Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Similar documents
Servo-operated 2/2-way solenoid valves Type EV220A

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Assisted lift operated 2/2-way solenoid valves Type EV251B

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valves for drinking water Types EV220BW and EV228BW

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Servo-operated 2/2-way solenoid valves for high pressure

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Solenoid valve Types EV220B 15 - EV220B 50

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Solenoid valves 2/2-way servo operated type EV220B 15 50

Assisted lift operated 2/2-way solenoid valves Type EV250B

Servooperated. 2/2-way solenoid valves EV220A. The Home of Control & Automation in Ireland

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

2/2-way assisted lift operated solenoid valve type EV250B

Solenoid valves 3/2-way direct-operated Type EV310A

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210A DKACV.PD.100.A B1023. August 2001

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

Solenoid valves VZWP, servo-controlled

Solenoid valves Type EVU

Solenoid valves 2/2-way direct-operated Type EV210B

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Solenoid valves VZWM-L, NPT

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

2/2-way Solenoid Valve for liquids and gases

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Solenoid System FLANGE MOUNTING VERSION

2/2-way Solenoid Valve with servo diaphragm

PILOT OPERATED, 2/2 WAY, NORMALLY CLOSED, G 3/4 - G1. Pressure. Pressure Maximum For DC Voltage. Flow Coeffient. Maximum. For AC Voltage. L/m.

Easy. Core Industrial Products for Distributors and Wholesalers. selection of future proof products. iasupport.danfoss.com

Solenoid valves VZWM-L

Pressure switches hex 24

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Direct-acting 2/2- or 3/2-way pivoted armature valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Solenoid valve VDHT standard BSP (British Standard Pipe)

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Solenoid valves VZWM-L

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread

2/2 Pressure operated valves

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

Solenoid valves Type EVU for fluorinated refrigerants

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

3/2-way Solenoid Valve for pneumatics

EVI 5 S13 Solenoid System

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valves VZWF, force pilot operated

Condensed Catalog 2006 North America

Solenoid valve 2/2 way N.C. With pilot control

High Pressure Valves

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 6213 EV, 6281 EV

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Pilot valves for servo operated main valves

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Pilot valves for servo opereated main valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Direct-acting 2/2-way plunger valve

Solenoid Valves. Product Information. It s all at Albion

Coils for solenoid valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

3/2-way Solenoid Valve, direct-acting, NC or NO

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Solenoid coils. Data sheet

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

Solenoid coils. Data sheet

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

16mm miniature rocker solenoid valve with isolating diaphragm for special applications

Technical Data Sheet

Pressure switch hex 27

Technical Principles of Valves

Solenoid valve Types EVR 2 EVR 40 NC/NO

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

Solenoid coil Types BB, BE, BF, BG, and BN

Pilot valves for servo operated main valves

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Solenoid coil for control in potentially explosive areas Type BZ

COMPACT VALVE - 1/2 Series DS2

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Pneumatic Valve 4V100 Series

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

System 6. ü ( System 6

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Standard valves to ISO Product range overview

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Transcription:

Data sheet Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions EV220W is a range of compact indirect servo- operated 2/2 way solenoid valves with connections from 3/8 to 2, especially designed for use within a limited space. This range has been designed for use within various markets, such has, the Industrial and HVAC markets, which demand an easy and reliable valve that is easy to setup and use. Features and versions y For water, oil, compressed air and similar neutral media y NBR for air and oil y EPDM for water and brine y WRAS approved with EPDM sealing; 0 90 C NC version 0 50 C NO version y DN 10 50 y Differential pressure: From 0.2 10 bar y Media temperatures: From -30 100 C y Viscosity: Up to 50 cst y Ambient temperatures: From -40 50 C y Standard equipped with clip on coil for dry and humid environments y Enclosure: IP65 y NC version, standard for 3/8 2 valve sizes y NO version, standard for 3/8 2 valve sizes y Complete coil voltage: 230 V AC, 24V AC, 24 V DC IC.PD.100.W7.02 1

