Liquid ring vacuum pumps with magnetic coupling

Similar documents
Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps

Liquid ring compressors

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Side Channel Pumps Self-priming, segmental type with verly low NPSH

Side Channel Pumps CEH CEH 1202/ /7 TECHNICAL DATA. Temperature: max. 180 C Casing pressure: PN 40

SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH

SEMA Side channel pumps PN 25 (40) Glandless because of magnetic drive

Side channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH

SIHI prime - Side Channel Pumps Self-priming, segmental type

Volute pumps for hot water

Side Channel Pumps Self-priming, segmental type

Volute pumps for hot water up to 230 C

Type ZEND. SIHI Model: ZEND / ZDND / ZHND Hot Water Transfer Pumps Product Reference Manual. Experience In Motion. FPD-xxxx

Volute pumps for hot water up to 207 C

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

The Modular System SIHI ISOchem

SIHI SuperNova. Volute casing pumps. Type ZLIC TECHNICAL DATA. 0B, 0C, 4B max. 120 C Casing pressure: PN 16 / PN 10 1)

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h. depending of the pump size and material execution

HEAVY DUTY HORIZONTAL, SEALLESS CENTRIFUGAL PUMP WITH PERMANENT MAGNET DRIVE SYSTEM, NO MECHANICAL SEAL ISO DIN 24256

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Chemical Magnetic Pumps with PTFE/PFA lining ATEX- and FDA compliant

VERTICAL IN-LINE PUMP

Volute pumps for heat carrier oils up to 350 C. SIHI SuperNova ZTND TECHNICAL DATA. Temperature: max. 350 C Casing pressure: PN 16

Norm-Centrifugal Pumps PN 10

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Chemical Motor Pump Unit BN

SIHI multi. Modular multistage pumps. Type MSL, MSM. Description. Construction. Applications. Technical Data. Options

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Axially split volute casing pumps. Applications. Bearings. Shaft seal. Operating data

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Screw Pumps Series SPF

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet

Data sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.

Sealless Magnetic Coupled Multistage Centrifugal Pumps with Priming Stage Type HZSM / HZSMB / HZSMR / HZSMA / HZSMAR

Verdermag Global Style series

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

Centrifugal Immersion Pumps

CENTRIFUGAL IMMERSION PUMPS

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Bearings. Shaft seal. Materials

Side Channel pumps Self-priming, segmental type

Standard plastic pump with magnetic coupling for use in the chemical industry ISO 2858/DIN EN 22858


Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

Ebara Submersible Sewage Pumps (Single Channel Impeller)

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

ABS submersible sewage pump AFP

Side channel pump PN 40 SRZ. self-priming, according to DIN EN 734. Technical description

PN 16 Volute Centrifugal Pumps (depending on materials up to PN 25) according to EN 22858/ISO 2858 and EN ISO 5199

TYPE PC Propeller Condensate Pumps

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

High-pressure pumps Series HP49

Screw Pump Twin Aggregates Series SPZ/M MagDrive

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

MMI L STAINLESS STEEL CENTRIFUGAL PUMPS Clean or slightly muddy liquids Corrosive fluids - Acids - Solvents OPERATING RANGES APPLICATIONS

3D drawings available at Kg GAS-NPT thread adapters available at page 1.117

Si Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

High-pressure pumps Series HP45

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Richter Sealless Chemical Magnetic Drive Pumps

barmesapumps.com VERTICAL MULTI-STAGE PUMP PERFORMANCE CURVE NOMENCLATURE B M V

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

High-Pressure Centrifugal Pumps

Screw Pumps Series EMTEC HIGH-TECH FOR EMULSION. 20 DQ axial branch with pipe thread. 140 D8.6 radial branch with SAE flange

PUMP. Submersible Sewage Pumps Type DSC4 FEATURES/BENEFITS

PRODUCT INFORMATION. Single-stage magnetically coupled pumps according to EN 22858; ISO 2858; ISO Model series MCN

