Product Data Sheet 3214 JH3-195

Similar documents
Product Data Sheet 4184 NXHH

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 8412 NHU-519

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 4184 NXHH

Product Data Sheet 632 NU-006

Product Data Sheet 4414/2H

Product Data Sheet 8414 NGH

Product Data Sheet 4184 NGX

product specification

Product Data Sheet DV5214 NU

Product Data Sheet DV4118 N

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet 8314 HR-197

4314/17T. Product Data Sheet INDEX

Product Data Sheet ACi 4420 MLR

Product Data Sheet ACi 4420 HHR

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

AC axial fan. blades with special design (K series) with guard grille for full nozzle

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

AC centrifugal fan. backward curved

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

AC centrifugal fan. backward curved

Immersion Pumps PMS and PMS-T sealless

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

AC centrifugal module - RadiCal

AC axial fan. sickled blades (S series) with full square nozzle

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

Energy-saving motors (ESM)

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

Centrifugal pumps. Main catalogue.

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

AC centrifugal fan. forward curved, dual inlet with housing (flange)

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Immersion Pumps PRG sealless

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

AC centrifugal fan. forward curved, dual inlet with housing (flange)

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

FBA08A (80 X 25.5 L )

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

Model Number Structure

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC axial fan. straight blades (A series) with full round nozzle

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

AC axial fan. sickled blades (S series) with guard grille for full nozzle

General_technical_data Series

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

General_technical_data Series

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

AC axial fan. sickled blades (S series) Wall ring with guard grille

Electric Immersion Pumps PRT and PRA, sealless

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

AC centrifugal fan - RadiCal

Model Number Structure

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

AC axial fan. sickled blades (S series)

AC axial fan. sickled blades (S series)

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

MB Series AC Centrifugal Blowers

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Scheda prodotto Relè Series B

BPF. Centrifugal Plug Fans

Model Number Structure

Magnetic and Hydraulic-Magnetic Circuit Breaker

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Table of contents. Three-phase asynchronous motors DA

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

Electric Immersion Pumps PXA and PXK, sealless

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

SITESTAR ELECTRONICS CABINET DESCRIPTION

Ionizer (Nozzle type) Series IZN10

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

3 Phase Power Systems - Designed for Canada

VORTICENT C E RANGE Centrifugal fans

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Transcription:

3214 JH3-195 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 6 3.3 Operating Data - Electrical Interface - Output... 7 3.4 Electrical Features... 7 3.5 Aerodynamics... 8 3.6 Sound Data... 9 4 Environment... 9 4.1 General... 9 4.2 Climatic Requirements*)... 9 5 Safety... 10 5.1 Electrical Safety... 10 5.2 Approval Tests... 10 6 Reliability... 10 6.1 General... 10 11/03/2015 page 2 of 11

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position Fan Clockwise Air outlet over struts Ball bearing Any 2 Mechanics 2.1 General Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 92,0 mm 92,0 mm 38,0 mm 0,240 kg Plastic Plastic wire outlet corner: 30 Ncm remaining corners: 30 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Wires Lead wire length L = 310 mm Tolerance Wire size (AWG) 24 Insulation diameter 1,55 mm Contact See drawing +- 10,0 mm 11/03/2015 page 3 of 11

Colour Operation Wire 1 red + UB Wire 2 blue - GND 11/03/2015 page 4 of 11

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input 11/03/2015 page 5 of 11

3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range p = 0 U 20,0 V 26,0 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 20,0 W 28,3 W 31,2 W Tolerance P +- 18,0 % +- 25,0 % +- 25,0 % 0001 Current consumption p = 0 1.000 ma 1.180 ma 1.200 ma Tolerance I +- 18,0 % +- 25,0 % +- 25,0 % 0001 Speed p = 0 9.250 1/min 10.500 1/min 10.500 1/min Tolerance n +- 13,0 % +- 3,0 % +- 3,0 % 0001 Starting current consumption <= 5.000 ma 11/03/2015 page 6 of 11

3.3 Operating Data - Electrical Interface - Output Tacho type Alarm type 3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor Speed-Controlled Rectifying diode IF <= 10 ma Auto restart approx. 3.500 ma Typical: 0,3 s / 10,0 s 11/03/2015 page 7 of 11

3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 10.500 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 230,0 m3/h Max. static pressure ( p = max. / =0) 550 Pa 11/03/2015 page 8 of 11

3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 10.500 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 120,0 m3/h @ 218 Pa 7,5 bel(a) 66,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 55 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic Requirements*) Humidity requirements humid heat, constant; according to DIN EN 60068-2- 78, 14 days Water exposure Dust requirements Salt fog requirements *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. Please require severity levels and specification parameters from the responsible development departments 11/03/2015 page 9 of 11

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE CSA Association for Electrical, Electronic and Information Technologies Canadian Standards Association CCC China Compulsory Certification No No Yes / CSA audited by UL according to C22.2 No. 113 Fans and Ventilators 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. 45.000 h 30.000 h 11/03/2015 page 10 of 11