System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

Similar documents
1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

1 Safety instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

Power enhancement for the dimmers contained in the reference list (see section Technical

1 Safety instructions. 2 Device components. System Blind control insert with auxiliary input

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Figure 1: Device components

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Operating Instructions. Tronic Dimmer

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Command and signalling E 250, E 259 selection table

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Operating Instructions Electronic transformers for lowvoltage halogen lamps

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

Modular contactor for installation into distribution boards

CI-TI Contactors and motor starters Types CI 61 - CI 98

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

BETA Switching Switching Devices

Multi-function. Mono-function 1 NO (SPST-NO)

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Local Control Network - building controls in perfection

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

CI-TI Contactors and Motor Starters Type CI 6-50

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

Emergency lighting units EM powerled

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Miniature Circuit-Breakers (MCBs)

Contactor Types CI 61-98

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Emergency lighting units EM powerled

KD LV Motor Protection Relay

4 - Miniature controls

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Power Electronics. Motor brake relay GA 9031 ministop

Industrial Contactors CTX 3 3P 185A - 800A

Emergency lighting units EM powerled

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

W Datasheet: DIN Rail Contactors, series AMPARO

Emergency lighting units EM powerled

A LIFETIME OF LIGHT. Magnetic Ballasts (A2) plus Electronic Starter

Installation & User Instructions

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Thermal Circuit Breaker 3120-F...

TURBOTRONIK NT 151/361

Technical Manual Electrical Power Supply System T4002

With magnetic fixing With ON/OFF switch

Emergency lighting units EM powerled

Emergency lighting units EM powerled

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Emergency lighting units EM powerled

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Miniature Circuit-Breakers (MCBs)

Pulsar EXtreme CLA 1500C

Air Flow Controller M1compact Type-Summary FKM 130

Einschaltverzögerung. Schaltwert 1 Schaltwert 2 Schaltwert 3. Schaltwerte in Lux. Wiedereinschaltsperre x 20 x 1 Ein Aus

BETA Switching Switches and Light Indicators

Switchgear for Luminaires

DELTA i-system 11/1 1/1. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/12 Outlets. 1/17 International plug-and-socket devices

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Emergency lighting units EM series

Electronic Ballast EVG 2000-T

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Electronic Circuit Breaker ESS20-0..

Domae. The right solution for distribution boards

Effective discrimination of protective devices

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Mini Contactors CI 4-

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Operating instructions Bedienungsanleitung Mode d emploi

Installation Contactors RIC, RAC

Electronic timers CT-E range Selection and ordering details

EPS/ELA-Series User Manual EPS/ELA 250W

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Installation Instructions

Emergency lighting units EM powerled

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

SIRIUS 3RU2 Thermal Overload Relays

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Overloadrelay,10-16A,1N/O+1N/C. Articleno

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Electronic Circuit Breaker ESS20

Training & Didactic Systems. Fundamentals of Electrical Engineering

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Thermal Overcurrent Circuit Breaker 3120-F...

Operating Instructions Type MPT 53

Transcription:

DRA automatic stairway lighting Order-No. : 0821 00 Impulse insert Order-No. : 0336 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load. Danger of electric shock. Automatic RMD is not suitable for disconnection from supply voltage. Do not connect automatic RMDs in parallel. Damage to devices may result. Danger of electric shock. Do not operate the insert without a cover. Use pulse insert exclusively for activation of the automatic RMD. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Automatic RMD (Figure 1) Figure 1 (1) Automatic RMD (2) Adjuster for run-on time (3) LED on/off: Light switched on/off (4) Adjuster for operating mode 32549222 10499177 I00 28.09.2011 1/7

Pulse insert (Figure 2) Figure 2 (5) Up insert (6) Frame (7) Motion detector cover (8) Screw terminals i Optionally it is also possible to use a presence detector cover or pushbutton cover. 3 Function Intended use of automatic RMD - Manual or automatic switching of light in stairways - Installation in distribution boxes on DIN rail according to EN 60715 - Switch-on via pulse insert or installation buttons Product characteristics of the automatic RMD - Adjustable run-on time - Electronic overload protection for the control input - Four different operating modes can be set: Automatic function without switch-off pre-warning Automatic function with switch-off pre-warning Light switched on continuously Light switched off continuously Intended use of pulse insert - Manual or automatic switch-on of an automatic RMD - Installation in appliance box to DIN 49073 - Operation with suitable cover Product characteristics of pulse insert - Manual switching in combination with pushbutton cover - Automatic switching in combination with motion detector cover - Insert designed with 2-wire technology Automatic switching of light The pulse insert is combined with a motion detector cover. As soon as the brightness drops below a value set on the motion detector cover and motions are detected, the pulse insert sends a switch-on signal cyclically to the automatic RMD. The latter switches on the light for the set run-on time. After the run-on time has elapsed, the automatic RMD switches the light off. 32549222 10499177 I00 28.09.2011 2/7

