Ohio State University Extension. Boom Sprayer Calibration, AEX Food, Agricultural and Biological Engineering

Similar documents
SECTION II - SPRAYER CALIBRATION

Calibrating. Pesticide. Application. Ground. Equipment

Calibration of Chemical Applicators Used in Vegetables1

CALIBRATION LEARNING OBJECTIVES

Boom Sprayer Calibration

Calibration of Herbicide Applicators 1

Sprayer. Agricultural. Calibration

Calibrating Chemical Application Equipment

Why calibrate? Calibrating your spray equipment

Citrus Herbicide Boom Sprayer Calibration 1

Calibrating Boom Sprayers

Application Equipment and Techniques 1

factsheet Field Sprayer Calibration Introduction Pre-Calibration Checklist Using a Calibration Bottle

Air- Blast Sprayer Calibration for Pecan Orchards

Fine Tuning a Sprayer with Ounce Calibration Method

U.^JIVERSITY OF LIBRARY. AT ll-i"^ '2 AT URBANA CHAMPAIGN AGRICULTUR'^

Equipment CHAPTER 21

Proper sprayer application depends on the combination of six basic properties. These are:

Fine Tuning a Sprayer with ''Ounce'' Calibration Method Robert Grisso, Mike Weaver, Kevin Bradley, Scott Hagood, and Henry Wilson*

SPRAYER NOZZLES: Selection and Calibration

Calibration of Airblast Sprayers 1

Calibration Worksheet

INSECTICIDE APPLICATION

When You Buy or Build a Field Sprayer

Choose your spray pressure. Measure the spray output (gallons per minute).

Calibration & Safety of Pesticide Application Equipment Seminar. Calibration Formulas Workbook

Tools Needed for Calibration

electronic copy of this publication. Calibrating is the first and most important step to product application

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

FACT SHEET. Lighting and Marking Recommendations for Buggies and Wagons AEX

User Guide Skid Sprayers

Optimizing and Calibrating Sprayers

APPLICATION EQUIPMENT

PESTICIDE APPLICATION TIPS AND TECHNOLOGIES. John W. Inman. P.E.

Calibration of Airblast Sprayers 1

Calibration of herbicide sprayers

Model: ATVTS-60-12V 60 Gallon Trailer Sprayer W/7 Nozzle Boom ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

2. AGRICULTURAL CROP SPRAYERS

Sprayer Equipment. Aerial Pesticide Applications. Ground-based Pesticide Applications. Airblast Sprayers. Hand Operated Sprayers.

Which Sprayer Had the Best Results?

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Part 8: Equipment: Selecting, Calibrating, Cleaning

Technical Information

MODEL NO. ATVBK NOZZLE BOOM ASSEMBLY FOR ATV MOUNTING ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Calibrating Turf Sprayers and Spreaders: Keys to Application Accuracy

A Home-Made. Sprayer. for Attachment to a. Tractor Power Take-Off ARTMENT OF AGRICULTURE c.3 PUBLICATION 1007 ISSUED FEBRUARY 1957

A G SP R A Y & F E RTILIZER EQ U IP M E N T. Pesticide drift reduction through parts selection and calibration.

How important is Calibrating your sprayer on a regular basis?

SPRAY NOZZLE TECHNOLOGY

Sprayer Calibration For. Citrus

Gandy Positive Displacement Metering System

MODEL: ATVBK-710 BEFORE RETURNING THIS PRODUCT FOR ANY REASON, PLEASE CALL

Application Calibration 101

Pesticide Application Technology 1

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

Spray Tip Guide HIGH QUALITY SPRAY TIPS FOR EVERY SPRAYING NEED. w w w. h y p r o p u m p s. c o m

Air-Assisted Electrostatic Sprayers for Field Crops. K Series. Electrostatic Spraying Systems, Inc.

