with Timer Override Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Similar documents
Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

PowerTrak. Curtain/Vent Actuator. Hired Hand Manufacturing, Inc Co Rd 68 PO Box 99 Bremen, Alabama 35033

Farm Hand Vent Master 24

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

INSTALLATION INSTRUCTIONS

Pivot Point Lite Wiring Manual

Installation and Construction Notes for EVSE4

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

A WORD ABOUT PROPER GROUNDING

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

INSTALLATION/OPERATING INSTRUCTIONS MCP

NEC Codes if more current shall supercede this manual

SN1010 NATURAL VENTILATION CONTROLLER SET POINT

BSR Magic Box Digital ignition control for 4, 6, or 8 cylinder engines

Convertible Relay Replacement System. Convertible Relay Replacement Systems A Reliable replacement for the original Plugs and Relays 8/20/2008

Combined Ventilation Controller RVWS-T-113HA

Auxiliary Status Switch Kit

Combined Ventilation Controller RVWS-T-224HA

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Dodge Cummins Positive Air Shutoff

8300 Series Installation Guidelines

ELITE 600

Service Manual Model S800 Smart Stand

R & D SPECIALTIES ROTROL I USER'S MANUAL

Temperature Controller OVATION 214 User's Guide

Field Commander Lite Wiring Manual

Service Manual Model S400 and S500 Smart Stand

Installing the gate post bracket with the cardboard arm template

Convertible Relay Replacement System

MODEL NO. UTL-60-7

E1.x Instruction Manual Supplement for Model 32 and 40

For installation instructions refer to the mounting and dimensions details and the terminal layout drawings on page 5 of this manual.

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Mega 475

INSTALLATION INSTRUCTIONS

MANUAL TRAVEL CLAMPS WITH HWH ROOM EXTENSIONS

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

ANZI Transfer Switch and Generator Wiring Installation Addendum

SMT-AZC INSTALLATION / OPERATION MANUAL

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

INSTALLATION/OPERATING INSTRUCTIONS TSC

Electronic Refrigerator Diagnostics

AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

Advanced EasyStart Troubleshooting

Poly Electric Drinkers

Service Manual Model L1000 Smart Lift

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Drop Feeder Control. Part Number Introduction. Setting the Control. Time Clock operation. Manual Operation

Zonestar Installation Manual

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Poly Electric and Non-Electric Drinkers (Models PCPE, PCPI, PCSE, PCSI, PFL-C, PFL-H, PCHI, PCHE, XCPE)

LED Hydro Grow Light. Instruction Manual MODEL: 300TTL-G 300TTL-GB 600TTL-G 600TTL-GB

Embedded Rack Slide-out System

GLM SERIES CONTROL Users Manual Rev:

ELITE 625 With Dial Display Control

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

For a proper and safe Installation Read the entire manual before Installation

Premier K9. Premier K9 assumes no liability for the correct application or installation of this circuitry.

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

User Manual. 1. Introduction

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

Parkit360 Transformer

Installing the gate post bracket with the cardboard arm template

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

E2000 SERIES ELECTRIC BAKE/ROAST DECK OVENS

2 CHANNEL MULTI-PURPOSE RECEIVER

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

Structures Testing. Instrument. User Guide V0217

Vehicle Security System

Model 277EC ENGINE IDLE LIMITER

BURGLAR ALARM KIT MODEL K-23. Assembly and Instruction Manual ELENCO

Spectra C3 Light Bar Installation Instructions

Programmable 8 Channel Injector Driver Module

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature.

