixed, integral wedge nut prevents vibration and ensures durability Fully vulcanized wedge with guide rails, integrated wedge shoes and a large conical stem hole Stem with wedge stop and rolled threads for high strength of aluminium bronze Stem sealing with an NBR wiper ring, two upper O-rings in a polyamide bearing, one lower O-ring and one O-ring gland seal Round NBR bonnet gasket fixed in a recess Countersunk and sealed acid-resistant stainless steel bonnet bolts encircled by the bonnet gasket Full bore Low operating torque Epoxy coating to DIN 30677-2 and AVK guidelines, RAL 3000 Accessories: Post indicator, wall post indicator COPYRIGHT AVK GROUP A/S 2013 2013-02-01 18 Valves and hydrants for fire protection

AVK FLANGED GATE VALVE, PN 10/16, DIN F5 With post indicator plate and wrench nut, FM approved, CTC 45/AD H 1 2 3 5 6 7 12 15 4 8 9 10 11 13 14 16 17 18 19 20 L Component list 1. Hexagon bolt Stainless steel 2. Washer Stainless steel 3. Wrench nut Grey cast iron 4. Gland bolt Stainless steel 5. Wiper ring NBR rubber 6. Bearing Polyamide 7. O-ring stem seal NBR rubber 8. Post indicator plate Ductile iron GJS-500-7 (GGG-50) 9. O-ring gland seal NBR rubber 10. Thrust collar Brass 11. O-ring stem seal NBR rubber 12. Bonnet bolt seal Hot melt 13. Bonnet Ductile iron GJS-500-7 (GGG-50) 14. Bonnet gasket NBR rubber 15. Bonnet bolt Stainless steel A4 16. Wedge nut Dezincification resistant brass 17. Stem Aluminium bronze 18. Wedge rubber EPDM rubber 19. Wedge Ductile iron 20. Body Ductile iron GJS-500-7 (GGG-50) Reference nos. and dimensions AVK ref. nos. DN Flange L H Theoretical mm drilling mm mm weight Kg 45-100-AD00614120 100 PN10/16 300 343 169 45-150-AD00614120 150 PN10/16 350 445 253 45-200-AD00614120 200 PN10 400 546 378 45-200-AD01614120 200 PN16 400 546 378 45-250-AD00614120 250 PN10 450 628 566 45-250-AD01614120 250 PN16 450 628 566 45-300-AD00614120 300 PN10 500 701 728 45-300-AD01614120 300 PN16 500 701 728 45-350-AD00614120 350 PN10 550 899 288 45-350-AD01614120 350 PN16 550 899 288 45-400-AD00614120 400 PN10 600 914 365 45-400-AD01614120 400 PN16 600 914 365 Valves and hydrants for fire protection 19

AVK POST INDICATOR 34/00 For AVK post indicator valves, UL/FM 001 AVK post indicators have a unique telescoping stem design which eliminates the need to disassemble and saw off sections of the stem during installation. The operating wrench can be locked on to make the valves tamper proof, and the AVK post indicators have a pre-cast threaded boss for mounting a supervisory switch. Product Description: Post indicator - Telescopic Standards: Designed according to UL 789, Designed according to FM class no. 1110 Test/Approvals: FM Approved. UL listed. Features: UL/ULC Listed (DN 100-400) and FM approved (DN 100-350) Designed to operate on DN 100-400 indicator valves Telescopic indicator posts are available in 3 basic lengths. Each has a 23-inch adjustment range and can be easily adjusted in the field without disassembly. Prepared for supervisory switch Lockable with strap Head and bonnet of ductile iron with epoxy coating internally and externally and a topcoat of UV-resistant polyester coating externally. Lower barrel of cast steel with bitumen coating, optionally of PVC. COPYRIGHT AVK GROUP A/S 2013 2013-02-01 20 Valves and hydrants for fire protection

