GP & GH Range. Pneumatic and Hydraulic Actuators for Quarter-Turn Valves. Established Leaders in Actuation Technology

GO Range. Gas-over-Oil Valve Actuators. Redefining Flow Control

HPG Range. Direct High-Pressure Gas Valve Actuators. Redefining Flow Control

GH RANGE HYDRAULIC SCOTCH YOKE ACTUATORS INSTALLATION AND MAINTENANCE MANUAL. Publication F131E Date of issue 04/08

GT Range. Rack & Pinion Actuators for Rotary Valve Control. Keeping the World Flowing

GP RANGE PNEUMATIC SCOTCH YOKE ACTUATORS INSTALLATION AND MAINTENANCE MANUAL

GT Range. Rack & Pinion Actuators for Rotary Valve Control. Keeping the World Flowing

GT Range. Rack & Pinion Actuators for Rotary Valve Control. Keeping the World Flowing

RCI200. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Established Leaders in Valve Actuation. Fluid Power Actuators and Control Systems

RC200. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Established Leaders in Valve Actuation. Fluid Power Actuators and Control Systems

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

IQTF Range. Keeping the World Flowing. Electric full output turn actuators for choke and control valve applications

Established Leaders in Valve Actuation CP RANGE COMPACT PNEUMATIC ACTUATORS INSTALLATION AND MAINTENANCE MANUAL. Publication F230E Date of issue 03/08

ROM and ROMpak Range. Quarter-turn Direct Drive Electric Actuators. Established Leaders in Actuation Technology

RCI200 Range. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Redefining Flow Control

RC200 Range. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Redefining Flow Control

CK Range. Keeping the World Flowing. Spare Parts Manual. Modular Design Electric Valve Actuators

GP & GH Range. Pneumatic and Hydraulic Actuators for Quarter-Turn Valves. Keeping the World Flowing

Position Transmitters. Instruction Manual. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

Roto Hammer Range. Chainwheels, Handwheels, Chains and Accessories. Keeping the World Flowing

IW Quarter-turn. Keeping the World Flowing. IW Quarter-turn Gear Series. Gearboxes

IQS and IQSL Range. Electrical Data Single-Phase Power Supplies. Keeping the World Flowing

GO RANGE GAS-OVER-OIL SCOTCH YOKE ACTUATORS INSTALLATION AND MAINTENANCE MANUAL. Established Leaders in Valve Actuation

Fluid Power Actuators and Control Systems. Established Leaders in Valve Actuation. GO Range. Gas-Over-Oil Actuators. Publication F301E Issue 11/05

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators

Skilmatic SI 3 3 Electric Fail-Safe Actuators

HPG Range. Direct High-Pressure Gas Actuators. Established Leaders in Valve Actuation. Fluid Power Actuators and Control Systems

G Type Range of Actuators

GTV Series High Pressure Control Valves

Q Range electric direct-drive quarter turn valve actuators. Instruction manual

Anodised aluminium construction for anti-corrosion and superior wear performance on internal surfaces

Poppet Valves Series. Keeping the World Flowing

P RANGE - SUPPLEMENTAL METRIC AND IMPERIAL TORQUE DATA. P - Pneumatic

ROM and ROMpak Range. Quarter-Turn Direct Drive Electric Actuators. Keeping the World Flowing

RC200 Range. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Keeping the World Flowing

RC200 Range. Compact Scotch-Yoke Actuators for Quarter-Turn Valves. Keeping the World Flowing

Established leaders in Actuation Technology. ROM & RBM Range 1/4 turn direct drive electric actuators. Publication E611E issue 10/02

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

NSF Series Pneumatic & Hydraulic Actuators. Installation & Operation Instruction Manual NUTORK CORPORATION

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

TUTORIAL QUESTIONS FOR THE INDUSTRIAL HYDRAULICS COURSE TEP 4205

Q Range. Watertight Single-Phase Electric Quarter-turn Actuators for part turn valves and dampers. Established Leaders in Valve Actuation

15,000kg HYDRAULIC BOTTLE JACK

K Range. High Torque Electric Valve Actuators. Redefining Flow Control

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

Rotork Australia. Product Ranges and Service Facilities. Redefining Flow Control

CHAPTER 29 HYDRAULICS Description Hydraulic Pump Hydraulic Reservoir Hydraulic Servos

TS1251 PRESSURE DISPENSER USER'S MANUAL

RIGHT HYDRAULIC PUMP. Right Hydraulic Pump Replacement. Right Hydraulic Pump Removal. 5. Remove the pump belt from around the pump pulleys (Fig. 002).

