ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Similar documents
ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Motorised and automatic transfer enclosed switchess

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO M and MV Universal load break switches from 16 to 160 A

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

An innovative technology

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC


3 - Protection components Motor circuit-breakers

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Miniature Circuit Breaker

BETA Switching Switches and Light Indicators

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

ATyS t M Automatic Transfer Switching Equipment

Fuse switch disconnectors

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

vertical fuse switch disconnectors

Breakers and Switches. Switches Change-over and transfer switches

25A 25A 32A 40A 40A 63A 63A 80A

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX moulded case circuit breakers

500V / V /

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

CATALOGUE. Solutions for Power, Control & Safety

Fuse switch disconnectors

Euroload Changeover Switch

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

What you need to know. Â Conformity to standards

MS General Information Extended Product Type: MS

Motorized switch-disconnectors OTM 40 to 125 Amperes

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Technical Data Accessories MCBs Ex9B.

Low Voltage Switches. Switches Motorized change-over switches OTM _C

DPX 630 Electronic release

Modular contactors and relays

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

DPX 1600 Electronic release

Wall mounted switchgear

TAE pole Contactors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Series 230 Automatic Transfer Switch

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

MANUALLY OPERATED CHANGEOVER SWITCHES

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

ATS* By-Pass solution

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Vistop TM isolating switches 63 to 160A

FL series position switches

General Characteristics

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

MINIATURE CIRCUIT BREAKER

PowerLine OS Switch Fuses A, 690V

Switch-disconnectors OT , OETL 3150

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

with Vacuum Circuit Breaker HAF

Phase + Neutral, neutral on right side

Technical data for manual motor starters Type MS325

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Thermal magnetic and trip-free switches

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Transcription:

Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated transfer switches with positive break indication. They enable the on-load transfer of two three-phase supplies via remote volt-free contacts, from either an external automatic controller, using pulse logic, or a switch. They are intended for use in low voltage power supply systems where a brief interruption of the load supply is acceptable during transfer. Advantages Extensive power supply range The is available in four supply versions, each with a broad range (+/-30%). The four versions are: 12 VDC power supply. 24/48 VDC power supply. 230 VAC single power supply. 2 x 230 VAC dual power supply. Safety and reliability products use stable position technology, ensuring constant pressure on the contacts and preventing premature faults. In addition, they do not require a power supply to maintain position, thus protecting their loads from voltage fluctuations. Simplified maintenance Maintenance can be carried out easily under load, with manual operation still available. The control and motorisation section can be replaced simply by removing 4 screws, with no work required on the installation cabling. ATyS d S: Dual power supply In addition to the functions offered by the, the ATyS d S incorporates supply redundancy without the need for additional wiring. This is obtained by integrating a double supply (2 independent supplies) directly within the product. > Extensive power supply range > Safety and reliability > Easy integration > Simplified maintenance > ATyS d S: Dual power supply Conformity to standards > IEC 60947-6-1 > IEC 60947-3 > GB 14048-11 Approvals and certifications Easy integration products can be easily installed inside enclosures. Their design, and in particular their compact size, enables integration within most 200 mm deep enclosures. 434 General Catalogue 2017-2018

s No. of poles Power supply Bridging bars 40 A 63 A 80 A 100 A 125 A 4 P 24/48 VDC 9506 4004 4 P 12 VDC 9505 4004 4 P 230 VAC 9503 4004 9599 4001 4 P 24/48 VDC 9506 4006 4 P 12 VDC 9505 4006 4 P 230 VAC 9503 4006 Source side 9599 4001 4 P 24/48 VDC 9506 4008 9594 4012 4 P 4 P 12 VDC 9505 4008 9509 4013 Load side 4 P 230 VAC 9503 4008 9599 4001 4 P 24/48 VDC 9506 4010 9594 9012 4 P 12 VDC 9505 4010 4 P 230 VAC 9503 4010 9599 4001 4 P 24/48 VDC 9506 4012 4 P 12 VDC 9505 4012 4 P 230 VAC 9503 4012 9599 4001 Terminal shrouds Voltage tap Terminal retainer DIN rail 9599 4003 4 modules 9599 4002 ATyS d S No. of poles Power supply ATyS d S Bridging bars 40 A 4 P 2 x 230 VAC 9513 4004 63 A 4 P 2 x 230 VAC 9513 4006 80 A 4 P 2 x 230 VAC 9513 4008 100 A 4 P 2 x 230 VAC 9513 4010 125 A 4 P 2 x 230 VAC 9513 4012 4 P 9509 4013 Terminal shrouds Voltage tap Terminal retainer DIN rail Source side 9594 4012 Load side 9594 9012 9599 4001 9599 4003 4 modules 9599 4002 General Catalogue 2017-2018 435

