COLD WEATHER START KIT Platinum Mini Split

Similar documents
COLD WEATHER START KIT Ceiling Mount 8000

Platinum Split 8000 & Platinum Split 8000 Fully Ducted COLD WEATHER START KIT Installation Manual

EasyStart Installation Instructions for Dometic Family RV A/Cs

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

ELECTRICAL SYSTEM UPGRADE

TK-6024, TK-6124, TK-8024, TK-8124

Installation Instructions for Lingenfelter GM 2500 Suburban & Yukon XL Auxiliary Fan System (with AC clutch controlled fan output)

Installation Instructions

MULTI-P URPOSE S HELTER

Agilent G1554A On-Column Capillary Inlet with EPC

Model 377, 379, 386, 388, Sleeper no window

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

401B/1KDB CoolRite/FreezeRite Installation Manual I003

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

WRX/STI Engine Oil Cooler

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

Splicing Procedures 4. 2 Insert the new wire between the parted strands. If more than one wire is being spliced, wrap them in opposite directions. Use

TOYOTA VENZA HANDS FREE BLU LOGIC Preparation

COBB 3-Port Electronic Boost Control Solenoid

BX8848 Installation Instructions 4 Diode Wiring Kit For Motorhomes With Red Tail Lights

WARNING Risk of property damage, injury, or death.

Signal Mirror Installation Instructions

Solstice Electric Fryers SE Series Service Manual

Installation Manual Camaro

IT IS IMPORTANT THAT YOU OBTAIN THE CORRECT INFORMATION FOR YOUR VEHICLE, OR DAMAGE TO THE WIRING SYSTEM COULD OCCUR.

The BTP Miata MX-5 Battery Relocation Kit. Installation and Operations Manual Applicable to all 2006 to 2015 Mazda Miata MX-5's

Installation Tips for your Remote Start system (for Toyota Camry & Prius C, ) Crimestopper RS0+ EVO-ALL T3468 rev#1.

Ford F-150 Supercrew A (2004 Heritage) Ford F-150 Super Cab A

Signal Mirror Installation Instructions Standard West Coast Mirror

Universal Splice Tray Installation Instructions

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: C

1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

REFRIGERATION PARTS SOLUTION

Conflicts: Vehicles without a sunroof Vehicles with a single sunroof

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Ford 6.7L Installation of the Guardian Safety System

Air Conditioner for M915 A0/A1 Truck

PART NUMBER: MINI Cooper S L4-1.6L SEE * NOTE

SUT-450-I ASSEMBLY REQUIREMENTS

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

80703 & Backside License Plate Mount for Jeep JK Wrangler (80707) & 10+ (80703)

THE safety accessory of the 21 st Century.

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

CSA CERTIFIED Conforms to UL 507

SUT-250-S (These instructions are used for SUT-250-SCLC also)

Service Bulletin Published by Sudden Service, Inc.

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

Please read thoroughly before starting installation and check that kit contents are complete.

SALEEN SPEEDLAB BOOST AND WATER TEMPERATURE GAUGE POD KIT

INSTALLATION INSTRUCTIONS

WARNING. Important Notice

Installation Instructions

Backside License Plate Mount for Jeep JK Wrangler

Rear Vision System Liftgate Emblem Camera for Aftermarket Display Ford Flex (Kit part number )

Ford F150 SuperCab Ford F150 SuperCrew

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

Handyman Motor Capacitor Meter PART NO

Trail Rocker Installation Instructions

Installation Instructions for Key Switch SNOWRATOR

Installation Manual #

Scion xa SATELLITE RADIO TUNER Preparation

Jeep Wrangler TJ. Complete Air Conditioning System. Slide Control Head. Installation instructions

Service Bulletin Published by Sudden Service, Inc.

