Load & Lock Cremators

Similar documents
GeniSys 24V. Model Advanced 24 Vdc Burner Control. Description / Applications

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

# Traction Control Window Switch

SUNDOWN Operation. & Parts Manual. for Box Blade Models BB15-48, 60 BB20-48, 60, 72 BB30-60, 72, 84, & 96

User Guide IGD Series

HVF110, 210, 310, 410HD

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

CRD610 Automatic Fitting Inserter

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

OPERATIONS MANUAL MODEL MT-500

Operator s Safety and Service Manual

Natural Gas Conversion Instructions for

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Installation manual. Replacement front sway bar end link Dodge Ram Dodge Ram 1500 Part # 30927

Smith & Hawken Propane Tank Cover dpci # stock # ZAZ15200T

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Power Inverter 400 MW Owner s Manual

COMPRESSED AIR LOADER MODEL: AL-1

TFL Gas Log Lighter (TFLGLL)

Operator s Manual. Go Galvanized! YOU'RE ALWAYS AHEAD...WITH A MODERN BEHIND.

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

User s Manual and Operating Instructions

MaxLite LED UTILITY WRAP FIXTURES

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Air Curtain. Installation, Operating and Maintenance Instructions

Installation & Operators Manual

D Instructions/Parts. Siphon Feed Detail Spray Gun D

ELECTRONIC FIREPLACE DAMPER

Go Power! Manual. GP-Smart Charger

PROwatt 150 DC to AC Power Inverter. Owner s Guide

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CRD600 Automatic Fitting Inserter

Owner s Manual & Safety Instructions

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

RU BMS Power Supply and Battery Management System Owners Guide

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

Power. On Your Terms.

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

INSTALLATION AND OPERATING

Roller Door Operator

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Installation Precautions. Use Precautions. Specifications

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

ROTARY BRUSH CUTTERS THE LEADER OF THE PACK OWNER/OPERATOR SAFETY & INSTRUCTION MANUAL

CAUTION: Read manual carefully for proper procedures and operation.

EMISSION CONTROL WARRANTY STATEMENT

Positive Displacement Pump

HALLMARK INDUSTRIES INC

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

A2P Single Phase Automatic Industrial Battery Charger

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Replacement Parts. Screw-on alligator clip 4 Flex probe adapter SST-13 P3. Blow molded case User Guide

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

QUALITY MISTING PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

LEV/Wn Building A Connected World

ESE Series Cast Iron Sewage Pumps

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

10 Year Limited Warranty

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

5 Grinder-Vac and Shroud Kit Operating Manual

Operating and Installation Instructions

DUAL PURPOSE DIAGNOSTIC LEAK DETECTOR

Automatic Emergency Light

Please begin by checking that you have received all of the parts that come with your kit.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Manual Operated Floor Jack

INSTALLATION AND OPERATING MANUAL

Power Float Manifold. Installation and Operations Manual Module 11A

Owner s Manual GLASSLINED PUMP TANK

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

OPERATIONS MANUAL LEVER CHAIN HOIST

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

230VAC Power Inverter 400W Owner s Manual

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

ProFlo FatBoy

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

StormPro BA Series Sump Pump

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

2SHE Series Direct-Drive Shutter Fans

900 PEAK AMP PORTABLE JUMP STARTER

E Series CE Approved Intermittent Pilot Ignition Control

IMPORTANT SAFETY INSTRUCTIONS

Gauge Adapter Instruction Manual

RF6 / RF10 / RF18 Installation Instructions

OPERATOR S MANUAL. 20-bu 3-Point Hitch Material Collection System. LP65048 Supplier ST /07/2017 English. North American Edition Printed in USA

OWNER S MANUAL: Model # JGSBSEAR Searing Burner Station

ATK LIMITED WARRANTY FOR REMANUFACTURED ENGINES

60V RECHARGEABLE LITHIUM-ION BATTERY

The Da-Lite Difference.

Transcription:

Earth Smart Solutions Load & Lock Cremators Instruction Manual Product/Service Information Installer/Service Tech This manual must be used only by a qualified service technician. Failure to comply with this or other requirements in this manual could result in severe personal injury, death or substantial property damage. Refer to the burners information booklet for information regarding operation of the burner. Date: 08/14/07

Page 2 Table of Contents Warning & Safety Reminder 3 Inspection /install fuel supply 3 General Guidelines 4 Checkout Procedures 4 Checklist 4 Train the user 5 User care and maintenance 5 Start-up & operation 5 General Maintenance 6 Diesel Burner Setup Information 6-8 LP/NG Burner Setup Information 9-10 Troubleshooting 11 Warranty Information 12

