Summary of the project SWD th November Project duration June 2015 to December Edited by

Similar documents
Comprehensive analysis energy efficiency of large buildings / halls Summary

ISO/TR TECHNICAL REPORT. Rolling bearings Explanatory notes on ISO 281 Part 1: Basic dynamic load rating and basic rating life

The Impact of E-Mobility on Distribution Grid Expansion? One Research Question, Many Answers

Grid Impact of Electric Vehicles with Secondary Control Reserve Capability

KBA Kraftfahrt-Bundesamt

Mobile Air Conditioning (MAC)

GLOBAL REGISTRY. Addendum. Global technical regulation No. 10 OFF-CYCLE EMISSIONS (OCE) Appendix

Concept Evaluation and Optimization of a 2-Stage Charging System

O B J E C T I V E NON-kind-Projects

Test Based Optimization and Evaluation of Energy Efficient Driving Behavior for Electric Vehicles

Thema der Arbeit. Discussion of IT-infrastructure for electric mobility. Bachelorarbeit. vorgelegt von. Patrick-Oliver Groß

Akku4Future. (Acronym: Akku4Future Dis)

ISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category

Sound-absorbing spacer Sorp10

UNIGLAS Tender Specifications

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Is Low Friction Efficient?

SIP-adus Workshop A Traffic-based Method for Safety Impact Assessment of Road Vehicle Automation. Tokyo, 14 th November 2018

ISO INTERNATIONAL STANDARD

Technical Committee Motor Vehicles 15 September RDE 3 discussion

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

Charging Electric Vehicles in the Hanover Region: Toolbased Scenario Analyses. Bachelorarbeit

Technological Viability Evaluation. Results from the SWOT Analysis Diego Salzillo Arriaga, Siemens

Safety Assessment & Approval System of Shanghai Maglev Demonstration Line and its Practice

HANNOVER MESSE Materials Forum

Add-on of the 2-MN force standard machine for testing load cells

Offshore Application of the Flywheel Energy Storage. Final report

OPTIMISING CHASSIS ALIGNMENT USING VEHICLE SENSORS

International Palm Oil Purchasing Policy

Customer Expectations and Technical Solutions for Third Generation Electric Vehicles

Proven to be better. Development trends in industrial rolling bearings

Excursion 2015 nach Heilbronn

ISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category

ISO INTERNATIONAL STANDARD

a) The 2011 Net Metering and Buyback Tariff for Emission Free, Renewable Distributed Generation Serving Customer Load

ENERGY STRATEGY FOR YUKON. Independent Power Production Policy

From the material to the cell

ISO INTERNATIONAL STANDARD. Road vehicles Brake lining friction materials Friction behaviour assessment for automotive brake systems

ELECTRICAL 48 V MAIN COOLANT PUMP TO REDUCE CO 2 EMISSIONS

Master Thesis Electric Vehicle Integration

DG system integration in distribution networks. The transition from passive to active grids

The District Heating Barometer, why and how

WELMEC European cooperation in legal metrology

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Net Metering Policy Framework. July 2015

Z from: 1 November 2016

Developing a Methodology for Certifying Heavy Duty Hybrids based on HILS

Evidence of performance Reduction of impact sound pressure level by floor coverings

Solar-Wind Specific Request for Proposals

FURTHER TECHNICAL AND OPERATIONAL MEASURES FOR ENHANCING ENERGY EFFICIENCY OF INTERNATIONAL SHIPPING

Vehicle Systems Engineering and Integration Activities - Phase 3

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar

Pattern evaluation programs for traffic speed measurement devices in PR China

Proceedings of the World Congress on Engineering 2008 Vol II WCE 2008, July 2-4, 2008, London, U.K.

