INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

Similar documents
INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

LAWN SPRINKLER, IRRIGATION PUMP

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

Oil Filter Cart. Quad Filtration OPERATOR S MANUAL & PARTS LIST

Low Profile J Series Power Unit with Vane Pump

MOTORVAC TECHNOLOGIES INC. TRANSTECH-1000 Transmission Service System

HexPro Series Low Profile Wrenches

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Low Profile Wrenches Operation and Maintenance Manual

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN

Portable Filter Carts Models 5MF and 10MF

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual


3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

Voltmaster Centrifugal Trash Pumps

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Binks MODELS & AGITATOR DRIVE UNITS

M-1115S Series Fuel Pump

APP pump instruction APP and APP 16-22


JARVIS. Model 50G Hydraulic Dehorner

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Pump Operating and Maintenance Manual - Models

THAWZALL Manufactured by THAWZALL, Inc. MODEL 2M SPECIFICATIONS AND PERFORMANCE SPECIFICATIONS: MODEL 2M

WALKIE HIGH LIFT HYDRAULIC SYSTEM

M OTO R. The electric motor. DC - direct current voltage.

Battery Powered Hydraulic Pump; Kit PN [ ]

Operating Instructions & Parts Manual

IBT Series Square Drive Torque Wrenches

Warning and Safety Precautions

Table of Contents WARRANTY

#9040 FUEL TANK SWEEPER

Page 1 of 19. Part# /10/2006

MOTOR. The electric motor. DC - direct current voltage.

OIL DISPENSING SYSTEM

Fuel System Service & Diagnostic Equipment OPERATOR S MANUAL MCS 245

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Owner s Manual MODEL NO: S400A SERIAL NUMBER 5000

PIT CLEANING SYSTEM PIT CLEANER ASSEMBLY: RC

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

OPERATION AND MAINTENANCE MANUAL

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Multi-Spray Unit Air-Assisted Airless Spray Unit MSU-111N (13:1 Stand Mount) MSU-113N (13:1 Cart Mount) MSU-114N (13:1 Wall Mount)

Electric Diesel Pump EDP/12, EDP/24

Temperature Sensor Series

Separator Systems Operations & Maintenance Manual

WA 2719 ( 604 ) ( 604 ) , H.E.R.O.

STAINLESS STEEL DETERGENT INJECTOR AW

OPERATION AND PARTS MANUAL

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

Hydraulic PTO Flow Device

Maintenance and Repair

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

VICE MOUNTED BEAD ROLLER

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

OPERATION AND SERVICE MANUAL. McGILL UNIVERSITY PROJECT: MCS-3237 SUBJECT: HYDRAULIC POWER UNIT AND ROTARY ACTUATORS DECEMBER 2001

Air Operated 1:1 Oil Ratio Pump OP-11

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

Pneumatic High-Viscosity Filtration System Instruction Manual

Installation, Operating and Maintenance Manual

Model 5-025, 5-050, &

08 general Purpose Pumps

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

Starting up hydraulic systems

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

Air-Assist Service Jack Max. Capacity: 10 Tons

DURA SHOT S SPRAYERS.

SOLID/LIQUID SEPARATION AND COALESCING SYSTEMS

Installation and Operation Manual

OPERATORS MANUAL/INSTRUCTIONS/PARTS & SERVICE FOR MANUAL & ELECTRIC

Paint Pumps INST Manual

CENTRO-MATIC PUMP, MODELS 84050, & 85460

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

High Lift Transmission Jack

Oil storage station Standard model. Instructions for use

INSTRUCTIONS CONVEYORS & SEPARATORS

JARVIS. Model HTC -80 Hog Toe Cutter

Polypropylene Piston Drum Pumps

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

G8 Portable Fuel Transfer Pump Owner s Manual

SAFETY MANUAL READ FIRST!

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

ASSEMBLY and OPERATING INSTRUCTIONS Mission Oaks Blvd. / Camarillo, CA 93011

HSE M11 (AFTER SERIAL # )

50:1 Grease Pump Kits

SANWA STAINLESS STEEL MAGNET DRIVE PUMP INSTRUCTION MANUAL. Request to Users

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

OWNER S MANUAL. Model GALLON SPRAYER REVISION 11/11

Trike Conversion Installation Guide for Harley-Davidson Sportster Motorcycles 2004 & Up Revision 7

Routine Compressor Maintenance

Electric Vehicle Charging Station

Transcription:

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF11-610-603 MM4-610-603 Made in the U.S.A. by Plastic Process Equipment, Inc. copyright 2006