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

Poppet Valves Series

Contents. Directional Control Valve 3 Series CV 452. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves.

1394 Operating Instructions. Prepared by:- M.Davies Approved by:- Date: 12/03/14 REV NO:- 1 ECO: HPX1500 Hand Pump. Hand Pump 1500 Bar

INSTALLATION INSTRUCTIONS

Fluid Power Actuators and Control Systems. Established Leaders in Valve Actuation. R Range. Rack & Pinion Actuators. Publication F401iE Issue 02/07

AWT RANGE CONTROL AND MONITORING F ACILITIES. Publication E320E issue 10/02

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

LEFT HYDRAULIC PUMP. Left Hydraulic Pump Replacement. Left Hydraulic Pump Removal. 5. Remove the pump belt from around the pump pulleys (Fig. 002).

Environmental Qualification

Rotork Hiller Nuclear. Presented by:

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Type Series Booklet. Hydraulic Actuator

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

TIN KNOCKER TK H1652 Hydraulic Shear

SD3-60 AIRCRAFT MAINTENANCE MANUAL - DESCRIPTION & OPERATION

PRODUCT OVERVIEW. Our BDB (Bolted Body) and BW3 (Fully Welded Body) trunnion-mounted ball valves are designed and manufactured

2 Micro-Dot Manual Syringe Dispenser User Guide

Bettis CBB-Series Technical data sheet - Metric

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

Retrofit Actuator MS and MS Instructions R L

Valtek Flow Boosters

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

Actuator Control Manual

Fisher 3024C Diaphragm Actuator

Contents. AQ Instruction Manual

AWT Range. Watertight 3-phase Electric Valve Actuator. Redefining Flow Control

Hydraulic Pump Series VP1 Variable Displacement

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

Installation, Operation and Maintenance Manual

Rancher Hydraulic Chute Owner s Manual.

Bettis CBB-Series Technical data sheet - Imperial

TIMING BELT (1MZ FE Jan., 2003)

ABSOLUTE EQUIPMENT PTY LTD

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Fisher 657 Diaphragm Actuator Sizes and 87

ABSOLUTE EQUIPMENT PTY LTD

Installation guidelines. The system comprises of two basic circuits. These are:

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

MO Declutchable Manual Override Gearbox EL-O-Matic F-Series Actuators option

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

Transcription:

HP HYDRAULIC MANUAL OVERRIDE HPA / HPB / HPC / HP1 INSTALLATION AND OPERATION MANUAL

CONTENTS SECTION CONTENT PAGE 1 Introduction 2 Overview Installation Operation - Double Acting Operation - Spring Return Hydraulic Oil Specification Page 2 of Publication PUB01-00-00 Date of issue 0/1

INTRODUCTION 1.0 Introduction 1.1 The Rotork HP Hydraulic Override is a self-contained system for manual operation of GP, RP and P Range pneumatic actuators; and GH, RH and H Range hydraulic actuators. The unit consists of two main components, the hydraulic cylinder and the pump/reservoir assembly. It comes in four configurations for use with pneumatic or hydraulic actuators in double acting and spring return configurations. HYDRAULIC MANUAL OVERRIDE APPLICABILITY HYDRAULIC PNEUMATIC ACTUATOR TYPE DOUBLE-ACTING SPRING-RETURN DOUBLE-ACTING SPRING-RETURN HPA HPB HPC HP1 OV Note: HPB and HPC overrides utilise a single hydraulic cylinder for both local-manual and remote operation. HPA and HP1 overrides utilise a dedicated cylinder for manual operation. 2.0 Overview 2.1 Double-Acting The HP push/pull pump supplies high-pressure fluid to either side of the hydraulic cylinder depending on the position of the pump open/close selector valve. The valve actuation lever is moved from a disengaged centre position towards either the inboard or outboard end of the cylinder. This will pressurise the selected side to allow manual stroking of the actuator. 2.2 Spring-Return The HP push/pull pump supplies high-pressure fluid to the outboard side of the cylinder, moving the piston towards the actuator body and compressing the spring. This is accomplished through operation of the pump handle with the manual valve on the face of the pump closed. Page of Publication PUB01-00-00 Date of issue 0/1

