G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Similar documents
G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Standby Rating 220/ / / / / /

Model: 180REOZJD. Standard Features. Ratings Range 60 Hz Standby: kw kva Prime: kw kva Generator Set Ratings

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Ratings Range 50 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

KH04830TO4D 230/ / / / /

KH06810TO4D 230/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

KH08430TO4D 277/ / / / /

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. Standard Features

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

KH05520TO4D 254/ / / / /

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

Industrial Generator Set Accessories

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

POWER MODULE MTU 16V4000 DS2560

60 Hz FEATURES. Exclusively from your Caterpillar dealer

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Model: TD200 UCI274J / / /

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENERATOR SET MTU 18V2000 DS1400

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

DIESEL GENERATOR SET MTU 16V2000 DS1000

Spark-Ignited Generator Set Model GGKC 60 Hz

Spark-Ignited Generator Set Model GGKD 60 Hz

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

Diesel generator set QSK23 series engine

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

DIESEL GENERATOR SET. 60 Hz FEATURES

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

RENTAL DIESEL GENERATOR SET

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SETS

Diesel generator set QSK23 series engine

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Diesel generator set QSX15 series engine

DIESEL GENERATOR SET DP01800D5S

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva

DIESEL GENERATOR SET MTU 16V2000 DS KVA

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Model DKAC 60 Hz EPA Emissions

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

DIESEL GENERATOR SET MTU 20V4000 DS3250

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva Sound Attenuation: at 7m / 23 ft

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Diesel Generator Set Model DFJD 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

DIESEL GENERATOR SET MTU 16V4000 DS2250

Diesel generator set QSX15 series engine

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

DIESEL GENERATOR SET MTU 12V4000 DS2000

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

DIESEL GENERATOR SET DP03000D5S

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Spark-ignited generator set

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

2500 Prime 2200 Continuous

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET DS01650D5S

Transcription:

G100U MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz G100U 80-100 kw /80-5 kva 71-94 kw / 71-118 kva GAS GENSET STANDARD FEATURES General features : SDMO Industries provides one-source responsibility for the generating system and accessories. The generator set and its components are prototype-tested, factory-built and production-tested. The 60 Hz generator set offers a UL 2200 listing. The generator set accepts rated load in one step. Alternator features : Excitation system delivers excellent voltage response and short circuit capability using a permanent magnet (PM) excited alternator. The brushless, rotating-field alternator has broadrange reconnectability. Others features : The electronic, isochronous governor incorporates an integrated drive-by-wire throttle body actuator delivering precise frequency regulation. o Controllers are available for all applications. See controller features inside. GENERATOR RATINGS Natural Gas LP Gas Alternator Voltage HZ Phase 130 C Rise 105 C Rise 130 C Rise 105 C Rise Standby Rating Prime Rating Standby Rating Prime Rating KW / kva Amps KW / kva Amps KW / kva Amps KW / kva Amps 0/208 60 3 90/113 3 81/101 280 100/5 347 91/114 316 7/220 60 3 90/113 295 81/101 265 100/5 328 91/114 299 0/240 60 3 90/113 271 81/101 243 100/5 301 91/114 274 4S9 0/240 60 1 80/80 333 71/71 296 80/80 333 71/71 296 139/240 60 3 90/113 271 81/101 243 100/5 301 91/114 274 220/380 60 3 90/113 167 81/101 153 100/5 167 91/114 156 277/480 60 3 90/113 135 81/101 1 100/5 150 91/114 137 347/600 60 3 90/113 108 81/101 97 100/5 0 91/114 109 0/208 60 3 100/5 347 91/114 316 100/5 304 91/114 316 7/220 60 3 100/5 328 91/114 299 100/5 289 91/114 299 0/240 60 3 100/5 301 91/114 274 100/5 278 91/114 274 4S13 0/240 60 1 90/90 375 82/82 342 94/94 262 85/85 354 139/240 60 3 100/5 301 91/114 274 100/5 318 91/114 274 220/380 60 3 100/5 190 91/114 173 100/5 152 91/114 173 277/480 60 3 100/5 150 91/114 137 100/5 144 91/114 137 347/600 60 3 100/5 0 91/114 109 100/5 139 91/114 109 4V11 0/240 60 1 86/86 358 77/77 321 95/95 396 85/85 354 RATINGS: All three phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. STANDBY RATINGS: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS5514, AS 2789 and DIN6271. PRIME POWER RATINGS: Prime Power Ratings apply to installation where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS2789 and DIN6271. For limited running time and base load ratings, consult the factory. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 1.3% per 100m (328 ft) elevation above 200m (656 ft). Temperature: Derate 3.0% per 10 C (18 F) temperature above 40 C (104 F). CONDITIONS OF SALE SDMO provides a full line of products with high quality recognized engines and alternators. Service and parts are available from SDMO distributors as a single source of responsibility. Each and every unit is factory tested. All generator sets are also prototype tested. Warranty according to our standard conditions. G100U (Lit P/N F4-013) specifications and design liable to modifications without prior notice 1/5