Calculation on a valve housing flange

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

Determination of the integration and influencing potential of rapid-charging systems for electric vehicles in distribution grids

Highly dynamic control of a test bench for highspeed train pantographs

Energy Performance Information Request Timeline

CALL FOR APPLICATIONS FOR THE SELECTION OF MEMBERS OF THE TACHOGRAPH FORUM

Simulation of Collective Load Data for Integrated Design and Testing of Vehicle Transmissions. Andreas Schmidt, Audi AG, May 22, 2014

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Regulation No Uniform provisions concerning the approval of replacement pollution control devices for power-driven vehicles

CONSULTATION DOCUMENT

Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014

Electrical 48-V Main Coolant Pump to Reduce CO 2 Emissions

ISO 3934 INTERNATIONAL STANDARD

Chemical indicators and test devices Benchmarking sterilisation processes.

System Test Report Fitness for Use and Durability

Application of claw-back

Fuel Cell Application in a New Configured Aircraft PUBLISHABLE REPORT

Development of a Mobile Application for Android to Support Energy-Efficient Driving of Electric Vehicles

Model Legislation for Autonomous Vehicles (2018)

Operating instructions

Christian Theis 52 nd GRB, 6-8 September 2010, ASEP outline. Summary & Conclusion

ROLLOVER RIGHTS OF LONG TERM FIRM TRANSMISSION SERVICE

ELVI-System. Elevator Inspection System 2.0. Non destructive elevator testing

PENINSULA CLEAN ENERGY JPA Board Correspondence

HyLAW. HyDrail Rail Applications Assessment. Main Author(s): [Dainis Bošs, Latvian Hydrogen association] Contributor(s):

INCREASING electrical network interconnection is

Cost-Benefit Analysis of Options for Certification, Validation and Monitoring and Reporting of HDVs

Certification Scheme

Yukon s Independent Power Production Policy

CACTUS Models and Methods for the Evaluation and the Optimal Application of Battery Charging and Switching Technologies for Electric Busses

RECOMMENDATION: It is recommended that the City Council, following a public hearing, adopt the attached resolution which:

AIR POLLUTION AND ENERGY EFFICIENCY. Guidelines for onboard sampling and the verification of the sulphur content of the fuel oil used on board ships

ISO/TR TECHNICAL REPORT. Gears Thermal capacity Part 1: Rating gear drives with thermal equilibrium at 95 C sump temperature

Test report. About the effect of Lambda System Cleaning Products. No

Industry 4.0 Is Unthinkable Without Calibration!

STAFF REPORT ACTION REQUIRED

Explanatory document for the Nordic synchronous area proposal for ramping restrictions for active power output in accordance with Article 137(3) and

Connecting Europe Facility. Regulation Study for Interoperability in the Adoption of Autonomous Driving in European Urban Nodes:

IALA Guideline No The Reporting of Results of e-navigation Testbeds. Edition 1. December 2013

FRAUNHOFER INSTITUTE FOR CHEMICAL TECHNOLOGY ICT REDOX-FLOW BATTERY

Optimal and Modular Configuration of Wind Integrated Hybrid Power Plants for Off-Grid Systems

Modelling and monitoring Dutch highway traffic noise production

TDG-F-113 CEC New Test Development Proposal for a New Engine Fuels Test Procedure

Testing with Virtual Prototype Vehicles on the Test Bench

Relevance of head injuries in side collisions in Germany Comparison with the analyses and proposals of the WG13

ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS. Development Management Department 1 of 49

Transcription:

Wärme, Energie, Feuchte, Schall, Tageslicht Energetic evaluation of sun blind and sun protection equipment as thermal enclosure of transparent components - quantification of the effect and normative evaluation Summary of the project SWD-10.08.18.7-15.14 15 th November 2017 Project duration June 2015 to December 2017 Edited by Ingenieurbüro Prof. Dr. Hauser GmbH Leipziger Straße 184 34125 Kassel

