IQL Helios Area-/Streetlight. User Manual

Similar documents
ILED Dorado. User Manual

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius CIRCLE-H Helideck Lighting System

Solenoid Operator 0516 / 1216

Zone 1 Linear Range - Installation Guide

Operating Instructions

Solenoid Operator 0513 / 1213

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Multi-Mover Charger for model L25

Technical Documentation

Operating Instructions

Floodlight Range Installation Guide

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

EX-REPAIR AND MAINTENANCE RECEPTACLES

OPW Fluid Transfer Group Europe BV

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

DIAMOND POINT VIBRATING PROBES

SITRANS P measuring instruments for pressure

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

INSTRUCTION MANUAL (ATEX / IECEx)

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Wolflite XT Rechargeable LED Handlamp

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Operating Instructions

7 Lighting Technology

Operating Instructions

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

INSTRUCTION MANUAL (ATEX / IECEx)

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

AEROSTAT HP-N-Ex Ionising Air Blower

Swing Piston Compressors and Vacuum Pumps

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mass Sine 24/10000 Mass Sine 24/15000

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Operating Instructions

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Operating instructions Solenoid interlock EX-AZM About this document. Content

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Uninterruptible power supply Supply MEg101.4

Capanivo Series CN 4000

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Mini temperature switch Stainless steel switch enclosure Model TXS

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Control and Terminal Box Type A21-**-*****

Installation and Operating Instructions Magnetic Vibrator MR 1

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

Operating instructions

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

PHOENIX CONTACT - 01/2008

Easy and safe installation

Thermocouple with spring-loaded tip Model TC55

DC Master 24/ A

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Floodlight LED Series 6525

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

EStrong-series Emergency Stop

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

Emergency lighting units EM LED Light Engines

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

PRODUCT SPECIFICATION. Stack Lights. Series.

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Compact temperature switch Model TCS

International approvals.

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Instruction Manual. Ex-Time 40 / 50

Type 2000 Transducer Product Instructions

Phoenix Inverter

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Heavy Duty Series (HDS) Installation and user guide

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Compact Sheet-Steel Light Fittings Series 6114/1

Unused flameproof threads for cable glands have to be closed with certified plugs.

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

A good connection. International approvals.

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Transcription:

Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation... 7 6.1 Preparation... 7 6.2 Assembly... 7 6.3 Connections...12 7. Use... 13 7.1 Commissioning...13 7.2 Insulation test...13 8. Maintenance... 13 9. Recycling... 13 10. Contact details... 13 11. EC Declaration of Conformity... 14 Copyright IMT B.V. All rights reserved. No part of this may be copied, redistributed, published or changed without the prior written permission of IMT B.V. 2 Version 4.6 201302

1. Safety In order to use the product safely and optimise the life of the product, the following instructions must be observed. Only qualified personnel may install the product. Work in accordance with locally applicable safety standards and regulations. Ensure there is a reliable connection to the earthing system. Do not clean the light fitting with a high pressure steam or water jet, to avoid damage not covered by warranty. 2. Warranty 2.1 General The guarantee on the IQL Helios fittings is only applicable when the light fitting is used within the operational limits. Operational limits are: The minimum and maximum ambient temperature for the IQL Helios fittings are -20 C to +40 C. The light fitting must be installed by a qualified person and in compliance with the installation instructions. Damage caused by incorrect installation, accidents or external influences such as lighting strike and harmonic distortion not in accordance with EN 50055 are not covered by the guarantee. The lighting level of the light fitting depends on the temperature and is therefore not covered by the guarantee. If an IQL Helios fitting fails within the warranty period, IMT B.V. will supply a new fitting with a comparable specification free of charge. Before the guarantee can be confirmed, a defective light fitting must be sent to IMT B.V. at the user s expense for inspection. After this inspection the user will be informed of the result(s). See invoice for individual guarantee agreements. 2.2 Life span Switching the light fitting with a semiconductor photoelectric cell or a semiconductor relay has no known effect on the life span of the light fitting. It is expected that more than 70% of the original illumination power will be retained after 80,000 operating hours. 3 Version 4.6 201302

