Hall Coded Non-contact Safety Switches. Model Number Structure

Similar documents
F3S-TGR-KM15/-KM16/-KH16

F3S-TGR-KHL1/-KHL3/-KHL3R

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

Hinged Safety Door Switch

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Sense7-series Non-contact coded safety switch

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Inductive Proximity Sensor

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Safety-door Switch. Ordering Information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Manual Reset Limit Switch

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Model Number Structure

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Model Number Structure

Switching Power Supply

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

CAUTION CM-SE CM-S21 CM-S41

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

MKey9-series Safety Interlock Switch with Guard Locking

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Model Number Structure

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Inductive Proximity Sensor

Switching Power Supply

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

Subminiature Basic Switch

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

SG-B1 SERIES / SG-A1 SERIES

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Ordering Information. Text PCB Power Relay G5LE

Model Number Structure

Tactile Switch (Hinged Type)

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

2NC (slow-action) Direct. Model. opening

IDEM Solenoid Interlock Safety Switches

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

EStrong-series Emergency Stop

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

2-Color Display High-Precision Digital Pressure Switch

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

Solid State Relays G3NA. Model Number Structure. Model Number Legend

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Cylindrical Proximity Sensor

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

HS1L Interlock Switches with Solenoid

E2EZ-X2D1-N E2EZ-X2D2-N

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

HS7A-DMC Non-contact Interlock Switches

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety switches with solenoid and separate actuator

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

HS1E Series Full Size Interlock Switch with Locking Solenoid

Transcription:

Hall Coded Non-contact Safety Switches FS-TGR-N@C Hall coded non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available. Based on hall technology Connect up to 20 switches in series LED supports easy diagnosis Operates with all OMRON safety controllers Operates behind stainless steel fittings Non-contact no abrasion no particles Compensation of mechanical tolerances Suitable for high pressure cleaning, CIP/SIP processes due IP69K (pre-wi types) Conforms to safety categories up PLe acc. EN ISO1849-1 Model Number Structure FS-TGR-N@@C-21-@@ 12 1. Type L: Elongated Sensor S: Small Sensor M: Miniature Sensor B: Barell Sensor 2. Housing Material P: Plastic Housing M: Stainless Steel Housing H: Hygienic designed Stainless Steel Housing F: Special Food Type Stainless Steel Housing. Cable Length/connection 05: 5 m Cable 05-R*: 5 m Cable exit to the right 10: 10 m Cable 10-R*: 10 m Cable, exit to the right M1J8: M12 male connector, 8 pin, fitted with 250 mm cable M1J8-R*: M12 male connector, 8 pin, fitted with 250 mm cable exit to the right * only for FS-TGR-NMPC and FS-TGR-NMHC 1

Ordering Information FS-TGR-N@C Polyester Housing Type Cable connection Contact configuration Order code Elongated Sensors 5 m pre-wi FS-TGR-NLPC-21-05 10 m pre-wi FS-TGR-NLPC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NLPC-21-M1J8 Small Sensors 5 m pre-wi FS-TGR-NSPC-21-05 10 m pre-wi FS-TGR-NSPC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NSPC-21-M1J8 Miniature Sensors 5m pre-wi FS-TGR-NMPC-21-05 2NC/1NO 10 m pre-wi FS-TGR-NMPC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NMPC-21-M1J8 5 m pre-wi, cable exit right FS-TGR-NMPC-21-05-R 10 m pre-wi, cable exit right FS-TGR-NMPC-21-10-R M12, 8 pin, fitted with 250 mm cable exit right FS-TGR-NMPC-21-M1J8-R Barrel Sensors 5 m pre-wi FS-TGR-NBPC-21-05 10 m pre-wi FS-TGR-NBPC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NBPC-21-M1J8 Stainless steel housing Type Cable connection Contact configuration Order code Elongated Sensors 5 m pre-wi FS-TGR-NLMC-21-05 10 m pre-wi FS-TGR-NLMC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NLMC-21-M1J8 Small Sensors 5 m pre-wi FS-TGR-NSMC-21-05 10 m pre-wi 2NC/1NO FS-TGR-NSMC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NSMC-21-M1J8 Barrel Sensors 5 m pre-wi FS-TGR-NBMC-21-05 10 m pre-wi FS-TGR-NBMC-21-10 Hygienic and food types M12, 8 pin, fitted with 250 mm cable FS-TGR-NBMC-21-M1J8 Type Cable connection Contact configuration Order code Small Sensors 5 m pre-wi FS-TGR-NSHC-21-05 10 m pre-wi FS-TGR-NSHC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NSHC-21-M1J8 Small Sensors (Special food types) 5m pre-wi FS-TGR-NSFC-21-05 10 m pre-wi FS-TGR-NSFC-21-10 M12, 8 pin, fitted with 250 mm cable 2NC/1NO FS-TGR-NSFC-21-M1J8 Miniature Sensors 5m pre-wi FS-TGR-NMHC-21-05 10 m pre-wi FS-TGR-NMHC-21-10 M12, 8 pin, fitted with 250 mm cable FS-TGR-NMHC-21-M1J8 5 m pre-wi, cable exit right FS-TGR-NMHC-21-05-R 10 m pre-wi, cable exit right FS-TGR-NMHC-21-10-R M12, 8 pin, fitted with 250 mm cable exit right FS-TGR-NMHC-21-M1J8-R 2