REPLACEMENT PARTS LIST

Model 6275RC 50% Duty Cycle Compressor

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

Horizon Troubleshooting Flowchart

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

5300 Series Installation Guidelines

Model Rumbler 2 Low Frequency Siren Amplifier Installation and Operation Instructions

Installation, Operation and Maintenance Manual

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size

CT325 TEMPERATURE CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

Electro-Mechanical Swing Operator. Table of Contents

Two Channel Remote Shutdown Device

reflect energy: the ability to do work

( Versions Available)

Troubleshooting Checklist

ARMOR UP FOR YOUR NEXT ADVENTURE! 6530 Federal Blvd. Lemon Grove, CA (844) , ext

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual

Operation and Installation Manual

Transcription:

PC-DB Curtain Controller with Timer Override Hired Hand, Inc. 17 Co Rd 68 PO Box 99 Bremen, AL 0 801-108 Rev 1/99 Owner's anual PC-DB Curtain Controller

PC-DB Curtain Controller with Timer Override 1. WARNINGS...1. PHYSICAL DESCRIPTION.... USE OF EQUIPENT.... INSTALLATION.... SET-UP INSTRUCTIONS....1. CURTAIN TIER....1.1. Description....1.. Setting machine runtime..... OVERRIDE TIER.....1. Description... 6. OPERATION... 6.1. ANUAL CONTROL... 6.. AUTOATIC CONTROL... 6.. OVERRIDE... 6.. OPTIONAL OVERRIDE... 7. WIRING DIAGRA... 1. Warnings Warning! When this controller is used in a life support heating and ventilation system where failure could result in loss or injury, the user should provide adequate back-up, or accept the risk of such loss or injury! Warning! Wiring and connections must comply with all national and local electrical codes. Installation by qualified electrician required! Warning! Electrical shock may occur if the enclosure is opened with power connected to the unit. Before opening the enclosure, make sure that all power sources to controller are disconnected! 801-108 PC-DB-with Timer Override 1

. Physical Description V Override Relay Close Relay Curtain Timer Terminal Connections Open Relay The picture on the left above is the front of the controller. The picture on the right is a picture of the internals of the controller showing major components.. Use of Equipment This Power Curtain Controller is built for use in agricultural enclosures for temperature control. The machine will operate one PowerTrak machine in response to temperature changes. Additionally, the controller has a timer override that will completely override the thermostat and close the curtain at selected times, and hold the curtain closed until the selected time.. Installation 1. ount unit to wall near power supply.. Connect nine conductor wire from PowerTrak to the terminals shown on the wiring diagram in the back of this manual.. Connect thermostat to terminals as shown in the wiring diagram in the back of this manual.. (Optional) Connect optional override to the terminals shown on the wiring diagram in the back of this manual.. Close door and apply power to the machine.. Set-up Instructions.1. Curtain Timer.1.1. Description The curtain timer is a five minute electro-mechanical timer. Look at the picture above to get an idea of the different parts discussed in this section. This timer is very simply designed. A constant speed motor drives the two wheels at the same speed in the same direction. There are tabs attached to the wheels that will actuate switches on the timer body as they pass. 801-108 PC-DB-with Timer Override

The wheel on the right is the open wheel. As this wheel rotates, the tabs attached to this wheel will control the opening of the machine. The wheel on the left is the close wheel. As this wheel rotates, the tabs attached to this wheel will control the closing of the machine..1.. Setting machine runtime Tabs may be attached to the timer wheels on either side. A tab attached to the right hand side of either wheel is the ON tab. As this tab strikes the switch, it will provide a path for current to operate the relay that will open or close the machine. However, a tab attached to the left hand side of either wheel is the OFF tab. As this tab moves past the switch, it will shut off the path for current that was opened by the ON tab. It is important that when adjusting the tab positions, that you keep the tabs on the open wheel at 180º to the tabs on the close wheel. This is to prevent the curtain from rapidly switching directions. This is important especially when using a curtain machine other than one designed by Hired-Hand. You may place two or three sets of tabs on the wheels if you would like. This will allow you to run the machine in shorter time increments, but more often. To increase the factory set runtime, place the off tab farther along the same wheel. Remember that a whole revolution of the wheel is five minutes. Shortening the span between the tabs decreases the runtime, and widening the gap between tabs increases the runtime... Override Timer..1. Description This controller has a timer operated override that will close the curtains at any time you select on the timer. The picture on the left shows the timer that is installed on the left hand side of the controller face. The timer is a hour timer that has switches (trippers) that represent fifteen minute intervals. At any time you want the curtains or vents to be closed, you slide the tripper that corresponds to the time on the dial to the outer position. When the timer reaches that position, the controller will close the curtains and override the controller. Any time the switches are in the inner position (automatic position) the controller will work in the normal fashion. The timer has a manual override switch that can be used to set the timer as automatic, permanently on, or permanently off. This switch is pointed out in the picture above. 801-108 PC-DB-with Timer Override

