INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Similar documents
MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

INSTALLATION INSTRUCTION Bollard Light 12V

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Captivate Illuminated Mirror Light

Spun Bay Installation Standard Version (non dimmable), Hook Mount

Wet Rated Batten LED Luminaire

EMERY SKY SUSPENDED LED LUMINAIRE

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

GETTING STARTED WITH IN-WALL DIMMER SWITCH

MAXLITE RKT LED Retrofit Kit

Specification Grade Contemporary Wall Mount/Technical Installation Data

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

LAL SERIES LED LUMINAIRE

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTALLATION INSTRUCTION

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Customer service: or Upper mounting ring. Canopy

INSTALLATION INSTRUCTION

Installation Instructions

I. Pendant Mount Installation

HP-2 / HP-6 Direct Installation Instructions Overview

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Installation Instructions CRAFT M/L

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

Installation Instructions

Lumination TM LED Luminaire (IS Series)

Installation Instructions

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

97Ti, 95Ti, 93T Treadmills Assembly Instructions

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

LST Solid-State Starter User s Manual TB WOOD S INCORPORATED

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

INSTALLATION GUIDE Works in double and single ended wiring.

Elle Surface Mounting Instructions

SAVE THESE INSTRUCTIONS

Horticulture Batten LED Luminaire

Elle Surface Mounting Instructions

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

ALL W INSTALLATION INSTRUCTIONS

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

INSTRUCTIONS. Power Panel. Installation Instructions

CLARA CLA SUSPENDED, WALL, SURFACE

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Cable Cubby 1202 and 1402 Installation Guide

Installation Instructions

Installation Instructions

Installation Instructions

SloanLED THINLED. Constant Current. Installation Guide

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

MOONRING 1 LP1/MR1 Suspended, Surface LED

CSD Series Current Devices Split Core

Installation Instructions Shaper 1800 aircraft cable installation

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Installation Instructions

M Remote Mounting Kit

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

Fan Relay Board (FRBii) Assembly

INSTALLATION INSTRUCTION Magnetic Transformer

Cable Cubby 650 UT Installation Guide

ALL200RM/ALL200RM-CM

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING

Installation Instructions

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

ALL700RM-230V INSTALLATION INSTRUCTIONS

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

poollux Power plx-pw60 & plx-pw100

ASSEMBLY AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL OM F

MODELS. 2 & 4 Low Profile Linears

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

M Remote Mounting Kit

Transcription:

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com

Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Only install with a compatible Class 2 LED Driver. This product has not been evaluated for use when connected to an LED driver that does not comply with Class 2 voltage and energy limited supplies. 5. Do not install in wet locations. For dry and damp use only. 6. Turn off electrical power before installing or servicing fixture in any way. 7. To reduce the risk of fire and overheating, make sure all connections are tight. Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Installez uniquement avec un pilote de classe 2 compatible. Ce produit n a pas été évalué pour une utilisation lorsqu il est connecté à un pilote de LED qui n est pas conforme aux alimentations de tension et d énergie limitée de classe 2. 5. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 6. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 7. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. LP1/MR1 Installation Guide 2 of 12 102-000030 - IG011519-A.0

Table of Contents Luminaire Overview 4 Diagrams 4 Components 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Prepare Ceiling 5 Standard Suspension 5 Central Axis Suspension 7 Surface Mount (Back) 9 Connecting Multiple Sections 10 Wiring Diagrams 11 Troubleshooting 12 LP1/MR1 Installation Guide 3 of 12 102-000030 - IG011519-A.0

LUMINAIRE OVERVIEW CENTRAL AXIS SUSPENSION DIAGRAM STANDARD SUSPENSION DIAGRAM 4 J-Box Canopy Bracket Canopy Power Cord Cable Coupler Suspension Cables Cable Gripper Light Leak Band STANDARD SUSPENSION COMPONENTS Canopy Assembly Suspension Bullet Suspension Cable Ceiling Fitting Parts (by others) 4 Square/Octagonal J-Box Wood Screws, #10, 1.5 long Tools Required Drill #2 phillips bit Wire strippers 1/16 Hex Key (for Ceiling) 5/64 Hex Key (for Joining) Quick Specs Input Voltage / Frequency: See product label Rated Power: See product drawing Ambient Temperature: -4 120 F (-20 50 C) Environment: Dry and damp locations LP1/MR1 Installation Guide 4 of 12 102-000030 - IG011519-A.0