FS-TGR-N@C Accessories Cables 8-pin T-connector connection cable Actuators Mounting screws Order code 2m Y92E-M12PURSH8S2M-L 5m Y92E-M12PURSH8S5M-L 10 m Y92E-M12PURSH8S10M-L 25 m Y92E-M12PURSH8S25M-L M12 T-connector for M12 connector - types F9-TGR-NT 0.6 m, M12-8pin Y92E-M12FSM12MSPURSH806M-L 2 m, M12-8pin Y92E-M12FSM12MSPURSH82M-L 5 m, M12-8pin Y92E-M12FSM12MSPURSH85M-L 10 m, M12-8pin Y92E-M12FSM12MSPURSH810M-L for FS-TGR-NLPC F9-TGR-NLPC-A for FS-TGR-NSPC F9-TGR-NSPC-A for FS-TGR-NMPC F9-TGR-NMPC-A for FS-TGR-NCPC F9-TGR-NCPC-A for FS-TGR-NWPC F9-TGR-NWPC-A for FS-TGR-NBPC F9-TGR-NBPC-A for FS-TGR-NLMC F9-TGR-NLMC-A for FS-TGR-NSMC F9-TGR-NSMC-A for FS-TGR-NBMC F9-TGR-NBMC-A for FS-TGR-NSHC F9-TGR-NSHC-A for FS-TGR-NSFC F9-TGR-NSFC-A for FS-TGR-NMHC F9-TGR-NMHC-A Set of Torx safety screws (M4, 4 0 mm, 4 20 mm, 4 10 mm; incl. F9-TGR-N-SCREWS washers and Torx bit)

FS-TGR-N@C Control units G9SA Order code G9SA-01 G9SA-501 G9SA-21-T075 G9SA-21-T15 G9SA-21-T0 Safety relay units G9SB G9SX G9SB-2002-C G9SB-2002-A G9SB-200-B G9SB-200-D G9SB-012-A G9SB-01-B G9SB-012-C G9SB-01-D G9SX-BC202-R_ G9SX-AD-T15-R_ G9SX-AD-T150-R_ G9SX-ADA2-T15-R_ G9SX-ADA2-T150-R_ G9SP-N Programmable standalone controllers G9SP-N10S G9SP-N10D G9SP-N20S NE1A Programmable network controllers NE1A-SCPU01-V1 4

