Online data sheet FLOWSIC100 VOLUME FLOW MESURING DEVICES
VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type FLOWSIC100 Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories www.sick.com/flowsic100 Product description The product family FLOWSIC100 was designed for emission monitoring tasks. The "H" versions are suitable for stacks with large diameters and applications with high dust content. The "M" versions are especially suited for stacks with medium diameter. The ultrasonic transducers of the "PR" probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The "C" versions have an innovative internal cooling and are suitable for gas temperatures up to 450 C. The purged "Px" versions are used for gases with high concentrations of sticky or wet dust. Rugged titanium transducers are standard and suitable under difficult conditions. The measuring system consists of 2 sender/receiver units or a measuring probe and a MCU control unit. The MCU is used for input and output of signals, for calculation of volume flow to reference conditions (standardization) as well as user-friendly LCD interface. t a glance Rugged titanium converters for long service life Corrosion-resistant material for use with aggressive gases (option) Integrated measurement via duct diameter for types H, M, and S Probe version PR for cost-saving, single-sided installation in duct utomated operational check with zero and reference point test Your benefits Reliable flow measurement for ducts with small up to very large diameters High durability of the device Minimum operating and maintenance costs ccurate measuring results under difficult measuring conditions Measurement without pressure loss, therefore no influences on the process User-friendly operation via SOPS ET software Reliable function monitoring due to enhanced diagnosis No purge air required for applications with gas temperatures up to 260 C 2 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
VOLUME FLOW MESURING DEVICES Fields of application Continuous emission measurement during power generation Emission monitoring in waste incineration plants Emission measurement in the processing industry (cement, iron and steel, glass) Emission monitoring in the chemical and hydrocarbon processing (HPI) industry Emission monitoring in the paper and textiles industry Flow measurements and process control in e. g., heating and ventilation systems Detailed technical data FLOWSIC100 system Measured values Performance-tested measurands Measurement principle Measuring ranges Certified measuring ranges Repeatability ccuracy Diagnostics functions mbient temperature Gas velocity Gas velocity Volumetric flow, a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature Gas velocity Ultrasonic transit time difference measurement 0... ± 40 m/s 0... 20 m/s / 0... 40 m/s For v < 2 m/s: ± 0.02 m/s For v > 2 m/s: ± 1 % ± 0.1 m/s Depending on application utomatic check cycle for zero and span point Extended device diagnosis via SOPS ET software 40 C... +60 C Storage temperature 40 C... +70 C Conformities Electrical safety Enclosure rating 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27.BImSchV 30. BImSchV T-Luft (Prevention of ir Pollution) EN 15267 EN 14181 EN 16911-2 MCERTS GOST CE IP 65 FLOWSIC100 M 40 C... +260 C 0.15 m... 3.4 m 1 g/m³ 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 3
VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T Depending on measuring path and gas temperature FLOWSIC100 H 40 W 2 x FLSE100-M sender/receiver unit 1 x MCU-N control unit 40 C... +260 C 1.4 m... 13 m FLOWSIC100 PR 100 g/m³ Depending on measuring path and gas temperature; for dry, non-sticky dust 40 W 2 x FLSE100-H sender/receiver unit 1 x MCU-N control unit 40 C... +260 C 0.4 m Mounting Installation angle 45 FLOWSIC100 S 1 g/m³ Depending on measuring path and gas temperature 40 W 1 x FLSE100-PR sender/receiver unit 1 x MCU-N control unit 1 x Connection cable 1 x flange with tube 40 C... +150 C 4 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
