TECHNICAL SPECIFICATION FOR ENERGY STORAGE SYSTEM REV 6.0

Similar documents
Catch Eco Range : Technical Specification Sheet

Power Whenever You Need

Power Whenever You Need

String Inverter (SUN KTL-A)

Energy Storage System for Home

All-in-one Storage Hybrid System

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

User Manual Rittal PMC UPS 6kVA

SOLA X INVERTER Product Brochure GET IN TOUCH: Global: AU: DE: UK:

Residential Energy Storage System SH 5K

Green Inverters from

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

RA.Store-K. The energy of the sun also at night...

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Residential Energy Storage System SH5K PV ESS

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw

Green Inverter from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Smarter inverter. Renac Power Technology Co.,Ltd. + Web:

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

CHANGE YOUR ENERGY CHARGE YOUR LIFE

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

SolarMax MT series The all-rounder for trade and industry

SolarMax P series The power package for residential solar plants

MERU Solar Off-Grid Inverters

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

CALL FOR A QUOTE (877)

Technical Specification

ABB central inverters PVS to 2000 kva

Smart Photovoltaic Inverter Series

SolarMax MT series. The power pack for maximum yields.

ABB central inverters PVS to 2091 kva

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

Growatt Storage Plus. Marketing Dept. Aug 2014

DATASHEET TECHNICAL INFORMATION. Stationary applications, island solutions

BRAVER UPS. (Uninterruptible Power System) User s Manual

UrVOLT. Products & Service

Technical specifications

House/Building Wind Power Storage Facility Supply Factory Supply. Ferry Energy Adjustment Grid Peaking Shaving

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

3.3kWh Battery Pack Specification 3.3

SUNNY TRIPOWER CORE1 - STP 50-40

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

SolarMax MT A series A reliable solution for commercial PV applications

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

The Traveler Series: Adventurer

Photovoltaics. MPI Hybrid Series

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

SOLON SOLiberty Energy Storage Solution. Greater Independence Through On-site Consumption.

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

Pre-announcement. Transformerless Solar Inverters

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Product Overview. 1.0 About VRB-ESS. 2.0 System Description. MW-Class VRB-ESS

MASS ENERGY INVERTER.

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

HYBRID INVERTERS for Energy Storage Systems. Renewable Energy on demand

+86(571) (571) (V4)

The Traveler Series TM : Adventurer

Solar inverter AX-series

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

Sonnenschein Lithium HC (High Current)

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Get ready for rising energy challenges. This is where xstorage Home can help

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

3 Phase Power Systems - Designed for Canada

Sunny Tripower CORE1.

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

SOLAR4SAVINGS SYSTEMS

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

2.1.Steca Solsum. Solsum 8.0c. Solar Charge Controller. Solsum 5.0c. Solsum 6.6c. Solsum 10.10c. 8.8c

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

EE152 Green Electronics

RS Stock number

Lithium Polymer Rechargeable Battery Pack Tested and approved to UN38.3

Energy Storage. Lithium Batteries

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

Technical specifications

TYPE:UP-SC3600mAh (Flat) Specifications. Dimensions. Typical characteristics Standard charge characteristics. Nominal voltage 1.2V.

BYD Distributed Energy Storage System (DESS) Integrated Type (European Version)

ENGLISH. RS Stock number Description:

RS Stock No

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

SOLAR ENERGY KIT MODEL: SISMA-CS3500

User Manual. 3kW Hybrid PV Inverter HX-3000

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

No Q/LX.S.E Edition A/0. Expocell Group, Inc. Cylindrical Li/MnO 2 Battery. Specification. Battery Type: CR123A(CR17345) Customer.

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

SOLAR ENERGY KIT MODEL: SISMA-CT20000

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

PowerRouter Solar Battery Self-use

Transcription:

TECHNICAL SPECIFICATION FOR ENERGY STORAGE SYSTEM Product Name Power Pillar SG Reviewed by: Liu Weiwei Draft by Zhang Guanqun REV 6.0

Contents 1. Generality... 2 2. Product Model Description... 2 3. Equipment Function... 2 4. Product Specification... 2 4.1 BMS... 2 4.2 Data sheet... 3 4.2.1 System Specification... 3 4.2.2 Battery Specification... 5 5. Storage and Maintenance... 6 5.1. Storage... 6 5.2. Maintenance... 6 1

1. Generality This document defines the technical specification for energy storage system Power pillar SG. 2. Product Model Description ESS - L 4 50 126-1 Power Version Low Voltage Voltage Capacity 3. Equipment Function Power Pillar SG is the all-in-one energy storage system integrating PCS, battery pack and battery management system. The battery pack is configured by a number of battery modules to store and supply the power, which is comprehensively monitored by the BMS to protect and surveil the battery pack. PCS has the AC-DC power converter function to store photovoltaic power or grid power into battery and convert DC power to feedback to the grid. 4. Product Specification 4.1 BMS High precision sampling of voltage and current Advanced algorithm of SOC/SOH and automatic calculation on the real time of SOC/SOH value Protection functions: Over and under voltage protection of battery pack and single cell; Over-current protection during charge and discharge Over and under temperature protection during charge and discharge Short circuit protection; Communication functions: including CAN or RS485; 2