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 2 The research project was funded by the research initiative Zukunft Bau of the Federal Institute for Research on Building, Urban Affairs and Spatial Development (Bundesinstitut für Bau-, Stadt- und Raumforschung BBSR, file reference: SWD-10.08.18.7-15.14). The responsibility for the content of the report lies with the author. Project Management: Ingenieurbüro Prof.-Dr. Hauser GmbH Dr.-Ing. Stephan Schlitzberger Leipziger Straße 184 34125 Kassel Telefon +49 (0) 561 / 94990432 Fax +49 (0) 561 / 494935 Mail schlitzberger@ibh-hauser.de Internet www.ibh-hauser.de Project Editing: o Dipl.-Ing. Christoph Kempkes Mail: c.kempkes@ibh-hauser.de Tel: 0561/94990436 o Dipl.-Ing. Barbara Falkenhof Mail: falkenhof@ibh-hauser.de Tel: 0561/94990435 o Dipl.-Ing. Christiane Schwenk Mail: schwenk@ibh-hauser.de Tel: 0561/94990434 Kassel, 15 th November 2017 Dr. Stephan Schlitzberger

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 3 Content 1 Abstract... 4 2 Project execution... 4 3 Summary and Outlook... 5 3.1 Results of the research... 5 3.2 Perspective and further research needs... 6 Inhalt

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 4 1 Abstract In the project, windows and facades as (partly transparent components) in the entire system with the shutter/sunblind are subjected to a comprehensive analysis regarding their effect on the energy demand of buildings against the background of current normative and legal provisions on the one hand and the systems currently available on the market on the other hand. The project is mathematically / theoretically related to the entire range of possible design variants (internal, external, and between the glasses), metrologically, the focus is on internal systems, because this currently identified a clear deficit in the area of normative regulations. On the basis of the mathematical / metrological investigations suggestions for a consistent consideration of thermal influence in the computational determination of the useful heat demand of buildings (energy consulting / proofing methods based on DIN V 18599) and basics for the manufacturer's provision of the required product characteristics are developed. The following fields of action represent the scope of the topics covered in the research work. 1. Thermal assessment of internal shutters/blinds on the basis of metrological parameter studies 2. Development of recommendations for an extension of normative bases for metrological / mathematical product labeling 3. Computational parameter variation for the quantification of the energy demand of buildings considering thermal influence of shutters and blinds on an hourly basis (dynamic simulation) 4. Development of proposals for consideration of thermally relevant shutters in the monthly energy demand calculation according to DIN V 18599 Within the framework of the research work, the already existing annual balance sheet procedure for the consideration of thermal contracts is extended to a monthly methodology and modified so that a suitable possibility for computational consideration arises in the framework of DIN V 18599. As a result of the project, a complete calculation specification for integration into DIN V 18599 is provided for the calculation of the annual useful heat demand. 2 Project execution The research work will be carried out within the scope of the research initiative "Zukunft Bau" after the application form of 13.10.2014 in accordance with the notification of approval of 22.6.2015 as well as after topping-up request 10.5.2016 and grant notification of the top-up from 15.6.2016. The processing period extends from June 2015 to December 2017. The project management and coordination is carried out by Ingenieurbüro Prof. Dr. Hauser GmbH. The content of the work is carried out with the inclusion of the two participating research institutions ift gemeinnützige Forschungs- und Entwicklungsgesellschaft mbh (ift Rosenheim) and Fraunhofer-Institut für Bauphysik (Fraunhofer IBP). The co-financing was carried out by Hunter Douglas Components Zweigniederlassung der Hunter Douglas GmbH and Verband innenliegender Sicht- und Sonnenschutz (ViS).