VOLUME FLOW MESURING DEVICES 0.15 m... 1.7 m 1 g/m³ Depending on measuring path and gas temperature FLOWSIC100 M-C 40 W 2 x FLSE100-S sender/receiver unit 1 x MCU-N control unit 40 C... +450 C 0.15 m... 3.4 m 1 g/m³ Depending on measuring path and gas temperature FLOWSIC100 H-C 75 W 2 x FLSE100-MC sender/receiver unit 1 x MCU-P control unit 2 x purge air hose 40 C... +450 C 1.4 m... 11.3 m 100 g/m³ Depending on measuring path and gas temperature; for dry, non-sticky dust 75 W 2 x FLSE100-HC sender/receiver unit 1 x MCU-P control unit 2 x purge air hose 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 5
VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T FLOWSIC100 PM 40 C... +450 C 0.35 m... 2.5 m 1 g/m³ Depending on measuring path and gas temperature FLOWSIC100 PH 40 W 2 x FLSE100-PM sender/receiver unit 1 x MCU-N control unit 2 x purge air hose 1 x purge air unit 40 C... +450 C 0.7 m... 8.7 m 100 g/m³ Depending on measuring path and gas temperature FLOWSIC100 PH-S 40 W 2 x FLSE100-PH sender/receiver unit 1 x MCU-N control unit 2 x purge air hose 1 x purge air unit 40 C... +450 C 1.4 m... 11.3 m 100 g/m³ Depending on measuring path and gas temperature 6 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
VOLUME FLOW MESURING DEVICES MCU-N control unit Description mbient temperature Enclosure rating nalog outputs nalog inputs Digital outputs Digital inputs Interfaces Bus protocol Indication Operation Dimensions (W x H x D) Weight Options Voltage Frequency 40 W 2 x FLSE100-PHS sender/receiver unit 1 x MCU-N control unit 2 x purge air hose 1 x purge air unit Compulsory control and evaluation unit for volume flow measuring devices without internal cooling 40 C... +60 C IP 65 1 output: 0/2/4... 20 m, 750 Ω Electrically isolated, up to five outputs when add-on modules are used (option) 2 inputs: 0... 20 m Up to four outputs when using additional modules (option) 5 relay outputs (change-over contacts), potential-free: 48 V, 1 Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle" 4 potential-free contacts USB 1.1 (virtual COM port; service interface) RS-232 (via clamp terminal; service interface) RS-485 (for connection of sender/receiver unit(s)) Ethernet TCP/IP (via optional interface module) Modbus (via optional interface module) Modbus TCP (via optional interface module) PROFIBUS DP (via optional interface module) LC display (option) Status LEDs: "Power", "Maintenance" and "Failure" Via LC-display (option) or software SOPS ET 210 mm x 340 mm x 120 mm 3.7 kg 90... 250 V Version with 24 V DC available as an option 47... 63 Hz 15 W Interface module(s) I/O module(s) LC display 19 -type 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 7
VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T MCU-P control unit Description mbient temperature Enclosure rating nalog outputs nalog inputs Digital outputs Digital inputs Interfaces Bus protocol Indication Operation Dimensions (W x H x D) Weight uxiliary connections Options Voltage Frequency SLV4-2 purge air unit, 2BH1300, 3-ph Description Purge air quantity Diagnostics functions mbient temperature Enclosure rating Compulsory control and evaluation unit with integrated cooling air unit, for volume flow measuring devices with internal cooling 40 C... +45 C Intake temperatures for purge air IP 54 1 output: 0/2/4... 20 m, 750 Ω Electrically isolated, up to five outputs when add-on modules are used (option) 2 inputs: 0... 