FS-TGR-N@C Specifications Mechanical data Plastic housing Indicator LED Operating distance OFF ON (Sao) 8 mm: NMPC, NBPC 10 mm: NLPC, NSPC ON OFF (Sar) 12 mm: NMPC, NBPC 20 mm: NLPC, NSPC Recommended setting gap 5mm Actuator approach speed Min. 4 mm/s Max. 1,000 mm/s Electrical data Stainless steel housing 8 mm: NMHC, NBMC 10 mm: NLMC, NSMC, NSHC, NSFC 12 mm: NMHC, NBMC 20 mm: NLMC, NSMC, NSHC, NSFC Switching frequency Max. 1Hz Operating temperature 25 to 80 C 25 to 105 C Enclosure protection Flying lead IP69K M12 connector IP67 Cable material Flying lead PVC, 8 core, Ø 6 mm o.d. M12 connector 250 mm, PVC, Ø 6 mm o.d. Mounting bolts 2 M4 Tightening torque for mounting bolts Max. 1 Nm Shock resistance (IEC 68-2-27) 11 ms, 0 g Vibration resistance (IEC 68-2-6) 10 to 55 Hz, 1 mm Material Black polyester Stainless steel 16 Plastic housing Sensor technology Hall Serial switching up to 20 pcs. in series Power supply 24 VDC ±10% Rated loads NC contacts Max. 0.2 A @ 24 VDC NO contact Max. 0.2 A @ 24 VDC Dielectric withstand 250 VAC Insulation resistance 100 M Switching current Min. 1 ma, 10 VDC Stainless steel housing Reliability data Plastic housing Stainless steel housing EN ISO 1849-1 up to PLe depending upon system architecture EN 62061 up to SIL depending upon system architecture PFHd 2.52 10-8 Proof test interval (Life) 47 years MTTFd (@ nop: 8 cycles per hour) 470 years Approved standards EN standards certified by TÜV Rheinland EN ISO1849-1 EN 60204-1 EN ISO 14119 EN/IEC 60947-5- UL 508, CSA C.2 BS 504 EN 1088 conformance 5

FS-TGR-N@C Operating characteristics L -5-4 - -2-1 0 1 2 4 5 5 mm misalignment tolerance after setting Connection diagram Cable version Pin No. Signal name +24 VDC GND NC Channel 1/+ NC Channel 1/ NC Channel 2/+ NC Channel 2/ Aux. NO Channel/+ Aux. NO Channel/ M1J8-Connector version (M12 male) Pin No. (male side) 6 7 1 5 8 4 2 2 7 1 4 6 5 8 Signal +24 VDC GND NC Channel 1/+ NC Channel 1/ NC Channel 2/+ NC Channel 2/ Aux. NO Channel/+ Aux. NO Channel/ Wire Y92E-M12PURSH8S_M-L pink grey Note: If the auxiliary circuit is not fitted or not used then cut and discard the / or /pink conductors. 6

FS-TGR-N@C Dimensions Elongated Sensor (Sensor/Actuator) FS-TGR-NLPC 88 88 78 78 4.50.50 25 25 18.50 7 Ø 5.20 1 1 FS-TGR-NLMC 88 88 78 78 4.60.50 25 25 18.50 7 Ø 5.40 14 14 Small Sensor (Sensor/Actuator) FS-TGR-NSPC 50 1 1 4.50 4.50 20.50 20.50 4.20 4.20 50 FS-TGR-NSMC 50 1 1 4.50 4.50 21 20.5 4.20 4.20 50 FS-TGR-NSHC 50 1 1 20.50 20.50 Ø5 50 7

FS-TGR-N@C FS-TGR-NSFC 50 1 1 10 10 20.50 20.50 M4 10 mm Tapped hole 50 Miniature Sensor (Sensor/Actuator, left side version) FS-TGR-NMPC 5 6 6 26 19 Ø 8.40 1 6 26 19 Ø 8.40 1 6 Ø 4.50 Ø 4.50 FS-TGR-NMHC 6 9 9 15 26 26 19 15 19 Ø 4.40 Ø 4.40 Barrel Sensor (Sensor/Actuator) FS-TGR-NBPC FS-TGR-NBMC 8

Wiring examples (Single head connection up to category 4 acc. EN954-1) FS-TGR-N@C G9SB Single Sensor Application with G9SB-2002-C (up to Safety PLe acc. EN ISO 1849-1) +24 V GND Start FS-TGR-N_C Actuator Sensor A1 A2 T1 G9SB-2002-C T11 T2 T12 T T21 Feedbackloop 1 14 2 24 +Us GND M Series connection Application, up to 20 Sensors with G9SB-2002-C (up to Safety PLd acc. EN ISO 1849-1) FS-TGR-N_C +24 V GND Actuator Sensor A1 A2 T1 G9SB-2002-C Start Feedbackloop T11 T12 T T21 1 14 T2 2 24 +Us GND M 9

