RFOU 0.6/1kV Power Cable

Similar documents
BFOU 0.6/1kV Power Cable

N2XY IEC XLPE PVC 0.6/1kV Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable

SY PVC / BS EN Control Flexible Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

6491B / H07Z-R / BS EN Cable

AAAC - ASTM - B All Aluminium Alloy Conductor

TRATOS OIL&GAS NEK606

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

BS 6724 Armoured Power Cables, 600/1000V

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Technical attributes

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Technical Data Sheet Shielded (CY) PVC Control Cable

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Technical Data Sheet Unshielded (YY) PVC Control Cable

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Technical Data Sheet Shielded (CY) PVC Control Cable

Unarmoured Single-Core Cables to BS6883

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ACSR - ASTM - B Aluminium Conductor Steel Reinforced

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Technical Data Sheet Unshielded (YY) PVC Control Cable

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Cables for Railway Technology

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

14 HH EAC/CTP CE RoHS-II conform

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Technical Data Sheet Shielded (CY) PVC Control Cable

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Data sheet chainflex CF881

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

ÖLFLEX CLASSIC 110 CY

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

Data sheet chainflex CF270.UL.D

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Data sheet chainflex CF886

o o blue-brown Fire Performance BS EN BS EN

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Data sheet chainflex CF8821

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

Power & Control Cable IEC

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Data sheet chainflex CFSOFT1

Power & Control Cable IEC

ÖLFLEX CLASSIC 115 CY

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

INFORMATION. Hybrid cables. Description

Global data. Electrical parameters

BlueLine Cables for Shipbuilding

Data sheet chainflex CF886

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

ÖLFLEX CLASSIC 110 H Info Benefits

Power & Control Cable IEC

Data sheet chainflex CF240

CF270.UL.D.

The cables you need when you need them

Data sheet chainflex CF140.UL

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

Data sheet chainflex CF210.UL

Caledonian Flame Retardant RS485 Databus Cables

DNV-GL HH CE RoHS-II conform

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

CRANE, CONVEYOR, LIFT & REELING CABLES

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

SAC-4P-M12MS/ 5,0-PUR SH

HIGH TEMPERATURE CABLES

ZHPCG CK0226 POWER CABLE WIRE & CABLE

Data sheet chainflex CF885.PE

Data sheet chainflex CF6

Transcription:

RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment such as muddy, dry, wet and oily conditions meeting the requirements of NEK 606. CABLE STANDARDS NEK 606 P1/P8, IEC 60092/353, IEC 60092/350-351-359, BS EN/IEC 6754/1 and 2, BS EN/IEC 61034/1 and 2, DIN EN 50268/1 and 2, BS EN 60288 CONSTRUCTION Conductor Class 2 stranded tinned copper conductor Insulation Halogen free EPR (Ethylene Propylene Rubber) Bedding Halogen free compound Screen TCWB (Tinned Copper Wire Braid) Sheath SHF, MUD (halogen free, mud resistant) Note Class 5 flexible conductors available on request The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Eland Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed. CHARACTERISTICS Voltage Rating (Uo/U) 600/1000V Test Voltage 3.5kV Operating Temperature -40 C to +90 C Minimum Bending Radius 8 x overall diameter Sheath Black technicalspecification 1 of 5

DIMENSIONS ELAND PART NO. NO. OF CORES NOMINAL CROSS NOMINAL OVERALL DIAMETER mm NOMINAL WEIGHT kg/km ASHNR01015 1 1.5 8.7 140 ASHNR01025 1 2.5 9.2 160 ASHNR01040 1 4 9.8 170 ASHNR01060 1 6 10.4 220 ASHNR0110 1 10 11.4 280 ASHNR0116 1 16 12.5 360 ASHNR0125 1 25 14.8 480 ASHNR0135 1 35 16 630 ASHNR0150 1 50 17.6 840 ASHNR0170 1 70 19.6 1070 ASHNR0195 1 95 21.9 1300 ASHNR01120 1 120 23.9 1700 ASHNR01150 1 150 25.9 2020 ASHNR01185 1 185 28.3 2350 ASHNR01240 1 240 31.1 3120 ASHNR01300 1 300 34.4 3750 ASHNR02015 2 1.5 12.6 250 ASHNR02025 2 2.5 14 330 ASHNR02040 2 4 15.2 400 ASHNR02060 2 6 16.3 470 ASHNR0210 2 10 18.4 630 ASHNR0216 2 16 20.5 820 ASHNR0225 2 25 24.3 1200 ASHNR0235 2 35 26.8 1500 ASHNR0250 2 50 29.9 1840 ASHNR03015 3 1.5 13.2 280 ASHNR03025 3 2.5 14.7 380 ASHNR03040 3 4 16 460 ASHNR03060 3 6 17.2 550 ASHNR0310 3 10 19.4 750 ASHNR0316 3 16 21.7 1000 ASHNR0325 3 25 25.9 1490 ASHNR0335 3 35 28.5 1870 ASHNR0350 3 50 31.8 2430 ASHNR0370 3 70 37 3320 ASHNR0395 3 95 41.9 4340 ASHNR03120 3 120 46.7 5490 ASHNR03150 3 150 51.2 6630 ASHNR03185 3 185 56.7 8080 ASHNR03240 3 240 62.8 10130 ASHNR04015 4 1.5 14.7 360 ASHNR04025 4 2.5 15.8 440 ASHNR04040 4 4 17.3 550 ASHNR04060 4 6 18.6 660 ASHNR0410 4 10 21.1 910 ASHNR0416 4 16 23.7 1230 ASHNR0425 4 25 28.3 1840 ASHNR0435 4 35 31.3 2230 2 of 5 technicalspecification

