Data sheet: Wilo-CronoLine-IL-E 100/150-15/2-R1

Similar documents
Data sheet: Wilo-CronoLine-IL-E 40/170-5,5/2

Data sheet: Wilo-CronoLine-IL-E 65/170-11/2-R1

Data sheet: Wilo-CronoLine-IL-E 100/220-5,5/4-R1

Data sheet: Wilo-VeroLine-IP-E 40/130-2,2/2-R1

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Data sheet: Wilo-CronoLine-IL 100/250-5,5/4

Data sheet: Wilo-CronoLine-IL 40/220-1,5/4

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Data sheet: Wilo-VeroTwin-DPL 65/ /2

Data sheet: Wilo-VeroLine-IPL 100/ /4

Data sheet: Wilo-VeroLine-IPL 65/ /2

Data sheet: Wilo-VeroTwin-DPL 40/ /4

Data sheet: Wilo-Stratos-D 32/1-8

Data sheet: Wilo-Stratos-D 50/1-12

Data sheet: Wilo-VeroLine-IPL 65/ /2

Data sheet: Wilo-VeroTwin-DPL 50/ /4

Data sheet: Wilo-Stratos-Z 25/1-8

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Data sheet: Wilo-VeroLine-IPH-W 65/ /4

Data sheet: Wilo-CronoNorm-NL 150/315-37/4

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Data sheet: Wilo-Yonos PICO 25/

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Series description: Wilo-Stratos

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Stratos PICO 25/

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Series description: Wilo-Stratos ECO-STG

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

Data sheet: Wilo-Economy MHI 202 (3~400 V, EPDM)

Heating, air-conditioning, cooling

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Series description: Wilo-TOP-STGD

Heating, air-conditioning, cooling

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Inline Pumps. Product review. Wilo-VeroLine-IPL. Single-head pumps: Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

SIE BV/ED EVS. SINGLE HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 et 60 Hz. operating limits SIE BV/ED

Glanded Pumps. Catalogue Heating, Air-Conditioning, Cooling. In-Line Pumps and Accessories. Catalogue A2-50 Hz

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

NB80-160/161 A-F2-A-BQQE

Company name: Created by: Phone:

Axially Split Case Pumps

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

CRE15-01 A-F-A-E-HQQE 1x HZ

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

NBE50-250/205 A-F2-A-BAQE

CRNE AN-F-G-E-HQQE 3x HZ

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

Company name: Created by: Phone:

CRE45-1 A-F-A-E-HQQE 3x HZ

Company name: Created by: Phone:

CRE10-12 AN-FJ-A-E-HQQE 3x HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

Tender Text. Company name: Created by: Phone: Date: 3/13/2017. Product No.: CRE 5-20 AN-FGJ-A-E-HQQE

Series description: Wilo-MultiCargo MC

Wilo-CronoLine-IL-E Wilo-CronoTwin-DL-E Wilo-CronoBloc-BL-E

CRE20-08 A-F-A-E-HQQE 3x HZ

MULTI VE THREE-PHASE JETSON

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

Pressure boosting Single pumps

Series description: Wilo-DrainLift KH 32

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

High Pressure Centrifugal Pumps Product Overview

CRE A-F-A-E-HQQE 3x HZ

Series description: Wilo-Drain MTC

CRE A-F-A-E-HQQE 3x HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017

NBE40-125/139 AS-F2-A-BAQE

CRI1S-25 A-P-I-E-HQQE 1x220/240 50HZ

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017

CRE32-3 AN-F-A-E-HQQE 3x HZ

4 Specification Magneta Smedegaard twin pumps

Grundfos pump

CRE20-03 A-A-A-E-HQQE 3x HZ

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

DIE TWIN HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 Hz

Series description: Wilo-TOP-S

Monobloc and Norm Pumps, Axially Split Case Pumps

Note! Product picture may differ from actual product

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Series description: Wilo-Drain STS 40

CRN5-8 A-P-G-V-HQQV 3x230/400 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

NB /193 A-F2-A-BAQE

LPCD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

VM Series Vertical Multistage Pumps. VM Series Multistage Pumps APPLICATIONS WHY CHOOSE THE VM SERIES MULTISTAGE PUMPS? Experts in water.