The override also has a three position switch called the manual override switch. This switch allows you to manually override the controller, or to disable the override function. The switch positions are explained in the Timer Override Controls chart below: Timer Override Controls Off position with trippers pushed in (Trippers pushed out will close contacts & and turn load on). -Way anual Switch = Permanent ON = Automatic = Permanent OFF ON ON OFF OFF 6. Operation 6.1. anual Control When the Automatic/anual switch is in anual, the controller will open and close the curtains or vents whenever the bottom switch is in its open or close position. The center position of the switch is the off position. 6.. Automatic Control When the controller is in automatic, the controller will move the curtains or vents as needed by the temperature set on the thermostat. Under normal conditions, the controller will move the machine once every five minutes. The machine will open if temperature is higher than the thermostat setpoint, and the machine will close if temperature is lower than the thermostat setpoint. To adjust the amount of time the machine runs each five minutes: 1. Turn off power to the control box.. Find the timer switch.. ove the two tabs farther apart to increase the time the curtain machine moves, and move the tabs closer together to shorten the time the machine moves. 801-108 PC-DB-with Timer Override

. Close control box lid, and re-apply power. The DB in the controller name refers to the Dead-Band operation of the controller. To use the dead-band feature you must have a two stage thermostat. This thermostat is available at your Hired-Hand dealer. The dead-band is a three to four degree temperature band which satisfies the controller. Any time the temperature is inside this band, the controller will not close or open the curtain machine automatically. However, if temperature should exceed the dead-band, the controller will operate to return temperature to the band. To place the controller in automatic operation, select Automatic with the top toggle switch on the control box. 6.. Override Remember that when the timer is on, the curtain will be closed. And whenever the timer is off the curtain will run as the controller tells it to. This timer is only used to override the controller, not to supplement it s operation. 6.. Optional Override If you have a weather station, or some other system you want to automatically close the curtains, you may do so by hooking to the machine as an optional override. This connection is normally open, and will close whenever a Volt source is applied. The connections are shown along the terminal strip on the wiring diagram below. 7. Wiring Diagram Below is a wiring diagram of the internals of the controller. All connections are shown, as well as thermostat hookup. WITHOUT DEADBAND, HOOK-UP OF OPTIONAL A-19 SINGLE STAGE THEROSTAT NOTE : 1. WIRES FRO TIER OTOR CONNECT TO POSITIONS 1 & ON TERINAL BLOCK. RED BLACK GREEN WHITE 10 11 1 1 OPTIONAL TO REVERSE OPENING AND CLOSING DIRECTIONS SWITCH TOP WIRES ON TERINALS AS SHOWN 6 7 8 801-108 PC-DB-with Timer Override

8 CONNECTOR WIRE FRO POWER UNIT WHITE BROWN RED BLUE ORANGE BLACK GREEN YELLOW 1 6 7 8 9 10 11 1 1 1 1 16 GREEN BLACK RED WHITE } CO ON Green Black White To No. 1 Pos. on Terminal Block From Black Wire On Cordset 10 Volts To Fuse A-8 Two Stage Thermostat with DEADBAND V Source Overrride (Optional) 801-108 PC-DB-with Timer Override 6