Brass valve body, NC. NBR seal. Clip on coil and cable plug y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 (Notified body by Semko) - Pressure Equipment Directive 2014/68/EU - RoHS Directive 2011/65/EU Connection ISO228/1 G 3/8 Seal material Orifice size K v - value Media temperature Differential pressure min. to max. [mm] [m³/h] [ C] [bar] 10 1.6-10 80 0.2 10 G 1/2 14 4-10 80 0.3 10 G 3/4 18 7-10 80 0.3 10 NBR G 1 22 7-10 80 0.3 10 G 1 1/4 32 15-10 80 0.3 10 G 1 1/2 40 18-10 80 0.3 10 G 2 50 32-10 80 0.3 10 Coil voltage/power consumption AS coil 1 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. 042U426132 042U426119 042U426102 042U426432 042U426419 042U426402 042U426532 042U426519 042U426502 042U426632 042U426619 042U426602 042U426732 042U426719 042U426702 042U426832 042U426819 042U426802 042U426932 042U426919 042U426902 ON OFF 24h 3 ) In heating applications it is recommended that the Water Oxygen content should not exceed 0.1mg / L in the temperature range 40 80 C. Operating in such conditions may reduce valve lifetime. IC.PD.100.W7.02 2

Brass valve body, NO. NBR seal. Clip on coil and cable plug y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 (Notified body by Semko) - Pressure Equipment Directive 2014/68/EU - RoHS Directive 2011/65/EU Connection ISO228/1 G 3/8 Seal material Orifice size K v - value Media temperature Differential pressure min. to max. [mm] [m³/h] [ C] [bar] 10 1.6-10 80 0.2 10 G 1/2 14 4-10 80 0.3 10 G 3/4 18 7-10 80 0.3 10 NBR G 1 22 7-10 80 0.3 10 G 1 1/4 32 15-10 80 0.3 10 G 1 1/2 40 18-10 80 0.3 10 G 2 50 32-10 80 0.3 10 Coil voltage/power consumption AS coil 1 ) It is recommended to use a filter in front of the valve. 2 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. 042U436132 042U436119 042U436102 042U436432 042U436419 042U436402 042U436532 042U436519 042U436502 042U436632 042U436619 042U436602 042U436732 042U436719 042U436702 042U436832 042U436819 042U436802 042U436932 042U436919 042U436902 ON OFF 24h IC.PD.100.W7.02 3

Brass valve body, NC. EPDM seal. Clip on coil and cable plug y WRAS ; see below, 0-90 C y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 (Notified body by Semko) - Pressure Equipment Directive 2014/68/EU - RoHS Directive 2011/65/EU Connection ISO228/1 G 3/8 Seal material Orifice size K v - value Media temperature Differential pressure min. to max. [mm] [m³/h] [ C] [bar] 10 1.6-30 100 0.2 10 G 1/2 14 4-30 100 0.3 10 G 3/4 18 7-30 100 0.3 10 G 1 EPDM 22 7-30 100 0.3 10 G 1 1/4 32 15-30 100 0.3 10 G 1 1/2 40 18-30 100 0.3 10 G 2 50 32-30 100 0.3 10 Conformity Coil voltage/ power consumption AS coil 1 ) WRAS approved in the temperature range 0 90 C. 2 ) It is recommended to use a filter in front of the valve. 3 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. 042U471032 042U471019 042U471002 042U471432 042U471419 042U471402 042U471832 042U471819 042U471802 042U472232 042U472219 042U472202 042U473232 042U473219 042U473202 042U474032 042U474019 042U474002 042U475032 042U475019 042U475002 ON OFF 24h IC.PD.100.W7.02 4

Brass valve body, NO. EPDM seal. Clip on coil and cable plug y WRAS ; see below, 0-50 C y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 (Notified body by Semko) - Pressure Equipment Directive 2014/68/EU - RoHS Directive 2011/65/EU Connection ISO228/1 G 3/8 Seal material Orifice size K v - value Media temperature Differential pressure min. to max. [mm] [m³/h] [ C] [bar] 10 1.6-30 100 0.2 10 G 1/2 14 4-30 100 0.3 10 G 3/4 18 7-30 100 0.3 10 G 1 EPDM 22 7-30 100 0.3 10 G 1 1/4 32 15-30 100 0.3 10 G 1 1/2 40 18-30 100 0.3 10 G 2 50 32-30 100 0.3 10 Conformity Coil voltage/ power consumption AS coil 1 ) WRAS approved in temperature range 0 50 C. 2 ) It is recommended to use a filter in front of the valve. 3 ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. 042U413032 042U413019 042U413002 042U413332 042U413319 042U413302 042U413432 042U413419 042U413402 042U413532 042U413519 042U413502 042U413632 042U413619 042U413602 042U413732 042U413719 042U413702 042U413832 042U413819 042U413802 ON OFF 24h IC.PD.100.W7.02 5