PTB GLV. Vertical Centrifugal Pump

Volute Casing Pump additional sizes to those of ISO 2858/EN 22858

UTN-L / UTN-BL I frame

CRE20-08 A-F-A-E-HQQE 3x HZ

TRIVAC NT 16 and NT 25

Series PRODUCTS. self-priming Horizontal screw pump for non lubricating liquids. Water. Seawater. Heavy fuel oils. Bilge/Ballast pumps

Transfer Gear Pumps KF

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

NB80-160/161 A-F2-A-BQQE

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

CPS. Horizontal Split Case Centrifugal Pump

Centrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies

Supply plus delivery pressure must not exceed the admissible internal pump pressure.

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

Contents. Identification

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

Transcription:

Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps with magnetic coupling are displacement pumps of simple and robust design meeting high demands on tightness. Two liquid surrounded sleeve bearings of tungsten and silicon carbide bear the shaft axially and radial. The application of high-grade magnetic materials with high density of energy guarantees the transmission of the nominal torque and safety during the start-up phase and in case of overload. The modular magnetic system makes possible the optimal adaptation to different operating conditions. The main components of the pumps mostly are equal to those of the standard pumps, the connecting dimensions are identical. The material design can be adapted to the operating conditions. APPLICATION The vacuum pumps with magnetic coupling are suitable for handling and exhausting of nearly all dry and humid gases. They are applied wherever extremely high demands on tightness exist which cannot be met by pumps with shaft seal. NOTE The main fields of application are in the chemical and pharmaceutical industry where polluting, unhealthy or dangerous media are to be handled. Many different process vapours can be exhausted and the generated condensate possibly can be used as service liquid for the pump. For that purpose the service liquid, separated from the gas in all liquid separator, is run in a circuit. For the cooling of the system a heat exchanger is arranged in the circulating liquid line. GENERAL TECHNICAL DATA Pump type unit LPH 75320 LPH 75330 LPH 75340 Normal speed 50 Hz rpm 975 Power of the electric motor 1 IP 55 EEx e ll T3 Max. compression over pressure bar 0,6 Max. admissible pressure difference bar 1,5 kw kw Hydraulic test (over pressure) bar 3 Moment of the inertial of the rotating pump parts and of the water filling (without outer magnet) kg. m² 2,89 3,56 3,99 Sound pressure level at a suction of 80 mbar db (A) 79 Max. gas temperature dry saturated C C Service liquid max. admissible temperature C 50 max. viscosity mm²/s 90 max. density kg/m³ 1200 volume up to shaft liter 39 50 57 Max. flow resistance of the heat exchanger bar 0,2 Leakage mbar. l s < 1. 10-3 The combination of several limiting values is not admissible. 1) The dimensioning of the magnetic coupling and of the electric motor depends on the physical data of the service liquid and of the suction and discharge pressure of the pump. 37 40 45 46 100 50 55 64 VACUUM TECHNOLOGY LPH Magnet LII 6A 133.71242.52.01 E 05/2015

Material design LPH 75320, LPH 75330, LPH 75340 with magnetic coupling MATERIAL DESIGN Item COMPONENTS 0B 4B 10.60, 10.70 Casing 0.6025 1.4408 10.90, 10.91 Central body 1.0038 1.4581 13.70, 13.71, 13.72, 13.73 Guide disk, intermediate piece 0.6025 1.4408 11.30 Intermediate casing 1.0553 21.00 Shaft 1.4021 1.4571 23.50, 23.51 Vane wheel impeller 1.0553 33.00 Thrust bearing 1.4462 / silicon carbide 35.01 Bush 1.0553 / silicon carbide 1.4571/ silicon carbide 36.10 Bearing cover 1.0553 / 1.4462 / silicon carbide 1.4571 / 1.4462 / silicon carbide 52.90 Bushing tungsten carbide 54.50 Bush 1.4571 / silicon carbide 81.70 Isolation shroud 1.4571 / 2.4610 84.71 Inner magnet 1.4571 / Magnet 84.73 Magnetic bell 1.0553 / Magnet Sectional drawing LPH 75320, LPH 75330, LPH 75340 with magnetic coupling 2