Page 3 Warning & Safety Reminder A qualified service technician must install burner/cremator Manufacturer or Distributor does not install the Cremator. Consequently, it is the responsibility of the owner and user to install, maintain, and operate this machine in such a manner as to comply with the Occupational Safety and Health Act (OSHA), State and Local Laws, Ordinances and Safety Codes. In order to avoid an unsafe or hazardous condition this machine must be installed and operated in accordance with the following minimum provisions. Cremator doors must be kept closed while operating. Keep children out of reach of cremator and always keep doors closed when not in use. Incinerator must be installed on solid and level surface Example: Poured concrete surface or concrete slab. Keep out foreign materials such as metal, stones, wood, etc. Do not attempt to burn wood, trash, rubber tires, plastics, etc. Do not overload cremator. About 3 from top of tub After starting do not attempt to touch unit. Stay a safe distance away. Keep cremator at least 25 feet away from any building/ structure. Inspect / Install fuel supply Caution: Inspect the fuel supply system. Ensure that the fuel lines are correctly sized and installed and that the fuel flow is unobstructed, the fuel tank is clean and proper fuel is supplied. Failure to supply a reliable fuel flow could result in loss of heat and potential severe equipment damage. Earth Smart Solutions

Page 4 Warning: Use only fuels recommended for your burner/cremator General guidelines When installing fuel lines use a continuous run of heavy-wall copper tubing when possible. Check all connections and joints to ensure they are air-tight. Use flare fittings. Do not attempt to use compression fittings on copper tubing. Never use pipe sealing tape. Install a large capacity fuel filter with oil burners. Oil tank should be at the same level as the burner or slightly higher. Perform checkout procedures Warning: Should overheating or an emergency occur, immediately: Shut off fuel supply line valve. Determine proper response before attempting start-up. Checklist Burner/cremator installed per instruction manuals? Burner/cremator installed per applicable codes? Installation site is solid, level and free from foreign materials? Fuel supply lines are in good condition and sized/designed correctly? Fuel tank is full and all fuel line valves are open? Wiring installed per burner/cremator instructions? Burner/cremator and all components inspected and in good condition?

Page 5 Warning: Turn off power to the burner/cremator when servicing. Failure to comply could result in severe personal injury, death, or substantial property damage. Train the user Train the user to operate the burner/cremator under normal conditions. Explain procedure to shut down burner/cremator when required. Verify the user is aware of all procedures specified in all of the manuals (not limited to this instructions manual). Verify user will not store or use combustible liquids or materials or contaminants in the vicinity of the burner/ cremator. Explain proper loading of cremator. Do not load while hot. Do not dump heavy loads from a loader bucket onto grating system. Do not fill above the end grate. Warning: Do not start burner if the combustion chamber contains oil or any fuel vapors.. Start up & Operation 1. Fill cremator with remains, NO higher than the top of the end grate. DO NOT over fill cremator. 2. Pull lid forward, lock lid down with cam locks on each end. Ensure a tight seal. 3. Check fuel supply and proper fuel flow. 4. Check power supply. 5. Check under grates there is no obstruction. 6. Set timer to the indicated hour run time (80-120 pounds per hour). Earth Smart Solutions

General Maintenance Page 6 Keep the area around the burner/cremator clear and free from combustible vapors, liquids, and foreign objects. Clean ash chamber before every burn. Verify that the chimney opening is unobstructed.. Inspect fuel supply system to ensure proper fuel flow. Do not drop heavy loads on grates. Do not open cremator while hot. Disconnect the electrical supply to the burner/cremator before attempting to service to avoid electrical shock or possible injury. Burner/cremator parts can be extremely hot. Allow all parts to cool before attempting to handle or service to avoid potential of severe burns. Notice: For other than routine maintenance, contact a qualified service technician. Notice: Install this burner/cremator in accordance with all local codes and authorities take precedence over the general instructions provided in this manual. 1500

Page 7 F-5 and F-10 Burner Setup and Instruction AB All Diesel Afterburners come with a.75 nozzle size F-5 Burner All LL700 come with a 1.25 nozzle size F-5 Burner All LL900 come with a 2.00 nozzle size and a F-10 Burner All LL1500 come with a 2.50 nozzle size and a F-15 Burner An external fuel filter is REQUIRED. The filter should be changed at least once a year also the strainer inside the fuel pump should be cleaned. 700 900

Page 8 Ensure that the burner is installed flush or at least 1/4 inside of the burner door. Earth Smart Solutions