AVK POST INDICATOR 34/00 For AVK post indicator valves, UL/FM 001 1 14 955 mm 765 mm 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 Bury 260 18 19 20 18 21 22 23 24 25 H1 Valve size H1 mm/inch Component list 1. Stem nut Copper alloy 2. Operating wrench Ductile iron, GJS-500-7 (GGG-50) 3. Indicator bonnet Ductile iron, GJS-500-7 (GGG-50) 4. O-ring NBR rubber 5. Circlip ring Stainless steel A2 6. Indicator head Ductile iron, GJS-500-7 (GGG-50) 7. Target sign Aluminium 8. Bolt and washer Stainless steel Copper alloy 9. Target Copper alloy 10. Screw Stainless steel 11. Upper stem Galvanized steel 12. Lower stem Galvanized steel 13. Lower barrel Cast steel DN100/4 330/13 DN150/6 455/18 DN200/8 575/22½ DN250/10 685/27 DN300/12 785/31 DN350/14 980/38 ½ DN400/16 1010/39 ½ 14. Tension pin Stainless steel 15. Nut Stainless steel 16. Sign cover Glass 17. Spacer pipe Carbon steel 18. Bolt Stainless steel 19. Wrench nut Ductile iron, GJS-500-7 (GGG-50) 20. Tension pin Stainless steel 21. Set screw Stainless steel 22. Post indicator bell Ductile iron, GJS-500-7 (GGG-50) 23. Bolt, washer and nut Stainless steel 24. Post indicator valve Assemble 25. Bolt Stainless steel Reference nos. and dimensions AVK ref. nos DN T T factory Theoretical mm mm set mm weight kg 34-100-00-00010010 100 505-1090 635 72.0 34-100-00-01010010 100 1065-1660 1194 86.0 34-100-00-02010010 100 1626-2210 1752 100.0 34-150-00-00010010 150 505-1090 635 72.0 34-150-00-01010010 150 1065-1660 1194 86.0 34-150-00-02010010 150 1625-2210 1752 100.0 34-200-00-00010010 200 505-1090 635 72.0 34-200-00-01010010 200 1065-1660 1194 86.0 34-200-00-02010010 200 1625-2210 1752 100.0 34-250-00-00010010 250 505-1090 635 72.0 34-250-00-01010010 250 1065-1660 1194 86.0 34-250-00-02010010 250 1625-2210 1752 100.0 34-300-00-00010010 300 505-1090 635 72.0 34-300-00-01010010 300 1065-1660 1194 86.0 34-300-00-02010010 300 1625-2210 1752 100.0 34-350-00-00010010 350 505-1090 635 72.0 34-350-00-01010010 350 1065-1660 1194 86.0 34-350-00-02010010 350 1625-2210 1752 100.0 34-400-00-00010210 ¹ 400 505-1090 635 72.0 ¹ Only UL listed Valves and hydrants for fire protection 21

Air valve - for safety in your fire fighting pipe system K-060/62 HFNS Applications The K-HF NS series is adapted for clear water installation in dry fire protection where the filling and drainage operation has to be done quickly. Main features Reliable operation that reduces water hammer incidents. The controlled discharge of air (NS) will reduce surge effects and provide a silent closure of the air valve. Operation How to choose the right air valve? We offer you this service! - using a software program for the sizing and location of the air valve. The air and vacuum valve discharge air at high flow rates during the filling of the system and admits air at high flow rates during the drainage, pump shut-off or at water column separation. Description The K-060 NS series air and vacuum valve discharges air during the filling or charging of the system and admits air into the system during system drainage, valve or pump shut-off. The built-in throttling device on the non-slam disc will allow the graduated opening and closing of the disc orifice. Technical data According to the standard EN 1074-4 Working pressure type K-060 HFNS: PN 10 (0,1 à 10 bar) PN 16 (0,2 à 16 bar) Working pressure type K-062 HFNS: PN 25 (0,2 à 25 bar) Pressure test: each air valves are tested before leaving the plant at 1,5 x nominal pressure. Epoxy coating FBE according to DIN 30677-2 Dimensions BSPT (R): 2 Flange: DN 50 à DN 250 according to EN 1092-2 Working temperature - max. 60 C (90 C intermittent). Flange 10 bar 16 bar 25 bar DN 50 200 kg 320 kg 500 kg DN 80 510 kg 820 kg 1.280 kg DN 100 800 kg 1.280 kg 2.000 kg DN 150 1.800 kg 2.880 kg 4.500 kg DN 200 3.200 kg 5.130 kg 8.000 kg DN 250 5.000 kg 8.000 kg 12.500 kg 22 Valves and hydrants for fire protection