ELAND PART NO. NO. OF CORES NOMINAL CROSS NOMINAL OVERALL DIAMETER mm NOMINAL WEIGHT kg/km ASHNR0425 4 50 35.9 3090 ASHNR0470 4 70 40.7 4330 ASHNR0495 4 95 46.7 5810 ASHNR04120 4 120 51.5 7030 ASHNR04150 4 150 57 8610 ASHNR04185 4 185 62.6 10570 ASHNR05015 5 1.5 15.8 420 ASHNR05025 5 2.5 17.1 510 ASHNR05040 5 4 18.6 640 ASHNR05060 5 6 20.1 810 ASHNR0510 5 10 22.9 1110 ASHNR0516 5 16 25.8 1470 ASHNR0525 5 25 31 2240 ASHNR0535 5 35 34.7 2820 ASHNR0550 5 50 39.3 3980 ASHNR0570 5 70 45.2 5270 ASHNR0595 5 95 51.3 7570 ASHNR07015 7 1.5 16.9 490 ASHNR07025 7 2.5 18.4 610 ASHNR10015 10 1.5 20 680 ASHNR10025 10 2.5 21.9 940 ASHNR12015 12 1.5 21.4 780 ASHNR12025 12 2.5 23.4 980 ASHNR14015 14 1.5 22.4 930 ASHNR14025 14 2.5 24.5 1090 ASHNR19015 19 1.5 24.7 1050 ASHNR19025 19 2.5 27.1 1420 ASHNR24015 24 1.5 27.4 1310 ASHNR24025 24 2.5 30.2 1830 ASHNR27015 27 1.5 29.1 1570 ASHNR27025 27 2.5 32.1 1990 ASHNR37015 37 1.5 32.9 1820 ASHNR37025 37 2.5 36.7 2600 technicalspecification 3 of 5

CONDUCTORS NOMINAL CROSS MAXIMUM DC RESISTANCE OF CONDUCTOR AT 20 C ohms/km Class 2 Class 5 0.5 36.7 40.1 0.75 24.8 26.7 1 18.2 20 1.5 12.2 13.7 2.5 7.56 8.21 4 4.7 5.09 6 3.11 3.39 10 1.84 1.95 16 1.16 1.24 25 0.734 0.795 35 0.529 0.565 50 0.391 0.393 70 0.27 0.277 95 0.195 0.210 120 0.154 0.164 150 0.126 0.132 185 0.1 0.108 240 0.0762 0.0817 300 0.0607 0.0654 ELECTRICAL CHARACTERISTICS Current Carrying Capacity NOMINAL CROSS 1 CORE 2 CORE 3 AND 4 CORE 5 CORE Conductor Temperature: 90 C Ambiant Temperature 45 C 1 18 15 13 11 1.5 23 20 16 13 2.5 30 26 21 18 4 40 34 28 23 6 52 44 36 30 10 72 61 50 42 16 96 82 67 56 25 127 108 89 74 35 157 133 110 92 50 196 167 137 115 70 242 206 169 142 95 293 249 205 171 120 339 288 237 198 150 389 331 273 227 185 444 377 311 260 240 522 444 366 305 300 601 511 420 351 400 719 611 503 420 500 827 703 579 484 630 955 812 669 558 4 of 5 technicalspecification

DE-RATING FACTORS NOMINAL CROSS NO. OF CORES 7 10 12 14 19 24 27 37 1 9 8 8 7 7 6 6 5 1.5 12 11 10 10 9 8 8 7 2.5 16 14 13 12 11 10 10 9 AMBIENT TEMPERATURE 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC 75ºC 80ºC DE-RATING FACTOR 1.1 1.05 1 0.94 0.88 0.82 0.74 0.67 0.58 0.47 The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances. technicalspecification 5 of 5