INSTALLATION INSTRUCTIONS FOR COZY CAB A-1 AIR CONDITIONING KIT

MAZDASPEED3 Intercooler Instructions

Vortech Charge Air Cooler

MUSTANG GT

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Track Rocker Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE APPLICATION LENGTH MODEL YR PART #

CHEVY CAMARO Four panel Sequential LED Taillight kit installation guide

RZ3-5A Polaris RZR XP 1000 & 900 SSV Works 5 Speaker Audio Kit

LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

Installation Instructions for the Plug & Play Remote Start Package (EVOCHR5)

Illustrated Parts List MODEL. Reproduction Not for. 30,000 Watt Liquid Cooled Generator Systems

for Audi B7/A4 ( ) Part Number ES8017 Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

Installation Tips for your Remote Start/Keyless Entry (for Mazda Vehicles) v3.1 Updated 9/22/2012

Service Manual Mozart Fireplace

1. Disconnect the battery. This is important! This will prevent air bag deployment.

Installation Instructions for the Plug & Play Chrysler/Dodge/Jeep Remote Start Package w/mux T5

Do-It-Yourself Battery Pack

GENUINE PARTS INSTALLATION INSTRUCTIONS

08-18 STI Flex Fuel Bluetooth Mk2 Kit Install Instructions For Cobb Tuning Access Port

INSTALLATION INSTRUCTIONS

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

Ford F150 SuperCab A Ford F150 SuperCrew A

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions

TOYOTA CAMRY LE / SE / XLE DUAL SEAT HEATER KIT Section I Pre-Installation Check

3.4 AUXILIARY ACCESSORIES INSTRUCTIONS

MY F150 SuperCab 1. Tools Required. Page 1 of 12 9L3J-19A014-BA Copyright Ford 2013 FoMoCo

Installation Tips for your Add-on Remote Start (for GM vehicles with INTSL Install 2) v3.2 Updated 11/12/2012

2015 WRX Engine Oil Cooler

SOLAR BOLT CHARGING SYSTEM INSTALLATION GUIDE

Transcription:

COLD WEATHER START KIT Platinum Mini Split Cold Weather Start Kit: To be used in conjunction with Platinum Mini Split cooling system. The Coolest Thing In Wine Storage LASS.MPS 051515

Conforms to ANSI/UL Std 427 Certified to CAN/CSA Std C22.2 No. 120 We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry. Copyright 2012. WhisperKOOL. All rights reserved. WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the USA. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent of WhisperKOOL. Every effort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing or clerical errors. WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time, without notice. Vinothèque and WhisperKOOL are registered trademarks, and ECE is a trademark of WhisperKOOL. All rights reserved. Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a recommendation. WhisperKOOL assumes no liability with regard to the performance or use of these products. REV 02 LASS.MPS 051515

TABLE OF CONTENTS Receiving & Inspecting the System... 3 Before You Start... 4 Condensing Unit Cold Weather Start Kit Installation Instructions... 5 Evaporator Unit Cold Weather Start Kit Installation Instructions... 21 www.whisperkool.com Page 1

INTRODUCTION Customer Service Thank you for purchasing a WhisperKOOL Cold Weather Start Kit. We strive to provide the highest quality products and the best possible customer service. If you have any questions about your system, please call us at 1-800-343-9463 or visit WhisperKOOL.com. Using the Manual This Owner s Manual is intended to provide detailed instructions for the installation of the Cold Weather Start Kit to the Platinum Mini Split cooling system. In order to ensure the proper longevity of your cooling unit, the equipment should be installed as outlined in this Owner s Manual. It is also vital to establish a proper care and maintenance schedule. Please read and review this Owner s Manual carefully and keep it for future reference. What is a Cold Weather Start Kit? The Cold Weather Start Kit is designed to insure the start of your cooling system despite frigid ambient temperature that may result in failure of unit operation. The Cold Weather Start Kit will provide heat to the condensing unit when ambient temperature is too low. How Does the Cold Weather Start Kit Work? The Cold Weather Start Kit provides heat to specific components in the condensing unit for proper operation when the cooling system is in a below freezing setting. The Cold Weather Start Kit comes equipped with sensors to enable an ideal temperature boost every time. WARRANTY REGISTRATION In order to activate the warranty of your system, the Verification and Operational Documentation must be completed by the certified refrigeration technician installing your system and submitted via mail, fax or e-mail. Mail to: WhisperKOOL ATTN: Warranty Registration 1738 E. Alpine Avenue Stockton, CA 95205-2505 USA OR Fax to: 209-466-4606 OR Scan and e-mail to: warranty@whisperkool.com For the equipment warranty to be valid, WhisperKOOL requires that the installation is performed by a certified HVAC-R technician (NATE certified technician is recommended) per the specifications outlined in this Technician s Manual. The technician shall be required to be equipped with the proper tools of the trade including: R-134a, brazing equipment, dry nitrogen, an accurate manifold gauge set (digital preferred), plus a 4 valve manifold set for evacuation, digital micron gauge, digital scale, deep vacuum pump and accurate digital thermometers. Without the proper equipment, a professional job cannot be accomplished. Evidence of the certified tech s NATE# or other certification is required. Page 2 1-800-343-9463 LASS.MPS 051515