Non-slam combination air valve operation in rapid filling of the pipeline When water, rapidly filling the pipeline, pushes the air out through the air valve, a differential pressure is created across the orifice. When this differential pressure reaches a prefixed level (usually it will be prefixed at 0,02-0,03 bar) the orifice disc will close. Air will continue to come out through the small orifice disc - until all the air will be exhausted and water will Non-slam disc: The built-in throttling device on the non-slam disc of the K-60-HFNS combination air valve will allow for the graduated opening and closing of the disc orifice reach the kinetic float. This double stage kinetic air discharge prevents the slam effect therefore suppresses water hammer. When water reaches the kinetic float, it lifts it up, closing the kinetic orifice and completing the kinetic cycle. The throtteling device will come back to its normal open position. Draining. When water is drained out of the pipeline, the resulting pressure drop lets the kinetic float fall down, opening the orifice fully for intake of high volume of air into the line. Valves and hydrants for fire protection 23

Gate valves for sprinkler systems AVK resilient seated gate valves are designed with a fully vulcanized rubber wedge. With this design no iron parts are exposed to the medium, and the excellent rubber vulcanization prevents creeping corrosion underneath the rubber. The rubber is vulcanized onto the wedge by AVK GUMMI A/S, one of Europe's leading manufacturers of high technology moulded rubber components. The high quality of AVK rubber is characterized by: Smell and taste response characteristics highly suitable for the food industry Very low deformation ensuring optimum sealing High impact resistance preventing corrosion Low friction ensuring low closing torques EPDM rubber for water supply Standard stem sealing system applications to DIN standard. NBR wiper ring polyamid bearing with 4 O-rings EPDM rubber manchette OS&Y stem sealing system NBR wiper ring polyamid bearing with 2 O-rings, replaceable under pressure with the valve fully open. O-ring protects the antifriction washers 24 Valves and hydrants for fire protection

Gate valves with flanges and grooved ends -pin indicator and OS&Y Grooved end valves with pin indicator - series 06/37 The valves fit the quick clamp system and are machined according to AWWA C606. The grooved end on the valve is fixed to the pipe material e.g. steel or cast iron - by means of standard clamping couplings. Flanged valves OS&Y - series 45/56 The OS&Y gate valves with flanges are used in above ground installations. Due to the rising stem it is easy to recognize the valve position, open or closed, even at a distance. Over the past 75 years, the grooved end clamping system has proved to be one of the fastest and most efficient ways of joining pipes due to its high degree of flexibility and rigidity, as well as a fast and easy assembly. The basic valve design is characterized by a fully rubber coated wedge, full and straight bore, low torque operation and O-ring stem seals replaceable under pressure. The system absorbs vibrations and noise transmission through the system. It has a certain degree of angular deflection of the pipe joints and alignment in all positions 360º around the pipe axis. Therefore, the system has gained a footing in high rise buildings where vibrations and stress of pipe systems are of significant importance. The series 06/37 valve is a further development of the wellknown VdS-approved gate valve series 06/35 which was originally designed for sprinkler systems. This industry has recognised the time saving and effective way to connect pipes and fittings. GGG-50 DN 50-300 VdS-approved DN 50-200 DN 65-300 (21/2" - 12") UL-listed, FM-approved Flanged valves with pin indicator - series 06/35 The light weight flanged gate valve is very suitable for use in fire protection systems as an isolating gate valve for maintenance purpose. The pin indicator indicates the wedge position. Micro switches for remote indication of the wedge in open or closed position are available as an optional extra. The basic valve construction is, like the construction of valves for water supply, characterized by a fully rubber coated wedge, full and straight bore and 3 independant stem seals. GGG-50 Face to face to DIN 3202, F4 DN 50-400 VdS-approved DN 50-200 Valves and hydrants for fire protection 25