Suction volume flow and power absorption LPH 75320, LPH 75330, LPH 75340 with magnetic coupling 1800 m³/h 1600 1400 suction volume flow 1200 1000 800 600 LPH 75340 LPH 75330 LPH 75320 400 200 speed: 975 rpm 0 10 40 60 80 100 200 400 mbar 1000 suction pressure power absorption 50 kw 40 30 20 10 LPH 75340 LPH 75330 LPH 75320 speed: 975 rpm 0 10 40 60 80100 200 400 mbar 1000 suction pressure The operating data are applicable under the following conditions: pumping medium: - dry air: 20 C - water vapour saturated air: 20 C service liquid: - water: 15 C Compression pressure 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the operating data 10% Max. fresh water need with lowest suction pressure 3

Dimension table LPH 75320, LPH 75330, LPH 75340 with magnetic coupling N 1 = gas-inlet DN 100 N 2 = gas-outlet DN 100 u B = connection for service liquid G 1¼ u c = connection for protection against cavitation G 3 /8 u e = drain connection G ¼ u l = connection for vent cock G 1½ u m = connection for pressure gauge G 3 /8 u m1 = connection for drain valve G ½ u se = connection for dirt drain G ½ u t = connection for temperature monitoring M12x1 a m 1 m 2 o 3 abt. kg LPH 75320 541 701 621 1570 780 LPH 75330 691 851 771 1720 870 LPH 75340 791 951 871 1820 930 flange connections to DIN 2501 PN 10 DN 100 k 180 D 220 number x d2 8 x 18 4

Arrangement drawing LPH 75320, LPH 75330, LPH 75340 with magnetic coupling N 1 = gas-inlet DN 100 N 2 = gas-outlet DN 150 u A = connection for liquid drain DN 80 u c = connection for protection against cavitation G 3 /8 u c1 = connection for protection against cavitation G 3 /8 u e1 = drain connection DN 25 u F = connection for fresh liquid DN 50 u fl = connection for liquid level indicator G ½ u pi = connection for pressure gauge G ¼ u t = connection for temperature monitoring M12x1 u ti = connection for thermometer G ½ electric motor 50 Hz pump + motor + as above + XBp + size kw a e 1 l l 1 l 2 m v o 1 * o 2 * coupling + base frame XCk + pipelines IP 55 EEx e ll T3 abt. kg abt. kg LPH 250 M 37-541 530 305 930 2503 1790 1930 75320 280 S - 40 750 2800 886 275 1044 2617 1950 2090 LPH 280 S 45-691 1005 2728 1990 2130 75330 280 M - 46 380 155 1095 2818 2075 2215 LPH 280 M 55-791 850 3000 986 225 1005 2828 2090 2230 75340 315 S - 64 1220 3043 2420 2560 flange connection to DIN 2501 PN 10 DN 25 50 80 100 150 k 85 125 160 180 240 D 115 165 200 220 285 number x d 2 4 x 14 4 x 18 8 x 18 8 x 18 8 x 22 * Dimensions and position of the connection box dependent on motor make 5