FS-TGR-N@C G9SA Single Sensor Application with G9SA-01 (up to Safety PLe acc. EN ISO 1849-1) +24 V GND Start FS-TGR-N_C Actuator Sensor A1 A2 T1 G9SA-01 T11 T2 T12 T T21 Feedbackloop 1 14 4 +Us M GND Series connection Application, up to 20 Sensors with G9SA-01 (up to Safety PLd acc. EN ISO 1849-1) FS-TGR-N_C +24 V GND Actuator Sensor A1 A2 T1 G9SA-01 Start Feedbackloop T11 T12 T T21 1 14 T2 4 +Us GND M 10

FS-TGR-N@C G9SP Single Sensor Application with G9SP (up to Safety PLe acc. EN ISO 1849-1) +24 V GND Actuator FS-TGR-N_C Sensor V0 Test 0 In 0 Test 1 In 1 G9SP G0 Series connection Application, up to 20 Sensors with G9SP (up to Safety PLd acc. EN ISO 1849-1) Actuator FS-TGR-N_C Sensor +24 V GND V0 Test 0 In 0 Test 1 In 1 G9SP G0 11

T-Connector and Connection Cable Series connection with 2 or Sensors for example with G9SA-01 (up to Safety PLd acc. EN ISO 1849-1) FS-TGR-N_C-M1J8 Actuator Sensor +24 V GND FS-TGR-N@C Start Y92E-M12FSM12MSPURSH8_M-L Length: 0.6 m, 2 m, 5 m or 10 m A1 A2 T1 G9SA-01 Feedbackloop F9-TGR-NT pink T11 T12 T T21 T2 Y92E-M12FSM12MSPURSH8_M-L Length: 0.6 m, 2 m, 5 m or 10 m 1 14 4 F9-TGR-NT +Us GND M Y92E-M12PURSH8S_M-L Lenght: 2 m, 5 m, 10 m or 25 m 12

Safety Precautions!WARNING Be sure to turn OFF the power before performing wiring. Do not touch charge parts (e.g., terminals) while power is ON. Doing so may result in electric shock. Do not allow the actuator to come close to the switch with the door open. Doing so may cause machinery to start operating and may result in injury. Guard Stops FS-TGR-N@C Use guard stops in the way shown below to ensure that the switch and actuator do not make contact when the guard door is closed. Guard door!caution Guard Stops Keep actuators (magnets) away from magnetically sensitive equipment like PC harddisks, floppy disks etc. The magnetic field of the magnet will damage existing data. Switch Actuator Application Precautions Do not use the product in locations subject to explosive or flammable gases. Do not use load currents exceeding the rated value. Be sure to wire each conductor correctly. Be sure to confirm correct operation after completing mounting and adjustment. Do not drop or attempt to disassemble the product. Be sure to use the correct combination of switch and actuator. Use a power supply of the specified voltage. Do not use power supplies with large ripples or power supplies that intermittently generate incorrect voltages. Capacitors are consumable and require regular maintenance and inspection. Mounting Direction min. 2 mm min. 5 mm (Standard Sensor) max. 4 mm (Elongated Sensor) Installation Locations Do not install the product in the following locations. Doing so may result in product failure or malfunction. Locations subject to direct sunlight Locations subject to humidity levels outside the range 5% to 85% or subject to condensation due to extreme temperature changes Locations subject to corrosive or flammable gases Locations subject to shocks or vibration in excess of the product ratings Locations subject to dust (including iron dust) or salts Take appropiate and sufficient countermeasures when using the product in the following locations. Locations subject to static electricity or other forms of noise Locations subject to possible exposure to radioactivity Locations subject to power supply lines It is advisable to mount the switches on non ferrous materials. The presence of ferrous material can effect switching sensitivity. Solvents Ensure that solvents, such as alcohol, thinner, trichloroethane, or gasoline do not adhere to the product. Solvents may cause markings to fade and components to deteriorate. CORRECT Using for Hinged Doors On hinged doors, install the Sensor at an opening edge as shown below. CORRECT CORRECT Mutual Interference CORRECT INCORRECT INCORRECT If the switch and actuator are mounted in parallel, be sure to separate them by at least 25 mm, as shown below. Switch Actuator 25 mm min. Switch Actuator Guard door 1

FS-TGR-N@C ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.0527. Cat. No. E14E-EN-06 In the interest of product improvement, specifications are subject to change without notice. 14