AVK FLANGED GATE VALVE, PN 10/16 DIN F4, pin indicator & handwheel, VdS approved, red RAL 3000 06/35 013 AVK gate valves are designed with built-in safety in every detail. The wedge is fully vulcanized with AVK s own drinking water approved EPDM rubber compound. It features an outstanding durability due to the ability of the rubber to regain its original shape, the double bonding vulcanization process and the sturdy wedge design. The triple safety stem sealing system, the high strength stem and the thorough corrosion protection safeguard the unmatched reliability. Product Description: Flanged gate valve with Pin Indicator for fire protection application to max. 70 C Standards: Designed according to EN 1074 part 1 & 2, Designed according to EN 1171 Face to face according to EN 558 Table 2 Basic Series 14 Standard flange drilling to EN1092 (ISO 7005-2), PN 10/16 Test/Approvals: Hydraulic test according to EN 1074-1 and 2 / EN 12266. Seat: 1.1 x PN (in Bar). Body: 1.5 x PN (in Bar). Operating Closing torque test. test. Approved according to VdS Certificate No. G 4960035 Features: Fixed, integral wedge nut prevents vibration and ensures durability Fully vulcanized wedge with guide rails, integrated wedge shoes and a large conical stem hole Stainless steel stem with wedge stop and rolled threads for high strength Full circle thrust collar provides fixation of the stem and low free running torques Triple safety stem sealing with an NBR wiper ring, a polyamide bearing with four NBR O-rings and an EPDM rubber manchette Round EPDM bonnet gasket fixed in a recess Countersunk and sealed stainless steel bonnet bolts encircled by the bonnet gasket Full bore Low operating torque Epoxy coating to DIN 30677-2 and AVK guidelines, RAL 3000 Accessories: Mounting kit for limit switch, limit switch, flange adaptor and combi-flange COPYRIGHT AVK GROUP 2013 Version no. 36-1/22/2013 9:29 AM 26 Valves and hydrants for fire protection

AVK FLANGED GATE VALVE, PN 10/16 DIN F4, pin indicator & handwheel, VdS approved, red RAL 3000 D 1 2 3 4 5 6 7 H A B 8 9 10 11 C 12 13 14 15 D L Component list 1. Handwheel Grey cast iron, GJL-250 (GG-25) 2. Stem Stainless steel min. 13% Cr 3. Pin Stainless steel 4. Indicator nut Dezincification resistant brass 5. Wiper ring NBR rubber 6. O-ring NBR rubber 7. Bearing Polyamide 8. Bonnet Ductile iron, min. GJS-400-15 (GGG-40) 9. Thrust collar Ductile iron, EN-GJS-500-7 (GGG-50) 10. Manchette EPDM rubber 11. Bonnet bolt Stainless steel A2, sealed with hot melt 12. Bonnet gasket EPDM rubber 13. Wedge nut Dezincification resistant brass 14. Wedge Ductile iron with EPDM rubber 15. Body Ductile iron, min. GJS-400-15 (GGG-40) Components can be substituted with equivalent or higher class materials. Reference nos. and dimensions DN Flange drilling L D H H3 Theoretical AVK ref. nos. mm drilling mm mm mm mm weight kg 06-050-35-01420 50 PN10/16 150 180 329 412 12.5 06-065-35-01420 65 PN10/16 170 225 355 448 16.0 06-080-35-01420 80 PN10/16 180 225 382 482 17.0 06-100-35-01420 100 PN10/16 190 280 414 524 26.5 06-125-35-01420 125 PN10/16 200 320 461 501 35.5 06-150-35-01420 150 PN10/16 210 320 540 683 50.5 06-200-35-00620 200 PN10 230 360 688 858 71.0 06-200-35-01620 200 PN16 230 360 688 858 71.0 06-250-35-00620 * 250 PN10 250 500 780 980 113.0 06-250-35-01620 * 250 PN16 250 500 780 980 113.0 06-300-35-00420 * 300 PN10 270 500 855 1083 116.0 06-300-35-01620 * 300 PN16 270 500 855 1083 160.0 06-350-35-00620 * 350 PN10 290 640 930 1190 203.0 06-350-35-01620 * 350 PN16 290 640 930 1190 203.0 06-400-35-00620 * 400 PN10 310 640 940 1248 240.0 06-400-35-01620 * 400 PN16 310 640 960 1248 240.0 * Not approved to VdS Valves and hydrants for fire protection 27