RECEIVING & INSPECTING THE SYSTEM Receiving and Inspecting the System Inspect the packaging for any obvious signs of damage or mishandling before opening the container. Note any discrepancies or visual damage on the Bill of Lading before signing. Review the Packing Slip to Verify Contents Check the model number to ensure it is correct. Check that all factory options ordered are listed. Before You Start If any items listed on the packing slip do not match your order information, contact WhisperKOOL Customer Service immediately. 1. Inspect the Kit before installation. If damage is found, please contact your distributor or WhisperKOOL Customer Service at 1-800-343-9463. 2. Verify that you have received all of the items on the Components Provided list below and that the Kit corresponds to your specific WhisperKOOL cooling system. 3. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar. 4. WhisperKOOL requires that all Systems and Cold Weather Start Kits be installed by a certified HVAC-R technician only. 5. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar. 6. Warranty is not active until a Warranty Checklist has been received, reviewed, and approved. Condensing Unit Components Provided: (1) Cold Weather Start Kit Electrical Box Assembly (1) Thermal Switch Assembly (1) H1 Lever Connector Assembly (2) Silicone Heaters (2) Yellow Female Disconnect (1) Red Female Disconnect (2) Hose Clamps (25) Zip Ties (3) Metal Zip Ties (4) 1/2 Hex Head Self Taping Screws (1) Piece of Heat Shield (1) Bag of Thermal Paste Evaporator Unit Components Provided: (4) Lever Connectors (1) 120v/24v Transformer (with double sided tape on bottom edge for mounting) (6) Zip Ties Set of Platinum Mini/WM2500CR Evaporator Unit Cold Weather Start Kit Field Installation Instructions. Tools Needed: #1 Philips Head Screw Driver #2 Philips Head Screw Driver 5/16 Nut Driver 1/4 Nut Driver Drill Wire Cutters Wire Strippers Crimpers Needle Nose Pliers Utility Knife Components of Needed: 2 Wire T-Stat Wire for routing from the evaporator unit (Air Handler) to the condensing unit. Use 18-20awg wire stranded or solid. After verifying that you have received all of the correct components for your specific system, please keep the Cold Weather Start Kit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions. TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit. www.whisperkool.com Page 3

BEFORE YOU START Shut Off Power going to the Evaporator and Condensing Unit. Disconnect both the evaporator unit (Air Handler) and the Condensing Unit from each power source. WARNING: Failure to do so may cause electrical shock which can result in injury or death. A 2 wire 18-20 awg thermostat wire will need to be ran from the evaporator unit to the condensing unit prior to installing the Cold Weather Start Kit. Review the Tools Needed and Components Provided document prior to starting. Page 4 1-800-343-9463 LASS.MPS 051515

CONDENSING UNIT COLD WEATHER START KIT INSTALLATION INSTRUCTIONS 1 Locate the electrical box. Use a Phillips head screwdriver and remove the three screws holding the electrical box cover on the electrical box. NOTE: Save screws 2 Remove the electrical panel to expose wiring as shown. 3 Cut all zip ties in side of the electrical box. 4 Remove the yellow wire nut from the 4 neutral wires. www.whisperkool.com Page 5

5 Separate, twist, and trim the copper strands of each wire to a length of 3/8. 6 Loosen the 2 Phillips screws on the cord squeeze. 7 Secure all 4 neutral wires into the lever connector labeled N1. NOTE: To secure a wire into the lever connector. Pull a lever to the open position, insert wire, and close lever. 8 Zip tie ground wires as shown. Page 6 1-800-343-9463 LASS.MPS 051515

9 Zip tie the black wires with the closed end terminal, as shown. 10 Remove the yellow female disconnect from the #8 terminal on the contractor. 11 Cut the yellow female disconnect off of the black and blue wires. 12 Strip the blue and black wires as shown. www.whisperkool.com Page 7

