Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Installation Instructions Series 78-B/FHA Hold Open

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

7100SZ Series SafeZone Installation and Instruction Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Installation Instructions (07-08) CAUTION

Installation Instructions CAUTION

ASSA ABLOY Universal Door Closers

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

5600 Series Power Operator Installation and Instruction Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

TS93 EMF T/PT/TDE. Surface applied door closer

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

Power drill Center punch Wire stripper

Electromagnetic Door Holder/Releases

Installation Instructions

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

78-B/F Series. Traditional Door Closers

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

KEANE MONROE a member of the record group

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

9540 SERIES. Cast Iron Door Closer

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

* * Maintenance Kit

HIGH SECURITY CLOSERS SERIES

HOW TO TELL HAND OF DOOR:

HIGH SECURITY SERIES

51 Series Door Closers. An ASSA ABLOY Group brand

*ININST.1002* 1690 Touchbar. Index:

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

6900 PowerMatic Low Energy Power Operator Installation Instructions CAUTION CAUTION WARNING

WARNING: Make sure that (120V, 60Hz) input power is turned off at facility s main circuit breaker before proceeding with installation.

D O O R C L O S E R S

51 Series Door Closers. An ASSA ABLOY Group brand

8000 Series Tri-Style Non Handed Door Closer

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

626F Exit Device Trim Installation Instructions

Installation Instructions. Non Hold Open Models. Sized (Sizes 2,3,4,5) Weaker BC 9303BC 9304BC 9305BC. Stronger +

CONCEALED CLOSER SERIES

9000 Series Trinity The world's most intelligent door closer

D o o r C l o s e r s

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

ARCHITECTURAL DOOR HARDWARE DOOR STOPS & HOLDERS THRESHOLDS & GASKETING CATALOG

CONCEALED CLOSER SERIES

Headline. Overhead Door Holders/Stops

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

2904 Power Supply Installation Instructions I-EA00041

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

7570 SERIES Security Door Closer

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

CRAFTMASTER HARDWARE CO., INC Architectural. Product Guide

Door Closers. DC8000 Series

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

6900 Series PowerMatic Low Energy Power Operator

An ASSA ABLOY Group brand Series. Architectural Door Closer

*ININST.1039* 2390 Touchbar

Superior door control for rigorous, high-use applications 6000 LOW ENERGY OPERATOR CATALOG

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

High Security Closers Series

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Series. Non Hold Open Door Closers Parallel Arm. * conditions permitting. Parts. Mark and Drill Holes. Installation Sequence.

High Security Closers Series

RTS88. Overhead Concealed Door Closer

5300 Series 5300 SERIES

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

6900 Series PowerMatic. Low Energy Power Operator

9700/F9700 SERIES RIM EXIT DEVICE

NON-SIZED SIZED HANDED

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

KAWNEER 1686 EL CONCEALED EXIT DEVICE

DC3000 Series. Door Closers

DC5000 Series. Cam Action Door Closer

268, 269 & 278. Concealed Door Closers

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

Multi-feature closers with compact design, ideal for application on interior doors DOOR CLOSER CATALOG

An ASSA ABLOY Group brand. 400/4400 Series. Institutional Door Closer

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

NON-SIZED SIZED HANDED

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

Transcription:

Overhead Concealed Closer Holder Releasing Device with Rigid Slide Arm For wood or metal doors 1-3/4 to 2-1/4" (45-57mm) thick Hung in a hollow metal frame Standard butt hinges Typical Installation One track & closer position for all door opening angles Easy arm attachment Removable Frame Stop Required*-Not Shown Support Unit Models 7290 MPI (Infinite Hold Open Range) 7290 MPS (Selective Hold-Open Range) CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility of misapplication or misadjustment. Hinge or Pivot Left Hand Door-LH Right Hand Reverse-RHR Right Hand Door-RH Left Hand Reverse-LHR Hinge or Pivot *Not required when frame rabbet exceeds 2-3/16" (56mm). Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved.