MODEL NO. UTL-60-7

VisiFlo Hollow Cone Spray Tips

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

TKP3501 Agricultural Mechanization

SPRAY EQUIPMENT (NOZZLES, PUMPS, SYSTEMS)

VERIFYING THE ACCURACY OF LIQUID ADDITIVE METERING SYSTEMS

1. E9 Application quipment and Techniques

Pesticide Application Equipment

15/25 GALLON NEW DIRECTION TRAILER SPRAYER

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Plumbing Systems of Agricultural Sprayers

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

Owner's Manual. Model: ATVBK-3025 ( ) (Boomless Nozzle Kit for ATV Mounting) Technical Specifications. Assembly. General Information

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

30 GALLON TRAILER SPRAYER ASSEMBLY & OPERATION INSTRUCTIONS MANUAL TSC SKU#: VENDOR#: TS30G-CL

ASSEMBLY AND OPERATING INSTRUCTION MANUAL

LG-60-3PT-WP-309-BL-TSC

SCS 340 INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

T 0 H I G H W A Y P A V E M E N T S

Toro Sprayer Calibration Tool

How to. Calibrate Turf Sprayers NOTEWORTHY PROGRESS

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING 10 ATV BOOM KIT

Supplemental Manual for All PulsFOG Machines. Dramm pulsfog Manual Supplement 1/14

DUAL NO BOOM & CENTER DF NOZZLE

Owner s Manual Instructions for Assembly and Operation

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Cover Crop Seed and Small Grain Rate Chart

Nozzle selection for boom, band and shielded spraying

Don t Freeze the Engine

NOZZLES. Choosing drift-reducing. What nozzle should I use? That s as hard a question as What FS 919

MACHINERY COST ESTIMATES

MID-TECH MIDWEST TECHNOLOGIES, INC. TASC-6000, 6300, & 6600 Total Application Sprayer Control System User Guide PN Rev. # - 1 MID-TECH.

Supplemental Manual for TracFOG

TEEJET VARI-SPACING NOZZLES

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING 7 BOOM KIT

OWNER S MANUAL. Model: LG-25-BL-QR ( ) (25 Gallon ATV Dual Nozzle Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

NOZZLES. Selecting drift-reducing. What nozzle should I use? That s as hard a question as What tractor USDA. FS 919 Rev. 7/08

Transcription:

Page 1 of 7 Ohio State University Extension Food, Agricultural and Biological Engineering 590 Woody Hayes Dr., Columbus, Ohio 43210 Boom Sprayer Calibration AEX-520-92 H. Erdal Ozkan Professor and Extension Agricultural Engineer Food, Agricultural and Biological Engineering Department Calibrating a boom sprayer is not as difficult as it sounds. Although there are many methods to use, the method described here is simple and requires few calculations. It's based on spraying 1/128 of an acre per nozzle and collecting the spray that would be released during the time it takes to spray the area. Because there are 128 ounces of liquid in 1 gallon, this convenient relationship results in ounces of liquid caught from one nozzle being directly equal to the application rate in gallons per acre, or GPA. For example: If you catch an average of 15 ounces from a set of nozzles, the actual application rate of the sprayer is equal to 15 GPA. With this method, make sure that the time used to catch output from nozzles is the same as the time it takes to cover 1/128 acre. Table 1 shows the distance you must travel to cover 1/128 acre for different nozzle spacings and row spacings. For broadcast applications, use the nozzle spacing to determine the calibration distance. For band or directed applications, use the row spacing. Figure 1. Broadcast spraying.

