Power In - Pathways Technology Wall NOTE: With an off module application involving the transition of cabling or electrical harnesses, you will have to drill a maximum of a 2-1/2" hole in the beltway trim piece to allow for cable and/or electrical harnesses to pass through. Reference assembly direction 939504712 for more details. 1-1/4" Hole Saw or Drill FLOOR POWER IN - BELT HIGH BASE POWER IN MULTI-PURPOSE HARDWIRE POWER IN MULTI-PURPOSE MODULAR POWER IN #2 ACR2 8-18 x 3/8" Pan Head Tapping Screw If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500) Or visit our website: www.steelcase.com 2003 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. 1/4-20 x 7/8" Hex Head Tapping Screw WARNING: All electrical installations should be done by a qualified person in accordance with codes and regulations applicable at the installation site. Circuits should be checked for proper voltage. Note Chicago Only: Must be hard wired under authority of a permit by a contractor licensed in the City of Chicago. Page 1 of 12
Floor Power In - Belt High 1. Locate slot opening in lower horizontal. 2. Route cable through slot and up. 1 2 Page 2 of 12
3. Route cable to bracket-power block/communication. 4. Secure strain relief bracket to lower rail at slot using two (2) screws. 3 Page 3 of 12
6a 5. Install base trim. 6. Install cover over harness by hooking cover into the top of the receptacle opening (6a) then swing and squeeze cover into the bottom of the receptacle opening (6b). 6b 6 TIP: If elbow interfered with the installation of the cover. Pull elbow to the side, snap cover on, then slide elbow back under cover. 5 Page 4 of 12
Base Power In - Standard 1. Install the floor power-in feed into the receptacle opening of the power block. Route base power-in harness through the backside of the base trim knockout before hard wiring. 2. Swing cable outward. 3. Install base cover. 2 3 1 Page 5 of 12
4. Attach power infeed cover (4a) with two long screws (4b). 4b 4a Page 6 of 12
Multi-Purpose Hardwire Power In 1. Attach harness to non base power kit. Page 7 of 12
2. Feed harness through wall and attach loose end to a junction box. Junction box can be located in a wall or in the ceiling. See power pole installation instructions. 3. Wire to building wiring infrastructure. Page 8 of 12
Page 9 of 12
Multi-Purpose Modular Power In 1. Locate junction box in wall or ceiling. Wire plate appropriately to building wiring and attach plate to box. 2. Attach harness to connector. Page 10 of 12
3. Engage strain relief cover onto plate and harness. 4. Route harness to non base power kit and connect. #8-18 x 3/8" Pan Head Page 11 of 12
3+1 Powered by Separate Panels 3+1 Powered by Single Panel L1/L2/L3 Neutral (White) Systems Ground (Green) LINE 1 (Black) LINE 2 (Red) LINE 3 (Blue) LINE 4 (Pink) L1/L2/L3 Neutral (White) L4 Neutral (Gray) WIRING SCHEMATICS: Line 4 (Pink) L4 Neutral (Gray) Systems Ground (Green) NOTE: L-4 may be connected to P-1, P-2, or P-3. NOTE: L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading. ELECTRICAL DATA: 2+2 Powered by Separate Panels 2+2 Powered by 3-Phase Single Panel 2+2 Powered by Split-Phase Panel 120 V 60 HZ 20 Amp USA & CANADA Wiring schematics must be followed to prevent overloading of the neutrals. L1/L2 Neutral (White) System Ground (Green) Line 4 (Pink) P-1 P-2 Line 4 (Pink) WARNING: Risk of Fire or Electric Shock: This office furnishing system may be connected to more than one source of supply. All sources must be disconnected prior to any servicing. No single circuit may be powered by more than one source. Line 4 (Pink) L3/L4 Neutral (Gray) NOTE: Line 3 or 4 should alternate between phases to balance circuit loading. L1/L2 Neutral (White) L3/L4 Neutral (Gray) System Ground (Green) NOTE: L-4 should alternate between P-1 and P-2 to balance circuit loading. L1/L2 Neutral (White) L3/L4 Neutral (Gray) System Ground (Green) 3 SepN Powered by Separate Panels 3 SepN Powered by Single Panel 3 SepN Powered by Split-Phase Panel L1 Neutral (White) L2 Neutral (Gray) Systems Ground (Green) L3 Neutral (White/Gray) Isolated Ground (Green/Yellow) L1 Neutral (White) L2 Neutral (Gray) L3 Neutral (White/Gray) Systems Ground (Green) P-1 P-2 L1 Neutral (White) L2 Neutral (Gray) L3 Neutral (White/Gray) Systems Ground (Green) Page 12 of 12