Linear Luminaire for Fluorescent Lamps

Similar documents
Linear Luminaire with LED

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Pendant Light Fitting IEC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Operating Instructions

Emergency Luminaire with LED Series EXLUX 6409/1

LED Linear Luminaire Series EXLUX 6402

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Operating Instructions

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Operating Instructions

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Luminaire with LED

Operating Instructions

7 Lighting Technology

Operating Instructions

Compact Sheet-Steel Light Fittings Series 6114/1

Universal spotlight LED

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plug and Socket Devices SolConeX 16 A Series 8570

Sheet-Steel Light Fittings Series 6014 / 6414

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Floodlight LED Series 6125

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

OPERATING INSTRUCTIONS

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

7 Lighting Technology

Control Buttons / Switches for Panel Mounting Series 8003

Floodlight Series 6121

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Floodlight LED Series 6525

Compact Sheet-Steel Light Fittings Series 6114

Terminal Boxes Series 8125

Floodlight LED Series 6525

Sheet Steel Emergency Light Fitting Series 6018

Explosion protected terminal boxes type, GHG 72.

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Ex UPS standard Series 8265

7 Lighting Technology

Load disconnect switch Series 8146/5-V11

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Position Switches Series 8074/2

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Position Switches Series 8060/2

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Operating Instructions

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

INSTRUCTION MANUAL (ATEX / IECEx)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Position Switches Series 8070/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Zone 1 Linear Range - Installation Guide

ILED Aquarius Illuminated Windsock. User Manual

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Floodlight Series 6521/4

Operating Instructions Flexdip CYA112

Solenoid Operator 0516 / 1216

Ex m Solenoid Operator Type 0519

Linear fluorescent luminaire LED V-CG-S

Control Buttons Series 8082

INSTRUCTION MANUAL (ATEX / IECEx)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

OPERATING INSTRUCTIONS

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Terminal Boxes Series 8125

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Assembly and Maintenance Manual Type AS

Operating instructions Solenoid interlock EX-AZM About this document. Content

Assembly and Maintenance Manual Type ASNU

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

ACROBAT SWING STAND MODEL

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Operating Instructions (Translation)

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

Transcription:

Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com

General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3 1.3 Conformity with standards and regulations...3 2 Explanation of the symbols...3 2.1 Symbols in these operating instructions...3 2.2 Warning notes...3 2.3 Symbols on the device...4 3 Safety notes...4 3.1 Operating instructions storage...4 3.2 Safe use...4 3.3 Intended Use...5 3.4 Modifications and alterations...5 4 Function and device design...5 4.1 Function...5 4.2 Device design...6 5 Technical data...6 6 Transport and storage...10 7 Mounting and installation...10 7.1 Dimensions / fastening dimensions...10 7.2 Mounting / dismounting, operating position...12 7.3 Installation...16 8 Commissioning...19 9 Operation...19 9.1 Troubleshooting...19 10 Maintenance and repair...20 10.1 Maintenance...20 10.2 Returning the device...22 11 Disposal...22 12 Accessories and Spare parts...22 1 General Information 1.1 Manufacturer R. STAHL Schaltgeräte GmbH Business Unit Lighting & Signalling Nordstr. 10 99427 Weimar Germany Phone: Fax: Internet: E-mail: +49 3643 4324 +49 3643 4221-76 www.stahl-ex.com info@stahl.de R. STAHL Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg Germany Phone: Fax: Internet: E-mail: +49 7942 943-0 +49 7942 943-4333 www.stahl-ex.com info@stahl.de 2 Linear Luminaire for Fluorescent Lamps

