Programmable Output Module Installation Manual
PROGRAMMING CODE: (4 digits) (default = 1818) To enter programming mode, press [ ENTER] + programming code ADDRESS 000: 1 / 8 ADDRESS 001: 1 / 8 HOW TO: FEATURE SELECT (LIGHT ON/OFF) PROGRAMMING Feature selection programming addresses 002 to 008. The " ON"/" OFF" status of the lights (keys) determines features selected. 1) Press [ ENTER ] + installer code (default 1818), [ENTER] key will flash. 2) Enter 3 digit memory address ( 002 to 008). 3) Press corresponding key to select option. 4) To change selection press key again. 5) To save press [ENTER]. 6) Repeat steps 3 to 5 for addresses 002 to 008. 7) To exit programming mode press [CLEAR]. OUTPUT TYPES: (default = ) ADDRESS 002 ADDRESS 004 OFF ON OFF ON OFF ON EVENT / [KEY] / TIMER EVENT / [KEY] / TIMER EVENT / [KEY] / TIMER PGM 1 [3] PGM 9 [9] RLY 1 [3] PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 7 PGM 8 [1] [2ND] [6] [5] [4] [TRBL] PGM 10 PGM 11 PGM 12 PGM 13 PGM 14 PGM 15 PGM 16 [8] [7] [MEM] [12] [11] [10] [BYP] RLY 2 NOTE: When key light is "OFF", deactivation occurs as a result of an EVENT. When light is "ON", deactivation occurs following TIMER EXPIRATION. DEACTIVATION TYPES: (default = ) ADDRESS 006 PGM 1 PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 7 PGM 8 ADDRESS 008 OFF ON OFF ON OFF ON OR / [KEY] / AND OR / [KEY] / AND OR / [KEY] / AND [3] [1] [2ND] [6] [5] [4] [TRBL] PGM 9 PGM 10 PGM 11 PGM 12 PGM 13 PGM 14 PGM 15 PGM 16 [9] [8] [7] [MEM] [12] [11] [10] [BYP] RLY 1 RLY 2 [3] NOTE: When key light is "OFF", deactivation depends on "OR" logic. When light is "ON", deactivation depends on "AND" logic. ("EVENT" must be selected at address 002 or 004 as required.) 4
HOW TO: 3 DIGIT DECIMAL VALUE PROGRAMMING Decimalvalue programming addresses 010 to 063. Values entered mustcontain 3digits. 1) Press [ ENTER ] + installer code (default 1818), [ENTER] key will flash. 2) Enter 3 digit address ( 010 to 063). 3) Enter 3 digit DECIMAL value. 4) To exit, press [CLEAR]. To save press [ENTER]. 5) Go to step 2 for next address. To exit programming mode press [CLEAR]. Values entered at the 3 consecutive addresses corresponding to each PGM are defined as follows: PGMxx 1st address: 2nd address: 3rd address: First code of deactivation range OR TIMER SETTING PROGRAMMABLE OUTPUT: ADDRESS 010: 1 / 2 / 8 PGM 1 Zone 1 alarm (System A) 011: 1 / 3 / 3 PGM 1 Zone 6 alarm (System A) 012: 1 / 9 / 2 PGM 1 Zone 1 restored (System A) 013: 1 / 6 / 0 PGM 2 Zone 7 alarm (System B) 014: 1 / 6 / 5 PGM 2 Zone 12 alarm (System B) 015: 2 / 2 / 4 PGM 2 Zone 7 restored (System B) 016: 0 / 6/ 4 PGM 3 Armed by User 1 (System