13 Secure both wires into the H1 lever connector. 14 Secure the red female disconnect labeled 8 onto the #8 terminal on the Magnecraft relay. 15 Remove the backing of the double sided tape from the bottom of the Cold Weather Start Kit electrical box. 16 Center the Cold Weather Start Kit box on the top of the condenser coil. (BE SURE TO PUSH THE PLASTIC STRAP ON THE BOX ALL THE WAY AGAINST THE COIL COVER.) Page 8 1-800-343-9463 LASS.MPS 051515

17 Route wires 7, 10, 11 & 12 from the Cold Weather Start Kit box down the fan shroud and into the cord squeeze as shown. 18 Secure wire 7 into the H1 lever connector. 19 Disconnect the yellow female disconnect from the #3 terminal on the DOB relay. 20 Cut the yellow female disconnect off of the blue and black wires from the previous step. www.whisperkool.com Page 9

21 Strip the blue and black wires from the previous step. 22 Crimp a red female disconnect labeled 3 onto the black wire from the previous step. 23 Secure the red female disconnect from the previous step to the #3 terminal on the DOB relay. 24 Crimp a wire end terminal onto wire 12 and the other stripped wire from a few steps ago. Page 10 1-800-343-9463 LASS.MPS 051515

25 Disconnect the blue female disconnect from the #1 terminal on the DOB relay. 26 Cut the blue female disconnect from the previous step off of the black wire. 27 Strip the black wire from the previous step. 28 Crimp a yellow female disconnect labeled 1 onto wire 11 and the black wire from the previous step. www.whisperkool.com Page 11

29 Secure the yellow female disconnect from the previous step to the #1 terminal on the DOB relay. 30 Zip tie wires 7, 10, 11 & 12 from the Cold Weather Start Kit box to the fan shroud as shown. 31 Zip tie the wires going into the N1 and H1 lever connectors as shown. 32 Tuck the wires into the electrical box and zip tie as shown. Page 12 1-800-343-9463 LASS.MPS 051515

33 Secure the 2 screws on the cord squeeze. 34 Secure top onto the electrical box using the removed screws. 35 Cut and remove the zip tie holding the fan and ground wires to the capacitor bracket on the compressor. NOTE: Remove all labels from receiver. BE CAREFUL NOT TO CUT THE WIRES. 36 Locate the two 40 watt silicone heaters. www.whisperkool.com Page 13

37 Peel off adhesive backing from each of the silicone heaters. 38 Place one of the silicone heaters on the receiver in the location shown. The heater will not adhere completely, there are hose clamps installed later in these instructions that will keep them firmly in place. NOTE: Line up the heater so the wires are located at the fan shroud, and the bottom of the heater is touching the liquid line. 39 Place the other silicone heater on the receiver in the location shown. The heater will not adhere completely, there are hose clamps installed later in these instructions that will keep them firmly in place. NOTE: Line up the heater so the wires are located at the fan shroud, and the back edge of the heater is touching the back edge of the other heater, as shown. 40 Using a 5/16 nut driver loosen the hose clamp and remove the strapping from the screw housing as shown. Page 14 1-800-343-9463 LASS.MPS 051515

41 Slide the hose clamps on the receiver over the silicone heaters. One at the top of the heaters and one at the bottom. Secure in place as shown. 42 Wrap the spring from the thermal switch around the liquid line and secure the clasp of the spring to the thermal switch as shown. 43 Slide the thermal switch to the location shown. Make sure the tab of the thermal switch rests on the screw terminal of the top hose clamp. NOTE: Make sure the surface of the thermal switch is located at the ridge of the receiver, and is making good contact. www.whisperkool.com Page 15

44 Pull the two bottom wires towards the fan shroud and cut as shown (One wire from each heater). 4 45 Strip and crimp on the yellow insulated female disconnect labeled T. 46 Connect the yellow disconnect labeled T and the red disconnect labeled T from the Cold Weather Start Kit electrical box, to the thermal switch. 47 Remove the top from the Cold Weather Start Kit electrical box. Page 16 1-800-343-9463 LASS.MPS 051515

