INSTALLATION AND MAINTENANCE

Similar documents
Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)

Flame arresters 4301A/4319A ATEX Approved

Operating Instruction Inline Detonation Flame Arrester

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation )

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION...

Installation, Operation and Maintenance Manual for Flame Check

Operating Instructions Inline Detonation Flame Arrester and

Flame Arrestor Design and Application Data

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Inspection and Maintenance of Flame Arresters

Voltmaster Centrifugal Trash Pumps

SERIES 670E End-of-Line Deflagration Flame Arrester

8 Series High Pressure Deflagration Flame Arrestor

EN-DFA Series Detonation Flame Arrestor (ATEX Approved)

Model DFA Detonation Flame Arrestor. Model DFA North America Only. Table of Contents. Introduction WARNING. Product Description

DFA Series Detonation Flame Arrestor (USCG/ATEX Approved)

Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their

These installation and maintenance instructions must be read in full and completely understood before the installation!

7 Series Flame Arrestor

Installation, Operation, and Maintenance Manual

CONTROL VALVE TECHNICAL MANUAL MT100 INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS. Issue December 2009

This document is a preview generated by EVS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

In-Line Detonation Flame Arrester PROTEGO DA-CG

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

IMPORTANT SAFETY NOTICE

Condensate Drain Valve AK 45. Original Installation Instructions English

KITO explosion and endurance burning flame arrester devices

Installation, Operation and Maintenance Manual for Model 7758A Deflagration and Detonation Flame Arrester

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

PREFACE. Dear customer,

Protection & Safety Equipments For Storage Tanks. Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch.

DETONATION FLAME ARRESTER MODEL 7658A

These installation and maintenance instructions must be read in full and completely understood before the installation!

This document is a preview generated by EVS

SAFE USE AND HANDLING OF HOSES AND FLEXIBLE CONNECTIONS IN THE SOLVENTS INDUSTRY

JABSCO & Series 1½ 80 SIZE UTILITY Pump

Industrial flue gas probes. Instruction manual

In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

Flame arresters/vents

Electric Trolling Motor

APT10-2 Automatic Pump Trap

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

QLM and QLD Series DN125 to DN200 Three Port Control Valves

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Operating Instructions

Installation and Operating Guidelines Battery Back-up Pump System

94406 Vertical Inline Deflagration Flame Arrester. Features

Operating & Maintenance Manual For Steam Conditioning Valve

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

94407 Horizontal Inline Deflagration Flame Arrester

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

Maintenance Instructions

Explosion protected terminal boxes type, GHG 72.

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

A Issue F. Instruction Manual. EMF3, EMF10 and EMF20 EMF20 Oil Mist Filter

Instruction Manual. Sewage lifting station compli 300

Why use a flame arrester?

Installation, Operation, and Maintenance Manual

Instruction Manual. EH Mechanical Booster Pumps. A Issue M

VALFONTA USE, INSTALLATION AND MAINTENANCE MANUAL PNEUMATIC CONTROL VALVE MODEL C1

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

NILFISK BA 500 Service Manual

EX Series User Manual

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

GL Ludemann Y-Strainers

Micro Diaphragm Gas Sampling Pumps

part five outboard and portable engines

Micro Diaphragm Gas Sampling Pumps

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

Installation Operation Maintenance

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

INSTRUCTION MANUAL (ATEX / IECEx)

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

PNEUMATIC PUMP Series

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Operating Instructions

An Explosive Situation. Definitions

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

IOM Manual. IOM Manual. Series 76/77.

BASIC PHENOMENOLOGY OF DEFLAGRATION, DDT AND DETONATION

Instruction Manual. XDS Dry Pump. Description Electrical Supply Item Number

Orifice Flow Meters POP-S (E5720 rev /03/2013)

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

Transcription:

System Series SDB A.GENERAL The Deflagration- and Endurance burning Flame Arresters, Series SDB, are intended for use in Piping Systems handling flammable Gases / Vapours of Gas Group Ex. IIA / I. B. GUIDANCE 1. Maximum Temperature limit -20 to +60 C, covering the general Range of Flame Arresters. 2. SDB Series Deflagration / Endurance burning Flame Arresters are designed to protect Piping Systems and Equipment from explosive Deflagrations that have occurred in associated Piping / Equipment or external to the Vent Piping. 3. For use as Endurance burning protection Installation - a Temperature Gauge is recommended 4. ONLY install for Applications it has been designed and specified for and within its tested / certified Limitations refer to Product Data-Sheet for guidance. It is potentially DANGEROUS to use in other than specified Applications. 5. Mounting of all monitoring Devices shall be in accordance with EN50018. 6. Flame Arresters should not be positioned near hot Equipment unless certified for the elevated Temperature, as heat transfer to the Flame Arrester will reduce its Performance and may cause it to fail. 7. Each Flame Arrester is to be secured on either Side with a Shut off Device. Shut off Devices should be fully open during Operation. 8. Continuous monitoring of Pressure drop is advised if the Process is known to contain Particulates or Substances, which can block the Element Matrix and thus Over pressure the System. 9. Metal Parts insulated by Gaskets should be earthed where necessary. 10. Flame velocities and Pressures of flammable Mixtures can be enhanced by upstream turbulence, which can be caused by Bends, Valves or any change in section of the Pipework. The Flame Arrester should only be used for the Process application it is designed for - 11. If the Process conditions or the Pipework configuration change, the Flame Arrester should be checked with the. Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 1 / 6