4.2 Data sheet 4.2.1 System Specification PV String Input Data Max.DC Input Power 4600W Max.DC Input Voltage 580V MPPT Range 125V-550V Start-up Voltage 150V MPPT Range for Full Load 170V-500V Nominal DC Input Voltage 360V Max. Input Current 11/11A Max. Short Current 13.8/13.8A No. of MPP Trackers 2 No. of Strings per MPP Tracker 1 AC Output Data (On-grid) Nominal Apparent Power Output to Utility Grid 3680VA Max. Apparent Power Output to Utility Grid 3680VA Max. Apparent Power from Utility Grid 7360VA Nominal Output Voltage 230V single phase Nominal Output Frequency 50/60Hz Max. AC Current Output to Utility Grid 16A Max. AC Current From Utility Grid 32A Output Power Factor ~1 Output THDi (@Nominal Output) <3% Phase Single-phase AC Output Data (Back-up) Max. Output Apparent Power 3680VA Peak Output Apparent Power 5520VA,10S Max. Output Current 16A Nominal Output Voltage 230V(±2%) Nominal Output Frequency 50/60Hz(±0.2%) Output THDv (@Linear Load) <3% Battery Input Data Total Capacity 126Ah 100%SOC Usable Capacity 100Ah 80%SOC Nominal Voltage 50.4V charge model constant current/constant voltage CC/CV Charge Voltage 58.5V Charge Cut-off Voltage 58.5V 3

Discharge Cut-off Voltage 47.5V 80%SOC Discharge Cut-off Voltage 42V 100%SOC Max. Continuous Charge Current 75A Max. Continuous Discharge Current 75A Standard charge Constant Current 25A Standard discharge Constant Current 25A Efficiency Max. Efficiency 97.6% Max. Battery to Load Efficiency 94.0% Euro Efficiency 97.0% MPPT Efficiency 99.9% Protection Anti-islanding Protection PV String Input Reverse Polarity Protection Insulation Resistor Detection Residual Current Monitoring Unit Output Over Current Protection Output Short Protection Output Over Voltage Protection Grid Standard Safety Standard EMC Standard Certifications & Standards VDE-AR-N 4105, VDE0126-1-1, AS4777.2, G83/2, G100, CEI 0-21, NRS 097-2-1 IEC62109-1&2, IEC62040-1 EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4 General Data Weight 120kg Approx. Size (Width*Height*Depth ) +3/-3 601 1645 250mm Size Max. (Width*Height*Depth ) +3/-3 670 1645 286mm Cooling Natural Convection Noise (db) <25 Protection Degree IP54 User Interface LED;WED Operating Temperature 10~45 Storage Temperature -20~50 Relative humidity 0~95% 4

4.2.2 Battery Specification Battery Energy Battery pack Total Energy 6.4kWh 100%DOD Usable Energy 5.1kWh 80%DOD Nominal Voltage 50.4V Mean Operation Voltage Weight 45kg Approx. Energy Density ~142 (Wh/kg) Gravimetric Standard charge 25A CC&CV Max. constant current 75A Charge Limited voltage 58.5V Discharge Standard discharge Max. constant current 25A 75A Discharge Cut-off Voltage 47.5V 80% SOC Discharge Cut-off Voltage 42V 100% SOC Storage temperature Less than 12 months : -20~25 less than 3 months: -20~40 Less than 7 day : -20~65 Operating temperature Charge:10~45 Discharge:-20~60 Dimension(W*H*D)(mm.) 460*131*695 IP Rating IP65 Certifications CE,MSDS,UN38.3 Panasonic Cell Rated capacity 3000mAh Capacity Typical 3180mAh Standard discharge(0.2ca) Minimum 3030mAh after Standard charge Nominal Voltage 3.6V Mean Operation Voltage Weight Approx:49.5g Energy Density 217(Wh/kg) Gravimetric CC&CV Standard charge 909mA Charge Limited voltage 4.2V Discharge Standard discharge 909mA Limited voltage 2.5V Temperature Certifications Manufacturer Charge +10 ~ +45 Discharge -20 ~ +60 Storage -20 to +50 IEC62133,UL1642,PSE, MSDS,UN38.3 Panasonic Dimension(H*D)(mm.) 65.3*18 5

5. Storage and Maintenance 5.1. Storage Before storing, charge the battery at least 7 hours. Store the Battery covered and upright in a cool, dry location. Recommend long-term storage temperature is 15 C -25 C. During storage, please recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -20 C - 40 C Every 3 months Do a charge and discharge cycle, the battery charge storage 5.2. Maintenance The battery system operates with hazardous voltages. Only qualified maintenance personnel may carry out repairs. Even after the unit is disconnected from the mains, components inside are still connected to the battery cells, which are potentially dangerous. Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists at the terminals. Only persons who are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries. Verify that no voltage between the battery terminals and the ground is present before maintenance or repair. In this product, the battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Batteries may cause electric shock and have a high short-circuit current. Please remove all wristwatches, rings and other metal personal objects before maintenance or repair, and only use tools with insulated grips and handles for maintaining or repairing. When replace the batteries, install the same number and same type of batteries. When replace the parallel batteries, make sure the new battery is full charged. Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic. Please replace the fuse only with the same type and amperage in order to avoid fire hazards. Do not disassemble the battery system. 6

6. Drawing Battery Power Pillar SG 7