Accessories Bridging bars For bridging power terminals on the top or bottom side of the switch. No. of poles 40 125 4 P 9509 4013 acces_395_a_2_cat Voltage tap Enables the required power supply for 230 VAC and ATyS d S products to be tapped directly from the product's incoming power terminals. Can also be utilised in applications without neutral, to provide 400 VAC to the autotransformer. 40 125 9599 4001 atys-s_022_a Terminal retainer These clips have a dual function: - to prevent direct access to the power supply and control terminals and - to secure these connector terminals. Pack 40 125 9599 4003 atys-s_021_a Terminal shrouds IP2X protection against direct contact with terminals or connecting parts. Terminal shrouds for the source side Pack 40 125 9594 4012 atys-s_020_a Terminal shrouds for the load side Pack 40 125 9594 9012 atys-s_020_a Autotransformer 400/230 VAC For applications without neutral, this autotransformer provides the 230 VAC required to power these ATyS products. Dimensions 75x80x72 mm 40 125 9599 4004 DIN rail This 4-module DIN rail can be installed directly on the front of the and can be utilised, for example, for the installation of a surge protection device. 40 125 9599 4002 acces_417_a_1_cat 436 General Catalogue 2017-2018

Spares Motorisation unit The motorisation module of the can be easily replaced in case of problems, even when the load is supplied. Switching unit s to be used for replacing the switching module of products. Manual emergency operation handle This handle can be used on the product whether the motor unit is mounted or not. Connector kit 12 VDC 24/48 VDC 230 VAC ATyS d S 2x230 VAC 40 9505 5004 9506 5004 9503 5004 9513 5004 63 9505 5006 9506 5006 9503 5006 9513 5006 80 9505 5008 9506 5008 9503 5008 9513 5008 100 9505 5010 9506 5010 9503 5010 9513 5010 125 9505 5012 9506 5012 9503 5012 9513 5012 40 9509 1004 63 9509 1006 80 9509 1008 100 9509 1010 125 9509 1012 40 125 9599 5012 This kit, including all the connector types for the different products, can be ordered in case of loss or breaking of one connector. 40 125 9509 0002 acces_416_a_1_cat poign_058_a_1_x_cat acces_414_a_1_cat acces_415_a_1_cat General Catalogue 2017-2018 437

Enclosed solutions General characteristics and ATyS d S Adapted to mechanical risk and dust hazard. Protection degree: IP3X (IP54 optional) Colour: RAL 7035, epoxy polyester powder. Wall mounting: 4 fixing lugs supplied loose. Connection of cables: top or bottom. Locking system: 3 mm double-bar Lock (key supplied) Power network 230/400 VAC +/-30%, 50/60 Hz. Two power supplies: 12 VDC and 2 x 230 VAC. Manual emergency operation handle provided with the enclosure. Bridging bars provided fitted on the product. coff_418_a s No. of poles 12 VDC ATyS d S 2 x 230 VAC 40 4 P 3505 4004 3513 4004 63 4 P 3505 4006 3513 4006 80 4 P 3505 4008 3513 4008 100 4 P 3505 4010 3513 4010 125 4 P 3505 4012 3513 4012 Accessories Factory fitted Description LEDs indicating if voltage is present 9599 0005 LEDs for position indication 9599 0006 TESTS/AUTO modes selection (with C30 option) 9599 0007 Priority selection (with C30 option) 9599 0008 Surge arresters for enclosure (SURGYS D40) 9599 0010 Three-phase kit without neutral 9599 0012 Kit for auxiliary output (3Ph+N) 16A 9599 0016 Copper bar connection kit 9599 0019 IP54 kit 9599 0020 IPXXB protection screen (door open) 9599 0021 Battery charger 9599 0024 Kit for voltage sensing on terminals 9599 0028 Auxiliary kit for control on terminals 9599 0029 Kit for ATyS C30 control/command 9599 0030 Customer fit Description Copper bar connection kit 9599 0018 IP54 kit 9599 0020 IPXXB protection screen (door open) 9599 0021 Dimensions Connection crosssection (mm²) H (mm) L (mm) P (mm) Weight (kg) 40 10 600 400 200 25 S1 450 S2 12.5 200 63 16 600 400 200 25 P1 P2 80 25 600 400 200 25 LOAD 100 35 600 400 200 25 125 50 600 400 200 25 600 560 coff_423_a_1_cat 9 438 General Catalogue 2017-2018

