Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

Similar documents
Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

C32 ACERT Generator Set Electric Power

3516B Generator Set Electric Power

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Generator Set Specifications 320 ekw (400 kva)

3412C Generator Set Electric Power. Specifications. Benefits and Features

Generator Set Specifications 480 ekw 600 KVA

Specifications. 3406C Generator Set Electric Power

Voltage 220 to or 1800 RPM

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Generator Set Specifications 100 ekw (125 kva)

220 to volts. Electronic unit injection

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

400 to 11,000 Volts. Standby, Prime, Continuous

Continuous, Prime, Standby, Mission Critical

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Specifications. C13 Generator Set Electric Power

Generator Set Specifications 60 ekw (75 kva)

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

DIESEL GENERATOR SET FEATURES

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Cat C Diesel Generator Sets

Cat C Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3412 Diesel Generator Sets

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Cat 3512 Diesel Generator Sets

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Cat C32 Diesel Generator Sets

Cat 3512 Diesel Generator Sets

STANDBY 400 ekw 500 kva

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 225 ekw 281 kva

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Cat 3512B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Cat 3512B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Cat 3516C Diesel Generator Sets

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

Cat C32 Diesel Generator Sets

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

Aftercooler (Separate Circuit) N/A N/A

Cat C32 Diesel Generator Sets

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Transcription:

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not refl ect actual confi guration Specifications Generator Set Specifications Rating (ekw) Rating (kva) Voltage Frequency Speed ` 880 1100 415 Volts 50 Hz 1500 rpm Generator Set Configurations Emissions/Fuel Strategy Low Fuel Consumption Engine Specifications Engine Model C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel Bore 145 mm Displacement 32.1 L Stroke 162 mm Compression Ratio 15.0:1 Aspiration Turbocharged Aftercooled Governor Type ADEM A4 Fuel System MEUI Page 1 of 7

Benefits & Features Cat Diesel Engine Generator Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Matched to the performance and output characteristics of Cat engines Industry-leading mechanical and electrical design Industry-leading motor starting capabilities High efficiency Cat EMCP Control Panel The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP 4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP 4 systems can be further customized to meet your needs through programming and expansion modules. Page 2 of 7

Standard Equipment Air Inlet Cooling Exhaust Air cleaner Packaged-mounted radiator Exhaust muffler Exhaust flange outlet Fuel Primary fuel filter with integral water separator Secondary fuel filter Fuel priming pump Generator Matched to the performance and output characteristics of Cat engines Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time IP23 protection Power Termination Bus bar Control Panel Mounting EMCP 4.2 generator set controller Rubber anti-vibration mounts Starting/Charging General Charging alternator 990 liter fuel tank Paint Caterpillar Yellow except rails and heat radiators black Page 3 of 7

Optional Equipment Generator Winding and bearing temperature detectors Anti-condensation heater Oversize and premium generators Coastal Insulation Protection Control Panels EMCP 4.3 and EMCP 4.4 Generator temperature monitoring and protection Load share module Digital I/O module Remote monitoring software Starting/Charging General Jacket water heater The following options are based on regional and product configuration: Heavy-duty air cleaner Option for remote mounting of UIP Circuit breaker panel Page 4 of 7

ELECTRIC POWER Technical Spec Sheet STANDARD C32 ACERT 880ekW/ 1100kVA/ 50 Hz/ 1500 rpm/ 415V/ 0.8 Power Factor Rating Type: Prime ` Fuel Strategy: Low Fuel Consumption C32 ACERT 880 ekw/ 1100 kva/50 Hz 1500 rpm/ 415V Image shown may not refl ect actual confi guration Package Performance Generator Set Power Rating with Fan @ 0.8 Power Factor 880 ekw Generator Set Power Rating 1100 kva Aftercooler (separate circuit) type ATAAC Fuel Consumption 100% Load with Fan 220.7 L/hr 75% Load with Fan 164.8 L/hr 50% Load with Fan 116.1 L/hr 25% Load with Fan 68.7 L/hr Cooling System 1 Engine Coolant Capacity 55.0 L Inlet Air Combustion Air Inlet Flow Rate 67.9 m³/min Max. Allowable Combustion Air Inlet Temp 49 C LEHE1444-00 Page 5 of 7

ELECTRIC POWER Technical Spec Sheet STANDARD C32 ACERT 880ekW/ 1100kVA/ 50 Hz/ 1500 rpm/ 415V/ 0.8 Power Factor Rating Type: Prime Fuel Strategy: Low Fuel Consumption Exhaust System Exhaust Stack Gas Temperature 440.6 C Exhaust Gas Flow Rate 170.3 m³/min Exhaust System Backpressure (maximum allowable) 6.7 kpa Heat Rejection Heat Rejection to Jacket Water Heat Rejection to Exhaust (total) Heat Rejection to Aftercooler Heat Rejection to Atmosphere from Engine Heat Rejection to Atmosphere from Generator 308 kw 752 kw 196 kw 124 kw 45 kw Alternator 2 Motor Starting Capability @ 30% Voltage Dip 3093 skva Current 1530 Amps Frame Size 1424 Excitation IE Temperature Rise 125 C 1 For ambient and altitude capabilities consult your Cat dealer. Air fl ow restriction (system) is added to existing restriction from factory. 2 Generator temperature rise is based on a 40 C (104 F) ambient per NEMA MG1-32. Page 6 of 7

ELECTRIC POWER Technical Spec Sheet STANDARD C32 ACERT 880 ekw/ 1100 kva/ 50 Hz/ 1500 rpm/ 415V/ 0.8 Power Factor Rating Type: Prime Fuel Strategy: Low Fuel Consumption DEFINITIONS AND CONDITIONS Applicable Codes and Standards: ISO3046, ISO8528, IEC60034-1, IS4722. Note: Codes may not be available in all model configurations. Please consult your local Cat dealer representative for availability. Prime: Output available with varying load for unlimited time.prime power in accordance with ISO8528. 10% overload power in accordance with ISO 3046. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO 3046 standard conditions. Fuel Rates are based on fuel oil of 35 API [16 C] gravity having an LHV of 42 780 kj/kg when used at 29 C and weighing 838.9 g/liter. Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding low sulfur fuel and biodiesel capability, please consult your Cat dealer. Performance No.: EM0745 Generator Arrangement:5120397 Date: 26/10/2018 Source Country: India (10/18) www.cat.com/electricpower. 2018 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, ACERT, MEUI, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.