In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

Similar documents
In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

In-Line Detonation Flame Arrester PROTEGO DA-CG

PROTEGO Detonation Flame Arresters. Volume 4. Volume 4. for safety and environment

PROTEGO Detonation Flame Arresters. Volume 4. for safety and environment

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation )

Operating Instruction Inline Detonation Flame Arrester

94406 Vertical Inline Deflagration Flame Arrester. Features

94407 Horizontal Inline Deflagration Flame Arrester

Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their

Flame arresters 4301A/4319A ATEX Approved

Operating Instructions Inline Detonation Flame Arrester and

EN-DFA Series Detonation Flame Arrestor (ATEX Approved)

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)

DATA SHEET TB 23b. BR 23b Rotary plug valve Stainless steel rotary plug valve in DIN - Version. Applications. Versions

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION...

PASSIVE OPERATION Completely self-contained with no reliance on power supplies, sensors, actuators or any external components.

Options guide. Electromagnetic flowmeters. M9xx

DATA SHEET TB 26l. BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version. Application

MAGNETIC COUPLINGS TYPES AND OPERATING DESCRIPTION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I

NAF-Torex butterfly valves DN , Size 3-28, PN 10-40, ANSI Class 150, 300

PROTEGO Technology. Volume 1. Flame Arresters Valves Tank Accessories. Edition for safety and environment 1. for safety and environment

ARI-ZETRIX ANSI. with worm gear. with electric rotary actuator Auma or Schiebel. with pneumatic actuator. with hydraulic actuator

Magnetic-inductive flow meter for hazardous areas

INSTALLATION AND MAINTENANCE

Installation, Operation and Maintenance Manual for Model 7758A Deflagration and Detonation Flame Arrester

DFA Series Detonation Flame Arrestor (USCG/ATEX Approved)

HD series. HD Series 1 technical data 1 components DN RTFE seat 2 Inconel seat 3 "FIRE SAFE" seat 4

PROTEGO Technology. Volume 1. Flame Arresters Valves Tank Accessories. Volume 1. for safety and environment 9. for safety and environment

KITO explosion and endurance burning flame arrester devices

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Flame Arrestor Design and Application Data

Terminal Boxes Series 8125

Modular Explosion Proof Brakes. IECLine rev 0

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Operating Instructions

DETONATION FLAME ARRESTER MODEL 7658A

SERIES 670E End-of-Line Deflagration Flame Arrester

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

Valve Technology DIN EN Butterfly Valves

NAF-Torex butterfly valves DN , Size 3-28, PN 10-40, ANSI Class 150, 300

Level Measurement Continuous level measurement - Capacitance transmitters

SATRON VT Pressure Transmitter

SITRANS F flowmeters SITRANS F C

Type 1a Globe Control Valve

NAF-Duball ball valves

SILOXA FAKA Gas Cleaning System

Ghibson Italia s.r.l. via Cassola 6/ Monteveglio (BO) Italy. Butterfly valves

CCAI, CCAIF, CCAIF..H

BR 14b / BR 14c Application:

Pneum. Buoyancy Transmitter with Torque Tube for Liquid Level, Interface and Density

switchcontrol The robust opto-electric position indicator

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

Flame arresters/vents

Type 441 DIN 442 DIN. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. US Units

BR 20b Ball valve. PFA-lined. Application: Versions:

7 Series Flame Arrestor

Two-Way Metal Seated Ball Valve Type 75-M

Terminal Boxes Series 8125

Norm-Centrifugal Pumps PN 10

GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

BR 14p - PSA. High-Performance Control and Shut-off Butterfly Valve. Application:

Series 26d Ball Valve

Type. Facts. Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Two-Way Soft Seated Ball Valve Type 75-S

BR 10a Control and Shut-off Butterfly valve

Type 459. Type. 459 Safety Relief Valves spring loaded

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Load disconnect switch Series 8146/5-V11

Control Valve fluids with integrated positioner. GS 3 series - DN 15 up to DN 250. material

Garlock Butterfly Valves Technical Catalog Trusted throughout the chemical, petrochemical & many other industries

TECHNICAL BULLETIN. Segmented V-port Ball Valves. Experience In Motion FCD VLENTB

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Type 459. Type 459. Available designs. Cap H2. with bushing 19. Lock nut. Bonnet. Outlet flange 2.4 Outlet adaptor 2.1. spacer.

