Wet Rated Batten LED Luminaire

Similar documents
WARNING / AVERTISSEMENT

Horticulture Batten LED Luminaire

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Lumination TM LED Luminaire LUR Series

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Specification Grade Contemporary Wall Mount/Technical Installation Data

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTALLATION INSTRUCTION Bollard Light 12V

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

WASP-P PRESSURE SENSOR

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

V9961 V9961

INSTALLATION INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

P

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

UB-2 2 Universal Button


Y9854. fisher-price.com

X0056. fisher-price.com

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

Press the buttons for fun sounds and music! fisher-price.com

Powerware Vdc Extended Battery Cabinet User s Guide.

Captivate Illuminated Mirror Light


W1392. fisher-price.com

INSTALLATION INSTRUCTIONS

CHARGING FOLIO. for iphone 6 USER GUIDE

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

Cable Cubby 650 UT Installation Guide

T

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

BFK51 CFD40 CHM41. fisher-price.com

Parent s Guide. This guide contains important information. Please keep it for future reference US

Cable Cubby 1202 and 1402 Installation Guide

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

GETTING STARTED WITH IN-WALL DIMMER SWITCH

LAL SERIES LED LUMINAIRE

INSTALLATION GUIDE Works in double and single ended wiring.

LED Recessed Troffer Retrofit Kit

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. Ride. Sit. Walk. fisher-price.com

Installation Instructions CRAFT M/L

poollux Power plx-pw60 & plx-pw100

EMERY SKY SUSPENDED LED LUMINAIRE

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

R

P Volt Charger Each sold separately and subject to availability.

Lumination TM LED Luminaire (IS Series)

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

HOMELINK DOOR OPENER KIT

Spun Bay Installation Standard Version (non dimmable), Hook Mount

PRODUCT DESCRIPTION SPECIFICATIONS

W

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

T Overhead Gym. Tummy Time Fun. On-the-Go Fun

W3599

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

T6339. Remove the mobile from the hub and clip to a stroller for on-the-go entertainment!

VR44-MU-xxx-8yy-xxxxA

INSTALLATION DATA ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

TM-11x1 Series Room Temperature Module

V-D2425 and V-D2440 Digital Clock

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

M9109 Series Electric Non-spring Return Actuators

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

INSTRUCTION BOOK FOR. Tensioned Advantage Electrol

WARNING. To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym.

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

LED DayLite Micro. User Guide Ver

Letter Band Phonics Jam

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION DATA ETC SINGLE Stage

Parent s Guide Mickey Ramps Fun House

Touchstone TB130 DC Output UPS

Tattle-Tapet. Operator s Guide. Application System Model 611. Read all Safety Information Before Using this Product

BFT56 CKB84. fisher-price.com. Keep this instruction sheet for future reference, as it contains important information.

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

Transcription:

Installation Guide Wet Rated Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. The electrical supply for each luminaire must always be connected to the male connector. Not to be submerged or used in a marine environment. RISK OF FIRE Follow all NEC and local codes. RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l alimentation avant l inspection, l installation ou le déplacement. L alimentation électrique pour chacun des luminaires doit toujours être branché du côté mâle de la prise. Ne pas submerger ou installer dans un environnement marin. RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux. Save These Instructions The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer, his service agent or a qualified specialist. Prepare Electrical Wiring Electrical Requirements Suitable for dry, damp and wet locations. Followall National Electric Codes (NEC) and local codes. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A) Note: Thisequipmenthas been tested and found to comply with the limits for a ClassA digital device, pursuant to part 15 of the FCCRules. Theselimits are designed to provide reasonable protection against harmful interference when the equipmentis operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipmentin a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at hisown expense. 1

Product Length Mounting Surface C B A A B C Length of lamp Length including Length of additional with connectors leader cable lamp in series ft. 4.7 6.7 cm 7.7 70.4 cm 3.9 60.6 cm 4ft. 47 119.4 cm 50 17.1 cm 46. 117.3 cm 8ft. 91 31.5 cm 94. 39. cm 90.3 9.4 cm Tools Required Components Required 1 1 3 3 4 5 6 7 8 1 3 Wire stripper/cutter Screwdriver Cordless drill with driver bit 1 3 4 5 Current LED Batten fixtures Leader cable (96440) Standard mounting clips (88818) Slim mounting clips (10734) #10 (M5) self-tapping flathead screws 6 7 8 UL approved 18-14 AWG (0.8-.08 mm ) wire connectors or in-line splice connectors End cap for connectors Jumper cable (96441: 4 in./610 mm long)