ENGINE DATA Manufacturer / Model Cylinder Arrangement Displacement Bore and Stroke Compression ratio Rated RPM Piston Speed Main bearing: quantity, type Max. stand by Power at rated RPM kw (HP) Cylinder head material Piston type and material Crankshaft material Valve (exhaust) material Frequency regulation, no load to full-load Frequency regulation, steady state Frequency Governor : type Air cleaner type, all models Exhaust System Exhaust manifold type Exhaust flow at rated kw, m 3 /min (cfm) Exhaust temperature at rated kw, dry exhaust, C ( F) Maximum allowable back pressure, kpa (in.hg) Exhaust outlet size at engine hookup, mm (in.) Engine Electrical System Ignition system Battery charging alternator : Ground (negative/positive) Negative Ampere rating Starter motor rated voltage (DC) Battery, recommended cold cranking amps (CCA):Qty., rating for 18 C (0 F) Battery, recommended cold cranking amps (CCA):Battery voltage (DC) Fuel System Fuel type Fuel supply line inlet Natural Gas/LPG fuel supply pressure, measured at the generator set fuel inlet after any fuel system equipment accessories, kpa (in. H2O) Lubricating system Type Oil pan capacity, L [qt.] Oil pan capacity with filter, L [qt.] Oil filter : quantity, type Cooling Radiator System Ambient temperature, C [ F] Engine jacket water capacity, L [gal.] Radiator System capacity, including engine, L [gal.] Engine jacket water flow, Lpm [gpm] Heat rejected to cooling water at rated kw, dry exhaust, kw [Btu/min] Water pump type Fan diameter, including blades, mm [in.] Fan, kwm [HP] Max. Restriction of cooling air, intake and discharge side of radiator, kpa [in.h2o] General Motors Industrial Powertrain, Vortec 8.1 L, 4-cycle, Natural Aspiration V-8 8.1 L [496C.I.] 108mm [4.25in.] X111mm [4.37in.] 9.1 : 1 1800 Rpm 399m/min [1311ft./min] Alum; Lead Silico Alloy 1kW [162HP] Cast Iron Strutless Flat Top, Hypereutectic Cast Alum. Cast Nodular Undercut, Rolled Fillet Int.-A193Exh.Inconel Isochronous +/- 0.5 % Field-Convertible Electronic 20.8 [735] 677 C [50 F] 10.2 kpa [3.0 in. Hg] 89mm [3.5 in]od Individual Coil, Near Plug Ignition Negative 70 1, 630 LP Gas or Natural Gas, 1 NPTF 1.74-2.74 kpa [7.0-11.0 in H2O) Full Pressure 7.6 L [8.0qt] 8.0 L [8.5 qt] 1, Cartridge 50 C [2 F] 10.0L [2.6 gal] 25.7L [6.8 gal] 5Lpm [33 gpm] 73kW [4140 Btu/min] Centrifugal 599mm [23.6 in] 6.7kWm [9.0HP] 0.5kPa [0.5 in H2O] Enclosure with enclosed silencer reduces ambient temperature capability by 10 C (18 F. Enclosure with roof-mounted silencer reduces ambient temperature capability by 5 C (9 F). Cooling Remote Radiator System Exhaust manifold type Connection sizes :Water inlet, ID hose, mm [in] Connection sizes :Water outlet, ID hose, mm [in.] Static head allowable above engine, kpa (ft. H2O] 44.45 mm [1.75 in] 38.10mm [1.50 in] 4.32mm [17.0 in] Contact your local distributor for cooling system options and specifications based on your specific requirements. G100U (Lit P/N F4-013) specifications and design liable to modifications without prior notice 2/5

Air requirements Radiator-cooled cooling air, m 3 /mi. [scfm] Cooling air required for generator set when equipped with city water cooling or remote radiator, based on 14 C [25 F] rise and ambient temperature of 29 C [85 F], m 3 /min [cfm] Combustion air, m 3 /min [cfm] Heat rejected to ambient air: Engine, kw [Btu/min.] Heat rejected to ambient air : Alternator, kw [Btu/min] 198 m 3 /min [7000 scfm] 220 m 3 /min [7750 scfm] 7.1 m 3 /min [250 scfm] 47.6m 3 /min [2710 scfm] 13.7 m 3 /min [780 scfm] Air density = 1.20 kg/m 3 [0.075 lbm/ft 3 ] Fuel Consumption Natural Gas, m3/hr [cfh] at % load 0% Natural Gas, m3/hr [cfh] at % load LP Gas, m3/hr [cfh] at % load LP Gas, m3/hr [cfh] at % load Fuel consumption is based on 1015 Btu/standard cu.ft. natural gas. Standby Ratings 33.0[1164] 25.3 [893] 21.1 [745] 13.2 [466] 7.3 [257] Prime Ratings 30.2 [1065] 24.1 [852] 19.7 [694].6 [447] 7.3 [257] Standby Ratings 14.5 [511] 11.4 [403] 8.7 [306] 5.5 [195] 2.9 [104] Prime Ratings 13.4 [472] 10.7 [377] 8.1 [285] 5.3 [187] 2.9 [104] G100U (Lit P/N F4-013) specifications and design liable to modifications without prior notice 3/5