1.2 Information regarding the operating instructions ID-No.: Publication Code: The original instructions are the English edition. They are legally binding in all legal affairs. 1.3 Conformity with standards and regulations See certificates and EC Declaration of Conformity: www.stahl-ex.com. The device has IECEx approval. See IECEx homepage: http://iecex.iec.ch/ Further national certificates can be downloaded via the following link: http://www.r-stahl.com/downloads/certificates.html. 2 Explanation of the symbols 2.1 Symbols in these operating instructions Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Explanation of the symbols Danger due to energised parts 2.2 Warning notes Warning notes must be observed under all circumstances, in order to minimize the risk due to construction and operation. The warning notes have the following structure: Signalling word: DANGER, WARNING, CAUTION, NOTICE Type and source of danger/damage Consequences of danger Taking countermeasures to avoid the danger/damage Linear Luminaire for Fluorescent Lamps 3

Safety notes 2.3 Symbols on the device 3 Safety notes DANGER Danger to persons Non-compliance with the instruction results in severe or fatal injuries to persons. WARNING Danger to persons Non-compliance with the instruction can result in severe or fatal injuries to persons. CAUTION Danger to persons Non-compliance with the instruction can result in light injuries to persons. NOTICE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Symbol 05594E00 02198E00 Meaning CE marking according to the currently applicable directive. According to marking, device approved for hazardous areas. 3.1 Operating instructions storage Read the operating instructions carefully and store them at the mounting location of the device. Observe applicable documents and operating instructions of the devices to be connected. 3.2 Safe use Read and observe the safety notes in these operating instructions! Observe characteristic values and rated operating conditions on the rating and data plates! Observe additional information plates on the device! Use the device in accordance with its intended and approved purpose only! We cannot be held liable for damage caused by incorrect or unauthorized use or by non-compliance with these operating instructions. Before installation and commissioning, make sure that the device is not damaged! Work on the device (installation, maintenance, overhaul, repair) may only be carried out by appropriately authorized and trained personnel. 4 Linear Luminaire for Fluorescent Lamps

Function and device design 3.3 Intended Use The luminaire is equipment for lighting areas, work spaces and objects can be used indoors and outdoors for stationary mounting for use in Zones 1, 21, 2, 22 and in the safe area 3.4 Modifications and alterations 4 Function and device design 4.1 Function DANGER Explosion hazard due to modifications and alterations to the device! Non-compliance results in severe or fatal injuries. Do not modify or alter the device. No liability or warranty for damage resulting from modifications and alterations. DANGER Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only according to the operating conditions described in these operating instructions. DANGER Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only according to the operating conditions described in these operating instructions. for lighting areas, work spaces and objects switching off the equipment by means of a central lock (standard version) when the luminaire is opened Linear Luminaire for Fluorescent Lamps 5

Technical data 4.2 Device design 4 1 - Lamp holder 5 - Connection terminal (left standard, right with through wiring) 2 - Ballast 6 - Luminaire enclosure 3 - Translucent cover 7 - Reflector plate 4 - Cable gland 5 Technical data 1 2 5 6 7 3 15480E00 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx PTB 13.0003 Ex db eb IIC T4 Gb Ex tb IIIC T80 C Db Europe (ATEX) Gas and dust PTB 13 ATEX 2004 Certifications and certificates Certificates E II 2 G Ex db eb IIC T4 Gb E II 2 D Ex tb IIIC T80 C Db IECEx, ATEX, Brazil (INMETRO), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Belarus (TR) 6 Linear Luminaire for Fluorescent Lamps

Technical Data Electrical data Ballast Power factor cos p 6001/...-...0-..-... 6001/...-...1-..-... Lamp start Cold start Cold start Voltage 220... 240 V AC 220... 240 V AC Voltage DC during switching on 198 264 V DC 104 264 V DC Voltage DC during operation 176 264 V DC 198 264 V DC Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC 1 lamp 2 lamps Lamp IEC 60081 IEC 60081 standard Lamp power 18, 36, 58 W 18, 36, 58 W Nominal current 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 2 40 W cos p ) 0.97 capacitive; no additional compensation required Technical data 6001/...-...2-..-... 6001/...-...3-..-... 6001/...-...6-..-... Lamp start Cold start Cold start Cold start Voltage 110... 240 V AC 110... 240 V AC 120... 277 V AC Voltage DC during switching on 104 264 V DC 104 264 V DC 113 294 V DC Voltage DC during operation 104 264 V DC 104 264 V DC 113 294 V DC Frequency 0 / 50 60 Hz 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC 1 lamp 2 lamps 2 lamps Lamp IEC 60081 IEC 60081 ANSI C78.81 standard Lamp power 18, 36 W 18, 36 W 17, 32, 40 W Nominal current 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 17 W, 80 155 ma 2 x 17 W, 160 305 ma 1 x 32 W, 135 285 ma 2 x 32 W, 270 570 ma 1 x 40 W, 160 360 ma Linear Luminaire for Fluorescent Lamps 7