Page 9 G-400 G-200 Note: Piping to LP/NG burners should be a minimum of 3/4

Page 10 TROUBLESHOOTING Symptom Cause (s) Solution (s) SbEr Sensor break error Replace Temperature Probe and check wires are connected on back or computer LLEr HLEr Process display beyond The low range set point Process display beyond The high range set point Change out computer Change out computer AHEr Analog hybrid module damage Change out computer AtEr Incorrect operation of auto tune Procedure Prop. Band set to 0 Change out computer oper CSEr Manual mode is not allowable for an ON-OFF control system Check sum error, values in memory may have changed accidentally Earth Smart Solutions Change out computer Change out computer

Page 11 TROUBLESHOOTING Initial Checklist: 1. Ensure computer screen is illuminated. 2. Check Turbo Fan on lid is running. If not check the in-line fuse in control box. 3. Burner does not run but Turbo Fan and Computer operate correctly. 4. Check green light is illuminated on left side of computer press reset button on burner control box. 5. Check wires going below control box are installed correctly White wire to N, Black wire to L, Green wire to Ground. Note: Propane burner must have a minimum of 118vac and be grounded properly. 6. Still not working check wire from Pin 3 of Relay to L on Burner. Burner fan runs all the time but burner does not ignite. Burner does not go into lockout. 1. Check the photo-eye (Diesel) Ground wire (LP/NG) making sure it is clean and making contact. Wipe any residue if needed. 2. Check Control Box is mounted flush and that the photo-eye is not seeing light. Still bad change Control Box. Burner runs but will not stayed ignited 1. Ensure electrodes are set correctly according to burner booklet. 2. Ensure air damper is set correctly. 3. Check fuel filter and fuel pump screen (Diesel) is not clogged. 4. Check fuel nozzle (Diesel) is clean 3. Check the polarity is correct (LP/NG) 4. Check Ground wire on ionization probe is secure Burner does not ignite and goes into lockout 1. Press your Reset Button 2. Ensure fuel pump has been bled and purged (Diesel) 2. Ensure you have the correct manifold pressure (LP/NG) 3. Check control box is mounted flush and is good. 4. Ensure there is no light getting to the burner. (Diesel) 5. Check to see if Diesel is spraying out of the nozzle. IF THIS DOES NOT CORRECT THE PROBLEM CONTACT YOUR DEALER OR EARTH SMART SOLUTIONS INC AT: (903) 638-0026 or email kalvin@earthsmartsolutions.com

Page 12 Load & Lock Cremators Manufacture s Warranty Load & Lock Cremators here in after referred to as a Manufacture warrants each new cremator to be free from defects in material and workmanship under normal use from the original date of sale. Base upon the following time periods Steel for 1 year. Refractory for 6 months. Electrical for 90 days. All Grates for 90 days. This warranty is expressly in lieu of all other warranties and representations expressed or implied, and all other obligations or liabilities on the part of the manufacturer. Manufacture s liability and obligation is limited to the repair or replacement of the product at the manufacturer s option provided the purchaser returns the claimed defective product to the Manufacturer. With transportation charges prepaid, and an examination by the manufacturer discloses the product is defective before replacement will be shipped. This warranty does not cover said product, which has been repaired or altered outside of the factory of the Manufacturer in anyway so as to in the judgment of the Manufacturer affect the stability, reliability, or performance of the product. Failure caused by accident, misuse, negligence, tampering, improperly attached or improper maintenance will void warranty. The warranty excludes any and all liability or incidental damages. This warranty gives you specific rights providing said product is put to its proper designed use. Important: Warranty card must be completely filled out and returned to Manufacturer with in 15 days of purchase or warranty will be void. Earth Smart Solutions

Page 13 Warranty Card EARTH SMART SOLUTIONS Date of sale Installer/service tech check off the following with the user and fill out and return remainder of Warranty card. User trained in burner/cremator normal operation Installer Purchaser User has been explained proper shutdown procedures when required. Verify the user is aware of all burner/ cremator procedures specified in all manuals. User is to never attempt to use gasoline Load & Lock Warranty Card Date of Sale: Purchaser: Unit size: Phone Number: Serial #: Location: Fuel source: Return Warranty card to: Earth Smart Solutions Installer: Box 1042 Hawkins, TX 75765 (903) 638-0026

Other Solutions for your farm Odor Control Soil Remediation Feed Enhancement Lagoon Management Litter Treatment Water Quality Improvement Ammonia Control Phosphorus Reduction Algae Control in Ponds and Lakes All Natural Insecticide Knockout Insecticide Knockout Odor Control Ionic Fission Cell Aquazyme 777 Aquazyme 700 Dragon Fire Coatings Load & Lock Incinerators Vigilant line Diamond Blue

Do you want more money back? If you mail this in or call in with your promo code, you can receive a referral bonus to anyone who purchases any Load & Lock and your name. Also, you can receive a discount on any or our other product line. P.O. Box 1042 Code#ESSP0807-1 Hawkins, TX 75765 Www.earthsmartsolutions.com