C L C L Installation: Prepare Ceiling Installation: Standard Suspension A LIGHTING DIRECTION SAMPLE DRAWING 1 See Final/Record Drawings for Mounting Locations See final/record drawings for mounting locations. Install framing or 1/4-20 ceiling rods with consideration for alignment of wiring and mounting locations. 4A Install Ceiling Fitting - Framing Ceiling Fittings may be installed directly into framing with appropriate hardware. A ELECTRICAL WIRING: T MUST SAMPLE DRAWING 2 Install Canopy J-Box Install 4 square/octagonal Canopy J-Box (sold separately) at power feed location per final/record drawing. 4B Install Ceiling Fitting - Toggle Bolts Ceiling Fittings may also be mounted using toggle bolts. ELECTRICAL WIRING: MUST 3 Install Remote Driver J-Box Install remote driver J-Box(es) in an accessible/ serviceable location. Connect to building power, and run low voltage wire from Remote Driver J-Box to Canopy J-Box in accordance with local/state/federal regulations. 4C Install Ceiling Fitting - 1/4-20 Threaded Rods Ceiling Fittings may also be mounted on 1/4-20 Threaded Rods. LP1/MR1 Installation Guide 5 of 12 102-000030 - IG011519-A.0

Installation: Standard Suspension (Cont.) 5 Route Suspension Cable and Attach to Ceiling Route Suspension Cable through Suspension Bullet. Ball end should sit in Suspension Bullet. Screw Suspension Bullet to Ceiling Fitting. 8 Raise Fixture to Suspension Cables Raise fixture to Suspension Cables, and attach fixture by inserting Suspension Cable through Cable Grippers. 6" 6 Cut Suspension Cables to Desired Length 9 Adjust Suspension Cable Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. 7 Connecting Multiple Sections (If Necessary) Please see steps 28 through 33 for instructions on connecting multiple sections. 10 Connect Low Voltage Wiring Bring wiring and canopy assembly to Canopy J-box. Refer to page 11 and final/record drawing to make wiring connections. Strain relief connection. Ensure Power is OFF prior to connecting wiring. LP1/MR1 Installation Guide 6 of 12 102-000030 - IG011519-A.0

Installation: Standard Suspension (Cont.)! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. Installation: Central Axis Suspension (CAS) SAMPLE DRAWING 11A Mount Canopy Bracket to J-Box & Secure Canopy Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. CAUTION: Do not pinch wire connections. 13 Prepare Ceiling & Join Fixture Sections Follow steps 1-3 to prepare ceiling. (Install framing, Canopy J-Box, and Remote Driver J-Box, then install wiring from Remote Driver J-Box to Canopy J-Box). See steps 28-33 to connect fixture sections.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. 11B Combo Canopy Installation Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. Attach bullet (with cable) to canopy. CAUTION: Do not pinch wire connections. 14 Route Suspension Cable through Cable Coupler Route Suspension Cable through Cable Coupler. Ball end should sit in Coupler. Set aside. 12 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. 15 Install Canopy Bracket Install the threaded rod to the Canopy Bracket, then install Canopy Bracket to the Canopy J-Box. LP1/MR1 Installation Guide 7 of 12 102-000030 - IG011519-A.0

Installation: CAS (Cont.) SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. 16 Raise Fixture to J-Box & Connect Wiring Bring wiring and canopy assembly to Canopy J-box. Refer to page 11 and final/record drawing to make wiring connections. Strain relief connection. Ensure Power is OFF prior to connecting wiring. 19 Raise Fixture to Suspension Cables Raise fixture to suspension cables, and attach fixture by inserting suspension cable through cable grippers.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. 17 Secure Canopy Secure Canopy over J-Box with Cable Coupler. CAUTION: Do NOT pinch wires between J-Box/Canopy/ceiling surface. 20 Adjust Suspension Cable Length Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. 6" 18 Cut Suspension Cables to Desired Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. 21 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. LP1/MR1 Installation Guide 8 of 12 102-000030 - IG011519-A.0