Technical data Technical Data Disconnection of the light Luminous characteristics Measures for light guidance When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. Standard: Deep bowl, reflector of the lamp is white Lateral dazzle limitation in the lamp cover Ambient conditions Operating temperature range Through wiring Type without with 6001/52.- 0-..-... -30... +60 C -30... +50 C 6001/52.- 1-..-... -30... +60 C -30... +50 C 6001/52.-...2-..-... -30... +45 C -30... +40 C 6001/52.- 3-..-... -30... +45 C -30... +40 C 6001/54.- 0-..-... -30... +55 C -30... +50 C 6001/54.- 1-..-... -30... +55 C -30... +50 C 6001/54.- 2-..-... -30... +45 C -30... +40 C 6001/54.- 3-..-... -30... +45 C -30... +40 C 6001/56.- 0-..-... -20... +55 C -20... +50 C 6001/56.- 1-..-... -20... +55 C -20... +50 C 6001/53.- 6-..-... -30... +40 C -30... +40 C 6001/55.- 6-..-... -30... +40 C -30... +40 C 6001/57.- 6-..-... -20... +40 C -20... +40 C The lowest ambient temperature when used with breather is -20 C. Mechanical data Degree of protection IP66 / IP67 (IEC 60598) Protection class I (with internal PE connection) Impact strength IK10 (IEC 62262) (IK code) Material Enclosure Enclosure Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Translucent cover Polycarbonate Seal Silicone foam gasket in the lamp cover Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover 8 Linear Luminaire for Fluorescent Lamps

Technical Data Montage / Installation Cable glands Connection Through wiring Assembly Technical data Standard luminaire Plastic: 2 x M25 x 1.5 cable gland 8161 and 1 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Standard: Special: Through wiring without Spring clamp terminals 5-pole: L1, L2, L3, N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) 4 mm 2 finely stranded without core end sleeve only (2 free clamping units for each pole available) Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2 x 1.5... 6 mm 2 (solid); 2 x 1.5... 4 mm 2 (finely and extra finely stranded) Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected on the opposite sides. Terminals: see Techn. data Wiring cross-section: 2.5 mm 2 for max. 16 A Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). For outdoor mounting, a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 18 W: 320... 480 mm; 36 W / 58 W: 670... 930 mm) Linear Luminaire for Fluorescent Lamps 9

Transport and storage 6 Transport and storage Transport and store the device only in the original packaging. Store the device in a dry place (no condensation) and vibration-free. Do not drop the device. 7 Mounting and installation DANGER Explosion hazard due to incorrect installation of the device! Non-compliance results in severe or fatal injuries. Carry out installation strictly according to the instructions and national safety and accident prevention regulations to maintain the explosion protection. Select and install the electrical device so that explosion protection is not affected due to external influences, i.e. pressure conditions, chemical, mechanical, thermal and electric impact such as vibration, humidity and corrosion (see IEC/ 60079-14). The device must only be installed by trained qualified personnel who is familiar with the relevant standards. 7.1 Dimensions / fastening dimensions Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations b L1 L2 M25 x 1,5 L3 M25 x 1,5 Dimensions Luminaire 17/18 W 32/36 W 40/58 W L1 700 [27.56] 1310 [51.57] 1610 [63.39] L2 1) 400 [15.75] 800 [31.50] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] h1 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance 15440E00 EXLUX 6001 Standard luminaire 10 Linear Luminaire for Fluorescent Lamps