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 5 3 Summary and Outlook 3.1 Results of the research In the course of carrying out the metrological investigations, it has been found that the influence of the ventilation between an internal closure and a window with regard to the thermal effect is of greater importance than originally assumed. As part of a project increase, therefore, a targeted additional investigation and evaluation of the influence of the ventilation was carried out. Only through this additional investigation it was possible to purposefully process the formulated project goals. The first significant result of the project was the development of a calculation rule for incorporating appropriate calculation rules in the DIN V 18599 series of standards. The results were submitted to the relevant standards committee and transferred to the edition of DIN V 18599-2: 2016-10. An important basis has thus been created for inclusion in statutory or regulations of technically ordinance (Energy Savings Regulation EnEV, Building Energy Act GEG) for the energetic verification. In addition to the public-law significance of the extension of DIN V 18599-2 for the evaluation of the effect of a temporary thermal insulation but also an important tool for the evaluation in the course of an energy consultation. In addition to the mathematical analysis of the temporary thermal protection and the quantification of the energetic effect, a detailed metrological investigation of internal sun blinds and sun protection systems was carried out during the project. On the one hand, the determination of specific characteristic values for the additional thermal resistance R for real closures was carried out. In addition, measurements were carried out on idealized terminations (sheet metal and insulating board) and from this calculation rules were derived for the treatment of the partial resistances of the termination (R sh) contained in a R value and the air layer (R air) between the termination and the window or window glass. Depending on the effective total joint width e tot as a parameter for the air permeability of the connection situation, a proposal emerges from this investigation, as based on a Hotbox measurement of a window with completion in the taped state (lower, upper and lateral connections of the conclusion soffit or wall sealed by adhesive tape) characteristic values for the additional heat transfer resistance at different air permeabilities of the connection situation can be derived. The proposed procedure here is a combination of a metrological examination and a mathematical consideration of the resistance of the (in the taped state dormant) air layer between closure and window according to DIN EN ISO 6946. The main advantage of the proposed approach is compared to the measurement of a real situation therein, that R values for different air permeabilities of the connection situation can be derived from just one measurement. If the measurement is made for a real installation situation, the metrologically determined R value must be considered as installation-specific value, which also applies only to the gap dimensions existing during the measurement in the Hotbox. In this context, it should be emphasized that a R value determined in a conventional manner (that is, in a nontaped state) does not have to be understood as a characteristic value for a particular sun blind or sun protection system, but as "only" a specific characteristic for a specific real installation. The proposed procedure for determining R values by combination of measurement and calculation can thus ensure a much wider usability of the measurement results. In addition, the procedure ensures that no influence of the ventilation is mapped in a metrologically determined R value. This improves the comparability of measurements performed in different test facilities. Comparative measurements carried out in the test laboratories of ift Rosenheim and the Fraunhofer Institute for Building Physics in Stuttgart show that comparability of measurement results for real connection situations is virtually impossible, as even slight deviations in the gap dimensions lead to high deviations in the measured R values.