Model 7290MPI/7290MPS Overhead Concealed With Rigid Slide Arm Templa- te Standard Butt Hinges Viewed From Above 4 Holes for Closer Fasteners 3/8 (9.5) 2 (50.8) 3/8 (9.5) 2 (50.8) 22-1/4 (565.2) 23 (584.2) 1-1/4 (31.8) 7/8 Dia. Hole (22.2) (Conduit) 1" (25.4) 20-1/4 Ref. (514.4) C L Conduit Conduit Box Dust Box (By frame mfr.) Reinforcement (By frame mfr.) 1/8 Ref. (3.2) C L Closer 5/32 to Centerline (4.0) Of Conduit Hole C L 3-3/4 (95.3) 1" (25.4) 1" (25.4) C L Hinge Viewed From Above 11/16 (to edge of cutout) (17.5) 8 (203.2) 24 (609.6) 21 (533.4) Frame Reinforcements 14 (355.6) 4 Holes for Track Fasteners 22 (558.8) 3/8 (9.5) deep cutout in shaded area 24 (609.6) 1-1/4 (31.8) 5/8 (15.9) Removable Frame Stop (By frame mfr.) 1-3/16 3/8 C L Door and Track Min. 1-3/4 (44.5) Max. 2-1/4 (57.2) (30.2) LEFT HAND DOOR 1/8 (3.2) Hinge 1/4 (6.4) C L Door and Track (9.5) 2-1/2 (63.5) NOTES: Do not scale drawing. Left hand door shown. Hardware dimensions shown (not cutouts). Dimensions are in inches (mm). Minimum door width 27" (685.8). Track 24" (609.6) long. Maximum width hinge is 5" (127). Fastener Use Preparation 1/4-20 machine screw #14 wood screw Track Installation Door Angle 110 180 With Cushion and stop block metal frame and metal door wood door Without Cushion and Stop block #7 (.201" dia.) or 5.10mm. drill 1/4-20 tap 7/32" or 5.5mm. drill Auxiliary Door Stop Required Opening greater than 110º See installation sequence on pages 4 & 5. Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved. Page 2

Model 7290MPI/7290MPS Overhead Concealed With Rigid Slide Arm Hinge Components Closer Assembly Cam Plug (MPS Unit only) Plug (MPS & MPI Unit) Conduit Box Cover Conduit Knockout (5) Dress Plate Mounting Screws 6-32 x 3/8 long L S S/D P B Spring Tube Conduit Box Short Dress Plate Positioning Screw Self Clinching Studs Mounting Plate Track Cushion and Stop Block Arm Flat Washer with countersink (4) Mounting screws 1-4-20 x 5/8 long (4) Track screws 1/4-20 x 7/16 or 14-10 x 1-1/4 long wood screws (2) Arm/track screw 1/4-20 x 3/4 long Hex drive with thread lock Long Dress Plate Arm Slider This end of slider (short side) toward cushion and stop block. Align Squares Stud Slider Screw Pack Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved. Page 3

Installation Sequence Note: Read instructions entirely prior to installation. Door/Frame Prep: Determine hand of door from illustration on page 1. Closer are handed. Hand of closer must match hand of door. Using template dimensions on page 2, locate holes and cutouts in frame and door, unless a separate template has been supplied for your application. Door: Prepare door for track. Drill and tap (4) holes for 1/4-20 machine screws. Frame: Prepare the frame for mounting closer. Drill and tap (4) holes for 1/4-20 machine screws or #14 wood screws. 1 23 Note: Generally on new construction hardware cutouts are made by suppliers at their shop. Wiring: Wiring of switch must be in compliance with N.E.C. Class 2 wiring specifications. Voltage to unit must be the same as shown on the unit: 24 Volts AC/DC or 120 Volts AC, 60hz. Voltage must be within a range of plus 10% and minus 15% of the unit's stated voltage. Pull hook-up box off mounting plate's self clinching studs, disconnect plugs and remove hook-up box cover. TEST SWITCH Terminal Block (+) (-) VI FUSE 0.75 AMPS (+) (-) 3 2 ALARM PANEL 1 DOOR HOLDER CIRCUIT Anchor conduit at 1 or 2 hook-up box knockouts. Secure power input leads to terminal lock, positions #1 and #2 as shown. SPECIFICATIONS 120VAC 24VAC 24VDC Voltage Current 132V MAX. 102V MIN. 26.4V MAX. 20.4V MIN. 120V 24V 24V 26.4V MAX. 20.4V MIN..035 AMPS.070 AMPS.070 AMPS OPTIONAL SELECTIVE HOLD OPEN SWITCH SOLENOID COIL FUSE Test switch (Push) Pos. (+) Black Neu. (-) white Reconnect sockets a. Connect plug with white leads from solenoid for MPI and MPS units. b. Connect plug with black leads from cam switch if used. Replace hook-up box cover and secure with (2) screws. Reattached hook-up box to mounting plate by aligning (2) holes at bottom of hook-up box with (2) self clinching studs. See illustration on page 3. Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved. Page 4