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 30 [1,18]. 9 Mounting rail 74 [ 2, 91] 32 [1,26] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] Ring bolt fitted in insert nut of the luminaire 10x15 [0,35] ø 20 [ø 0,79] A 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 162 [6,38] 215 [ 8.46] 86 [ 3, 39] 24 [0,95] 12 [ 0, 47 ] 18,50 [ 0, 73 ] 6,10 [0,24] 172 [6,77] 15778E00 Mounting and installation 15782E00 15781E00 15783E00 Mounting bracket fitted in mounting rail 30,50 [ 1, 20 ] 13 [0,51] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] Pipe clamp fitted in mounting rail 143 [5,63] 15779E00 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] 15780E00 Wall mounting bracket fitted in mounting rail 198 [7,80] 160 [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 90 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Bracket for wall mounting with pipe section 03257E00 Linear Luminaire for Fluorescent Lamps 11

Mounting and installation Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations Dimension Light 17/18 W 32/36 W L1 978 [38.50] 1587 [62.48] L2 390 [15.35] 338 [13.31] EXLUX 6001 with pole mounting sleeve 7.2 Mounting / dismounting, operating position DANGER Explosion hazard due to electrostatic discharge Non-complicance results in severe or fatal injuries. 17755E00 Do not use the luminaire in strong charge generating environments! The following processes/activities should be avoided: accidental friction particle currents The luminaire is suitable for wall and ceiling mounting. Wall mounting must be performed with the central lock directed downwards. The mounting position with light emission upwards is not allowed when mounted outdoors. For outdoor use, we recommend to install a 8162/1 breather from R. STAHL Schaltgeräte GmbH. The breather guarantees compliance with degree of protection IP64 in all mounting positions. 12 Linear Luminaire for Fluorescent Lamps

Mounting and installation DANGER Explosion hazard due to inadmissible heating! Non-compliance results in severe or fatal injuries. Avoid external heat sources and/or direct sunlight (risk of change of temperature class or change of maximum permissible surface temperature). Do not exceed the maximum ambient temperature due to external heat sources (premature failure of equipment). Suspension at fixed mounting points 15446E00 Suspension at moveable assembly parts L L4 L2 L Version L2 [mm] 17/18 W 400 32/36 W 800 40/58 W max. screw-in depth 10 mm L L4 L 15442E00 Mounting bracket Top rail Version L4 [mm] L [mm] 17/18 W 320 80 32/36 W 670 130 40/58 W 15447E00 Lateral mounting pockets for variable suspension points. When mounting the luminaire using top rails, ensure that the mounting surface is flat. Otherwise, the enclosure might be mounted in a warped/twisted way. The result is leakage of the luminaire and difficulties in replacing the translucent cover. Linear Luminaire for Fluorescent Lamps 13

Mounting and installation Pole mounting Pole mounting using pipe clamps Version L4 [mm] L [mm] 17/18 W 320 80 32/36 W 670 130 40/58 W 15455E00 For pipe clamp mounting, use the solution of R. STAHL Schaltgeräte GmbH with integrated mounting rail providing reliable and stable four-point fixing! In case of point suspension using pipe clamps, R. STAHL Schaltgeräte GmbH does not guarantee the strength and tightness of the luminaire! Pole mounting using pole mounting sleeve Only for luminaires length 700 mm and 1310 mm. L L4 L 15443E00 17761E00 17762E00 14 Linear Luminaire for Fluorescent Lamps

Wall bracket mounting L L4 L 15515E00 Version L4 [mm] L [mm] 17/18 W 320 80 32/36 W 670 130 40/58 W Continuous row mounting 06250E00 1 2 10 06033E00 x 15 1: Rail profile 2: Luminaire 15517E00 800 mm / 31.50 " (32 W / 36 W) 400 mm / 15.74 " (17 W / 18 W) Mounting and installation 200 mm / 7.87 " 700 mm / 27.56 " (17 W / 18 W) 1310 mm / 51.57 " (32 W / 36 W) 1610 mm / 63.39 " (40 W / 58 W) R.STAHL Schaltgeräte GmbH rail profile for continuous row mounting of the linear fluorescent luminaires EXLUX It facilitates the row mounting and installing of luminaires. The rail profile can be also used as cable duct. Always use mounting rails for mounting to adjust the luminaires to the hole matrix of the rail profile. 15444E00 Linear Luminaire for Fluorescent Lamps 15