After switch-off, pulse inserts with motion detector covers will not detect any motions for approx. 3 seconds. 4 Operation Switching the light on manually An automatic function is active on the automatic RMD, adjuster (4) is set to position or. o Press pushbutton cover on pulse insert or installation button. Light is switched on independently of the brightness for the run-on time. LED (3) on automatic stairway light switch lights up. Setting operating mode on automatic RMD Automatic function without switch-off pre-warning. The lighting is switched off after the runon time elapses. Automatic function with switch-off pre-warning. After the run-on time elapses, the lighting is not switched off immediately, but rather only after flashing three times at intervals of 10 seconds. i In this operating mode, the service life of the relay contact may be reduced when fluorescent lamps or energy-saving lamps are used. Light is switched on continuously. ƒ Light switched off continuously. o Turn adjuster (4) for the operating mode to the desired position. i Any operating mode switch present on a motion detector cover has no function. Setting the run-on time Adjustment range from approx. 10 seconds (lower end stop) to approx. 15 minutes (upper end stop). o Set adjuster (2) on automatic RMD to the desired time. i In the case of automatic function with prewarning the set run-on time is extended by approx. 30 seconds. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment. Fitting and connection The automatic RMD can be used for a 3-conductor circuit (Figure 3) or a 4-conductor circuit (Figure 4). The 4-conductor circuit has the advantage that an additional luminaire can be switched separately. 32549222 10499177 I00 28.09.2011 3/7

Figure 3: Connection diagram for 3-conductor circuit Figure 4: Connection diagram for 4-conductor circuit (1) Automatic RMD (9) Pulse insert is with motion detector cover or pushbutton cover (10) Installation button, NO contact CAUTION! Overvoltage when connected two external conductors. Destruction of the automatic RMD. Connect to only a single phase. Do not operate multiple automatic RMDs next to each other. Avoid having heat sources, e.g. RMD dimmers, in the immediate vicinity of the automatic RMD. Ensure sufficient heat dissipation. 32549222 10499177 I00 28.09.2011 4/7

i On control input A1 of the automatic RMD the aggregate current load must not exceed 40 ma. To determine the current load, add together the current consumption of all connected pulse inserter and lighting elements of the installation buttons. Example: 6 x pulse inserts: 6 x 2.5 ma = 15 ma Available current for lighting elements: 40 ma - 15 ma = 25 ma Number of lighting elements at 0.9 ma per element: 25 ma / 0.9 ma = 27.7 Thus 27 illuminated installation buttons can be connected. The number of unilluminated installation buttons is not limited. o Mount automatic RMD on DIN rail. o Connect automatic RMD, pulse insert 9) and installation button according to connection diagram (Figure 3) or (Figure 4). o Install pulse insert in an appliance box, terminals must be at the bottom. o Mount the installation button in an appliance box. o Mount frame and cover. 5.2 Commissioning Setting the automatic RMD o Set operating mode on automatic RMD (see "Operation"). o Set run-on time on automatic RMD (see "Operation"). o Switch on mains voltage. Setting the motion detector cover DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before working on the device, disconnect all the corresponding miniature circuit breakers. Cover up live parts in the working environment. i For a function test with motion detector cover, set the motion detector cover to brightnessindependent switching (see instructions for the cover). o Performing a function test. o If necessary, adjust the sensitivity on the motion detector cover (see instructions for the cover). o Set brightness value on the motion detector cover (see instructions for the cover). o For motion detector covers that have short-time operation, set short-time operation (see instructions for the cover). 6 Appendix 6.1 Technical data DRA automatic stairway lighting, Order-No. 0821 00 Rated voltage AC 230 V ~ Mains frequency 50 Hz Power consumption approx. 1 W Ambient temperature +5... +45 C Switch-off delay approx. 10 s... 15 min Tolerance ± 20 % Control input A1 Current carrying capacity 40 ma Switching voltage AC 250 V ~ Switching current Ohmic 16 A 32549222 10499177 I00 28.09.2011 5/7

Switch-on current 20 ms Minimum switching current AC Contact type Connected load Incandescent lamps HV halogen lamps Fluorescent lamps, parallel compensated Fluorescent lamps, uncompensated Fluorescent lamps, duo circuit Tronic transformers Inductive transformers Electronic ballast Connection Single stranded finely stranded with conductor sleeve finely stranded without conductor sleeve Fitting width Total length power cable Total length of control cable max. 165 A 100 ma µ contact 2300 W 2300 W 920 VA 1200 VA 2300 VA (140 µf) 1500 W 1000 VA Type-dependent 1.5... 4 mm² 0.5... 2.5 mm² 0.75... 4 mm² 18 mm / 1 modules max. 100 m max. 100 m Impulse insert, Order-No. 0336 00 Rated voltage AC 230 V ~ Mains frequency 50 Hz Power consumption approx. 0.5 W Current consumption approx. 2.5 ma Ambient temperature +5... +35 C pulse duration approx. 60 ms pulse stop approx. 6 s Connection Single stranded max. 4 mm² 6.2 Troubleshooting Light switches on but not off Cause 1: The overload protection of the control input has tripped on the automatic RMD, because too many pulse inserts or illuminated installation buttons are connected. Reduce number of connected devices. Cause 2: The overload protection of the control input has tripped on the automatic RMD, because the automatic RMD has been installed too close to an external heat source, e.g. a dimmer. Check installation situation, ensure better cooling. Light does not switch off. Cause: Constant motion in detection area of motion detector cover. Check installation situation of motion detector cover. Reduce sensitivity on the motion detector cover (see instructions for the cover). 6.3 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 32549222 10499177 I00 28.09.2011 6/7

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 32549222 10499177 I00 28.09.2011 7/7