Page 2 of 7 Table 1. Calibration distance for each nozzle to spray 1/128 acre. Nozzle/row spacing (in.) Travel distance (ft.) To calibrate your sprayer, you need a measuring tape, a watch capable of indicating seconds, and a measuring jar graduated in ounces. A pocket calculator also will be handy. Calibrating for Broadcast Application Follow these steps when calibrating boom sprayers for broadcast applications: 1. Fill the sprayer tank with water. Nozzle/row spacing (in.) 18 227 30 136 20 204 32 127 22 185 34 120 24 170 36 113 26 157 38 107 28 146 40 102 Travel distance (ft.) 2. Run the sprayer, inspect it for leaks, and make sure all vital parts function properly. 3. Measure the distance in inches between the nozzles. Then measure an appropriate distance in the field based on this nozzle spacing, as shown in Table 1. 4. Drive through the measured distance in the field at your normal spraying speed, and record the travel time in seconds. Repeat this procedure and average the two measurements. 5. With the sprayer parked, run the sprayer at the same pressure level and catch the output from each nozzle in a measuring jar for the travel time required in Step 4. 6. Calculate the average nozzle output by adding the individual outputs and then dividing by the number of nozzles tested. If an individual sample collected is more than 10 percent higher or lower than the average nozzle output rate, check for clogs and clean the tip, or replace the nozzle. 7. Repeat steps 5 and 6 until the variation in discharge rate for all nozzles is within 10 percent of the average. 8. Then, the final average output in ounces is equal to the application rate in gallons per acre: Average output (ounces) = Application rate (GPA). 9. Compare the actual application rate with the recommended or intended rate. If the actual rate is more than 5 percent higher or lower than the recommended or intended rate, you must make adjustments. 10. You can start the adjustments by changing the pressure. Lowering the spray pressure will reduce the spray delivered; higher pressure means more spray is delivered. Don't vary from the pressure range recommended for the nozzles that you use. (Look to "Useful Formulas" on the back page to determine the new pressure rate.) 11. You also can correct the application error by changing the actual travel speed. Slower speeds mean more

Page 3 of 7 spray is delivered; faster speeds mean less spray is delivered. (Look to "Useful Formulas" on the back page to determine the new pressure rate.) 12. If these changes don't bring the application rate to the desired rate, then you may have to select a new set of nozzles with smaller or larger orifices. 13. Recalibrate the sprayer (repeat steps 5 through 12) after any adjustment. Calibrating for Band Spraying Pesticides sometimes are applied in bands centered on the crop row (Figure 2). The application rate on the treated band must be the same as the broadcast rate for band application to be effective. But the total amount of pesticide used on a field is less, because only a portion of it is treated with chemicals. Figure 2. Band spraying. Calibrating a sprayer for banding applications is similar to the procedure outlined for broadcast sprayers. The only difference is to choose the travel distance from Table 1 based on row spacing, not nozzle spacing. Drive the distance shown in the table at your spraying speed and catch the output from each nozzle for the length of time it takes to travel the indicated distance. The average nozzle output again is directly equal to the application rate in gallons per acre. This application rate is less than the broadcast rate, because only a portion of the field is treated with chemicals. For example: If the broadcast rate recommended is 15 GPA and you're spraying 10-inch bands on 30-inch rows, you will need only 5 GPA, one-third of the broadcast rate. Therefore, at the end of your calibration, the average number of ounces caught from all the nozzles should equal 5 ounces, which represents an application rate of 5 GPA. At this rate you will treat bands at the recommended 15 GPA rate but the entire field at 5 GPA. Herbicide recommendations are usually given on a broadcast basis. Therefore, convert the recommended broadcast rate to the band rate before comparing it with the measured rate to determine the application error. To convert a broadcast application rate to a band rate, use this formula: Band rate = Band Width (in)/row Spacing (in) X Broadcast rate Then, compare this converted band rate to the measured rate. Make some adjustments and recalibrate the sprayer if the difference between the two rates is greater than 5 percent of the recommended rate. Example Recommended broadcast rate: 15 GPA Rate measured with calibration: 6 GPA Row spacing: 30 inches