System Series SDB C. INSTALLATION 1. Remove all Packaging from the Flame Arrester prior to Installation, paying particular attention to the inlet and outlet Housing sections. 2. Mount he Flame Arrester in the Pipeline. The Series SDB is certified for Bi- directional use. 3. FLANGED CONNECTIONS bolt to Flanges of the same Specification as those fitted to the Flame Arrester itself, with intermediate Gaskets of a Type appropriate to the service Conditions. Uniformly tighten the Bolting to ensure a good Seal. 4. The distance to the Flame Source does not exceed an L/D Ratio of 1:50. 5. For Endurance burning protection the Mounting is only allowed in a horizontal position 6. Ensure that any accessory Nozzles are fitted with the necessary Accessories or with Plugs / blanking Flanges or appropriate 7. The certification is for a max. System pressure of 100mbar,- Temperature -20/+60 C 8. When appropriate, it is recommended that a protective Cage be installed to guard the Flame Arrester against accidental Impact from Vehicles or from heavy falling Objects. D. MAINTENANCE Should only be carried out by suitably qualified Personnel. 1. During service the Element Matrix may become blocked with Particles and Impurities from the Atmosphere and /or Process. If too severe, the blockage will impair the free flow of Gases / Vapours. In severe Cases this can cause damage to Equipment and the Flame Arrester itself. 2. A periodic maintenance Schedule is recommended for the Flame arrester, the Frequency should be based on operational Experience and actual operating Conditions, but at least annually. 3. No special Tools are required. Standard Spanners and lifting Equipment for larger Sizes of Flame Arresters, if required Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 2 / 6

System Series SDB 4. The Flame Arrester Series SDB are designed to allow Inspection and Maintenance in Situ i.e without being disconnected from the Pipework. However, this should only be done if it is safe to do so. NOTE: Potentially toxic Substances may have been passing through the Flame Arrester. Always wear appropriate Safety Equipment with Eye protection when working on or near Flame Arresters. 5. Loosen the Bolting around the Central Flanges containing the Element Assembly / Assemblies. 6. Separate the Central Flanges, using any Jacking Bolt that may be fitted to the Flame Arrester or other appropriate means, by an amount sufficient to allow removal of the Gaskets and Element Assembly / Assemblies. Note that there may occur conditions that cal for removing the whole Flame Arrester from the Pipeline for Maintenance / Inspection Work. 7. Remove sufficient bolting to allow the Gasket and Element Assembly to be removed, or, where a Swing out Element Assembly is fitted, for it to be swung out for Iinspection. 8. Remove the Element(s) using lifting Equipment when appropriate, and examine both Surfaces. DO NOT insert any Wire, Probes or metallic Parts into the Element Matrix. 9. If the Element Matrix is visually damaged or corroded it must be replaced before the Flame Arrester is returned into Service. If cleaning is required see Section E before re-fitting. 10. Check if the Sealing Face of the Housing is clean and free from Particles that may affect the Sealing of the Element. NOTE: Any Gap between the Housing and the Gaskets / Elements may provide a Flame Path around the Flame Arrester Element and are therefore DANGEROUS. 11. Fit new Gaskets of the same Specification and re-fit the Element(s) ensuring that it is centrally located. There may be locating Collars fitted to some of the Bolts to assist in this. 12. Replace the Bolting and tighten to the appropriate Torque (see Product Data Sheet). 13. After any external Fire in the Locality of the Flame Arrester, it is mandatory that the Equipment be examined for eventual damage. Particular attention to be paid to the joint Gaskets, replacing them if necessary. Also check the tightness of the Flange Bolting and retighten if necessary. Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 3 / 6

System Series SDB E. CLEANING THE ELEMENT ASSEMBLY 1. DO NOT attempt to remove the Element Matrix from its Gage / Casing. 2. DO NOT allow the Element Assembly to become severely blocked. 3. DO NOT clean by inserting Probes / Wieres into the Cell Structure. 4. DO NOT use excessively corrosive Materials (e.g. hydrochloric Acid) to clean the Element. 5. High- pressure Water jets ARE NOT recommended. 6. The following ARE recommended: Detergents, Solvents, compressed Air, Steam or Ultrasonic. The actual cleaning Method will depend on the Nature of the Substance causing he Blockage. 7. If the Element is DAMAGED during cleaning a NEW Element Assembly should be fitted. If in doubt refer to - or your nearest Representative - for further Advice. F. SPARE PARTS Under normal Conditions only the Element Assembly and Gaskets should need replacing. It is recommended that for every three Flame Arresters of a given Type and Size, at any on Side, at least one Element Assembly is available at al Times. One Set of Gaskets for each Flame Arrester Assembly should also be available. When requesting / ordering Spare Elements the full Type Code, Serial Number and Part Number MUST be quoted / relied fitting the incorrect Element is potentially DANGEROUS. See the Flame Arrester Part identification Tag (fitted to the Element Gage) and / or associated detailed Spare Part List for Details. G. AFTER SALES SERVICE Service is available through,- or the network of regional Agents Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 4 / 6

System Series SDB H. MARKING on the FLAME ARRESTER Bi directional use CE Deflagration Endurance Burning Detonation Ph. +41 52 212 0115 Type Date: Engineering, Anlagenbau Fax +41 52 212 1578 Serial Gas Group max. Gas P Temp. CH-8400 Winterthur info@schaer-hitech.ch EN 12874- Ex mbar max. min. IIA / I IIB SPECIAL CONDITIONS for SAFE USE For Series SDB Ex. IIA / I the Manufacturing is certified for Sizes DN40 (1½ ) to DN200 (8 ) Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 5 / 6

System Series SDB Series SDB / SDD - Installation- and Maintenance Manual Issue 01 December 08 Page 6 / 6