AVK GROOVED END GATE VALVE, PN 16 With pin indicator & handwheel, VdS approved, red RAL 3000 06/37 003 AVK gate valves are designed with built-in safety in every detail. The wedge is fully vulcanized with AVK s own drinking water approved EPDM rubber compound. It features an outstanding durability due to the ability of the rubber to regain its original shape, the double bonding vulcanization process and the sturdy wedge design. The triple safety stem sealing system, the high strength stem and the thorough corrosion protection safeguard the unmatched reliability. Product Description: Gate valve with grooved ends (AWWA C 606) and Pin Indicator for fire protection applications to max. 70 C Standards: Designed according to AWWA C606 Test/Approvals: Hydraulic test according to EN 1074-1 and 2 / EN 12266. Seat: 1.1 x PN (in Bar). Body: 1.5 x PN (in Bar). Operating Closing torque test. test. Approved according to VdS Certificate No. G 4070046 Features: Fixed, integral wedge nut prevents vibration and ensures durability Fully vulcanized wedge with guide rails, integrated wedge shoes and a large conical stem hole Stainless steel stem with wedge stop and rolled threads for high strength Full circle thrust collar provides fixation of the stem and low free running torques Triple safety stem sealing with an NBR wiper ring, a polyamide bearing with four NBR O-rings and an EPDM rubber manchette Round EPDM bonnet gasket fixed in a recess Countersunk and sealed stainless steel bonnet bolts encircled by the bonnet gasket Full bore Low operating torque Epoxy coating to DIN 30677-2 and AVK guidelines, RAL 3000 Accessories: Mounting kit for limit switch, limit switch COPYRIGHT AVK GROUP 2013 Version no. 41-1/22/2013 9:32 AM 28 Valves and hydrants for fire protection

AVK GROOVED END GATE VALVE, PN 16 With pin indicator & handwheel, VdS approved, red RAL 3000 06/37 003 H3 H W B DG D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A L Component List: 1. Handwheel Grey cast iron, GJL-250 (GG-25) 2. Stem Stainless steel min. 13% Cr 3. Pin Stainless steel 4. Indicator nut Dezincification resistant brass 5. Wiper ring NBR rubber 6. O-ring NBR rubber 7. Bearing Polyamide 8. Bonnet Ductile iron, min. GJS-400-15 (GGG-40) 9. Thrust collar Ductile iron, EN-GJS-500-7 (GGG-50) 10. Manchette EPDM rubber 11. Bonnet bolt Stainless steel A2, sealed with hot melt 12. Bonnet gasket EPDM rubber 13. Wedge nut Dezincification resistant brass 14. Wedge Ductile iron with EPDM rubber 15. Body Ductile iron, min. GJS-400-15 (GGG-40) Components can be substituted with equivalent or higher class materials. Reference Nos. and Dimensions: AVK ref. nos DN mm Product PN Class L mm H mm H3 mm W mm D mm DG mm A mm B mm Theoretical weight kg 06-050-37-09620 50 PN 10/16 178 329 367 180 60 57 16 8 10.0 06-080-37-09620 80 PN 10/16 203 382 435 225 89 85 16 8 15.0 06-100-37-09620 100 PN 10/16 229 414 480 280 114 110 16 10 22.0 06-150-37-09620 150 PN 10/16 267 540 649 320 168 164 16 10 44.0 06-200-37-09620 200 PN16 292 688 825 360 219 214 19 11 61.0 06-250-37-09620 (1) 250 PN16 330 780 925 500 273 268 19 13 94.0 06-300-37-09620 (1) 300 PN16 356 855 1025 500 324 318 19 13 126.0 (1) Not approved to VdS For further details see section "Technical Information". The designs, materials and specifications shown are subject to change without notice due to the continuous development of our product programme. Version no. 41-1/22/2013 9:32 AM Valves and hydrants for fire protection 29

