GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

Similar documents
GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GMR - 67P 67P 09/05/2016 GMR - 067P

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GQW1400V. 1MWe TWINGEN in container 20 HC

THE COMPLETE PETROL PACKAGE

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

MODEL GSW Deutz.

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

P6000s 230V 50Hz #CONN #DPP

S V50HZ #AVR #CONN #DPP

P V 50HZ #CONN #DPP

Rating Definitions and Conditions

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Rating Definitions and Conditions

Rating Definitions and Conditions

MODEL GSW80 Deutz & 110 Perkins.

Model NA 2 L

Standby Amper VOLTAGE

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

1 / Genset general description

Model MP150 W W

Better Soundproof, Better Life!

Rating Definitions and Conditions

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Standby Amper VOLTAGE

Rating Definitions and Conditions

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

GE.PK.022/020.SS+0_all

Super Silent, Superior Life!

Voltage. kva kw kva kw

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1 / Genset general description

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

19 KW / 24 KVA POWERED by

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Rental Power QSL9 series engine

MODEL GBW15-22 Yanmar

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

1 / Genset general description

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

CUKUROVA GENERATOR SYSTEMS

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

TECHNICAL SPECIFICATIONS

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

CUKUROVA GENERATOR SYSTEMS

Rental Power QSB7 series engine

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

LWALR LIQUID COOLED LONG RUNNING GENSETS

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

Transcription:

GMS-110V Power Rating Standby power LTP kva 112.95 Standby power LTP kw 90.36 Prime power PRP kva 101.42 Prime power PRP kw 81.14 Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

Engine specifications Engine manufacturer Model [50Hz] Exhaust emission level Engine cooling system Nr. of cylinder and disposition Volvo TAD531GE Stage II Water 4 in line Displacement cm³ 4760 Aspiration Speed governor Turbocharged intercooled Mechanical Prime gross power PRP kw 92 Maximum gross power LTP kw 102 Oil capacity l 13 Coolant capacity l 19.7 Fuel Diesel Specific fuel consumption @ 75% PRP g/kwh 217 Specific fuel consumption @ PRP g/kwh 219 Starting system Electric Starting engine capability kw 3.1 Electric circuit V 12 ENGINE EQUIPMENT Standards The engine performance corresponds to ISO 3046, BS 5514 and DIN 6271. Power output guaranteed within 0 to +2% att rated ambient conditions at delivery. Ratings are based on ISO 8528. Engine speed governing in accordance with ISO 3046/IV, class A1 and ISO 8528-5 class G3 Engine and block Optimized cast iron cylinder block with optimum distribution of forces Drop forged steel connecting rods Keystone top compression rings for long service life Replaceable valve guides and valve seats Fuel system Washable fuel prefilter with water separator Fine fuel filter of disposable type Rotary low-pressure fuel pump Lubrication system Rotary displacement oil pump driven by the crankshaft Deep centre oil sump Oil filler on top Oil dipstick, short in front Integrated full flow oil cooler, side-mounted Integrated full flow oil cooler, sidemounted Cooling system Belt driven, maintenance-free coolant pump with high degree of efficiency Efficient cooling with accurate coolant control through a water distribution duct in the cylinder block Reliable thermostat with minimum pressure drop

Alternator Specifications Alternator Mecc Alte Model ECP34-2S/4 Voltage V 400 Frequency Hz 50 Power factor cos ϕ 0.8 Poles 4 Type Brushless Voltage regulation system Electronic Standard AVR DSR Voltage tolerance % 1 Efficiency @ 75% load % 92.5 Class H IP protection 23 Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DSR. The digital DSR controls the range of voltage, avoiding any possible trouble that can be made by unskilled personnel. The voltage accuracy is ±1% in static condition with any power factor and with speed variation between 5% and +30% with reference to the rated speed. Windings / Excitation system Generator stator is wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for troublefree supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. MAUX (Standard): The MAUX MeccAlte Auxiliary Winding is a separate winding within the main stators that feeds the regulator. This winding enables to take an overload of 300% forced current (short circuit maintenance) for 20 seconds. This is ideal for motor starting requirements. Insulation / Impregnation Insulation is of class H standard. Impregnation is made with premium tropicalised epoxy resins by dipping and dripping. High voltage parts are impregnated by vacuum, so the insulation level is always very good. In the high-power models, the stator windings undergo a second insulation process. Grey protection is applied on the main and exciter stator to give enhanced protection. Reference standards Alternator manufactured according to, and complies with, the most common specification such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/ CSA-C22.2 No14-95-No100-95.

Genset equipment BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH: Anti-vibration mountings properly sized Welded or Screwed support legs. (according to canopy size) PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: Filler neck Air breather (ventilation pipe) Minimum fuel level sensor OIL DRAININ PIPE WITH CAP: Oil draining facilities ENGINE COMPLETE WITH: Battery Liquids (no fuel) CANOPY: Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles; Detachable panels, with screws holes protected by rubber tap. Control panel protection door provided with suitable window and lockable handle. Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. Single detachable lifting eye placed on the roof. SOUNDPROOF: Noise attenuation thanks to soundproofing material Efficient residential silencer placed inside the canopy

Dimensional data Length (L) mm 3000 Width (W) mm 1150 Height (H) mm 1760 Dry weight Kg 1727 Fuel tank capacity l 350 Noise level Guaranteed noise level (LWA) db(a) 97 Noise pressure level @ 7 mt db(a) 68 Data Current Battery capacity Ah 140 Circuit breaker A 160 Control panel availability AUTOMATIC CONTROL PANEL ACP MODULAR PARALLEL PANEL MPP