METHOD 1 Installation Steps: Single Luminaire Installations Planning first: Luminaires must only be mounted using Currrent s standard and slim mounting clips (see Components Required on page ) Align using chalk line, laser projector or similar Rotate and Push 1 Secure each luminaire mounting clip to a rigid flat mounting surface using two #10 (MS) self-tapping flathead screws along the intended run of luminaire. To avoid stress and damage to luminaire the entire mounting surface should be flat and the mounting clips be properly aligned. Refer to table on page 7 for required number of mounting clips per luminaire. Press the first luminaire into its mounting clips so that the male connector is oriented towards the intended electrical supply. TIP: Align luminaire on one side of the mounting clips; then rotate the luminaire until it snaps into other side of the mounting clips. (Only for single luminaire installation) Alternately: The required mounting clips may first be pressed onto the luminaire, then the luminaire mounting clip assembly may be mounted on to the mounting surface using two #10 (MS) self-tapping flathead screws per mounting clip. 3 Ensure there is an end cap to the female connector. Go to METHOD 4 - Connections to the Electrical Supply 3

METHOD Installation Steps: Luminaire Installations to be Interconnected with Jumper Cable Planning first: See Multiple Bar Installation details to not exceed the maximum run length per Leader Cable Luminaires must only be mounted using Currrent s standard and slim mounting clips (see Components Required on page ) Align using chalk line, laser projector or similar Flat surface Rotate and Push 1 Secure each luminaire mounting clip to a rigid flat mounting surface using two #10 (MS) self-tapping flathead screws along the intended run of luminaire. To avoid stress and damage to luminaire the entire mounting surface should be flat and the mounting clips be properly aligned. Refer to table on page 7 for required number of mounting clips per luminaire. Press the first luminaire into its mounting clips so that the male connector is oriented towards the intended electrical supply. TIP: Align luminaire on one side of the mounting clips; then rotate the luminaire until it snaps into other side of the mounting clips. Next luminaire Firstluminaire 3 Press the next luminaire in the run into its mounting 4 clips using the same procedure as Step. Remove end cap to the female connector where jumper cable will be installed. Insert the male connector of the batten jumper cable so that it fully engages the female connector of the first luminaire as indicated by hearing clicks. 5 Insert the female connector of the 6 Step 3, 4 and 5 may be repeated for 7 batten jumper cable so that it fully engages the male connector of the luminaire currently being installed as indicated by hearing clicks. To avoid damage, do not bend or otherwise exert excessive force on the Batten connector during installation each additional luminaire in the run. Go to METHOD 4 - Connections to the Electrical Supply 4 Ensure that there is an end cap on the female connector on the last luminaire in the run.

METHOD 3 Installation Steps: Directly Interconnected Luminaires Planning first: See Multiple Bar Installation details to not exceed the maximum run length per Leader Cable Luminaires must only be mounted using Currrent s standard and slim mounting clips (see Components Required on page ) Align using chalk line, laser projector or similar Flat surface Rotate and Push 1 Secure each luminaire mounting clip to a rigid flat mounting surface using two #10 (MS) self-tapping flathead screws along the intended run of luminaire. To avoid stress and damage to luminaire the entire mounting surface should be flat and the mounting clips be properly aligned. Refer to table on page 7 for required number of mounting clips per luminaire. Press the first luminaire into its mounting clips so that the male connector is oriented towards the intended electrical supply. TIP: Align luminaire on one side of the mounting clips; then rotate the luminaire until it snaps into other side of the mounting clips. Next luminaire Firstluminaire 3 Remove the end cap from the female connector on the 4 opposite side of the luminaire. Press the next luminaire in the run into its mounting clips using the same procedure as Step. Push together 5 Slide the luminaire into the previous one in the run until the male connector of the luminaire fully engages the female connector of the previous one as indicated by hearing distinct clicks. To avoid damage, do not bend or otherwise exert excessive force on the Batten connector during installation Steps 3, 4 and 5 may be repeated for each additional luminaires in the run. 6 Ensure that there is an end cap on the female connector on the last luminaire in the run. Go to METHOD 4 - Connections to the Electrical Supply 5

METHOD 4 Connections to Electrical Supply Strain relief 1 Insert the female connector of the batten leader cable so that it fully engages the male connector of the first luminaire in the run as indicated by hearing clicks. See Multiple Bar Installation detail to not exceed maximum run length for one leader. To avoid damage, do not bend or otherwise exert excessive force on the Batten connector during installation Insert the supply end of the leader cable through a suitable strain relief into a proper junction box for the location so that the leader cable outer jacket has passed through the strain relief. Tighten the strain relief onto the leader cable jacket. Leader cable to luminaire(s) 10-77V AC Supply Black (L) White (N) 3 Inside the junction box, connect the line and neutral wires of the AC supply source to the line (black) and neutral (white) wires of the leader cable using suitable wire nuts. Install the junction box cover when complete. IMPORTANT GUIDELINES / CONSEILS IMPORTANTS Les câbles ne doivent pas être cachés à l intérieur ou passer à travers un mur, un plancher, un plafond ou d autres parties de la structure du bâtiment; ne doivent pas être placés au- dessus d un plafond suspendu; ne doivent pas faire partie intégrante de la structuredu bâtiment. Les câbles doivent être installés de façon à être protégés contre l étirement et tout autre dommage; être visibles sur toute leur longueur; utilisés dans la limite de leur capacité électrique, déterminée pour les limites de température de l environnement spécifiée dans ce document. Cables shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure; located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure. Cables shall be routed so that they are not subject to strain and are protected from physical damage; visible over their entire length; and used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions. 6