AVK FLANGED GATE VALVE OS&Y, AWWA C509, 250 PSI With rising stem and handwheel, UL/FM approved, CTC 45/56 001 AVK gate valves are designed with built-in safety in every detail. The wedge is fully vulcanized with AVK s own drinking water approved EPDM rubber compound. It features an outstanding durability due to the ability of the rubber to regain its original shape, the double bonding vulcanization process and the sturdy wedge design. The triple safety stuffing box sealing system, the high strength stem and the thorough corrosion protection safeguard the unmatched reliability. Product Description: Flanged gate valve with rising stem OS&Y for fire protection applications to max. 70 C Standards: Designed according to AWWA C509, Designed according to FM 1120/1130, UL 262 Face to face according to ANSI B16.10 Universal flange drilling to EN1092 (ISO 7005-2), PN 10/16 Test/Approvals: Hydraulic tests according to AWWA FM and C509 UL Standards. Seat: 1.5 x PN (in Bar). Body: 2 x PN (in Bar). Closing torque test. FM Approved. UL listed. Features: Fixed, integral wedge nut prevents vibration and ensures durability Fully EPDM rubber vulcanized wedge in ductile iron with guide rails, integrated wedge shoes and a large conical stem hole Stem of copper alloy C36000 with wedge stop and rolled threads for high strength. DN 300 is of aluminium bronze. Stuffing box for re-tightening with three main O-rings, and two NBR O-rings in a polyamide gland bushing Round NBR bonnet gasket fixed in a recess Countersunk and sealed bonnet bolts of acid-resistant stainless steel A4 up to DN 200 and of anti-friction coated steel 12.9 in DN 250-400, encircled by the bonnet gasket Full bore Low operating torque Epoxy coating to DIN 30677-2 and AVK guidelines, RAL 3000. UV resistant coating on request. Accessories: Supervisory switch COPYRIGHT AVK GROUP 2013 Version no. 15-2/1/2013 12:14 PM 30 Valves and hydrants for fire protection

AVK FLANGED GATE VALVE OS&Y, AWWA C509, 250 PSI With rising stem and handwheel, UL/FM approved, CTC 45/56 001 D Hc 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Ho L Component List: 1. Stem nut Dezincification resistant brass 2. Handwheel Grey cast iron, GJL-250 3. Washer Zinc coated steel 4. Stud bolt Stainless steel A4 5. Yoke Ductile iron 6. Gland follower Ductile iron 7. Hexagon nut Stainless steel A2 8. Gland Polyamide 9. Washer RG5 bronze 10. O-ring SBR rubber 11. Gland bushing Polyamide 12. O-ring NBR rubber 13. Bonnet Ductile iron, min GJS-400-15 (GGG-40) 14. Bonnet bolt Stainless steel A4, sealed with hot melt 15. Bonnet gasket NBR rubber 16. Stem** Copper alloy C36000 ASTM B16 17. Pin Stainless steel A2 18. Wedge nut Dezincification resistant brass 19. Wedge Ductile iron with EPDM rubber 20. Body Ductile iron, min GJS-400-15 (GGG-40) * Bolt, DN 250-300 Steel 16.9, anti-friction coated ** Stem, DN 300: Aluminium bronze Reference Nos. and Dimensions: AVK ref. nos DN mm Flange drilling L mm H close mm H open mm D mm Turns to open Theoretical weight kg 45-065-56-01614020 (1) 65 PN10/16 190 332 398 229 17 19.0 45-080-56-01614020 (1) 80 PN10/16 203 350 429 229 20 25.5 45-100-56-01614020 (1) 100 PN10/16 229 420 524 279 21 38.0 45-150-56-01614020 (1) 150 PN10/16 267 581 736 330 26 63.0 45-200-56-00614020 (1) 200 PN10 292 736 942 356 35 96.0 45-200-56-01614020 (1) 200 PN16 292 736 942 356 35 96.0 45-250-56-00604020 (1) 250 PN10 330 882 1138 457 37 138.0 45-250-56-01604020 (1) 250 PN16 330 882 1138 457 37 138.0 45-300-5C-01604020 (2) 300 PN16 356 1009 1317 457 44 202.5 (1) UL/FM approved. Other flange drillings on request (2) Stem in alu. bronze. UL/FM approved. Other flange drillings on request (3) Stem in aluminium bronze. Other flange drillings on request For further details see section "Technical Information". The designs, materials and specifications shown are subject to change without notice due to the continuous development of our product programme. Version no. 15-2/1/2013 12:14 PM Valves and hydrants for fire protection 31