Technical data, NC and NO Type EV220W 10 EV220W 14 EV220W 18 EV220W 22 EV220W 32 EV220W 40 EV220W 50 Time to open [ms] 1 ) 50 100 200 200 2500 4000 5000 Time to close [ms] 1 ) 300 400 500 500 4000 6000 10000 Capacity, K v [m 3 /h] 1.6 4 7 7 15 18 32 1 ) Times are indicative and apply to water. Exact times will depend on pressure conditions. Max working pressure (MWP) 10 bar Max test pressure EV220 W 10 50 EV220 W 14-50 25 Ambient temperature -40 50 C Medium viscosity Max. 50cSt Valve body Brass W. no. 2.0401 Armature Stainless steel W. no. 1.4105 / AISI 430FR Armature stop Stainless steel W. no. 1.4105 / AISI 430FR Materials Armature tube Stainless steel W. no. 1.4303 / AISI 305 Spring Stainless steel W. no. 14310 / AISI 301 O-ring NBR / EPDM Valve plate NBR / EPDM Diaphragm NBR / EPDM IC.PD.100.W7.02 6

H Data sheet Indirect servo-operated 2/2-way solenoid valves, Type EV220W 10 - EV220W 50 Dimensions and weight: Type Weight with AS coil [kg] L [mm] L 1 [mm] B [mm] B 1 [mm] H 1 [mm] H [mm] Coil AS NC NO EV220W 10 0.56 51 50 50 70 13 77 81 EV220W 14 0.62 58 50 58 70 13 78 82 EV220W 18 0.84 90 50 58 70 18 79 83 EV220W 22 1.12 90 50 58 70 22 84 84 EV220W 32 2.12 120 50 82 70 27 96 96 EV220W 40 3.32 130 50 95 70 32 106 106 EV220W 50 4.42 162 50 113 70 37 112 112 Dimensions L1 B1 H1 L B Mounting angle Max.90 Max.90 Max.90 Max.90 IC.PD.100.W7.02 7

AS/AZ, Compact UL recognised, clip-on coils y Enclosure: Up to IP65 / NEMA 4 y Used with EV220W y In accordance with: - RoHS Directive 2011/65/EU - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 y UL recognized Type AS024CS -40 50 AS230CS -40 50 Ambient Power Supply voltage temperature Voltage Frequency consumption variation [ C] [V] [Hz] [W] [VA] 24-10%, +6% 50 9.5 18 24-10%, +6% 60 7.0 14 230-10%, +6% 50 8.0 16 208-240 ±6% 60 7.0 14 042N7608 042N7601 AZ012DS -40 50 12-10%, +6% DC 6.0 042N7616 AZ024DS -40 50 24-10%, +6% DC 6.5 042N7617 Technical data Design In accordance with UL 429 Insulation of coil windings Class H according to IEC 85 Connection Spade connector in accordance with DIN 43650 form A Enclosure, IEC 529 IP00 with DIN spade connector, IP65 with cable plug Plug type Cable plug (042N0156) Dimensions and weight L without cable plug L with cable plug L with protective cap Weight [mm] [mm] [mm] [kg] 48 72 64 0.10 Accessories: Cable plug Type, Form A GDM 2011 (grey) cable plug according to DIN 43650-A PG11 042N0156 IC.PD.100.W7.02 8

Data sheet Indirect servo-operated 2/2-way solenoid valves, Type EV220W 10 - EV220W 50 Function, NC 1. Coil 2. Armature spring 3. Armature 4. Pilot orifice 5. Diaphragm 6. Equalizing orifice 7. Main orifice Function, NO Coil voltage disconnected When voltage is disconnected, the armature spring (2) presses the armature (3) down against the pilot orifice (4). Pressure builds up over the diaphragm (5) via the equalizing orifice (6). The diaphragm closes the main orifice (7) as soon as the pressure over the diaphragm equals the inlet pressure. The valve stays closed for as long as voltage remains disconnected. Coil voltage connected (open) When voltage is applied to the coil (1), the pilot orifice (4) is opened. Since the pilot orifice is larger than the equalizing orifice (6), pressure over the diaphragm (5) falls and the diaphragm is lifted clear of the main orifice (7). The valve stays open for as long as the required minimum differential pressure is present and voltage is applied to the coil. In principle the function involves the opposite valve positions to those above for applied and disconnected voltage respectively. 1. Coil 2. Armature spring 3. Armature 4. Pilot orifice 5. Diaphragm 6. Equalizing orifice 7. Main orifice IC.PD.100.W7.02 9

Capacity diagram Example for water: Capacity for EV220W at a differential pressure of 3 bar: Approx. 7 m 3 h EV220W 10 EV220W 14 EV220W 18 - EV220W 22 EV220W 32 EV220W 40 EV220W 50 m 3 /h IC.PD.100.W7.02 10