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

Pneumatic control unit for decentralized automation of ELEMENT process valves

Bray/McCannalok High Performance Butterfly Valves Technical Manual

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

OPTIMASS 3000 Technical Datasheet

Index. D Davy, Humphrey, 5, 84 Decomposition flames, flame propagation, 59

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Product Range. Products for all industrial applications

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

An Explosive Situation. Definitions

Automatic metal-edge filter AF 75 S / AF 95 S

This document is a preview generated by EVS

SITRANS F C. Flow sensor MC2 4/193. Overview

Armaturenwerk Hötensleben GmbH. Valve Technology. A member of NEUMO Ehrenberg Group. Edition 3.0

Two-Way Metal Seated Ball Valve Type 85-M

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Type 455, 456. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. US Units

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

Model DFA Detonation Flame Arrestor. Model DFA North America Only. Table of Contents. Introduction WARNING. Product Description

Transcription:

for stable detonations and deflagrations in a straight through design with shock tube, bidirectional Ø a 1 Design with one temperature sensor 2 3 Connection to the protected side (only for type DA-SB-T-...) Function and Description The in-line detonation fl ame arresters type are the newest generation of fl ame arresters. On the basis of fl uid dynamic, explosion dynamics calculation and decades of experience from fi eld tests, a product line was developed that offers minimum pressure loss and maximum safety. The fl ame arrester uses the Shock Wave Guide Tube Effect (SWGTE) to separate the fl ame front and shock wave. The result is an in-line detonation arrester without a classic shock absorber; in addition the use of FLAMEFILTER discs is minimized. The devices are symmetrical and offer bidirectional fl ame arresting for defl agrations and stable detonations. The arrester essentially consists of two housing parts with an integrated shock tube (1) and the PROTEGO fl ame arrester unit (2) in the center. The PROTEGO fl ame arrester unit is modular and consists of several FLAMEFILTER discs (3) and spacers fi rmly held in a FLAMEFILTER cage. The number of FLAME- FILTER discs and their gap size depends on the arrester s conditions of use. By indicating the operating parameters such as temperature, pressure and explosion group, and the composition of the fl uid, the optimum detonation arrester can be selected from a series of approved devices. The fl ame arresters are available for all explosion groups. The standard design can be used up to an operating temperature of +60 C / 140 F and an absolute operating pressure up to 1.1 bar / psi. Numerous devices with special approval can be obtained for higher presssures (see table 3) and higher temperatures. b Design with two temperature sensors NG c dismantling dimension for servicing (temperature sensor) Type-approved in accordance with the current ATEX Directive and EN ISO 16852 as well as other international standards. Special Features and Advantages optimized performance from the patented Shock Wave Guide Tube Effect (SWGTE) less number of FLAMEFILTER discs from the use of the patented shock tube (SWGTE) modular fl ame arrester unit enables each individual FLAMEFILTER discs to be replaced and cleaned different series allow increase of FLAMEFILTER size for given flange connection resulting in lower pressure drop across the device service-friendly design expanded application range for higher operating temperatures and pressures bidirectional operation as well as any direction of flow and installation position installation of temperature sensors are possible minimum pressure loss and associated low operating and life-cycle cost cost efficient spare parts use of stabilized FLAMEFILTER discs is possible use of PROTEGO Flame Arrester Unit in unique NEW maintenance friendly design reduces service cost Design Types and Specifications There are four different designs available: Basic in-line detonation fl ame arrester In-line detonation flame arrester with integrated temperature sensor* as additional protection against short time burning from one side In-line detonation flame arrester with two integrated temperature sensors* for additional protection against short time burning from both sides In-line detonation flame arrester with heating jacket Additional special fl ame arresters upon request *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) DA-SB - - DA-SB - T - DA-SB- TB - DA-SB - H - All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.com 126 KA / 4 / 0318 / GB

