RELIABLE AND EFFICIENT SYSTEMS

Similar documents
General Hand Tools (1 of 6)

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

3/12/2012 UNIT OBJECTIVES THE NEED FOR CALIBRATION SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

YELLOW JACKET. SuperEvac Vacuum Pump for Ammonia and NH 3 Systems. Operation and Maintenance Manual. Models and Table of Contents Page

HUDSON TECHNOLOGIES REFRIGERANTSIDE SOLUTIONS OTHER SERVICES PRODUCTS

11. Installation Instruction

Installation Instructions

Section 10 Chapter 17

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

1 Exam Prep. Air Conditioning "A", "B" and Mechanical Practice Exam 13 Drawings Attached

Troubleshooting guide for poor acceleration, black smoke, and flash code 39, SID 147, FMI 7 or 2

Installation, Start-Up and Service Instructions

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

SAMPLE PRODUCT SPECIFICATIONS

Vacuum Furnace Pumping Systems

6. Document tasks performed during visit and report any observations to the appropriate

Leak testing in the automotive industry. Applications for Component Manufacturing and Final Testing

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Induction, Cooling, & Exhaust. Aviation Maintenance Technology 111 B B

Propane Conversion Systems. Installation Instructions: 2S-LIFAN200TM 2S-LIFAN200FM 2S-LIFAN390TM 2S-LIFAN390FM

Operating Manual. High Performance Vacuum Pump Models and 15600

Hydraulic Power Supply and Motors Concept and Theory


POLAR TOUCH Smart wireless manifold probes

Models

CHAPTER 12 SERVICING. Section Title Page

VACUUM PUMP SERIES VP & VPC SINGLE - DUAL STAGE VACUUM PUMPS OPERATION MANUAL

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Engine Emission Control 6.7L Diesel

Automotive Air Conditioning Manifold Gauge Sets

TRANSFORMER OIL FILTRATION PLANT 6000 LPH CAPACITY TRANSFORMER OIL FILTRATION PLANT LPH CAPACITY

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070

2003 Mustang Workshop Manual

P0456-EVAP PURGE SYSTEM SMALL LEAK

VRS & VRSH Twin Screw Compressor

t EVAPORATOR PRESSURE REGULATING VALVES

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

MACHINES RECOVERY. 99 Washington Street Melrose, MA Phone Toll Free SYSTEMS SUPEREVAC

Mainstream Engineering Corporation Rockledge, Florida 32955

4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps

Fluid Distribution Header

.6 Liter (20 oz.) Touch Up Spray Gun 126-A

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

P0456-EVAP PURGE SYSTEM SMALL LEAK

P70, P72, and P170 Controls for Low Pressure Applications

TRICENTRIC VALVES TRICENTRIC METAL SEATED BUTTERFLY VALVE TRIPLE OFFSET

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Installation Instructions

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

348002K/348012K Manifold Block Style Service Manual 12/2000

9/28/2018. Refrigeration compressor operation, maintenance and safety

2015 F-250, 350, 450, 550 Super Duty DESCRIPTION AND OPERATION Procedure revision date: 04/28/2016. Climate Control System

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Retrofit Crankcase Ventilation for Diesel Engines

DID YOU KNOW THIS HOLE COULD BE COSTING YOUR COMPANY MORE THAN $12,000 ANNUALLY?

Evaporative Emission Control System Operation Description (Enhanced)

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

FILTER DRIERS - SPORLAN

Micro Diaphragm Pumps (air/gas)

BOILER PM & INSPECTION

Secondary Coolant 301

Refrigerant Oil Calculation during Compressor Replacement

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

VPC Series 18VDC CORDLESS VACUUM PUMP OPERATION MANUAL

PT-516 Pumping Trap Installation and Maintenance

HCFCs Refrigeration Retrofit Guidelines

FABER BURNER ROUTINE MAINTENANCE

Instruction Manual for Direct-Drive Oil Sealed Rotary Vacuum Pump

2014 Buick Encore. Fig. 2: Replacing Measured Compressor Oil Courtesy of GENERAL MOTORS COMPANY

Protector Glove Boxes.

Si-RM3 Smart wireless manifold probes

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H6DO

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS

Pro-Set LDA1000H Refrigerant Leak Detector

Evaporative Emission Control System Operation Description

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

Pre-Wired and Pre-Piped

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

PRESSURE TEST. Checks for leaks at fuel line, inlet needle, & fuel pump body Hook tester up to tank inlet line. Pump tester up to 10psi (.

Protector Controlled Atmosphere Glove Boxes

Injector. General Information CAUTION. Use only the specified injector for the engine.

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL

DESCRIPTION AND OPERATION

Module 2:Genesis and Mechanism of Formation of Engine Emissions Lecture 3: Introduction to Pollutant Formation POLLUTANT FORMATION

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H4DOTC

Sea Pro FH240 Series Filter/Separator Installation Instructions

Miniature Pneumatic Solenoid Valve

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H4SO

Refrigerant Changeover Guidelines. Leading the Industry with Environmentally Responsible Refrigerant Solutions

San Joaquin Valley Unified Air Pollution Control District Permit Services Division

February 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM

General Information. Note : The aftertreatment DOC is integrated into the inlet of the exhaust aftertreatment system. WARNING

SLOPE INDICATOR Geotechnical Instruments

LeakTamer. with UltraTraceUV Dye Technology. Operator s Manual

TECHNICAL SUPPORT MANUAL Coils for Manufactured Housing EMA2X, EMA4X

DIM Heating and Air Conditioning

Sea Pro FH240 Series Filter/Separator Installation Instructions

Transcription:

