G6125, 2-ay, Pressure ompensated langed Globe Valve pplication This valve is typically used in large air handling units on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. ronze or stainless steel trim valves can be used for steam applications, depending on actuator and close-off combination. Suitable ctuators Non-Spring Spring lectronic ail-safe G6125 V(X) 2*(X) VK(X) ate created, 01/19/2017 - Subject to change. elimo ircontrols (US), Inc. Technical ata 1828 Service chilled or hot water, up to 60% glycol, steam low haracteristic equal percentage ontrollable low ange stem up - open to Size [mm] 5 [125] nd itting 125 lb flanged ody cast iron - STM 126 lass (SM 16.1) Stem stainless steel Stem Packing NLP PM (no lip packing) Seat 316 stainless steel Plug brass ody Pressure ating [psi] NSI 125 NSI lass NSI 125 (up to 175 psi below 150 ) Number of olt Holes 8 Max Inlet Pressure (ater) 150 psi (1034 kpa) @ 250 Max Inlet Pressure (Steam) 35 psi (1 kpa) Media Temperature ange 32 to 338 [0 to 138 ] (ater) Media Temperature ange 32 to 280 [0 to 138 ] (Steam) Maximum ifferential Pressure 15 psi (103 kpa) (Steam) Max ifferential Pressure (ater) 25 psi (172 kpa) angeability 100:1 v 263 eight 147 lb [66.7 kg] Leakage NSI lass III Servicing epack/ebuild kits available low Pattern low arrow shown on rear of valve V, VX, V, VX 15.08 [383] 15.75 [400] 25.43 [646] 17.5 [445] 5 [127] Piping The valves should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow sufficient room for valve with actuator and for service. The preferred mounting position of the valve is with the valve stem vertical above the valve body, for maximum life. However, the assemblies can be mounted with valve stem vertical above the valve or up to 45 degrees in relation to the horizontal pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. o not reverse flow direction. 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MI / IN
G6125, 2-ay, Pressure ompensated langed Globe Valve 2*, 2*X 15.08 15.75 28.74 21 [533] 5 [127] 5.25 [135] [383] [400] [730] VK, VKX 15.08 [383] 15.75 [400] 25.43 [646] 17.5 [445] 5 [127] ate created, 01/19/2017 - Subject to change. elimo ircontrols (US), Inc. 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MI / IN
2*X-MT95-X1 Modulating, Spring eturn, V, 0 to 135 Ω Input ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc. Technical ata 2887 Power Supply V±20%, 50/60Hz, V+20%/-10% Power onsumption unning 7.5 Power onsumption Holding 3 Transformer Sizing 20 V (class 2 power source) lectrical onnection 18 G applicance rated cable with 1/2 conduit connector protected NM 2 (IP54) 3 ft [1m] 10 ft [3m] and 16 ft [5m] Overload Protection electronic throughout 0 to 95 rotation Operating ange Y on/off eedback Output U 2 to 10 V, 0.5 m max, V variable ngle of otation 95 (adjustable with mechanical end stop, 35 to 95 ) irection of otation (Motor) reversible with built-in switch irection of otation (ail-safe) reversible with / mounting Position Indication visual indicator, 0 to 95 (0 is full spring return position) Manual Override 5 mm hex crank (3/16 llen), supplied unning Time (Motor) 150 sec (default), variable (70 to 0 sec) unning Time (ail-safe) <20 sec Override ontrol min. position = 0%, mid. Position = 50%, max. position = 100% (efault) Humidity max. 95% H non-condensing mbient Temperature ange - to +1 [-30 to +50 ] Storage Temperature ange -40 to +176 [-40 TO +80 ] Housing NM 2, IP54, UL enclosure type 2 Housing Material zinc coated metal and plastic casing gency Listings culus acc. to UL60730-1/-2-14, N/S 60730-1:02, acc. to 2004/108/ Noise Level (Motor) <40 d () Noise Level (ail-safe) <62 d () Servicing maintenance free Quality Standard ISO 9001 eight 9.3 lb [4.2 kg] *Variable when configured with MT options. ated Impulse Voltage 800V, Type of action 1., ontrol Pollution egree 3 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MI / IN
2*X-MT95-X1 Modulating, Spring eturn, V, 0 to 135 Ω Input iring iagrams Meets culus requirements without the need of an electrical ground connection. 25 46 Provide overload protection and disconnect as required. ctuators may also be powered by V. ctuators and controller must have separate transformers. onsult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. ctuators may be controlled in parallel. urrent draw and input impedance must be observed. Switch Switch amper Position amper Open amper losed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. Typical and Override ontrol 135 lk (1) ed (2) Pnk ht Gry Org (6) (3) (7) (5) lk (1) ed (2) Pnk ht Gry Org (6) (3) (7) (5) low limit control 135 for 0 to 50% control 280 for 0 to 100% control Low Limit ontrol lk (1) ed (2) ht (3) low limit control - 280 High Limit ontrol lk (1) ed (2) ht (3) Shunting esistor lk (1) ed (2) + Hot ht (3) ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc. No. of actuators esistance 2 140 3 71.5 4 47.5 5 37.5 6 28 esistor Kit No. ZG-03 Multiple ctuators lk (1) ed (2) + Hot ht (3) 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MI / IN
2*X-MT95-X1 Modulating, Spring eturn, V, 0 to 135 Ω Input S963 Minimum Position Potentiometer Shunting esistor H205 hangeover Occupied ontact lk (1) ed (2) ht (3) + Hot lk (1) ed (2) + Hot ht (3) Multiple ctuators with Minimum Position Potentiometer Q209 Minimum Position Potentiometer H205 hangeover lk (1) ed (2) ht (3) Shunting esistor Y 973, 7100 Occupied ontact Honeywell T675 Morning armup lk (1) ed (2) ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc. No. of actuators esistance ht (3) 2 1300 Ω 3 910 Ω 4 768 Ω Used with the 973 and 7100 controllers Honeywell Q209 Minimum Position Potentiometer Shunting esistor 973, 7100 T775 Honeywell T675 Morning armup ht (3) lk (1) ed (2) ht (3) lk (1) ed (2) Multiple ctuators Used with 973, 7100 and T775 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MI / IN