3. Type plate 3.1 Standard model The standard model light fitting has a type plate attached: TYPE PLATE This contains the following information: 1. Type : Low temperature range IQL55-LT IQL85-LT : Normal temperature range IQL55 IQL85 2. Ambient temp. : Low temperature range -40 C up to 40 C : Normal temperature range -20 C up to 40 C 3. Serial number 4. Year of Manufacture 5. Frequency : AC 50/60 : DC none 6. Voltage : 200-277Vac/dc or 100-120Vac/dc 7. Current : 100-120 Vac/dc 200-277 Vac/dc : 55W 460mA 260mA : 85W 730mA 400mA : 165W 1420mA 740mA 3.2 Explosion proof model The explosion proof model light fitting has a type plate attached: TYPE PLATE This contains the following information: 4 Version 4.6 201302

1. Type : Low temperature range IQL55-LT IQL85-LT : Normal temperature range IQL55 IQL85 2. Ambient temp. : Low temperature range -40 C up to 40 C : Normal temperature range -20 C up to 40 C 3. Serial number 4. Year of Manufacture 5. Frequency : AC 50/60 : DC none 6. Voltage : 200-277Vac/dc or 100-120Vac/dc 7. Current : 100-120 Vac/dc 200-277 Vac/dc : 55W 460mA 260mA : 85W 730mA 400mA :165W 1420mA 740mA 8. Marking : IQL 55 and IQL 85 : Ex II 3 GD EEx na II T4 T135 C IP66 IQL165W : Ex II 3 GD EEx na II T3 T160 C IP66 4. Product Description All IQL Helios light fittings have been designed for use in demanding conditions. The characteristics of the IQL Helios fittings are: Maximum of 10 year guarantee on correct operation 1 100,000 hours maintenance-free operation expected 2 sealed for life vibration proof based on the principle of induction explosion-safe model ATEX category 3 suitable for use in Zone 2 & 22 1 For the Helios IQL 165 a different maximum guarantee period of 6 years applies. See invoice for individual guarantee agreements. 2 For the 165W version 60.000 hrs maintenance-free operation expected 5 Version 4.6 201302

5. Specifications 5.1 General Housing : Copper free aluminium Lens : Toughened glass Colour recognition : Ra>80 Ingress protection : IP66 Burning position : Universal (Re)ignition : Instant Power factor : >0,92 Connection IP66 : Standard-3 pole Terminal Block Connection EX Zone2 : Standard-12m flying lead Type RMcL H07RN-F 3x2.5mm² Options: The following options are available for the IQL Helios light fittings: Lamp Colour : Warm White (colour 827), Cool White (colour 840), Clear Sky Wattage : 55 watt, 85 watt and 165 watt 5.2 Dimensions 55/85W 165W 6 Version 4.6 201302

6. Installation 6.1 Preparation 1. Check that the light fitting will be installed in an environment that matches the ambient temperatures, gas group and temperature class (for Zone 2 and 22). This data is shown on the light fitting type plate. WARNING The installation of the light fitting in an environment that does not match the specified conditions can result in a dangerous situation. WARNING The installation of the light fitting in an environment that does not match the specified ambient temperatures can have a strong negative effect on the life span of the light fitting. 2. Choose the correct type of protection for the light fitting. The protection device needs to be a fuse or a circuit breaker of at least 4 ka with a C characteristic. 3. Determine the number of light fittings that can be installed in each group. Consult the following table for this. 55 W 85 W 165 W Installation protection 100-120 200-277 100-120 200-277 200-277 B Type, 10 A 15 20 15 20 10 C type, 10 A 15 20 15 20 10 B Type, 16 A 22 30 22 30 16 C type, 16 A 26 35 26 35 16 55 W 85 W 165 W 100-120 200-277 100-120 200-277 200-277 Inrush currents 16 12 16 12 24 Peak duration 170 μs 170 μs 170 μs 170 μs 140 μs When using 30 ma earth leakage switches, provision must be made for a maximum of 30 light fittings on one switch. 6.2 Assembly Make sure there is a reliable connection to the earthing system. WARNING The installation of the light fitting in an environment that does not match the specified conditions can result in a dangerous situation. WARNING The installation of the light fitting in an environment that does not match the specified ambient temperatures can have a strong negative effect on the life span of the light fitting. WARNING For Zone 2 and Zone 22 installation: the installation must be carried out in accordance with (NEN-EN) IEC 60079-14. 7 Version 4.6 201302

1. Take the light fitting out of the packaging. 2. Inspect the light fitting for mechanical damage. 3. Unscrew the metal screw to open the light fitting. 4. Check if the bag that comes with the product contains the following fixing materials: 2 plastic covers 2 long M8 socket-head bolts. 2 short M8 bolts (self drilling) 1 mast clamp. 1 strap clamp 5. Remove the plastic caps from the inserts. For Horizontal Mounting (for vertical mounting see 13 onwards) 6. Place the corresponding plastic cover over the mounting hole that will not be used. 8 Version 4.6 201302