Installation Sequence con't Determine door opening angle See page 2 and below. Series 7290MPI: Infinite Hold Open units will hold door at virtually any degree of door opening from 5 to 175. Series 7290MPS: Selective Open Hold units are shipped with hold open set at approximately 85. Hold open can be set from 5 to 175. The hold open position can be increased or decreased by loosening the cam screw, rotating the cam to the new setting and tighten cam screw. See chart below for cam settings where hold open range will start. Align letters on hold open cam with V centerline of switch rocker. Choose row of letters on cam that are closest to the hinge side face of door. Mount closer to frame. Position spring tube away from hinge and mounting plate flush with frame rabbet. Secure to frame reinforcements with (4) 1/4-20 x 5/8 screws. Use care to avoid damaging or pinching wires. Install arm on closer pinion (see illustration below) Position arm counterbore facing down with index mark aligned with pinion index mark. Install onto pinion. Secure with washer and flat head arm screw with thread lock (see page 3). Left hand Arm in position (Bottom View) Pinion Mark Arm Index Mark Right hand Setting G H J K L M Door Angle 15º 30º 45º 60º 90º NOTE: Verify setting of cam before mounting closer to the frame. 135º Install track in door. Place the assembled track into door cutout with open side up, cushion andstop block if used, toward the hinge. Move slider to the opposite end of track (see illustration, page 3). Secure track with (4) 1/4-20 machine screws. Connect arm to track. Open door to approximately 5" (127mm), rotate arm to slider and place end on stud. Use a screw driver to align the square on slider s stud with the arm square (see illustration on page 3). Push down on arm to seat stud and to prevent stud from rotating. Secure with arm/track screw, 1/4-20 x 5/8 long flat head hex drive with thread lock. Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved. Page 5

Model 7290MPI/7290MPS Overhead Concealed With Rigid Slide Arm Closer Adjustment CAUTION: Do not back valves out of closer or a leak will result. Standard Door Closer Door Closing Controls "L" Range "S" Range Door Opening Controls "BC" Range Never Close Completely Closing Power Adjustment MODEL SIZE HAND 7290 4 RH LATCH SWEEP BC POSITION BC INCREASE POWER ADJUST DECREASE Mounting Base Plate Closing Controls Opening Controls Latch Sweep Delayed Action Backcheck Closer Controlsaccessible through mounting plate for closer adjustment: Use 1/8" (3mm.) hex-key for valve adjustments. Use standard screwdriver for power adjustment. Power Adjustmentpermits increasing door closing force. Controlled by slotted screw marked "P.A." Closing Speedcontrolled by valves marked "SWEEP" and "LATCH". Attention: Adjust closing speed time to between 4 to 7 seconds from 90. Use of the door by handicapped, elderly, or small children may require greater closing time. Backcheckcushions or slows the opening of a door that is forced to travel faster than conditions require. Backcheck controlled by valves marked "BC POSITION" (open for backcheck start at a greater door opening angle) and "BC" (for adjusting backcheck intensity). Never close "BC" valve completely. Optional Enhanced Backcheckprovides adjustable backcheck intensity beginning at approximately 15 of the door opening cycle. Backcheck positioning valve is omitted when this feature is provided. Hold Open Check. Turn power to the unit On. Open door to the hold open position. Manually pull door out of hold open and release, door should close. FUSE Test switch (Push) Pos. (+) Black Neu. (-) white Hook-Up Box Testing. Open door to the hold open position. Depress Test Switch button on Hook-up Board, accessible through cutout in hook-up box and mounting plate (see illustration at right). Door should close. Install short and long dress plates with (5) 6-32 screws. 3000 Highway 74 East Monroe, NC 28112 Tel: (877)- 974-2255 Fax: (800)-338-0965 www.nortondoorcontrols.com Norton is a registered trademark of Yale Security Inc., an Group company. Copyright 2002, 2014 Yale Security Inc., an Group company. All rights reserved. Page 6