3 Specification Magneta Smedegaard

TPED /4-A-F-A-BQQE 3X400 50HZ

Transcription:

Data sheet: Wilo-CronoLine-IL-E 1/1-1/2-R1 Pump curves 2-pole H/m 3 2 2 1 1 P 1/kW 2% 1 1 2 2 1 1 Qmin n=constant 1% 9% 8% 7% 6% % 4% Wilo-CronoLine-IL-E 1/1-1/2 2 4 6 8% 9% 3 2 2 1 1 Q/l/s 1% 7% 6% % 2% 4% 1 1 2 2 H/m 3 2 Qmin Δp-c Wilo-CronoLine-IL-E 1/1-1/2 p/kpa p/kpa 3 2 Approved fluids (other fluids on request) Heating water (in accordance with VDI 23) Water-glycol mixtures (for 2-4 vol.% glycol and fluid temperature 4 C) Cooling and cold water Heat transfer oil Permitted field of application Standard version for operating pressure Special version for operating pressure p max p max Temperature range at max. ambient temperature +4 C Special version at additional charge 13 bar (up to +14 C) bar 16 bar (up to +12 C) bar -2...+14 C (depending on the fluid) Max. ambient temperature +4 C Installation in closed buildings Outdoor installation Pipe connections 2 Δp-v max. 2 Nominal flange diameter DN 1 1 1 Flanges (according to EN 192-2) PN 16 1 1 Flange with pressure-measurement connections R 1 / 8 1 1 2 2 Materials Δp-c P 1/kW 1 NPSH/m 12 2 4 6 26m 2m 2m 8m 14m 1 1 2 2 8 4 η hyd. NPSH 1 1 2 2 Q/l/s η hyd./% 8 4 Pump housing EN-GJL-2 Lantern EN-GJL-2 Impeller EN-GJL-2 Impeller (special version) G-CuSn1 Pump shaft 1.4122 Mechanical seal AQEGG Other mechanical seals On request Electrical connection Mains connection 3~44 V, /6 Hz 3~4 V, /6 Hz 3~38 V, /6 Hz Speed n 7-29 rpm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI).4 Pump with max. impeller diameter for determining the MEI IL1/17-3/2 Subject to change without prior notice. www.wilo.co.uk Hz 21-2 1 / 8

Data sheet: Wilo-CronoLine-IL-E 1/1-1/2-R1 Dimension drawing 3 x M12 x 2 8 x Ø 19 226 6 2 DN 1 32 Ø 22 Ø 18 Ø 16 13 12 77 6 226 Ø18 4 32 19 197 416 2 2xM12/1xM16/1xM2/1xM4 Motor/electronics Motor technology Integrated full motor protection Asynchronous motor Protection class IP Insulation class Emitted interference EN 618-3 Interference resistance EN 618-3 Residual-current protection device (RCD) No. of poles 2 Rated current (approx.) I N 3~4 V F 26. A Maximum power consumption P 1 16.6 kw Nominal motor power P 2 1. kw Installation options Pipe installation ( 1 kw motor power) Support-bracket mounting Information for order placements Weight approx. m 218 kg Make Wilo Type CronoLine-IL-E 1/1-1/2- R1 Art no. 211448 Three-phase motor (DM), 2-pole - 3~4V, Hz / 3~38V, 6 Hz Please observe pump name plate data Subject to change without prior notice. www.wilo.co.uk Hz 21-2 2 / 8

Dimensions and dimension drawings: Wilo-CronoLine-IL-E 1/1-1/2-R1 Dimension drawing 32 13 12 77 4 32 2xM12/1xM16/1xM2/1xM4 3 x M12 x 2 8 x Ø 19 226 6 2 DN 1 Ø 22 Ø 18 Ø 16 6 226 Ø18 19 197 2 416 Subject to change without prior notice. www.wilo.co.uk Hz 21-2 3 / 8

Pump curves: Wilo-CronoLine-IL-E 1/1-1/2-R1 Pump curves 2-pole H/m 3 2 Qmin n=constant 1% Wilo-CronoLine-IL-E 1/1-1/2 p/kpa 3 2 2 1 9% 8% 7% 2 1 1 6% % 4% 2% 1 1 2 2 2 4 6 1 Q/l/s P1/kW 1 1 8% 9% 1% 7% 6% % 2% 4% 1 1 2 2 H/m 3 2 Qmin Δp-c Wilo-CronoLine-IL-E 1/1-1/2 p/kpa 3 2 2 Δp-v max. 2 1 1 1 1 Δp-c P1/kW NPSH/m 12 1 1 2 2 1 2 4 6 26m 2m 2m 8m 14m 1 1 2 2 8 4 η hyd. NPSH 1 1 2 2 Q/l/s η hyd./% 8 4 Subject to change without prior notice. www.wilo.co.uk Hz 21-2 4 / 8

Ordering information: Wilo-CronoLine-IL-E 1/1-1/2-R1 Information for order placements Make Type Wilo CronoLine-IL-E 1/1-1/2-R1 Art no. 211448 EAN number 4484821273 Colour Green Minimum order quantity 1 Minimum order quantity unit PCE Weight (net) kg 218 Length (net) mm 89 Width (net) mm 36 Height (net) mm 666 Weight (gross) kg 243 Length (gross) mm 12 Width (gross) mm 8 Height (gross) mm 81 Subject to change without prior notice. www.wilo.co.uk Hz 21-2 / 8