A) 017: 0 / 7 / 1 PGM 3 Armed by User 8 (System A) 018: 0 / 8 / 0 PGM 3 Disarmed by User 1 (System A) 019: 1 / 0 / 3 PGM 4 Armed by User 8 (System B) 020: 1 / 1 / 1 PGM 4 Armed by user 16 (System B) 021: 1 / 1 / 9 PGM 4 Disarmed by user 8 (System B) 022: 1 / 5 / 4 PGM 5 Battery fail 023: 1 / 5 / 4 PGM 5 Battery fail 024: 2 / 1 / 8 PGM 5 Battery restored 025: 0 / 6 / 0 PGM 6 Midnight 026: 0 / 6 / 0 PGM 6 Midnight 027: 0 / 0 / 1 PGM 6 1 second 028: 1 / 8 / 4 PGM 7 Panic 1 audible 029: 1 / 8 / 4 PGM 7 Panic 1 audible 030: 0 / 6 / 3 PGM 7 Alarm reset 031: 1 / 5 / 2 PGM 8 Max. aux. current trouble 032: 1 / 5 / 5 PGM 8 No AC 033: 2 / 1 / 6 PGM 8 Max. aux. current restored 034: 1 / 5 / 5 PGM 9 No AC 035: 1 / 5 / 5 PGM 9 No AC 036: 2 / 1 / 9 PGM 9 AC restored ADDRESS 037: 1 / 5 / 7 PGM 10 Timer loss 038: 1 / 5 / 7 PGM 10 Timer loss 039: 2 / 2 / 1 PGM 10 Timer loss restored 040: 0 / 6 / 2 PGM 11 TLM: panel 041: 0 / 6 / 2 PGM 11 TLM: panel 042: 2 / 2 / 3 PGM 11 TLM: panel restored 043: 1 / 5 / 8 PGM 12 Fire loop trbl. 044: 1 / 5 / 8 PGM 12 Fire loop trbl. 045: 2 / 2 / 2 PGM 12 Fire loop trbl. restored 046: 1 / 8 / 7 PGM 13 Partial arming 047: 1 / 8 / 7 PGM 13 Partial arming 048: 2 / 5 / 3 PGM 13 Disarm A Master 049: 1 / 8 / 4 PGM 14 Panic 1 050: 1 / 8 / 4 PGM 14 Panic 1 051: 0 / 6 / 0 PGM 14 Time 052: 1 / 8 / 5 PGM 15 Panic 2 053: 1 / 8 / 5 PGM 15 Panic 2 054: 1 / 2 / 0 PGM 15 Time 055: 1 / 8 / 6 PGM 16 Panic 3 056: 1 / 8 / 6 PGM 16 Panic 3 057: 1 / 2 / 0 PGM 16 Time 058: 1 / 2 / 8 RLY 1 Zone 1 alarm report (System A) 059: 1 / 5 / 1 RLY 1 Tamper 18 (748ES) (System A) 060: 2 / 4 / 0 RLY 1 061: 1 / 6 / 0 RLY 2 Zone 7 alarm report (System B) 062: 1 / 8 / 3 RLY 2 Tamper 24 (748ES) (System B) 063: 2 / 4 / 0 RLY 2 5
PROGRAMMING CODE: (4 digits) (default = 1818) To enter programming mode, press [ ENTER] + programming code ADDRESS 000: 1 / 8 ADDRESS 001: 1 / 8 OUTPUT TYPES: ADDRESS 002 OFF ON ADDRESS 003 OFF ON ADDRESS 004 OFF ON EVENT / [KEY] / TIMER EVENT / [KEY] / TIMER EVENT / [KEY] / TIMER PGM 1 [3] PGM 9 [9] RLY 1 [3] PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 7 PGM 8 [1] [2ND] [6] [5] [4] [TRBL] PGM 10 PGM 11 PGM 12 PGM 13 PGM 14 PGM 15 PGM 16 [8] [7] [MEM] [12] [11] [10] [BYP] RLY 2 DEACTIVATION TYPES: ADDRESS 006 OFF ON ADDRESS 007 OFF ON ADDRESS 008 OFF ON PGM 1 PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 7 PGM 8 OR / [KEY] / AND OR / [KEY] / AND OR / [KEY] / AND RLY 1 RLY 2 [3] [3] [1] [2ND] [6] [5] [4] [TRBL] PROGRAMMING WORK SHEET PGM 9 PGM 10 PGM 11 PGM 12 PGM 13 PGM 14 PGM 15 PGM 16 [9] [8] [7] [MEM] [12] [11] [10] [BYP] PROGRAMMABLE OUTPUT: ADDRESS 010: / / PGM 1 011: / / PGM 1 012: / / PGM 1 013: / / PGM 2 014: / / PGM 2 015: / / PGM 2 016: / / PGM 3 017: / / PGM 3 018: / / PGM 3 019: / / PGM 4 020: / / PGM 4 021: / / PGM 4 022: / / PGM 5 023: / / PGM 5 024: / / PGM 5 025: / / PGM 6 026: / / PGM 6 027: / / PGM 6 028: / / PGM 7 029: / / PGM 7 030: / / PGM 7 031: / / PGM 8 032: / / PGM 8 033: / / PGM 8 034: / / PGM 9 035: / / PGM 9 036: / / PGM 9 * * * 6 ADDRESS 037: / / PGM 10 038: / / PGM 10 039: / / PGM 10 040: / / PGM 11 041: / / PGM 11 042: / / PGM 11 043: / / PGM 12 044: / / PGM 12 045: / / PGM 12 046: / / PGM 13 047: / / PGM 13 048: / / PGM 13 049: / / PGM 14 050: / / PGM 14 051: / / PGM 14 052: / / PGM 15 053: / / PGM 15 054: / / PGM 15 055: / / PGM 16 056: / / PGM 16 057: / / PGM 16 058: / / RLY 1 059: / / RLY 1 060: / / RLY 1 061: / / RLY 2 062: / / RLY 2 063: / / RLY 2
EVENT CODE LIST 1 TIME SYSTEM A SYSTEM A SYSTEM A Nonreporting Armed by Alarm reports Zone restore reports 00 N/U 64 User 1 128 Zone 1 192 Zone 1 01 N/U 65 User 2 129 Zone 2 193 Zone 2 02 N/U 66 User 3 130 Zone 3 194 Zone 3 03 N/U 67 User 4 131 Zone 4 195 Zone 4 04 N/U 68 User 5 132 Zone 5 196 Zone 5 05 N/U 69 User 6 133 Zone 6 197 Zone 6 06 N/U 70 User 7 134 Tamper 1 198 N/U 07 N/U 71 User 8 135 Tamper 2 199 N/U 08 N/U 72 User 9 136 Tamper 3 200 N/U 09 N/U 73 User 10 137 Tamper 4 201 N/U 10 N/U 74 User 11 138 Tamper 5 202 N/U 11 N/U 75 User 12 139 Tamper 6 203 N/U 12 N/U 76 User 13 140 Zone 13 204 Zone 13 13 N/U 77 User 14 141 Zone 14 205 Zone 14 14 N/U 78 User 15 142 Zone 15 206 Zone 15 15 N/U 79 User 16 143 Zone 16 207 Zone 16 Disarmed by 16 N/U 80 User 1 144 Zone 17 208 Zone 17 17 N/U 81 User 2 145 Zone 18 209 Zone 18 18 N/U 82 User 3 146 Tamper 13 (748ES) 210 N/U 19 N/U 83 User 4 147 Tamper 14 (748ES) 211 N/U 20 N/U 84 User 5 148 Tamper 15 (748ES) 212 N/U 21 N/U 85 User 6 149 Tamper 16 (748ES) 213 N/U 22 N/U 86 User 7 150 Tamper 17 (748ES) 214 N/U 23 N/U 87 User 8 151 Tamper 18 (748ES) 215 N/U Trouble reports (System A/B) Trouble restored (System A/B) 24 N/U 88 User 9 152 Max. aux. current 216 Max. aux. current 25 N/U 89 User 10 153 Max. bell current 217 Max. bell current 26 N/U 90 User 11 154 Batt. fail 218 Batt. fail 27 N/U 91 User 12 155 No AC 219 No AC 28 N/U 92 User 13 156 Program Change 220 Tamper/wiring 29 N/U 93 User 14 157 Timer loss 221 Timer loss 30 N/U 94 User 15 158 Fire loop trbl. 222 Fire loop trbl 31 N/U 95 User 16 159 Test report 223 TLM: panel TIME SYSTEM B SYSTEM B SYSTEM B Nonreporting Armed by Alarm reports Zones restore 32 N/U 96 User 1 160 Zone 7 224 Zone 7 33 N/U 97 User 2 161 Zone 8 225 Zone 8 34 N/U 98 User 3 162 Zone 9 226 Zone 9 35 N/U 99 User 4 163 Zone 10 227 Zone 10 36 N/U 100 