Page 4 of 7 Band width: 10 inches Determine the sprayer application error: First, convert the recommended broadcast rate of 15 GPA to the band rate: 10-in. band width/30-in row spacing X 15 GPA = 5 GPA Application error = 6 GPA - 5 GPA = 1 GPA (off by 20%) Because the application error is more than 5 percent of the recommended rate, adjustments must be made and the sprayer must be recalibrated. Calibrating for Directed Spraying Calibrating a row crop sprayer with two or three nozzles per row (Figure 3) is similar to calibrating a band sprayer. With broadcast or band applications, GPA is equal to the output from one nozzle. When more than one nozzle is used per row, the combined amount collected from all nozzles directed at one row is equal to the GPA. Again, this application rate is not the same as the broadcast rate. You must convert the recommended broadcast rate to the band rate before comparing it with the actual rate you obtained with calibration. Figure 3. Directed spraying. Example You want to spray a 30-inch row using three nozzles per row. The steps: 1. Select a travel distance from Table 1 based on row spacing. The distance to travel for a 30 inch row is 136 feet. 2. Drive 136 feet and measure the time in seconds. 3. If it took 15 seconds, catch the output from each of the three nozzles for 15 seconds. If each tip delivers 5 ounces, the total ounces collected per row is 15 ounces. This represents the sprayer application rate of 15 GPA. (5 ounces/nozzle X three nozzle/row = 15 ounces/row). 4. Repeat Step 3 for each set of nozzles on the boom to make sure the application rate is uniform across the boom. Adding the Chemical to the Tank

Page 5 of 7 You can spend hours in the field to achieve the accuracy desired from your sprayer through proper calibration, but it won't do any good if you don't know how much chemical to put in the tank. A survey conducted by agricultural engineers at the University of Nebraska revealed that of the applicators surveyed, 38 percent failed to add the correct amount of chemical to the tank. The amount of chemical needed per tankful depends on the recommended rate and the number of acres you can treat per tank of spray. To find the acres treated per tank, divide the tank capacity by the GPA application rate. To find the amount of pesticide needed per tank, multiply the number of acres treated by the amount of actual chemical to be applied per acre. Example 1 (broadcast application) A sprayer has a 300 gallon tank, and it has been calibrated to apply 15 gallons per acre. The pesticide label recommends 2 pints of commercial product per acre for broadcast application. Determine the quantity of pesticide to add to the tank: First, find the acres each tank will spray: 300 gal. per tank/15 gal. per A. = 20 A./tank Next, calculate the number of pints to be added to the tank: 20 A./tank X 2 pts./a. = 40 pts./tank The final mix consists of 40 pints (5 gallons) of pesticide formulation and 295 gallons of water per 300 gallons of tankful. NOTE: If the tank is not completely empty when refilling, use the amount of water required to refill the tank, not the capacity of the tank itself when determining acres treated per tank. For example: If you have a 300 gallon tank but you have 75 gallons of spray left in it when you refill, you will use 225 gallons in your calculations instead of the total tank capacity. 225 gal. refill/15 gal./a. = 15 A./refill 15 A./refill x 2 pts/a. = 30 pts./refill You must add 30 pints of chemical to the tank. Sometimes, chemical manufacturers give recommended rates in terms of active ingredient (A.I.) to be used per acre rather than the amount of total product per acre. In these cases, calculate the amount of material to be applied as shown in examples 2 and 3 for dry chemicals and liquid chemicals, respectively. Example 2 The application rate of the chemical is 2 pounds A.I. applied per acre. The material to be used is a wettable powder containing 50 percent A.I. Determine the quantity of chemical to add to the tank: Lbs. of material per A. = 2 lbs X 100/50 = 4 lbs./a. 4 lbs/a. x 20 A./tank = 80 lbs./tank Example 3