Installation: Surface Mount (Back) SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. SAMPLE DRAWING 22 Install Mounting Brackets Follow steps 1-3 to prepare ceiling. (Install framing, Canopy J-Box, and Remote Driver J-Box, then install wiring from Remote Driver J-Box to Canopy J-Box). Install surface mount brackets directly to framing according to final/ record drawing. 25 Connect Low Voltage Wiring Connect low voltage wiring inside Remote J-Box and strain relief connection. Refer to page 11 and final/record drawing to make wiring connections. Ensure Power is OFF prior to connecting wiring. 23 Join Fixture Sections & Bring Fixture to Ceiling Follow steps 28-33 to join fixture sections. Bring fixture close to ceiling and align Ceiling Mount Brackets on fixture with Cleat Bosses. Ensure wiring location is correct. 26 Tighten Set Screws Tighten set screws using a 1/16 hex key. To Remote Driver 24 Feed Wiring to Remote Driver Feed wiring through the grommet on cover plate and route through ceiling to Remote Driver. 27 Turn Power On Turn breaker ON and ensure that fixture operates as intended and that there are no loose connections. LP1/MR1 Installation Guide 9 of 12 102-000030 - IG011519-A.0

Installation: Connecting Multiple Sections 28 Remove Cover Carefully remove metal cover to expose joiner sections. 31 Tighten Joiner Screws Tighten joiner screws, as shown, using a 5/64 Hex Key. Ensure each section is properly aligned, and that there are no gaps between sections. 29 Extend Joining Bar Loosen set screws on Joining Bar and extend, as shown. 32 Connect Wiring Between Sections Connect wiring quick-connects between sections. Match each color, as shown. NOTE: Color combinations may vary.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching cover.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching cover. 30 Align Sections & Join Align sections and join, as shown. CAUTION: Take care not to pinch wires. 33 Re-install Cover & Install Light Leak Band Re-install each metal cover, and install Light Leak Band at each joined section (over unilluminated sides), as shown. CAUTION: Do not pinch wires while reattaching! LP1/MR1 Installation Guide 10 of 12 102-000030 - IG011519-A.0

Wiring Diagrams Traditional On/Off L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground White Green Remote LED Driver J-Box DC Driver 1 LED + Driver 1 LED - Driver 2 LED + Brown Blue Yellow Canopy/Power Feed Driver 2 LED - Orange 0-10V Dimming L N AC 50/60Hz DIM- DIM+ Line Voltage (Hot) Line Voltage (Neutral) Ground 0-10VDC (Dim-) 0-10VDC (Dim+) White Green Grey Purple Remote LED Driver J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed DMX L Line Voltage (Hot) N AC 50/60Hz DMX In Shield DMX in - DMX in + Line Voltage (Neutral) Ground DMX in shield DMX in - DMX in + White Green Clear Red Remote LED Driver/Decoder J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed DMX Out Shield DMX out shield Clear DMX out - DMX out - DMX out + DMX out + White DALI L N AC 50/60Hz DATA + DATA - Line Voltage (Hot) Line Voltage (Neutral) Ground Data + Data - White Green Purple Grey Remote LED Driver/Decoder J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed Lutron LDE L N AC 50/60Hz E1 E2 Line Voltage (Hot) Line Voltage (Neutral) Ground E1 E2 White Green Purple Grey Remote LED Driver J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed LP1/MR1 Installation Guide 11 of 12 102-000030 - IG011519-A.0

Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure all wire connections are made. Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. Class 2 LED remote driver may be defective. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TEST. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. LP1/MR1 Installation Guide 12 of 12 102-000030 - IG011519-A.0