User 5 164 Zone 11 228 Zone 11 37 N/U 101 User 6 165 Zone 12 229 Zone 12 38 N/U 102 User 7 166 Tamper 7 230 N/U 39 N/U 103 User 8 167 Tamper 8 231 N/U 40 N/U 104 User 9 168 Tamper 9 232 N/U 41 N/U 105 User 10 169 Tamper 10 233 N/U 42 N/U 106 User 11 170 Tamper 11 234 N/U 43 N/U 107 User 12 171 Tamper 12 235 N/U 44 N/U 108 User 13 172 Zone 19 236 Zone 19 45 N/U 109 User 14 173 Zone 20 237 Zone 20 46 N/U 110 User 15 174 Zone 21 238 Zone 21 47 N/U 111 User 16 175 Zone 22 239 Zone 22 Disarmed by 48 N/U 112 User 1 176 Zone 23 240 Zone 23 49 N/U 113 User 2 177 Zone 24 241 Zone 24 50 N/U 114 User 3 178 Tamper 19 (748ES) 242 N/U 51 N/U 115 User 4 179 Tamper 20 (748ES) 243 N/U 52 N/U 116 User 5 180 Tamper 21 (748ES) 244 N/U 53 N/U 117 User 6 181 Tamper 22 (748ES) 245 N/U 54 N/U 118 User 7 182 Tamper 23 (748ES) 246 N/U 55 N/U 119 User 8 183 Tamper 24 (748ES) 247 N/U (System A/B) SPECIAL (System A/B) 56 N/U 120 User 9 184 Panic 1 248 No movement 57 N/U 121 User 10 185 Panic 2 249 N/U 58 N/U 122 User 11 186 Panic 3 250 N/U 59 N/U 123 User 12 187 Partial arming 251 N/U 60 Midnight 124 User 13 188 Arm A Espload 252 Disarm A Espload 61 Fail to comm. 125 User 14 189 Arm A Master 253 Disarm A Master 62 TLM: panel 126 User 15 190 Arm B Espload 254 Disarm B Espload 63 Alarm Reset 127 User 16 191 Arm B Master 255 Disarm B Master 7
EVENT CODE LIST 2 TIME SYSTEM A SYSTEM A SYSTEM A Nonreporting Armed by Alarm reports Zone restore reports 00 N/U 64 User 1 128 Zone 1 192 Zone 1 01 N/U 65 User 2 129 Zone 2 193 Zone 2 02 N/U 66 User 3 130 Zone 3 194 Zone 3 03 N/U 67 User 4 131 Zone 4 195 Zone 4 04 N/U 68 User 5 132 Zone 5 196 Zone 5 05 N/U 69 User 6 133 Zone 6 197 Zone 6 06 N/U 70 User 7 134 Zone 7 198 Zone 7 07 N/U 71 User 8 135 Zone 8 199 Zone 8 08 N/U 72 User 9 136 Zone 9 200 Zone 9 09 N/U 73 User 10 137 Zone 10 201 Zone 10 10 N/U 74 User 11 138 Zone 11 202 Zone 11 11 N/U 75 User 12 139 Zone 12 203 Zone 12 12 N/U 76 User 13 140 Zone 13 204 Zone 13 13 N/U 77 User 14 141 Zone 14 205 Zone 14 14 N/U 78 User 15 142 Zone 15 206 Zone 15 15 N/U 79 User 16 143 Zone 16 207 Zone 16 Disarmed by 16 N/U 80 User 1 144 Tamper 1 208 N/U 17 N/U 81 User 2 145 Tamper 2 209 N/U 18 N/U 82 User 3 146 Tamper 3 210 N/U 19 N/U 83 User 4 147 Tamper 4 211 N/U 20 N/U 84 User 5 148 Tamper 5 212 N/U 21 N/U 85 User 6 149 Tamper 6 213 N/U 22 N/U 86 User 7 150 Tamper 7 214 N/U 23 N/U 87 User 8 151 Tamper 8 215 N/U Trouble reports (System A/B) Trouble restored (System A/B) 24 N/U 88 User 9 152 Max. aux. current 216 Max. aux. current 25 N/U 89 User 10 153 Max. bell current 217 Max. bell current 26 N/U 90 User 11 154 Batt. fail 218 Batt. fail 27 N/U 91 User 12 155 No