INSTALLATION.0 Installation.1 The preferred position for operation of the hydraulic override is with the unit horizontal. In this position, the pump/reservoir will be mounted toward the upper side of the hydraulic cylinder. The unit may be mounted in the vertical axis if the pump/reservoir is positioned such that the pump is mounted upright and above the end of the hydraulic cylinder. This will require modification to the mounting bracket to allow for rotation of the pump/reservoir assembly. To facilitate any mounting position, the HP pump assembly is completely self-contained. The pump/reservoir assembly can be moved to any convenient mounting surface by re-routing tubing from the cylinder to the pump. When the pump/reservoir is located remote to the unit, it must be mounted so that the pump is above the highest point of the cylinder..2 Prior to shipment all manual valves will be in the open, remote operation ready position. These valves are represented by items and on the operational schematics included in section and. If the optional flow controls are included, they are supplied in the full open position to allow for uninhibited remote operation.. The HP hydraulic manual override system is self-purging and self-priming. To purge and prime the system, operate the unit in both directions for two complete cycles.. The proper oil level is approximately 2. cm (1 ) below the fill port/vent. The oil level should be checked with the unit in the horizontal position, with the piston at the farthest position in relation to the centre body. Our standard oil specification is listed in section. Many applications require alternative oils. If in doubt, consult Rotork Fluid Systems.. A vent is required on top of the reservoir for proper operation. A vented fill port plug is generally installed at the factory but in certain cases a closed plug is installed instead to prevent leakage during transport. If despatched with a closed plug, a vented plug with installation instructions is attached to the reservoir. The vent must be installed prior to operation.. Double-Acting Hydraulic Override Filling Procedure..1 Position the actuator so that the piston is contacting the end stop in the hydraulic override cylinder...2 Remove the fill port vented plug located in the left rear corner of the top of the hydraulic reservoir... Remove the plug located in the top of the hydraulic override cylinder bottom flange... Move the open/close selector valve towards the outboard side of the cylinder... Operate the pump handle slowly until oil exits the port in the top of the hydraulic override cylinder bottom flange. Be sure to maintain the oil level in reservoir so as not to drain the reservoir below intake tube... Reinstall the plug into bottom flange... Continue to operate the pump until the hydraulic piston reaches its closest position to the centre body... Remove the plug located in the top of the hydraulic override cylinder adapter flange...9 Move the open/close selector valve to the inboard side of the cylinder...10 Operate the pump handle slowly until oil exits the port in the top of the hydraulic override cylinder adapter flange...11 Reinstall the plug into adapter flange...12 Run the actuator in both directions for two complete cycles to completely purge the system of air...1 Verify oil level is correct and reinstall reservoir fill port vented plug.. Spring-Return Hydraulic Override Filling Procedure..1 Remove all air supply to the actuator so that the spring decompresses and the piston is contacting the end stop in the hydraulic override cylinder...2 Remove the fill port vented plug located in the rear left corner of the top of the hydraulic reservoir... Verify proper reservoir oil level... Close the pump On/Off selector valve and verify that the manual holding valve is open... Operate the pump to compress the spring to the point that the piston reaches its closest position to the centre body... Allow the cylinder to hold pressure for three to five minutes, to allow for any air to settle out of the oil... Slowly turn the On/Off selector valve counter-clockwise, allowing the spring to completely decompress... Repeat steps to...9 Reinstall reservoir fill port vented plug. Page of Publication PUB01-00-00 Date of issue 0/1