Page 6 of 7 The chemical you are using is liquid. The recommendation calls for 1 pound A.I. per acre. You have purchased a formulation that contains 4 pounds A.I. per gallon. Determine the amount of product needed per acre. Gal.of product needed per A.= 1 lb.a.i./a. /4 lb.a.i.gal = 0.25gal./A. Next, calculate the amount of chemical to add to each tankful: 0.25 gal./a. X 20 A./tank = 5 gal./tank Example 4 (Band Spraying) You want to apply a herbicide on a 12-inch band on rows spaced 36 inches apart. The herbicide label recommends 3 pounds of material per acre on a broadcast basis. The sprayer has a 300 gallon tank, and the application rate measured with the calibration method explained previously for band application is 5 GPA. Determine the amount of chemical needed per tank: First, determine how much chemical will be used when applied on 12-inch bands. 12-in. band/36-in row X 3 lbs./a. = 1 lb./a. The rest of the procedure to determine the chemical required per tank is the same as explained earlier for broadcast applications. 300 gal. per tank/ 5 gal. per tank = 60 A./tank 60 A./tank X 1 lb./a. = 60 lbs./tank Thus, you will need to add 60 pounds of chemical product to the 300 gallon tank. Mixing Chemicals Mixing the pesticide thoroughly and carefully is an important step in good sprayer operation. Incomplete mixing results in varied application rates - too heavy at times, too low otherwise. Some chemicals, when mixed improperly with others, form a thick, mayonnaise-like mixture that will not spray properly and is difficult to clean out of the sprayer. Always read the label for proper mixing sequence and test the compatibility of chemicals in a small container before mixing. Generally, when preparing the spray mixture, fill the tank more than half full of water and pour in the correct amount of chemical while the pump is running. Then, finish filling the tank. When using wettable powders, make a slurry in a separate container and then add the slurry to the tank to ensure good mixing. Other Considerations Here are some other considerations for calibrating your sprayer: Getting the right amount of chemicals on the ground is not enough to achieve effective pest control. How the chemical is deposited on the spray target is as important as the amount deposited. Make sure that all nozzle tips are properly aligned. Some nozzles require overlapping adjacent spray patterns. Check the nozzle catalog to determine the overlap required for a given type of nozzle. A common cause of non-uniform coverage is clogged nozzles. Watch the nozzles periodically while spraying to detect clogging. Always carry extra nozzles in your tool box, and replace bad nozzles with

Page 7 of 7 good ones immediately. In most cases, the pressure gauges on sprayers do not represent the actual pressure at the nozzle tip. Therefore, check the pressure at the nozzle tip when calibrating your sprayer. Safety is extremely important when working with chemicals. Always wear gloves and protective clothing when handling chemicals and calibrating sprayers. For safety reasons, use water instead of actual chemical mixtures when calibrating. However, some carriers, such as liquid fertilizers, are much denser than water and may cause the nozzle flow rate to vary from the rate obtained with water. In this case, determine the average nozzle output using the actual chemical mix in the field, away from the farmstead. Useful Formulas To determine the actual travel speed in the field: Distance (feet)/ Travel (seconds) X 0.68 = Travel speed (mph) To determine the appropriate travel speed (MPH) for a desired application rate (GPA): a. GPA 2 X MPH 2 = GPA 1 X MPH 1 b. MPH 2 = GPA 1 X MPH 1 / GPA 2 To determine the appropriate pressure (PSI) for a desired application rate (GPA): a. GPA 2 /GPA 1 = (sq.rt. PSI 2 )/sq.rt.psi 1 b. PSI 2 = PSI 1 X (GPA 2 /GPA 1 ) 2 GPA 2, GPA 1 : Desired and measured application rate, respectively (gal./a.). MPH 2, MPH 1 : Desired and measured travel speed, respectively (miles/hour). PSI 2, PSI 1 : Desired and measured spraying pressures, respectively (lb./in.2). Acknowledgment The author acknowledges the useful suggestions given by T.G. Carpenter and J.A. Gliem of the Department of Agricultural Engineering, Ohio State University. All educational programs conducted by Ohio State University Extension are available to clientele on a nondiscriminatory basis without regard to race, color, creed, religion, sexual orientation, national origin, gender, age, disability or Vietnam-era veteran status. Keith L. Smith, Associate Vice President for Ag. Adm. and Director, OSU Extension. TDD No. 800-589-8292 (Ohio only) or 614-292-1868 Ohioline Search Fact Sheets Bulletins