Mounting and installation 7.3 Installation 7.3.1 Opening and Closing of the Enclosure DANGER Risk of electric shock! Risk of fatal injuries! Luminaires without switch must not be opened when they are supplied with power (see information plate on the lock)! Recommendation Opening and closing of the luminaire by using a socket wrench from R. STAHL Schaltgeräte GmbH. 15448E00 170 90 165 15451E00 Remove the closing cap of the central lock. Turn the central lock using a socket wrench M8, wrench size 13, by 90 to the left as far as it will go. Swivel down the translucent cover. Proceed in reverse order to close. The seal of the translucent cover must lie correctly on the sealing edge. Push the closing cap onto the central lock opening (dust protection). 15436E00 Note: Version without switch: Disconnect the luminaire from the power supply and secure it against being switched on again. Version with switch: The luminaire is positively disconnected from the power supply by actuating the central lock. In open end position and with translucent cover swivelled down, a restart lock-out device prevents the central lock from being actuated. Please do not use force! When the translucent cover is closed, the central lock is released. 16 Linear Luminaire for Fluorescent Lamps

Opening and closing the reflector plate 1 2 Mounting and installation 7.3.2 Electrical connections Electrical connection Observe the maximum clamping possibility of the connecting terminals (see chapter "Technical data"). For optional screw-type terminals, two conductors per clamping unit can be clamped (ingoing and outgoing wiring). Note: Clamping must be carried out precisely! Do not clamp any part of the conductor insulation! Do not interchange the conductors! Observe the technical regulations when connecting the conductor! Clamp the conductor firmly. The terminal cover of optional screw-type terminals does not have to be removed to clamp the conductor! Optional screw-type terminals: Firmly tighten screws (tightening torque 2 Nm, for unused clamping units 0.7 Nm)! Connection terminals Standard: Spring clamp terminals up to 4 mm 2 Stripping length: 10... 11 mm N N 15512E00 Optional: Screw-type terminals up to 4 mm 2 finely and extra finely stranded, and 6 mm 2 solid Stripping length: 10... 11 mm 1 Open the reflector plate by pressing the safety latch. 2 Swivel down the reflector plate. When closing, flip up the reflector plate and snap it into place. L1, L2, L3 = Phase N = Neutral conductor PE = Protective conductor L1 L3 L2 L1 L2 L3 15516E00 15438E00 Linear Luminaire for Fluorescent Lamps 17

Mounting and installation Through wiring NOTE Through wiring with 2.5 mm 2 cross-section for max. 16 A. 7.3.3 Cable entries The standard luminaire is delivered with 3 lead-in holes, 2 cable glands and 2 stopping plug. Please observe the tightening torque for luminaires with installed cable glands and stopping plugs from R. STAHL Schaltgeräte GmbH. Tightening torque Connection thread Pressure screw Cable gland 8161 M20 x 1.5 2.3 Nm 1.5 Nm M25 x 1.5 3.0 Nm 2.0 Nm Stopping plugs 8290 M20 x 1.5 1.0 Nm M25 x 1.5 1.5 Nm Luminaires with approved cable glands and stopping plugs; not supplied by R. STAHL Schaltgeräte GmbH WARNING Cable glands and stopping plugs which are not approved. Explosion protection is impaired! Only use separately certified cable glands and stopping plugs. Please note: the required dust resistance! the required type of protection! the required temperature resistance! the IP degree of protection according to the rating plate! the operating instructions of the cable glands and stopping plugs! the required tightening torques! the range of the permissible cable diameter! 18 Linear Luminaire for Fluorescent Lamps