Stabilized FLAMEFILTER Discs (Flyer pdf) New PROTEGO Flame Arrester Unit unique maintenance friendly design (Flyer pdf) Table 1: Dimensions Dimensions in mm / inches To select nominal width/nominal size (NG/) - combination, Additional nominal width/nominal size (NG/) - combinations please use the fl ow capacity charts on the following pages for improved fl ow capacity upon request standard (special sizes up to NG 2000/80, 1000/40 available) b NG a IIA-P1,1 IIA-P1,4-X3 IIB3-P1,1 IIB3-P1,4-X3 IIC-P1,1 c 6" 50 2 285 / 11.22 388 / 15.28 412 / 16.22 6" 65, 80 2 ½, 3 285 / 11.22 388 / 15.28 412 / 16.22 412 / 16.22 * dimension b only for P ** dimension b only for P1.2 / 17.4 *** EN 12874 200 8" 100 4 340 / 13.39 476 / 18.74 488 / 19.21 512 / 20.16 520 / 20.47 300 12" 445 / 17.52 626 / 24.65 626 / 24.65 650 / 25.59 650 / 25.59 638 / 25.12 570 / 22.44 400 16" 200 8 565 / 22.24 700 / 27.56 724 / 28.50 724 / 28.50 724 / 28.50 700 / 27.56 620 / 24.41 500 20" 250 10 670 / 26.38 / 31.50* / 31.50 824 / 32.44 824 / 32.44 788 / 31.02 670 / 26.38 600 24" 300 12 780 / 30.71 39.37* 39.37 39.37 39.37 39.37*** 720 / 28.35 700 28" 350 14 895 / 35.24 *** 770 / 30.31 32" 400 1 1015 / 39.96 *** 820 / 32.28 1000 40" 500 20 1230 / 48.43 1600 / 62.99 1600 / 62.99 950 / 37.40 1200 48" 600 24 1455 / 57.28 1 / 70.87 1 / 70.87 1050 / 41.34 1600 64" 32 1915 / 75.39 2200/ 86.61** 1250 / 49.21 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) > 0,90 mm IIA D 0,65 mm IIB3 C < 0,50 mm IIC B Special approvals upon request Table 3: Selection of max. operating pressure Expl. Gr. NG 50 2 IIA P max IIB3 P max 2.2 / IIC P max 31.9 65, 80 2 ½, 3 2.2 / 31.9 200 8 100 4 300 12 400 1 200 8 500 20 250 10 600 24 300 12 * 700 28 350 14 * 32 400 * P max = maximum allowable operating pressure in bar / psi absolut, higher operating pressure upon request in-between size up to P max upon request * capacity charts upon request 1000 40 500 20 1200 48 600 24 1600 64 32 1.2 / 17.4 KA / 4 / 0318 / GB for safety and environment 127

for stable detonations and deflagrations in a straight through design with shock tube, bidirectional Table 4: Specification of max. operating temperature 60 C / 140 F 200 C / 392 F Tmaximum allowable operating temperature in C higher operating temperatures upon request - X3 Designation Table 5: Material selection for housing Design A B C Housing Heating jacket (DA-SB-(T)-H-...) Steel Steel Stainless Steel Stainless Steel Gasket PTFE PTFE PTFE Flame arrester unit A, B B, C, D D Special materials upon request Hastelloy Stainless Steel The housing is also available in Steel with ECTFE coating. Table 6: Material combinations of the flame arrester unit Design A B C D FLAMEFILTER cage Steel Stainless Steel Stainless Steel Hastelloy FLAMEFILTER * Stainless Steel Stainless Steel Hastelloy Hastelloy Spacer Stainless Steel Stainless Steel Hastelloy Hastelloy Special materials upon request *the FLAMEFILTER are also available in the materials Tantalum, Inconel, Copper, etc. when the listed housing and cage materials are used. Table 7: Flange connection type EN 1092-1; Form B1 ASME B16.5; lbs RFSF other types upon request All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.com 128 KA / 4 / 0318 / GB

Flow Capacity Charts * * ** * P1.4 ** P1.2 DA-SB-IIA-P1.1 Leistung-000324-en X3 maximum allowable operating temperature 200 C DA-SB-IIA-P1.4-X3 Leistung-000022-en The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. KA / 4 / 0318 / GB for safety and environment 129

Flow Capacity Charts DA-SB-IIB3-P1.1 Leistung-000332-en X3 maximum allowable operating temperature 200 C DA-SB-IIB3-P1.4-X3 Leistung-000026-en The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.com 130 KA / 4 / 0318 / GB

DA-SB-IIC-P1.1 Leistung-000333-en KA / 4 / 0318 / GB 131