Series 27 - flow/pressure loss/operation The AVK dry barrel hydrant meets or exceeds the requirements of FM 1510 and UL 246. Hydrant, bury depth of 1.5 meters to bottom of pipe: head loss = max. 0.069 bar per hose connection flow = min. 946 L/min per hose connection Hydrant with pumper connection: head loss = max 0.345 bar, when flow = 3785 L/min OPERATION AND MAINTENANCE The AVK modern hydrant is designed to be an easily operated, low torque, high flow fire hydrant. The thrust bearing hydrant requires a minimum of torque to operate. It is possible to damage the hydrant by forcing it beyond its limits of travel with excess torque; therefore: 1. Check direction of opening as marked on the hydrant weathershield. 2. To open, turn the operating nut in the opening direction, indicated by an arrow on the weathershield, until the main valve, is fully open (approximately 19 to 21 turns). The stop nut, should prevent the hydrant from opening beyond the fully open position. Do not force the hydrant in the opening direction beyond full open as indicated by sudden resistance to turning. If water does not flow when the hydrant is open, it is probably due to a closed valve upstream from the hydrant. 3. To close, turn the operating nut until the main valve stops off the flow. It is not necessary to close this type of hydrant with great force. Once the flow has stopped, loosen the operating nut in the opening direction, 1/2 to 1 turn to take the strain off the operating parts of the hydrant and to make it easier to open the hydrant. Weathershield note: open left shown. Stop nut resting against internal lubrication reservoir in the nozzle section. 32 Valves and hydrants for fire protection

Flanges: Gate valves according to DIN - raised face, PN 10/16 EN 1092 / ISO 7005-2 Dh ds Number D Dt mm df dr mm of holes Bolt size DN mm mm PN 10 PN 16 mm mm PN 10 PN 16 PN 10 PN 16 PN 10 PN 16 50 165 102 125 16 3 19 4 M16 65 185 122 145 16 3 19 4 M16 80 200 138 160 16 3 19 8 M16 100 220 158 180 16 3 19 8 M16 125 250 188 210 16 3 19 8 M16 150 285 212 240 16 3 23 8 M20 200 340 268 295 295 17 3 23 23 8 12 M20 M20 250 400 320 350 355 19 3 23 28 12 12 M20 M24 300 455 370 400 410 21 4 23 28 12 12 M20 M24 350 520 430 460 470 23 4 23 28 16 16 M20 M24 400 575 482 515 525 28 4 28 31 16 16 M24 M27 450 640 535 565 585 28 4 28 31 20 20 M24 M27 500 715 590 620 650 28 4 28 34 20 20 M24 M30 600 840 685 725 770 29 5 34 37 20 20 M27 M33 dr DN Dt ds df Dh D Flanges: Gate valves accoring to AWWA C509, flat face ANSI B16.42, class 150 Dh ds Number D mm df dr mm of holes Bolt size DN mm cl. 125/150 mm mm cl. 125/150 cl. 125/150 cl. 125/150 50 152 121 15,8 3 19 4 M16 65 178 140 17,5 3 19 4 M16 80 191 152 19,1 3 19 4 M16 100 229 191 23,9 3 19 8 M16 150 297 241 25,4 3 22,2 8 M20 200 343 298 28,5 3 22,2 8 M20 250 406 362 30,2 3 25,4 12 M24 300 483 432 31,8 4 25,4 12 M24 350 533 476 35,1 4 28,6 12 M27 400 597 540 36,6 4 28,6 16 M27 450 635 578 39,6 4 33 16 M30 500 699 635 42,9 4 33 20 M30 600 813 749 47,8 5 36 20 M33 dr DN Dt ds df Dh D Valves and hydrants for fire protection 33