ACP - Automatic control panel Mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set, protected through door with lockable handle DIGITAL INSTRUMENTATION Generating set voltage (3 phases) Mains voltage Generating set frequency Generating set current (3 phases) Battery voltage Power (kva - kw - kvar) Power factor Cos φ Hours-counter Engine speed r.p.m. Fuel level (%) Engine temperature (depending on model) COMMANDS AND OTHERS Four operation modes: OFF - Manual starting - Automatic starting - Automatic test Pushbutton for forcing Mains contactor or Genset contactor Push-buttons: start/stop, fault reset, up/down/page/enter selection Remote starting availability DC system disconnection switch Acoustic alarm Automatic battery charger RS232 Communication port Settable PASSWORD for protection level PROTECTIONS WITH ALARM Engine protections: low fuel level, low oil pressure, high engine temperature Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure Circuit breaker protection: III poles Earth Fault included in the control unit OTHERS PROTECTIONS Emergency stop button Panel protected through door with lockable handle OUT PUT PANEL ACP Power cables connection to Circuit Breaker. Predisposed for remote control optional: RCG External Terminal Board (ETB) Optional Socket kit Optional

MPP - Modular parallel panel Mounted on the genset, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple gen-sets operating in standby or parallel modes (up to 32 gen-sets in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) Mains: voltage, Intensity, Frequency. Mains kw - kvar -Power factor Cos f. Genereting set voltage (3 phases). Generating set frequency. Generating set current (3 phases). Generating set Power (kva - kw - kvar). Generating set Power factor Cos f. Generating set kwh and kvah. Battery voltage. Hours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). COMMAND AND OTHERS Graphical display 128x64 pixels. Operation modes: OFF - AMF function - Single Parallel to mains Island application - Single Parallel to Mains AMF application - Mulitple parallel genset Island application. Pushbutton for forcing Mains Breaker/contactor or Genset Breaker/contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Multiple parallel and Power Management operation with digital load AVR sharing. Automatic synchronizing and power control (via speed goveroner or ECU) Baseload Import/Export and Peak shaving Voltage and PF control (AVR). Configurable digital I/O (12/12) and analogue inputs (3). Integrate PLC programmable functions. Event-based history (up to 500records). Selectable measurment range 120/277V and 0-1/0-5A. Remote starting and Blocking signal availability. DC system disconnection switch. Acoustic alarm. Automatic battery charger. 2xRS232/RS485/USB Comuncation ports. Setable PASSWORD for protection level. PROTECTION WITH ALARM AND SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Others: overcurrent, shortcircuit, reverse power, Earth fault OTHERS PROTECTION: Circuit breaker protection: IV poles Motorized. Emergency stop button. Panel protected through door with lochetable handle OUT PUT PANEL MPP Multi-pin connectors (in and out ) for parallel with other generators n 2 Connecting cable with 2 connectors multipin (length 10m) n 1 ETB External terminal board ETB

Supplements: Only Available when order : CONTROL PANEL SUPPLEMENT RCG - Various supplements for remote controls - available for models: TLP - Various supplements for remote signals - available for models: ADI - Adjustable Differential Intensity - available only for models: TIF - IV Poles Circuit Breaker instead of III - available for models: ACP MPP ACP MPP ACP ACP Socket kit Component version IP67 Individual CB and Earth Fault protection 3P+N+T 400V 63A IP67 n 1 230V/16A 2P+T CEE IP67 n 1 230V 16A SCHUKO IP68 n 1 3P+N+T CEE 400V 16A IP67 n 1 NB: for assembly is necessary: ETB GENSET EQUIPMENT KPR - Premium Kit (Leak Proof Tray - Leakage detection sensor - Manual oil drain pump) AFP - Automatic Fuel Pump KRT - Kit Rental which includes fuel filter with water separator, 3-way fuel valve, battery switch, earth rod, docs folder) ACP MPP Extended Fuel Tank Fuel tank capacity l 1750 Length (Genset) (L) mm 3400 Width (Genset) (W) mm 1398 Height (Genset) (H) mm 2546 ENGINE SUPPLEMENTS PHS - Coolant Pre-Heating System - available for models: EEG - Engine Electronic Governor ACP MPP

Accessories Items available as accessory equipment STR - Site trailer RTR - Road Trailer LTS - LOAD TRANSFER SWITCH - Accessories ACP Automatic under-load change-over (AC22, AC23) from and to any of positions 1, 0, 2 both electrical and manual (emergency change-over), transfer function with direct transition from position 1 to position 2 and vice versa. Safety: locking by padlock preventing any electrical or manual operation, key lock for the selection of electrical or manual operation.- Quick operating time from pos. 1 to 2 and vice versa. Easy and fast electrical connections by means of terminal blocks of quick connection type. Conformity to standards: IEC 60947-1 IEC 60947-3, CEI EN 60947-1 / CEI EN 60947-3IEC 439-1, CEI EN 60439-1IEC 204-1, CEI EN 60204-1, VDE 0660 Teil 107 NOMINAL CURRENT & DIMENSIONS PANEL LTS (standard*) Nominal Current A 160 Width (W) mm 600 Height (H) mm 400 Depth (D) mm 200 * = Available electrical power more The information is aligned with the Data file at the time of download. Printed on 13/07/2017 (ID 6490) 2017 www.generacmobileproducts.com