OPERATION Double-Acting.0 Double-Acting Hydraulic Override Operating Instructions.1 Manual Operation.1.1 The Hydraulic Bypass Valve () must be in the Closed position..1.1.1 For HPC overrides, the Local/Remote Selector Valve (10) must be in the Local position..1.2 Selection of operating direction is made by moving the Open/Close Selector Valve () toward the end of the cylinder to be pressurised..1. If the actuator is fitted with optional Flow Control Valves (11/12), the valve in the return line for the cylinder side being exhausted must be Open..1. Operating the Pump () will stroke the actuator..1. When manual operation is complete, return the Open/Close Selector to the Middle position and the Hydraulic Bypass Valve to the Open position..1..1 For HPC overrides, the Local/Remote Selector Valve (10) must be returned to the Remote position. 9 1.2 Power Operation.2.1 The Hydraulic Bypass Valve () must be in the Open position..2.1.1 For HPC overrides, the Local/Remote Selector Valve (10) must be in the Remote position..2.2 The Open/Close Selector Valve () must be in the Middle position..2. If the actuator is fitted with optional flow controls (11/12), they must be Open. The amount the flow controls are open will affect the remote operation speed. The flow controls can also be closed to lock the actuator in last position. CONNECTIONS TO ACTUATOR HP OVERRIDE FOR DOUBLE-ACTING ACTUATORS ITEM DESCRIPTION 1 Hydraulic Cylinder 2 Hydraulic Manual Override Assembly Open/Close Selector Valve Pressure Relief Valve (factory set) Hydraulic Reservoir Drain Plug HP Push/Pull Pump Hydraulic Bypass Valve 9 Fill Port / Vented Plug 10 Local / Remote Selector Valve (HPC only) 11 Adjustable Flow Control Valve (optional) 12 Adjustable Flow Control Valve (optional) 10 11 12 2 Page of Publication PUB01-00-00 Date of issue 0/1

1 OPERATION Spring-Return.0 Spring-Return Hydraulic Override Operating Instructions.1 Manual Operation.1.1 The Manual Holding Valve () must be in the Open position..1.1.1 For HPB overrides, the Local/Manual Remote Selector Valve (10) must be in the Local position..1.2 Close the On/Off Selector Valve () by turning in fully clockwise..1. Operating the Pump () will stroke the actuator and compress the spring..1. When the actuator has reached the desired position of travel, it can be locked in position by closing the Manual Holding Valve ()..1. To allow the spring to decompress, the Manual Holding Valve () must be moved to the Open position and the On/Off Selector Valve () backed out by turning anti-clockwise. 9.2 Power Operation.2.1 Power operation is accomplished with the On/Off selector valve () in Open, full anti-clockwise position and the Manual Holding Valve () in the Open position. HP OVERRIDE FOR SPRING-RETURN ACTUATORS CONNECTION TO ACTUATOR ITEM 1 DESCRIPTION Hydraulic Cylinder 10 2 Hydraulic Manual Override Assembly On/Off Selector Valve Pressure Relief Valve (factory set) Hydraulic Reservoir Drain Plug HP Push/Pull Pump 2 Manual Holding Valve 9 10 Fill Port / Vented Plug Local / Remote Selector Valve (HPB only) Page of Publication PUB01-00-00 Date of issue 0/1

OIL SPECIFICATION.0 Hydraulic Oil Specification Manufacturer: Trade name: Viscosity at 0 C: Viscosity at 100 C: Mobil DTE 10 Excel 2. cst. cst Viscosity index ASTM: 1 ISO Grade: 2 Pour point: Density at 1 C: - C 0. kg/l Note: This is the standard hydraulic oil specification for Rotork Fluid Systems actuators. If an alternative was specified and/or supplied, it is noted in job specific documentation, which is available upon request. Page of Publication PUB01-00-00 Date of issue 0/1

A full listing of our worldwide sales and service network is available on our website. www.rotork.com Corporate Headquarters Rotork plc tel + (0)122 200 fax + (0)122 email mail@rotork.com Electric Actuators and Control Systems Fluid Power Actuators and Control Systems Gearboxes and Gear Operators Precision Control Instruments Projects, Services and Retrofit PUB01-00-00 Issue 0/1 Formerly F12E. As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com The name Rotork is a registered trademark. Rotork recognises all registered trademarks. Published and produced in the UK by Rotork Controls Limited. ROWMH01