20 m Not electrically isolated; additional inputs if using I/O modules (option) 5 relay outputs (change-over contacts), potential-free: 48 V, 1 Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle" 4 potential-free contacts USB 1.1 (virtual COM port; service interface) RS-232 (via clamp terminal; service interface) RS-485 (for connection of sender/receiver unit(s)) Ethernet TCP/IP (via optional interface module) Modbus (via optional interface module) Modbus TCP (via optional interface module) PROFIBUS DP (via optional interface module) LC display (option) Status LEDs: "Power", "Maintenance" and "Failure" Via LC-display (option) or software SOPS ET 300 mm x 455 mm x 220 mm 13.5 kg 90... 250 V Version with 24 V DC available as an option 47... 63 Hz 70 W Purge air Interface module(s) I/O module(s) LC display 19 -type Obligatory purge air unit for purged volume flow measuring devices 48 m³/h Low pressure controller 20 C... +40 C IP 54 8 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
VOLUME FLOW MESURING DEVICES Dimensions (W x H x D) Weight uxiliary connections Integrated components 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg Purge air: 40 mm 2-step air filter, type Europiclon, dust capacity 200 g Dimensional drawings (Dimensions in mm (inch)) FLSE100-H sender/receiver unit 60 (2.36) 142 (5.59) 200/350/550/750 (7.87/13.78/21.65/29.53) Ø 100 (3.94) Ø 60 (2.36) Ø 125 (4-92) FLSE100-HC sender/receiver unit 60 (2.36) 151 (5.94) 350/550 (13.78/21.65) Ø 100 (3.94) Ø 60 (2.36) Ø 125 (4.92) Ø 25 (0.98) FLSE100-M sender/receiver unit 60 (2.36) 157 (6.18) 200/350/550 (7.87/13.78/21.65) Ø 75 (2.95) Ø 35 (1.38) Ø 100 (3,94) 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 9
VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T FLSE100-MC sender/receiver unit 60 (2.36) 182 (7.17) 350/500 (13.78/21.65) Ø 25 (0.98) FLSE100-PHS sender/receiver unit 60 (2.36) 151 (5.94) 350/550/750 (13.78/21.65/29.53) Ø 40 (1.57) FLSE100-PM and FLSE100-PH sender/receiver unit 60 (2.36) 140 (5.51) 200/350/550/750 (7.87/13.78/21.65/29.53) Ø 40 (1.57) FLSE100-PR sender/receiver unit 60 (2.36) 140 (5.51) 350/550/750 506.5 (19.94) (13.78/21.65/29.53) Ø 60 (2.36) 270... 280 (10.63... 11.02) Ø 60 (2.36) Ø 35 (1.38) Ø 76 (2.99) Ø 210 (8.27) Ø 100 (3.94) Ø 125 (4.92) Ø 125 (4.92) Ø 170 (6.69) Ø 75 (2.95) Ø 100 (3.94) Ø 100 (3.94) 10 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
Meas FLOWSIC100 VOLUME FLOW MESURING DEVICES FLSE100-S sender/receiver unit 70.5 (2.78) 125/200/350 (4.92/7.87/13.78) Ø 75 (2.95) Ø 44.5 (1.75) Ø 28 (1.10) Ø 100 (3.94) FLSE100-SD sender/receiver unit 60 (2.36) 157 (6.18) 125/200/350 (4.92/7.87/13.78) Ø 75 (2.95) Ø 28 (1.10) Ø 100 (3.94) MCU-N control unit; wall-mounting enclosure, compact version (for non-hazardous areas only) 210 (8.27) 160 (6.30) 340 (13.39) 320 (12.60) 300 (11.81) 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 11
D1 Meas FLOWSIC100 VOLUME FLOW MESURING DEVICES B C D E F MCU-P control unit; wall-mounting enclosure, compact version (for non-hazardous areas only) 260 (10.24) Ø 8 (0.31) 455 (17.91) 420 (16.54) 400 (15.75) 300 (11.81) 220 (8.66) H I J K L M N O P Q R S T Mounting flange with tube L M8 D2 D3 D1 D2 D3 L Type FLSE100 48.3 75 100 113 S, SD 188, 338 S, SD, M 338, 538 M, MC 76.1 100 122 188 H, PM, PH 338 H, HC, PR, PM, PH 538 H, HC, PR, PM, PH 738 H, PR, PM, PH 114.3 170 210 338, 538, 738 PHS ll dimensions in mm 12 ULTRSONIC GS FLOW MESURING DEVICES SICK Online data sheet 2016-08-08 10:11:28 Subject to change without notice
VOLUME FLOW MESURING DEVICES SLV4-2 purge air unit, 2BH1300 Ø 10 (0.39) 550 (21.65) 470 (18.50) 40 (1.57) 40 470 (18.50) 128 (5.04) (1.57) 550 (21.65) 258 (10.16) 2016-08-08 10:11:28 Online data sheet Subject to change without notice ULTRSONIC GS FLOW MESURING DEVICES SICK 13
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, sia and North merica, system solutions are tested and optimized in accordance with customer specifications. ll this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations www.sick.com SICK G Waldkirch Germany www.sick.com