Characteristics according to IEC 60947-3 and IEC 60947-6-1 40 to 125 A Thermal current I th at 40 C 40 A 63 A 80 A 100 A 125 A Rated insulation voltage U i (V) (power circuit) 800 800 800 800 800 Rated impulse withstand voltage U imp (kv) (power circuit) 6 6 6 6 6 Rated insulation voltage U i (V) (operation circuit) 300 300 300 300 300 Rated impulse withstand voltage U imp (kv) (operation circuit) 4 4 4 4 4 Rated operational currents I e (A) according to IEC 60947-6-1 Rated voltage Utilisation category A/B A/B A/B A/B A/B 415 VAC AC-31 B 40 63 80 100 125 415 VAC AC-32 B 40 63 80 80 80 Rated operational currents I e (A) according to IEC 60947-3 Rated voltage Utilisation category A/B A/B A/B A/B A/B 415 VAC AC-20 A / AC-20 B 40/40 63/63 80/80 100/100 125/125 415 VAC AC-21 A / AC-21 B 40/40 63/63 80/80 100/100 100/125 415 VAC AC-22 A / AC-22 B 40/40 63/63 80/80 100/100 100/100 415 VAC AC-23 A / AC-23 B -/40 -/63 -/63 -/63 -/63 Fuse protected short-circuit withstand (ka rms prospective) Prospective short-circuit current (ka rms) 50 50 50 25 15 Associated fuse rating (A) 40 63 80 100 125 Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s (3) Rated short-time withstand current 0.3s I cw (ka rms) 3.5 3.5 3.5 3.5 3.5 Short-circuit capacity as per IEC 60947-6-1 Rated short-time withstand current 0.03 s. (ka) 5 5 5 5 - Rated short-circuit making capacity l cm (ka peak) 7.65 7.65 7.65 7.65 - Short-circuit capacity as per IEC 60947-3 (without protection) Rated short-time withstand current 1 s. I cw (ka rms) 2.5 2.5 2.5 2.5 2.5 Rated peak withstand current (ka peak) 12 12 12 12 12 Connection Maximum Cu cable cross-section (mm 2 ) 50 50 50 50 50 Tightening torque mini / maxi (Nm) 1.2/3 1.2/3 1.2/3 1.2/3 1.2/3 Switching time (Standard setting) I - 0 or II - 0 (ms) 500 500 500 500 500 I - II or II - I (ms) 1000 1000 1000 1000 1000 Duration of "electrical blackout" I - II (ms) minimum 500 500 500 500 500 Power supply Power supply 12 VDC min / max (VDC) 9/15 9/15 9/15 9/15 9/15 Power supply 24/48 VDC min / max (VDC) 17/62 17/62 17/62 17/62 17/62 Power supply 230 VAC min / max (VAC) 160/310 160/310 160/310 160/310 160/310 Control supply power demand Power supply 12 VDC inrush / nominal (VA) 200/40 200/40 200/40 200/40 200/40 Power supply 24/48 VDC inrush / nominal (VA) 200/40 200/40 200/40 200/40 200/40 Supply 230 VAC inrush / nominal (VA) 200/40 200/40 200/40 200/40 200/40 Mechanical characteristics Durability (number of operating cycles) 25 000 25 000 25 000 25 000 25 000 Weight and ATyS d S 4 P (kg) 3 3 3 3 3 (1) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available. Please consult us. General Catalogue 2017-2018 439

8 - ATyS d S Terminals and connections DC version 1 2 atys_831_b_1_x_cat 7 401402 4 5 6 317316315314 04 01 24 21 14 11 DC 1 preferred source 2 alternate source 1 : position 0 control 2 : position I control 3 : position II control 4 : auxiliary contact, closed when the switch is in position 0 5 : auxiliary contact, closed when the switch is in position II 6 : auxiliary contact, closed when the switch is in position I 7 : power supply 12 VDC (9-15 VDC) or 24 VDC / 48 VDC (17-62 VDC) depending on the version. 1 2 3 : 230 VAC 1 2 atys_832_a_1_x_cat 7 301302 4 5 6 317316315314 04 01 24 21 14 11 1 2 preferred source alternate source 1 : position 0 control 2 : position I control 3 : position II control 4 : auxiliary contact, closed when the switch is in position 0 5 : auxiliary contact, closed when the switch is in position II 6 : auxiliary contact, closed when the switch is in position I 7 : power supply kit: 230 VAC (160-310 VAC) 1 2 3 ATyS d S: 2 x 230 VAC 1 2 atys_830_a_1_x_cat 7 101102 201202 4 5 6 317316315314 04 01 24 21 14 11 1 2 3 1 2 preferred source alternate source 1 : position 0 control 2 : position I control 3 : position II control 4 : auxiliary contact, closed when the switch is in position 0 5 : auxiliary contact, closed when the switch is in position II 6 : auxiliary contact, closed when the switch is in position I 7 : power supply kit I: 230 VAC (160-310 VAC) 8 : power supply kit II: 230 VAC (160-310 VAC) 440 General Catalogue 2017-2018

Dimensions 11 104.5 26.5 27.5 26.5 8 15 37 25 72 106 94 90.6 100 100 143.5 113 72 115.2 74 44 198 100 181 42.5 14 Cut-out dimension M6 125 3 2 Ø 6.4 16 atys-s_024_a_1_x_cat 45 Connection terminal Ø M6 atys-s_036_a_1_x_cat 16 14 General Catalogue 2017-2018 441