7. Slide the long M8 socket-head bolts from underneath into the light fitting. 8. Fasten the mast clamp by turning the socket-head bolts a few times into the clamp. 9. Place the light fitting on the mast and tighten the socket-head bolts until the light fitting is completely fastened to the mast. 9 Version 4.6 201302

10. Connect the incoming cable to the connecting block. 11. Fasten the incoming cable by clamping it tight under the strain relief. 12. Close the light fitting. Fasten the metal screw securely to lock the light fitting. For Vertical Mounting 13. Place the corresponding plastic cover over the mounting hole that will not be used. 10 Version 4.6 201302

14. Slide the long M8 socket-head bolts from underneath into the light fitting. 15. Fasten the mast clamp by turning the socket-head bolts a few times into the clamp. 16. Place the light fitting on the mast and tighten the socket-head bolts until the light fitting is completely fastened to the mast. 11 Version 4.6 201302

17. Connect the incoming cable to the connecting block. 18. Fasten the incoming cable by clamping it tight under the strain relief. 19. Close the light fitting. Fasten the metal screw securely to lock the light fitting. 6.3 Connections In the light fitting there is a standard connecting block, suitable for a single phase supply. The following connection can be made: L-N : Connection for the power supply. In case of a flying lead instead of a standard connecting block, the neutral (code N - blue), the phase (code L brown) and earth (code PE, yellow-green) need to be connected. 12 Version 4.6 201302

7. Use 7.1 Commissioning The light fitting can be switched on immediately after installation. 7.2 Insulation test Installations in which IQL light fittings are installed can be checked with an insulation test. For this test, apply a maximum of 500 Vdc between earth and a phase or neutral connection. WARNING Never apply more than 500 Vdc between a phase and a neutral connection. During production, all light fittings have been subjected to a dielectric test (2100 Vdc for 60 seconds). In addition, the light fittings have also been subjected to an endurance test. 8. Maintenance The light fitting s critical components (the light compartment consisting of the reflector with glass and the sealed off electronics compartment) are sealed for life and cannot be opened. Consequently maintenance as laid down in the IEC 60079-17 standard is not applicable; a visual inspection for correct operation will suffice. WARNING Opening the light compartment or electronics compartment voids the guarantee. 9. Recycling For recycling the light fitting, agreements have been made with local bodies within the context of the WEEE directive. Contact your local partner (see the chapter Contact details ). The local partner will be responsible for further processing. 10. Contact details IMT B.V. Pascalweg 10a, 4104 BG Culemborg P.O. Box 88, 4100 AB Culemborg THE NETHERLANDS Phone : +31 (0)88 12 69 100 Fax : +31 (0)88 12 69 101 E-mail : sales@imt.eu For an up-to-date overview of all national and international contacts, visit our website: www.imt.eu. 13 Version 4.6 201302

11. EC Declaration of Conformity The undersigned, representing the company IMT B.V. Pascalweg 10a 4104 BG Culemborg The Netherlands Phone :+31 (0) 88-12 69 100 hereby declares that the product: IQL Helios marked with Ex II 3 GD EEx na II T4 T135 C IP66 or Ex II 3 GD EEx na II T3 T160 C IP66 complies with the terms of the EC directive(s) including all applicable supplements. 94/9/EC 2004/108/EC Equipment and protective systems intended for use in potentially explosive atmospheres Electromagnetic Compatibility and that all of the following standards and/or technically related specifications are met. Standard Issue Title EN 50021 1999 Electrical apparatus for potentially explosive atmospheres. Type of protection n. EN 50281-1-1 1998 Electrical apparatus for use in the presence of combustible dust part 1-1: Electrical apparatus protected by enclosures construction and testing. EN 61547 2001 Equipment for general lighting purposes. EMC immunity requirements EN 61000-3-2 2006 Limits for harmonic current emissions (equipment input current up to and including 16A per phase), EC type certificate number PHX04ATEX1001X issued by ph Xconsultancy 8 Ellingham Leas Maidstone, Kent UK Culemborg, 1-04-2011 IMT B.V. R.L.L.M.G. Mignot, Managing director 14 Version 4.6 201302

15 Version 4.6 201302

IMT B.V. Pascalweg 10a, 4104 BG Culemborg P.O. Box 88, 4100 AB Culemborg Tel: +31 (0)88 12 69 100, Fax +31 (0) 88 12 69 101 www.imt.eu, sales@imt.eu