RECEIVING: Please thoroughly inspect your Hydraulic Oil Filtration System and report any damage to the motor freight carrier before uncrating for setup. They are responsible for any damage incurred during transit. Make note of model and serial numbers. These numbers must be used when ordering parts or accessories from. ELECTRICAL: The Hydraulic Oil Filtration System comes pre-wired for 115V/1/60 power. Always use a grounded 120 volt outlet. If you must use an extension cord, ensure that the extension cord's rating is of the proper size. Failure to do so could cause a low voltage condition and premature failure of the unit. INTRODUCTION: The Hydraulic Oil Filtration Systems are self contained oil filtration systems. They use replaceable filters. The units operate by recirculation, pumping the oil from the reservoir through a filter and back into the reservoir. SAFETY PRECAUTIONS: WARNING: EXPLOSION HAZARD. DO NOT PUMP FLAMMABLE LIQUID SUCH AS GASOLINE, ALCOHOL, SOLVENTS, ETC. WARNING: DO NOT USE WHERE FLAMMABLE VAPORS ARE PRESENT. MOTOR CAN SPARK AN EXPLOSION. 1) Read operating instructions thoroughly. 2) All personnel using and operating the filter should wear suitable protective clothing and goggles. 3) Do not perform service or replace cartridge unless electrical power supply is disconnected. OPERATION: When using the filter for the first time on an oil sump or reservoir, it is sometimes necessary to replace the filter cartridge during initial removal of the sludge which is accumulated over a period of time. Once the cleanup of the oil has been accomplished, continued periodic use of the filter will keep the system in clean condition and will extend life of the filter cartridges. Each reservoir should be filtered as frequently as possible. This can be done without shutting down the machinery or removing the oil from the reservoir. The filter should be permitted to pump four times the reservoir capacity to obtain thorough filtration of the oil. When the desired clarity has been reached, the filter should be advanced to the next reservoir. In this manner all reservoirs will be filtered on a scheduled program and the oil will be maintained at a constant, high clarity level. NOTE: It is recommended that the Hydraulic Oil Filtration System be used with oil at machine operating temperature. When operating the filter on cold oil, the high initial pressure may cause it to appear the filter cartridges are fully loaded with dirt. This practice is not harmful, but should be avoided whenever possible. When salvaging a drum of oil at room temperature, the above conditions will exist so the gauge pressure should be watched closely.

START-UP: FILTERING BY RECIRCULATION: 1) Connect suction and discharge hoses. 1) Place both Probes in reservoir. Locate at opposite ends or at different depths to obtain maximum circulation across reservoir. To prevent pump cavitation, keep suction hose from touching bottom or side wall of tank. 2) Plug extension cord into convenient 115 Volt outlet and switch toggle to ON position. 3) Filter to clarity by continuously recirculating. TRANSFER PUMPING: 1) Place suction hose in drum, place discharge hose in machine, or vice-versa. 2) Transfer oil from drum to machine. OIL SALVAGE: Extremely dirty oil may be reconditioned by filtering from one storage drum to another. This method assures that all the oil has passed through the filter. Four passes will remove all the sediment. Letting the oil settle for several hours and drawing oil only off the top will extend the life of the filter cartridges. CARTRIDGE REPLACEMENT: Indicated gauge pressure, not flow rate, will determine whether or not the filter cartridges should be replaced. When the gauge pressure reaches approximately 25PSI, the filters are loaded with dirt and should be discarded. On Cart type units if the filters get too dirty the pump relief valve automatically cuts in at 65psi pressure, at which time a small portion of total flow is recirculated internally in the pump to maintain this maximum pressure. Y-STRAINER SCREEN AND PUMP FILTER: The MM4 unit has a filter in the pump itself, this filter requires periodic cleaning. The NEF Cart mounted units have a Y-strainer screen located in the suction line to protect the pump against damage from larger foreign solids. Periodically remove the strainer element for cleaning and inspection. When the strainer becomes plugged it will impede flow of oil to the pump, resulting in unusually loud pump operation, reduction of flow and pressure. 1) Loosen and remove nut in Y strainer for removal of screen. 2) Clean and replace screen TROUBLE SHOOTING: 1) High initial pressure on gauge, caused by dense filter element, or high flow rate, high viscosity oil, or extremely dirty oil. Pressure can be reduced by using less dense filter element or increasing temperature of oil. 2) Air in discharge hose or light color of oil in discharge hose, caused by plugged suction strainer screen. Refer to strainer screen cleaning instructions. 3) Unusual loud noise, caused by pump cavitation which is the effect of a plugged strainer screen or end of suction hose is against bottom or sidewall of reservoir.

ITEM NUMBER 1 2 3 4 5 6 7 9 12 14 15 16 17 18 19 20 21 22 23 24 25 26 PARTS LIST FOR MM4-610-603 FILTER PART NUMBER MM4-1 SF-120-50-3 CI-20 A-9770 A-9771 23871-16-16 MM4-7 A-9420 MM4-12 MM4-14 EC286 MM4-16 MM4-17 MM4-18 MM4-19 MM4-20 NEF-610 NEF-603 5404-20 B-11410 MM4-11 MM4-26 DESCRIPTION PUMP FOR MM4 OIL FILTER SPIN ON FILTER HDS PRESSURE GAUGE FOR NEF11 BASE FOR MM4 HANDLE ASSEMBLY FOR MM4 1" ROUNDED ELBOW FOR NEF11 & MM4 RUBBER FEET FOR MM4 FILTER FEED TUBE LESS FITTINGS FOR MM4 FILTER (SET 1" X 3/4" HEX BUSHING FINGER GRIP CLIPS CRIMP ON HOSE CLAMPS 3/4" HOSE PER FT 3/4" FEMALE GH COUPLING MGH X 3/4" MALE PIPE ADAPTOR FGH X 1/2" MALE PIPE ADAPTOR MGH X 1/2" MALE PIPE ADAPTOR FOR NEF 61010MIC FILTER FOR NEF11 6033MIC FILTER FOR NEF11 1-1/4 HEX NIPPLE BRONZE BUSHING 1-1/4 X 1" 1" MALE X 3/4" FEMALE 90 ELBOW RED VINYL GRIP UOM SET FT 09/16/15