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 6 Table 1: Based on the metrological investigations on real and idealized closures in the taped and nontaped state as well as on the developed factorial correction regulations, tabularized reference values for typical inner closures were derived as another important project result, which are reproduced in the following table. Proposed values for the thermal resistance of terminations R sh and additional heat transmission resistances R as a function of air permeability for typical external and internal shutters. Characteristics of the outer shutters according to DIN EN ISO 10077-1: 2010-05 or DIN EN 13125: 2001-10 Typischer Wärmedurchlasswiderstand des Abschlusses Zusätzlicher Wärmedurchlasswiderstand bei einer bestimmten Luftdurchlässigkeit der Abschlüsse Art des Abschlusses R sh R (m²k)/w (m²k)/w Luftduchlässigkeit sehr hoch hoch duchschnittl. niedrig luftdicht äußere Abschlüsse Rollläden aus Aluminium 0,01 0,08 0,09 0,12 0,15 0,18 Rollläden aus Holz oder Kunststoff ohne Dämmstoffeinlage 0,10 0,08 0,12 0,17 0,22 0,27 Rollläden aus Kunststoff mit Dämmstoffeinlage 0,15 0,08 0,13 0,19 0,26 0,31 Abschlüsse aus Holz, 25 mm bis 30 mm dick 0,20 0,08 0,14 0,22 0,30 0,36 innere Abschlüsse - Montage zwischen den Glasleisten Plissee/Faltstore/Rollo 0,01 0,03 0,05 0,07 0,10 0,13 Einkammer-Wabenplissee 0,08 0,03 0,06 0,09 0,13 0,19 Doppelkammer-Wabenplissee 0,22 0,04 0,07 0,12 0,19 0,30 innere Abschlüsse - Montage in der Laibung Plissee/Faltstore/Rollo 0,01 0,04 0,06 0,09 0,13 0,17 Einkammer-Wabenplissee 0,08 0,04 0,07 0,11 0,16 0,23 Doppelkammer-Wabenplissee 0,22 0,05 0,09 0,15 0,23 0,35 innere Abschlüsse - Montage vor der Nische Plissee/Faltstore/Rollo 0,01 0,03 0,06 0,11 0,14 0,17 Einkammer-Wabenplissee 0,08 0,03 0,07 0,12 0,16 0,21 Doppelkammer-Wabenplissee 0,22 0,04 0,09 0,15 0,20 0,29 The results of the project work are an important contribution to the possibility of energetically accounting for the temporary heat protection effect of internal and external shutters. In particular, tabulated key figures for internal shutters are now available that correspond to the current range of effects of typical systems. Compared to the previous normative recording also a significant improvement is created by the fact that now the quantification of the effect of a temporary heat protection in the balance sheet of DIN V 18599, as perspective exclusive calculation method for energetic assessment according to building energy law (GEG) or energy saving regulation (EnEV), is possible. 3.2 Perspective and further research needs On the basis of the possibilities created by the project processing for mathematical consideration of a temporary thermal protection, the results and the potential savings quantified for different starting situations should provide a basis for discussion regarding the admissibility of a mathematical approach in the course of the energetic proofing methods according to the GEG or EnEV. This concerns the fundamental question as to whether and under which conditions a theoretically calculated theoretically available savings potential can be practically achieved. At least for such situations, where "activation" is automated by a regulation or control, the legislator should allow the approach as benefit of the automation that ensures the savings potential. Especially in the context of the discussions on flexibilization regarding the fulfillment of ambitious requirement levels, the automatization is becoming increasingly obvious in the course of smart home development and the associated saving potentials should be honored. Further research needs can be deduced from the metrological investigations insofar as the approaches developed for the factorial correction of the partial resistances R sh of a closure and R air of the air layer between closure and window or window glass are examined and confirmed by further examinations and if necessary, they should also be corrected. In particular for the evaluation of the mounting situation "between the glazing beads" proposed adaptation of the

Summary SWD-10.08.18.7-15.14 v. 15.11.2017 Page 7 factors derived for the assembly situation "in the soffit" factors a metrological confirmation is desirable. Fundamentally, there is a need for further investigation with regard to a review of the regulations "adopted" from DIN EN 13125 on the dependence of the R value on the effective total joint width e tot. For the mounting situation "in front of the niche", there has hitherto been no normative specification, as in this case an effective overall joint width is to be determined. This against the background that here, as in the provided in DIN EN 13125 upper, lower and lateral distances can be specified within the soffit, but the (average) horizontal distance of the conclusion to the wall represents the actual measurable size. There is also a normative need for updating with regard to the formulation of uniform specifications for carrying out hot box measurements on windows with shutters. On the basis of the current regulations in this regard, no comparability of measurements or reproducibility of measurement results can be guaranteed. This particularly concerns the need for specifying geometrical constraints for trial performance that differentiate between measurements for outer and inner shutters. For the continuation of the normative regulations, the proposal developed in the framework of the research work to make measurements on windows with taped shutters can be a starting point, since the influence of a ventilation behind the shutters has a great influence on the heat transfer to be measured and this uncertainty can be circumvented by taping the gaps which allows a better reproducibility of measurement results.