RELIABLE AND EFFICIENT SYSTEMS Systems must be leak-free as possible All systems leak Piping materials are slightly porous Very small leaks are not detectable and do not affect system efficiency Some systems are critically charged Leak tests must be performed on systems

STANDING PRESSURE TEST Visually inspect the newly assembled system Solder joints should have no gaps Flanged and threaded connections should be tight Control valves should be installed properly All service valve covers should be in place

PERFORMING A STANDING PRESSURE TEST Pressurize the system with dry nitrogen to a pressure no higher than the lowest system test pressure Allow the system to rest for 5 minutes Mark the needle positions on the gage manifold Allow the system to rest for as long as practical Monitor gage needle position

LEAK DETECTING METHODS Audible leaks are large and relatively easy to locate Halide Leak Detector Ultrasonic Leak Detector Ultraviolet Leak Detectors Electronic Leak Detectors

WHEN A LEAK IS DETECTED, THE FLAME COLOR CHANGES HALIDE LEAK DETECTOR

The sound of escaping gas can be heard through the headphones ULTRASONIC LEAK DETECTOR

Ultraviolet dye in the system glows at the point of leak when viewed under ultraviolet light ULTRAVIOLET LEAK DETECTOR

Beeping frequency increases when a leak is detected ELECTRONIC LEAK DETECTOR

LEAK DETECTING TIPS Newly installed systems should be leak tested with a standing pressure test The system must be evacuated to required vacuum levels Refrigerant/nitrogen mixes cannot be recovered Visual inspection for oil and dirt spots Leaks can be caused by vibration or temperature Leak check gage ports prior to gage installation

REPAIRING LEAKS EPA guidelines: Systems that do not require repair Systems with less than 50 lbs of refrigerant Some industrial/commercial systems with more than 50 lbs of refrigerant and a leak rate less than 35% per year Comfort cooling chillers with a leak rate of less than 15% per year Most residential systems

PURPOSE OF SYSTEM EVACUATION Air contains oxygen, nitrogen, hydrogen, water vapor Nitrogen is a non-condensable gas Non-condensables will cause a rise in the system s operating head pressure Oxygen, hydrogen, and water vapor cause chemical reactions in the system Produces acids that deteriorate system components and can cause copper plating

PURPOSE OF SYSTEM EVACUATION Chemical combinations create hydrofluoric or hydrochloric acids Evacuation = degassing + dehydration Moisture + acid + oil = sludge Sludge can cause system components to become plugged Proper evacuation can eliminate the formation of acid and sludge

THEORY INVOLVED WITH EVACUATION Pulling a vacuum lowers the pressure in a system below atmospheric Atmospheric pressure = 14.696 psia Psia = atmospheric pressure + gage pressure (psig) Pulling a vacuum removes non-condensable gases from a system Systems should be evacuated from the high and low pressure sides of the system

MEASURING A VACUUM 1 micron = 1/1,000 of a millimeter Hg 1,000 microns = 1 mm Hg 1 micron = 1/25,400 in. Best methods to measure Electronic (thermistor) vacuum gage Analog, digital, or light-emitting diode (LED) U-tube manometer Should reach at least 250 microns if there are no leaks in the system

THE VACUUM GAGE Power switch Hose to system Vacuum indicating LEDs Cap

THE VACUUM PUMP Two-stage vacuum pumps produce the lowest vacuum EPA mandates systems reach at least 500 microns during evacuation Very low vacuums cause moisture inside a sealed system to boil to a vapor which is then removed by the pump and released to the atmosphere

THE VACUUM PUMP Vacuum pump inlet Oil sight glass

DEEP VACUUMS Measured in the 250- to 50-micron range Once proper micron levels are reached, the vacuum pump is valved off When system pressure is reduced to the required vacuum level and remains constant, no non-condensable gas or moisture is left in the system

LEAK DETECTION WHILE IN A VACUUM Checking for a leak in system by watching to see if the pressure rises on a vacuum gage is not a recommended leak-test procedure If there is a leak during the above-mentioned problem, air is allowed to enter the system This method only proves that the system will not leak under a pressure difference of 14.696 (atmospheric pressure)

GENERAL EVACUATION PROCEDURES Cold trap Do not start a hermetic compressor while it is in a deep vacuum Applying heat to the compressor will assist in removing water that may be trapped under the oil Gage manifolds with large valve ports and hoses help speed the evacuation process Schrader stem depressors can be removed from gage hoses to reduce evacuation time

SYSTEMS WITH SCHRADER VALVES Take longer to evacuate than systems with service valves Field service valves are used to replace Schrader valve stems while the system is under pressure Schrader valve caps should be put back on the valve after service

GAGE MANIFOLD HOSES AND SYSTEM VALVES Hoses can have pinhole leaks and slow down the evacuation process Using copper tubing for the gage lines will help eliminate evacuation problems Check system valves to verify they are open before evacuation Closed valves can trap air in the system

USING DRY NITROGEN Sweeping dry nitrogen through a sealed system Helps keep the atmosphere out of the system Helps clean the piping of the system Do not pressurize the system with pressures that are above the system s test pressures Never start a system that is pressurized with nitrogen

CLEANING A DIRTY SYSTEM Formation of acid, soot and sludge Created by heat that causes refrigerant and oil to break down Cannot be removed from a system with a vacuum pump Fumes can be toxic Safety goggles and gloves should be worn