ALTERNATOR SPECIFICATIONS General Data NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. Self-ventilated and dripproof construction. Vacuum-impregnated windings with fungus-resistant epoxy varnish for dependability and long life. Superior voltage waveform from a two-thirds pitch stator and skewed rotor Permanent magnet, brushless alternator with brushless exciter for excellent load response. Alternator Data Type Exciter type Wound Field (WF) Exciter type Permanent magnet (PM) Leads : quantity, type -4S9W/4S9, 4S13W/4S13 Leads : quantity, type -4V11W/4V11 Insulation : Material, Temperature rise Voltage regulator Bearing : quantity, type Coupling Other Alternator Data Amortisseur windings Voltage regulation, no-load to full-load, Permanent magnet (PM) alternator 500 controller (with 0.5% drift due to temperature variation) Unbalanced load capacity One-step load acceptance Peak motor starting kva : 480 V 4S9 ( lead) 480 V 4S13 ( lead) 480 V 4S9 ( lead) 4-Pole, Rotating-Field Wound Exciter Field with Separate Excitation Power Winding Brushless, Permanent-Magnet, Reconnectable 4,110-0/220-240 NEMA MG1, Class H, 130 C, Standby Solid State, Volts/Hz 1, Sealed Flexible Disc Full +/- 2 % Average 3-Phase Sensing, +/-0.25 % of Rated Standby Current of Rating (35% dip for voltages below) 315 (60 Hz) 510 (60 Hz) _ (60 Hz) CONTROL PANEL XC500 Audiovisual annunciation with NFPA 110 Level 1 capability. Programmable microprocessor logic and digital display features. or 24 volts engine electrical system capability. Remote start, remote annunciation and remote communication options. Refer to F6-46 for additional controller features and accessories. XC200 Audiovisual annunciation with NFPA 110 Level 1 capability. Microprocessor logic, AC meters and engine gauge features. - or 24-volts engine electrical system capability. Remote start, prime power and remote annunciation options. G100U (Lit P/N F4-013) specifications and design liable to modifications without prior notice 4/5

OPTIONS Engine and Alternator Cooling system Controller (XC500 and 16-Light) Alternator, Wound Field (WF) Block Heater [recommended for ambient Common Failure Relay Kit Safeguards Breaker (not available temperature below 10 C (50 F)] Communication Products and PC with XC500 controller) Remote radiator Cooling Software (XC500 controller only) Alternator, Permanent Magnet (PM) City Water Cooling Customer Connection Kit Air Cleaner Restrictor Indicator Radiator Duct Flange contact Kit (isolated alarm) Alternator Strip Heater Electrical system Engine Prealarm Sender Kit CSA Certification Battery Local Emergency Stop Kit Voltage Regulation, 1% Battery Charger, Equalize/Float Type Prime Power Switch (XC500 controller Engine Fluids (oil and coolant) Added Battery Heater only) Line Circuit Breaker (NEMA1 enclosure) Open Unit Remote Annunciator Panel Line Circuit Breaker with Shunt Trip Flexible Exhaust Connector, Stainless Remote Audiovisual Alarm Panel (NEMA1 enclosure) Steel Remote Emergency Stop Kit Optional Alternators Exhaust Silencer, Critical (kits : PA- Remote Mounting Cable Rated Power Factor Testing 324292, PA-324470) Run Relay Kit Rodents Guards Enclosure Literature and Maintenance Voltage Regulation Sensing, Three- Sound Enclosure (with enclosed critical General Maintenance Literature Kit Phase silencer) Maintenance Kit (includes standard Fuel Weather Enclosure (with enclosed critical Air, oil and fuel filters) Flexible Fuel Lines silencer) NFPA 110 Literature LP Gas Liquid Withdrawal Weather Housing (with roof-mounted Overhaul Literature Kit Gas Filter silencer) Production Literature Kit Manual Valve Additional Standard Features Secondary Gas Solenoid Valve Alternator Protection (standard with XC500 controller) Battery Rack and Cables Electronic, Isochronous Governor Integral Vibration Isolation Oil Drain Extension Operation and Installation Literature WEIGHT AND DIMENSIONS Overall size l x w x h : Wide Skid : 2400mm [94.5in] x 1040mm [40.9in] x 1484mm [58.4in] Narrow Skid : 2400mm [94.5in] x 865mm [34.1in] x 1484mm [58.4in] Weight (radiator model), wet, kg (lb): 1134kg [2500lbs] NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. SDMO - Head Office Bis Rue de la Villeneuve, CS 92848, 29228 Brest Cedex 2, FRANCE Phone : +33 (0) 2 98 41 41 41, Fax : +33 (0) 2 98 41 63 07 - www.sdmo.com G100U (Lit P/N F4-013) specifications and design liable to modifications without prior notice 5/5