Multiple Bar Installation Detail Input voltage : 100VAC - 77 VAC, 50/60Hz MO/ HO MO HO Lamp Length Product Code (SKU) Description Code 10VAC 40VAC 77VAC Qty of Mounting Clips Electrical LoadingDetail Typical Current (A) 10VAC 40VAC 77VAC 1ft. 9304679 GEWM135BAT 3500K 40 80 80 0.040 0.034 0.03 8349 GEWM430BAT 3000K 9307304 GEWM435BAT 3500K ft. 8351 GEWM440BAT 4000K 0 40 40 0.08 0.05 0.045 8355 GEWM450BAT 5000K 8356 GEWM471BAT 7100K 8358 GEWM4830BAT 3000K 930511 GEWM4835BAT 3500K 4ft. 8360 GEWM4840BAT 4000K 10 0 0 0.15 0.08 0.075 8361 GEWM4850BAT 5000K 8365 GEWM4871BAT 7100K 8366 GEWM9630BAT 3000K 8ft. 8367 GEWM9640BAT 4000K 8374 GEWM9650BAT 5000K 5 10 10 3 0.3 0.16 0.15 8416 GEWM9671BAT 7100K 1ft. 9304680 GEWH135BAT 3500K 30 56 56 0.07 0.04 0.037 8446 GEWH430BAT 3000K 8461 GEWH440BAT 4000K 851 GEWH450BAT 5000K 0.135 0.07 0.065 ft. 8536 GEWH471BAT 7100K 15 8 8 9307769 GEWH471BAT-PL PURPLE 930517 GEWH4BLBAT BLUE 0.08 0.05 0.045 930513 GEWH4RDBAT RED 0.065 0.04 0.035 4ft. 8ft. 8551 GEWH4830BAT 93051 GEWH4835BAT 8581 GEWH4840BAT 8596 GEWH4850BAT 8776 GEWH4871BAT CCT 3000K 3500K 4000K 5000K 7100K Maximum Bars PerLeader Cable * 7 14 14 9307770 GEWH4871BAT-PL PURPLE 930516 GEWH48BLBAT BLUE 0.15 0.08 0.075 930514 GEWH48RDBAT RED 0.15 0.08 0.07 83086 GEWH9630BAT 3000K 8311 GEWH9640BAT 4000K 83166 GEWH9650BAT 5000K 0.48 0.8 0.6 8311 GEWH9671BAT 7100K 3 7 7 3 9307771 GEWH9671BAT-PL PURPLE 93054 GEWH96BLBAT BLUE 0.3 0.16 0.15 930515 GEWH96RDBAT RED 0.7 0.14 0.16 * Maximum Batten MO run length if combining different bar sizes is: 40ft at 10V and 80ft at 40V/77V Maximum Batten HO run length if combining different bar sizes is: 30ft at 10V and 60ft at 40V/77V 0.4 0.14 0.13 Note: Other SKUs available. custom installation please contact us. 7

Product codes GEWZXXYYBAT *Key for XX: 1 = 1, 4 = 4, 48 = 48, 96 = 96 *Key for YY: 30 = 3000K, 35 = 3500K, 40 = 4000K, 50 = 5000K, 71 = 7100K, RD = RED, BL = BLUE *Key for Z: M = medium, H = high Troubleshooting Symptom All LED fixtures are not illuminated Some LED fixtures are not illuminated Solution Check leader cable connection and/or check circuit breaker. Check plug connectors on the LED fixtures for improper connections or short circuits. Ensure leader cable is securely connected to the female plug connector on the first LED fixture. Check plug connectors on the LED fixtures for improper connections or short circuits. Ensure any jumper cables are securely connected between the male/female plug connectors of the LED fixtures. 8

METHOD 5 Replacement Instructions for directly Interconnected Luminaires Push apart Batten to be replaced Push apart Pinch 1 Unclip plugs on both sides of the batten to be replaced. Push apart battens on either side. TIP: Pinch the ends of the plug while pulling the receptacle end away. To avoid damage, do not bend or otherwise exert excessive force on the Batten connector during removal Standard Clips Slim Clips A Unscrew the mounting clips to completely remove the batten. B Using a screwdriver, gently pry the batten out of the mounting clips. 3 To insert new batten, see Method 3 To avoid damage, do not bend or otherwise exert excessive force on the Batten connector during installation. Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service. Conforms to the following standards: IP66 rated Visit LED.com the latest install guides for your product, please visit: products.currentbyge.com/sign-lighting/batten-led-luminaire All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. 019 GE. www.currentbyge.com SIGN153(Rev 019-01-07) GE07-786 9