Technical appendix Corrosion protection and Rubber technology Blast cleaning All cast components are blast cleaned according to ISO 12944-4, SA 2½. The components are cleaned in a shot-blasting plant. The cleaned parts are held with fibre-free gloves and are transported to the oven without delay according to GSK specifications. When viewed, the surface shall be visibly free from oil, grease, dirt, mill scale, rust, paint and foreign objects. Any remaining traces of contamination shall show only as slight stains in the form of spots or stripes. The surface shall have a uniform metallic colour, visually and compared with test plates. The process ensures an optimum bonding of the coating, which is essential for corrosion resistance. Epoxy coating The valve bodies and bonnets are epoxy coated according to DIN 30677-2 and GSK guidelines. The epoxy coating is electrostatically applied in an enclosed coating booth, max. 4 hours after the valve components were blast cleaned. The epoxy powder melts between 200-230ºC, and cures when in contact with the cleaned and preheated component, ensuring an optimal bonding. Test procedure Coating thickness: The coating layer thickness shall be no less than 250 μ. Pore-free coating: The coating must be completely free of penetrating pores to avoid subsequent corrosion of the casting underneath. A 3V holiday detector with a brush electrode is used to electrically reveal and locate any pores in the coating. Impact resistance: The impact resistance test is carried out at least 24 hours after the coating process by means of a stainless steel cylinder dropped on the coating surface through a one meter long tube corresponding to an impact energy of 5 Nm. After each impact the component is electrically tested, and no electrical breakthrough shall occur. Cross linkage: Several drops of methyl isobutyl ketone are put on a horizontal epoxy resin coated surface of the test piece at room temperature. After 30 seconds the test area is wiped with a clean white cloth. It is checked that the test surface has not become neither matt nor smeared, and that the cloth remains clean. The test is carried out 24 hours after the coating process. Adhesion: The adhesion of the powder coating on one of each type of component is tested at least four times a year using the punch separation method according to DIN 24624. The coating thickness over a dispersed area of the test item shall be within the range 250 μ to 400 μ. The test pieces are immersed for seven days in deionised water at 90ºC, and then dried in an oven for 3 hours. A conditioning phase of 3 to 5 days in normal atmosphere is then allowed to elapse. No blisters may arise during the period immersed in the water bath. 34 Valves and hydrants for fire protection

Technical appendix Corrosion protection and Rubber technology The surface of the test piece is degreased and then roughened with abrasive paper. The roughened surface is cleaned from dust with oil-free compressed air and recleaned. The adhesion on both the core and the moulding sand sides is tested with a minimum pulling force of >12 N/mm². Cathodic disbonding: Cathodic disbonding tests are carried out on one of each type of component at least twice a year. No bubbles in the coating may develop during the test for cathodic disbonding. For this test, the coating thickness over a dispersed area of the test item shall be within the range 250 μ to 400 μ. Approvals: The coating is approved for use in drinking water systems, meeting all specified toxicological conditions, by the following institutes: Hygiene Institute, Germany Hydrocheck, Belgium CARSO L.S.E.H.L., France Rubber technology: The high quality rubber used in the wedge has an excellent compression set also called memory(the ability to recover the original shape after being compressed). Even after many years of operation, tiny pebbles, sand and other impurities will not affect the rubber surface or the tightness of the valve. Unique AVK rubber compounds are applied to ensure that the wedge can absorbe the impurities in closed position and is able to regain its original shape when it is opened again. EN 681-1 A common European standard stating the minimum requirements for the physical properties. Compression set (permanent deformation). The rubber is deformed by 25 % of its original thickness at a constant temperature for a specific time. The pressure on the rubber is relieved and the layer thickness is measured after half an hour. The smaller the deformation, the better the memory effect. 20 % compression set 15 10 5 0 EN 681-1 AVK EPDM AVK NBR EN 681-1 AVK EPDM 23ºC, 72 hours, 25 % 70ºC, 72 hours, 25 % AVK NBR Valves and hydrants for fire protection 35

AVK is certified according to ISO 9001, ISO 14001, and OHSAS 18001 AVK focuses on the environment AVK recognises the dangers of environmental impact also from a global point of view. AVK products are part of the infrastructure and as such they are an important part of the environment. Therefore, we constantly work on reducing this impact and seek to identify areas of improvement not only in our production processes but also in relation to our suppliers. At our factories and in all processes AVK works systematically on: always complying with environmental and work environmental legislation and other relevant requirements from authorities. reducing the amount of waste within the company. Where possible we recycle waste materials from production or alternatively apply the most environmentally friendly waste disposal methods. minimizing the consumption of energy and raw materials. minimizing the use of materials and processes which may be hazardous to the external environment or the work environment. informing and educating employees, enabling them to act in accordance with our environmental objectives and thereby contribute to minimising environmental hazard. taking environmental factors into consideration when choosing suppliers. advising customers on the use and disposal of our products. continuous improvement on prevention of pollution. AVK BELGIUM N.V. Zoomstraat 6A 9160 Lokeren Belguim Tel.: +3293481313 Fax: +3293493964 E-mail: info@avkvalves.be www.avkvalves.com 2013-03-01 Copyright AVK Group A/S 2013 Printed matter