AC 219 No AC 28 N/U 92 User 13 156 Program Change 220 Tamper/wiring 29 N/U 93 User 14 157 Timer loss 221 Timer loss 30 N/U 94 User 15 158 Fire loop trbl. 222 Fire loop trbl 31 N/U 95 User 16 159 Test report 223 TLM: panel TIME SYSTEM B SYSTEM B SYSTEM B Nonreporting Armed by Alarm reports Zones restore 32 N/U 96 User 1 160 Zone 1 224 Zone 1 33 N/U 97 User 2 161 Zone 2 225 Zone 2 34 N/U 98 User 3 162 Zone 3 226 Zone 3 35 N/U 99 User 4 163 Zone 4 227 Zone 4 36 N/U 100 User 5 164 Zone 5 228 Zone 5 37 N/U 101 User 6 165 Zone 6 229 Zone 6 38 N/U 102 User 7 166 Zone 7 230 Zone 7 39 N/U 103 User 8 167 Zone 8 231 Zone 8 40 N/U 104 User 9 168 Zone 9 232 Zone 9 41 N/U 105 User 10 169 Zone 10 233 Zone 10 42 N/U 106 User 11 170 Zone 11 234 Zone 11 43 N/U 107 User 12 171 Zone 12 235 Zone 12 44 N/U 108 User 13 172 Zone 13 236 Zone 13 45 N/U 109 User 14 173 Zone 14 237 Zone 14 46 N/U 110 User 15 174 Zone 15 238 Zone 15 47 N/U 111 User 16 175 Zone 16 239 Zone 16 Disarmed by 48 N/U 112 User 1 176 Tamper 1 240 N/U 49 N/U 113 User 2 177 Tamper 2 241 N/U 50 N/U 114 User 3 178 Tamper 3 242 N/U 51 N/U 115 User 4 179 Tamper 4 243 N/U 52 N/U 116 User 5 180 Tamper 5 244 N/U 53 N/U 117 User 6 181 Tamper 6 245 N/U 54 N/U 118 User 7 182 Tamper 7 246 N/U 55 N/U 119 User 8 183 Tamper 8 247 N/U (System A/B) SPECIAL (System A/B) 56 N/U 120 User 9 184 Panic 1 248 No movement 57 N/U 121 User 10 185 Panic 2 249 N/U 58 N/U 122 User 11 186 Panic 3 250 N/U 59 N/U 123 User 12 187 Partial arming 251 N/U 60 Midnight 124 User 13 188 Arm A Espload 252 Disarm A Espload 61 Fail to comm. 125 User 14 189 Arm A Master 253 Disarm A Master 62 TLM: panel 126 User 15 190 Arm B Espload 254 Disarm B Espload 63 Alarm Reset 127 User 16 191 Arm B Master 255 Disarm B Master 8
CONNECTION DIAGRAMS Powered by control panel SERIAL PORT FROM PANEL J2 RESET TO OTHER MODULES J3 AUX + AUX GRN YEL N.O. COM N.C. N.O. COM - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 KEYPAD RLY#1 RLY#2 N.C. PANEL AUX + PANEL AUX - CONTROL RELAY (IF NECESSARY) KEYPAD RED BLK GRN YEL (Required for programming only) AUXILIARY POWER Powered by external power supply SERIAL PORT FROM PANEL J2 RESET TO OTHER MODULES J3 AUX + AUX GRN YEL N.O. COM N.C. N.O. COM - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 KEYPAD RLY#1 RLY#2 N.C. CONTROL RELAY (IF NECESSARY) KEYPAD RED BLK GRN YEL (Required for programming only) AUXILIARY POWER CONNECT AUX- OF AUXILIARY POWER SUPPLY TO AUX- OF SRI-18 CONNECT AUX- OF AUXILIARY POWER SUPPLY TO AUX- OF SRI-18 Paradox Security Systems Graphic Dept 780Industrial Blvd., St-Eustache, Montreal, Quebec, CanadaJ7R5V3Fax: (514) 491-2313 PRINTED IN CANADA 960429