Fresh water requirements in [m³/h] dependent on suction pressure, speed, mode of operation and difference in temperature suction pressure[mbar] 33 120 200 400 KB KB KB KB pump type speed difference in FB difference in FB difference in FB difference in [rpm] 10 5 2 10 5 2 10 5 2 10 5 2 75320 1,90 3,15 5,15 1,90 3,05 4,85 1,90 3,00 4,55 1,60 2,30 3,10 LPH 75330 975 2,35 3,70 5,70 9 2,35 3,65 5,40 8 2,35 3,50 5,00 7 1,90 2,55 3,25 4 75340 2,60 4,00 6,00 2,60 3,90 5,65 2,55 3,75 5,20 2,00 2,70 3,35 FB = fresh liquid requirements KB = combined liquid service water 10 C, 5 C, 2 C warmer than the fresh water. FB Data regarding the pump size - order hints series + size A F hydraulics + bearings hydraulic A two grease lubricated antifriction bearings 5 A M N P shaft sealing + magnetic coupling 36-pole magnet glandless with isolation shroud torque of the magnetic coupling 1) 75320 5AM 0B 4B material design main parts GG without non-ferrous metal main parts Cr Ni Mo-cast steel casing seal 4 soft Teflon LPH 75330 AF 5AN alternative 0B, 4B 4 75340 5AP 1) The dimensioning of the magnetic coupling and of the electric motor depends on the physical data of the service liquid and of the suction and discharge pressure of the pump. In case of deviation from standard, please request further information and give details of your problem. Motor selection table delivery with motor IMB3; 50 Hz; 400 V ; 975 rpm motor protection IP 55 motor protection EEx e ll T3 power size designation power size designation LPH 75320 37 kw 250 M BC 40 kw 280 S CL LPH 75330 45 kw 280 S CC 46 kw 280 M DL LPH 75340 55 kw 280 M DC 64 kw 315 S EL Example for ordering: The construction size LPH 75330 AF 5AN 4B 4 with 45 kw three-phase motor (IMB3; 50 Hz; 400 V ) 975 rpm has the complete order number LPH 75330 AF 5AN 4B 4 CC If motors with other voltage or frequency are required a special information should be given. On delivery the point ( ) in the fourth place of the type code is replaced by a letter in the factory. 6

Accessories LPH 75320, LPH 75330, LPH 75340 with magnetic coupling recommended accessories LPH 75320 LPH 75330 LPH 75340 Upright liquid separator type / XBp 2311 / 96 kg material design 130 / galvanized 35 000 568 35 000 569 service liquid line material design 072 / St 37-0 cavitation protection line material design 072 / St 37-0 discharge line (bend) material design 072 / St 37-0 35 003 231 35 003 232 Sterling SIHI ball type non-return valve type XCk 100 material design 767 / 0.6025+NBR 43 016 898 / 16,0 kg 784 / 1.4408+PTFE / 43 029 322 / 17,5 kg Motor IP 55 size power 250 M 37 kw 410 kg 280 S 45 kw 540 kg 280 M 55 kw 580 kg EEx e ll T3 Coupling for motor IP 55 pump side motor side for motor EEx e ll T3 pump side motor side Contact safety device material design 076 / steel 345 / 2.0321 size power type / type / 280 S 40 kw 570 kg A 180 / 14 kg 43 035 527 43 034 392 ADS 194 / 17,5 kg 43 040 600 43 038 678 35 004 816 35 004 817 280 M 46 kw 625 kg A 180 / 14 kg 43 035 527 43 021 495 315 S 64 kw 910 kg ADS 218 / 24 kg 43 040 602 43 040 603 35 004 800 35 004 801 Base frame, abt. 500 kg 550 kg material design 081 / 1.0254 Base support for motor size 250 003 / 0.6025 8x 43 041 080 / 8x2,3 kg for motor size 280 003 / 0.6025 8x 43 041 077 / 8x1,3 kg for motor size 315 081 / steel 4x 49 064 175 / 4x 0,6 kg Resistance thermometer type PT 100-EEx i 43 039 552 lengthening piece M12x1-G ½ material design 20 000 532 Smooth starter type / Any changes in the interest of the technical development are reserved. Sterling SIHI GmbH Lindenstraße 170, D-25524 Itzehoe, Germany, Telephone +49 (0) 48 21 / 7 71-01, Fax +49 (0) 48 21 / 7 71-274 7