Specification texts: Wilo-CronoLine-IL-E 1/1-1/2-R1 Glanded centrifugal pump with in-line design for pipe installation with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Design: Single-stage low-pressure centrifugal pump Spiral housing in in-line design (suction and pressure ports with the same flanges in one line), flanges PN 16 drilled acc. to EN 192-2 Pressure measuring connections (R 1/8) for mounted differential pressure sensor Pump housing and motor flange with cataphoretic coating as standard. Mechanical shaft seal for water feed up to T=14 C; up to Tmax= +4 C a glycol admixture of 2 to 4 % by vol. is permitted. Special mechanical shaft seals for water/glycol mixtures deviating from the 2 4 % glycol by volume and a fluid temperature of 4 C or fluids other than water (additional charge). Accessories: Mounting brackets for fixing to the foundation IR Monitor IR-Stick IF-Module PLR IF module LON IF-Module Modbus IF-Module BACnet CAN IF-Module Control systems VR-HVAC/CCe-HVAC/SCe-HVAC DDG sets Standard equipment: One-button manual operation level for: Pump display for displaying: Additional functions: Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 1 V, 2 1 V, 2 ma, 4 2 ma for manual control mode (DDC) or for remote setpoint adjustment, analogue input 1 V, 2 1 V, 2 ma, 4 2 ma for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service device Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo IF-Module for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication Three-phase AC motor with frequency converter Integrated dual pump management Adjustable time interval for pump cycling (in dual pump mode) Integrated full motor protection Different operating modes for heating mode (HV) or air-conditioning mode (AC) Access disable Different operation levels: Standard / Service Materials Pump housing: EN-GJL-2 Lantern: EN-GJL-2 Impeller: EN-GJL-2 Pump shaft: 1.4122 Mechanical seal: AQEGG Permitted field of application Standard version for operating pressure: 13 bar (up to +14 C) / bar16 bar (up to +12 C) bar Subject to change without prior notice. www.wilo.co.uk Hz 21-2 6 / 8

Specification texts: Wilo-CronoLine-IL-E 1/1-1/2-R1 Temperature range at max. ambient temperature +4 C: -2...+14 C (depending on the fluid) Max. ambient temperature: +4 C Pipe connections Nominal flange diameter: DN 1 Overall length: mm Flanges (according to EN 192-2): PN 16 Flange with pressure-measurement connections: R 1 / 8 Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI):.4 Pump with max. impeller diameter for determining the MEI: IL1/17-3/2 Motor/electronics Integrated full motor protection: Protection class: IP Insulation class: F Emitted interference: EN 618-3 Interference resistance: EN 618-3 Mains connection: 3~44 V, /6 Hz / 3~4 V, /6 Hz / 3~38 V, /6 Hz Speed: 7-29 rpm No. of poles: 2 Rated current (approx.): 26. A Maximum power consumption: 16.6 kw Nominal motor power: 1. kw Weight Weight approx.: 218 kg Information for order placements Art no.: 211448 Type: CronoLine-IL-E 1/1-1/2-R1 Make: Wilo Subject to change without prior notice. www.wilo.co.uk Hz 21-2 7 / 8

Terminal diagram : Wilo-CronoLine-IL-E 1/1-1/2-R1 Terminal diagram L1 L2 L3 PE PE SBM AUX Ext. off L H In2 GND In1 GND +24V MP (1) (2) (3) DDG O S OFF ON SSM L1, L2, L3: PE: DDG: In1 (1): GND (2): + 24 V (3): In2: MP: Ext. off: SBM:* SSM:* aux: DIP switch: Optional: Mains connection: 3~44 V ±1%, /6 Hz; 3~4 V ±1%, /6 Hz; 3~38 V -%/+1%, /6 Hz Protective conductor connection Connection for differential pressure sensor Actual value input -1 V/-2 ma; 2-1 V/4-2 ma Ground connection for In1 and In2 DC voltage output for an external consumer/sensor. Max load 6 ma Setpoint input -1 V/-2 ma; 2-1 V/4-2 ma Multi-pump, interface for dual pump management Control input Overriding Off The pump can be switched on or off via an external, potential-free contact (24 V DC/1 ma). Potential-free collective run signal (changeover contact according to VDI 3814) Potential-free collective fault signal (changeover contact according to VDI 3814) External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/1 ma) 1: Switchover between operation (O) and service mode (S) 2: Activate/deactivate the menu for access disable IF-Modules for connection to the building automation Subject to change without prior notice. www.wilo.co.uk Hz 21-2 8 / 8