48 Route white wires from the heaters up into the Cold Weather Start Kit box and zip tie wires in orientation shown. 49 Cut corner of zip lock bag containing Thermal Paste, as shown. 50 Apply thermal paste on the surface of the thermal switch. This will help with the accuracy of the thermal switch. Re-align switch so it sits in the same orientation as step 41. 51 Secure the white wires from the heaters to the lever connector labeled N2. www.whisperkool.com Page 17

52 Route the 24v control wires into the Cold Weather Start Kit electrical box. 53 Connect the 24v control wires to the grey and purple wires using the wire nuts provided. 54 Zip tie wires as shown. 55 Secure the Cold Weather Start Kit box to the top of the coil using the ½ self taping screws provided. (Using screws or mounting locations other than the ones specified, may result in a punctured coil.) Page 18 1-800-343-9463 LASS.MPS 051515

56 Tuck wires in Cold Weather Start Kit box as shown. 57 Secure top onto Cold Weather Start Kit box with removed screws. 58 Place a piece of heat shield behind the condenser fan wires and the ground wire. 59 Tightly wrap the heat shield around the wires. www.whisperkool.com Page 19

60 Secure the heat shield in place using three the metal zip ties. 61 Slide the heat shield over the wires up to the condenser fan motor and zip tie to capacitor bracket as shown. NOTE: Ensure there is a distance of 1 between the receiver and the heat shield. This is very important as it will prevent the possibility of the receiver heater burning the wires. The Cold Weather Start Kit has been successfully installed on the condensing unit, next proceed to the evaporator unit instructions. Page 20 1-800-343-9463 LASS.MPS 051515

EVAPORATOR UNIT Cold Weather Start Kit INSTALLATION INSTRUCTIONS 1 Before beginning the installation process, locate the Evaporator Unit Cold Weather Start Kit. All parts for the Evaporator Unit are located inside of this box. 2 Open box and remove the 24v transformer and the zip lock bag. 3 The kit will include six zip ties, four lever connectors, and one 120v/24v step down transformer. 4 Using a Phillips head screw driver loosen the 4 Phillips head screws on the electrical panel. Allow the panel to hang from the unit. (Note: The screws do not come out of the panel.) www.whisperkool.com Page 21

5 Remove the grill. Grab the top and bottom edges of the grill and pull it strait away from the evaporator unit. 6 Remove the backing from the double sided tape on the bottom edge of the transformer. 7 Place one edge of the transformer underneath the fan shroud as shown. Make sure the blue and yellow wires are directed towards the back of the unit and the black and white wires are directed toward the front of the unit. 8 Press bottom edge of the transformer firmly against the bottom of the unit, as shown. Page 22 1-800-343-9463 LASS.MPS 051515

9 Route the two wire cable through the half moon cutout at the rear of the unit. 10 Push wire through from other side until the end of the cable can be reached. 11 Pull the slack out of the wires until the two butt splices touch the metal divider. 12 Secure cable to existing wire harness using three zip ties. www.whisperkool.com Page 23

13 Cut the zip tie holding the wiring harness to the cable tie holder. 14 Remove cut zip tie. 15 Cut the blue wire and one white wire approximately 1 from the transformer, as shown. 16 Strip the ends of each wire to a length of 3/8. Page 24 1-800-343-9463 LASS.MPS 051515

17 Secure the two blues from the unit and the black wire from the transformer into a lever connector. 18 Secure the two white wires from the unit and the white wire from the transformer into a lever connector. 19 Secure the wiring back in place using three zip ties. (One of the three will be routed through the cable tie holder) 20 Un-twist the two wires from the cable that was routed through the metal divider. www.whisperkool.com Page 25

21 Secure one of the thermostat wires and the red wire coming from the 24v side of the transformer into a lever connector. 22 Secure the other thermostat wire and the black wire coming from the 24v side of the transformer into a lever connector. 23 Tuck control wires underneath the drip tray as shown. 24 Reinstall filter grill, as shown. Page 26 1-800-343-9463 LASS.MPS 051515

25 Using a Phillips head screw reinstall the grill by securing the 4 Phillips head screws on the electrical panel, to the unit. The Cold Weather Start Kit has been successfully installed on the Evaporator Unit. If the installation process is complete on the condensing unit as well, plug both the condensing unit and evaporator units back into a power source. www.whisperkool.com Page 27

WhisperKOOL 1738 E. Alpine Ave Stockton, CA 95205 1-800-343-9463 www.whisperkool.com LASS.MPS 051515