Commissioning 8 Commissioning Before commissioning, ensure that the device has been installed according to regulations. the power supply voltage and the rated operational voltage are identical. the required cable diameter for cable glands has been used. the cable entries and stopping plugs have been securely tightened. the cables are correctly connected. the connection has been performed correctly. all screws and nuts are tightened according to regulations. the connection chamber is clean. the device is not damaged. no foreign bodies are inside the device. the device is sealed according to regulations. 9 Operation 9.1 Troubleshooting DANGER Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Check the device for proper installation and function before commissioning. Comply with the national regulations. NOTE Condensation due to specific environmental and operating conditions condensation cannot be avoided completely. operate the luminaire continuously or periodically over extended periods of time! avoid thermal bridges! Cause The lamp was incorrectly inserted. The lamp is defective. The ballast is defective. The switch is defective. The lamp reached its end of service life. Measure Insert the lamp correctly. Replace the lamp. Replace the ballast. Replace the switch. Replace the lamp. If the error cannot be eliminated using the mentioned procedures: Contact R. STAHL Schaltgeräte GmbH. For fast processing, have the following information ready: Type and serial number Purchase information Error description Intended use (in particular input / output wiring) Linear Luminaire for Fluorescent Lamps 19

Maintenance and repair 10 Maintenance and repair 10.1 Maintenance WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work! Non-compliance can result in severe injuries and material damage. Work performed on the device must only be carried out by appropriately authorized and qualified electricians. Observe the relevant national regulations in the country of use. Determine the type and extent of inspections in compliance with the relevant national regulations. Adapt inspection intervals to the operating conditions. The following tests and measures must be carried out during regular maintenance. Check the permissible ambient temperature the enclosure components for formation of cracks and damage. its intended use Measures If exceeding the permissible ambient temperature or falling below the device must be taken out of operation. Replace the exchangeable enclosure components. If the enclosure components are non-exchangeable, the device must be taken out of operation. If the device is not used according to its intended use, it must be taken out of operation. if the conductors are clamped properly the cables for ageing and damage the seals for ageing and damage clamp loose conductors tightly. replace damaged or aged cables. replace damaged, aged and porous seals and completely change enclosure components with foamed seal. 20 Linear Luminaire for Fluorescent Lamps

Maintenance and repair 10.1.1 Replacement of lamps Only use fluorescent lamps with pins made of brass. Note: The lamp bases must be undamaged. The holders have a springy length compensation of 2.5 mm each. Observe the fit of the lamp; the lamp fit will be locked after turning the lamp. Replace the lamps in due time. Observe the service life specified by the manufacturer. EOL- safety shutdown: The EB switches off the lamp at the end of the service life. 10.1.2 Replacing the luminaire cover 180 06058E00 06048E00 Insert both lamp bases of the lamp into the holder slots as far as possible. Put the lamp into operating position by turning it to the right or to the left. Dismounting is carried out in reverse order. Open the luminaire. Swivel the translucent cover backwards by 180. Lift the translucent cover to detach it from the hinge. Insert new translucent cover into the hinge. All hinges must engage properly. Close the luminaire. Observe safety notes! 10.1.3 Cleaning NOTE The luminaire is marked with the warning "Clean with damp cloth only". Clean the device only with a damp cloth. Use water or mild cleaning agents. Do not use abrasive, scratching and aggressive detergents or solvents. Linear Luminaire for Fluorescent Lamps 21

Disposal 10.2 Returning the device Use the "Service form" to return the device when repair/service is required. On the internet site "www.stahl-ex.com" under "Downloads > Customer service": Download the service form and fill it out. Send the device along with the service form in the original packaging to R. STAHL Schaltgeräte GmbH. 11 Disposal Observe national and local regulations and statutory regulation regarding disposal. Separate materials when sending it for recycling. Ensure environmentally friendly disposal of all components according to the statutory regulations. 12 Accessories and Spare parts NOTE Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage www.stahl-ex.com. 22 Linear Luminaire for Fluorescent Lamps