IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

The filling level sensors are designed in accordance to the following standards

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85

IECEx Certificate of Conformity

Attachment to Certificate IECEx PTB X

IECEx Certificate of Conformity

IECEx Certificate of Conformity

TORRIX Magnetostrictive level sensor

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Certificate of Conformity

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

Type 4746 Electric or Pneumatic Limit Switch

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Ex m Solenoid Operator Type 0519

TB range of empty sheet metal enclosures. R S Sindair K~'

IECEx Certificate of Conformity

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

Reed sensor For bypass level indicators Model BLR

Solenoid coil for control in potentially explosive areas Type BZ

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX LABELLING FOR MOTORS AND GEAR UNITS

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Measuring insert for resistance thermometer Model TR10-A

Solenoid Operator 0516 / 1216

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Certificate of Conformity

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Rod thermostats (without immersion tube)

EXAMINATION CERTIFICATE

Instruction Manual. Ex-Time 40 / 50

Certificate of Compliance

Room thermostats type series TRM

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Solenoid Valves Type 3963

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Certificate of Conformity

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Product specification

K - Flow Meter with Float

Temperature sensor TE2

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Solenoid Operator 0513 / 1213

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Product specification

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Annex 1 to Certificate of Conformity IECEx KEM X, issue 4 Annex 1 to IECEx Test report NL/KEM/ExTR /04 Annex 1 to KEMA 02ATEX1090 X, issu

CERTIFICATE OF COMPLIANCE

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Capacitive level sensors CLS 23

Limit Switch Type 4747

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Product specification

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Safety Instructions Proline Promass 300

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

SATRON VT Pressure Transmitter

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

A good connection. International approvals.

Technical Data. Dimensions

I Ex-Safety switches I

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Certificate of Compliance

Terminal Boxes in Stainless Steel SLS**.T

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Differential pressure transmitter PASCAL Ci4 Delta P

Limit switch attachments DAPZ

Compact differential pressure switch Models DC, DCC

Ex PROFICIENCY TESTING PROGRAM

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Magnetic Switches for WEKA Visual Level Indicators Australian Version

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Direct-acting 3/2 way plunger valve

Flap-Type Flow Meter Prall

Mini pressure switch Stainless steel switch enclosure Model PXS

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Transcription:

IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing location (s): FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-11 : 2011 Edition: 6.0 IEC 60079-26 : 2006 Edition: 2 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in IECEx ATR: File Reference: DE/TUN/04/551164 04 YEX 551164 DE/TUN/ExTR12.0019/00 12 217 100332 DE/TUN/ExTR12.0019/01 14 217 139555

IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The level gauge type TORRIX Ex... or TORRIX Ex... SC... consists of a housing with the evaluating electronics, the sensor, the tube and float. The tube with the float is placed within the liquid. A permanent magnet, situated in the float, twists the sensor - a magnetostrictive wire. The evaluating electronics calculate the filling level from the running times of this mechanical shaft. The level gauge has to be supplied with intrinsically safe circuits. The data can be found in the "Attachment to IECEx TUN 04.0006X Issue 4". CONDITIONS OF CERTIFICATION: YES as shown below: 1. If titanium floats are used, care must be taken during the installation and the operation that these floats cannot cause any frictional and impact sparks. 2. The level gauge isn t marked with the permitted ambient temperature and the liquid temperature. The relation between the temperature class, the permitted ambient temperature (T a ) and the permitted liquid temperature (T F ) shows the instruction manual or in the "Attachment to IECEx TUN 04.0006X Issue 4".

IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue 1 and issue 2 were withdrawn. For this issue 4 the types TORRIX Ex HART, TORRIX Ex TAG and TORRIX Ex Flex were added. Further the internal electronic structure has been changed. Annex: Attachment to IECEx TUN 04.0006X Issue 4.pdf

TÜV NORD CERT GmbH Hanover Office Am TÜV 1 30519 Hannover Page 1 of 2 Attachment to IECEx TUN 04.0006X Issue 4 The permissible ambient temperature ranges as well as the medium temperature in dependence of the temperature class have to be taken from the following tables: TORRIX Ex and TORRIX Ex SC Use as EPL Ga apparatus Temperature class Ambient temperature range/medium temperature T1 to T4-20 C to +60 C The process pressure of the media has to be from 0.8 bar to 1.1 bar when potentially explosive mist air mixtures exist. If no potential explosive mixtures exist, the device may also be operated outside of this stated range according to the specification of the manufacturer. TORRIX Ex Use as EPL Ga/Gb apparatus T6-40 C to +40 C -20 C to +60 C T5-40 C to +55 C -20 C to +60 C T4 to T1-40 C to +85 C -20 C to +60 C The process pressure of the media has to be from 0.8 bar to 1.1 bar when potentially explosive mist air mixtures exist. If no potential explosive mixtures exist, the device may also be operated outside of this stated range according to the specification of the manufacturer. TORRIX Ex SC Use as EPL Ga/Gb apparatus T6-40 C to +50 C -20 C to +60 C T5-40 C to +65 C -20 C to +60 C T4 to T1-40 C to +75 C -20 C to +60 C The process pressure of the media has to be from 0.8 bar to 1.1 bar when potentially explosive mist air mixtures exist. If no potential explosive mixtures exist, the device may also be operated outside of this stated range according to the specification of the manufacturer. P17-F-021 03-10

TÜV NORD CERT GmbH Hanover Office Am TÜV 1 30519 Hannover Page 2 of 2 Attachment to IECEx TUN 04.0006X Issue 4 TORRIX Ex Use as EPL Gb apparatus T6-40 C to +40 C -40 C to +85 C T5-40 C to +55 C -40 C to +100 C T4-40 C to +85 C -40 C to +135 C T3-40 C to +85 C -40 C to +200 C T2-40 C to +85 C -40 C to +300 C T1-40 C to +85 C -40 C to +450 C TORRIX Ex SC Use as EPL Gb apparatus Electrical data T6-40 C to +50 C -40 C to +85 C T5-40 C to +65 C -40 C to +100 C T4-40 C to +75 C -40 C to +135 C T3-40 C to +75 C -40 C to +200 C T2-40 C to +75 C -40 C to +300 C T1-40 C to +75 C -40 C to +450 C Type TORRIX Ex Signal- and supply circuit (terminals +, -) Type TORRIX Ex SC Signal- and supply circuit (terminals +, -, A, B) in type of protection Intrinsic safety Ex ia IIC only for the connection to certified intrinsically safe circuits with the following maximum values: Maximum values: U i = 30 V I i = 200 ma P i = 1 W C i = 5 nf L i = 50 µh in type of protection Intrinsic safety Ex ia IIC only for the connection to certified intrinsically safe circuits with the following maximum values: Maximum values: U i = 15 V I i = 60 ma P i = 100 mw C i = 10 nf L i = 100 µh P17-F-021 03-10