RIDE QUALITY All you need is a hoistway
1
Open the door to complete design freedom. No control room. No machine room. All you need is a hoistway. Otis knows that it s not just any building it s your building. With the Gen2 system, we re-examined every aspect of the elevator from design and installation to operation and maintenance. The result is a system that moves elevator innovation to a new level, supporting your design vision in a way that only Otis can. Otis Gen2 Delivers: Self-contained system Green technology Smoothest ride Minimal jobsite coordination Proven reliability 2
RIDE Self-contained QUALITY system Gen2 redefined the elevator with breakthrough belt technology. 1 2 Conventional geared elevator Conventional machineroomless elevator Conventional geared elevator systems require a rooftop machine room to house the machine, governor and controller. New advances in hoisting technology eliminate the need for a machine room. But these systems still require a separate room for the elevator control system. INTELLIGENT ENGINEERING Otis applied the strength of its worldwide engineering resources to redefine the elevator system and set a new benchmark for design and performance. A smarter way to hoist compact gearless machine 3 Patented, coated-steel belts have a significantly smaller bending radius than wire rope. This enables a compact gearless machine. Flexible belts allow a smaller sheave, creating a machine that is 70 percent smaller and up to 50 percent more efficient than conventional geared machines.
The revolution continues. 3 gen2 elevator With Gen2, all you need is a hoistway. The controller is so compact it fits inside the wall of the top elevator landing. You are no longer required to plan for extra room for elevator components. Compact design and integrated components provide: Greater architectural design freedom Space-saving configuration for more rentable space Less moving parts for greater durability and reliability Minimal jobsite coordination Lowest Overhead Otis Competitor Shallowest Pit compact controller The Gen2 system controller is compact enough to fit inside the wall of the top elevator landing. inspection & Test panel Most necessary test and maintenance features are concealed behind a panel in the elevator entrance. smallest hoistway Gen2 leads the industry with the shallowest pit and lowest overhead, fitting into most hydraulic hoistways. 4
green technology Innovation meets sustainability. Otis is leading the industry with The Way to Green. It begins with green thinking on a global scale. We encourage and enable our more than 60,000 employees worldwide to address the future positively and proactively. It is all a part of our end-to-end commitment to incorporating environmental awareness into everything we do. The Gen2 system with its state-of-the-art energy-efficiency is a result of this thinking. No Lubrication The Gen2 machine and coated steel belts require no additional lubrication, eliminating the need for storage, cleanup and disposal of hazardous waste. Clean Manufacturing We select all components for optimal performance and minimal environmental impact. Gen2 elevators use low VOC paints, safer adhesives, and we recycle nearly 97% of our industrial waste. maximized efficiency The Gen2 system combined with our ReGen drive, LED lighting and automatic sleep mode maximizes energy efficiency. Total energy consumption (kwh/yr) 5000 4000 3000 2000 1000 Hydraulic system Geared system Gearless system Car Lighting Control Systems Machine + Drive Based on 2500 lb at 150 ft/min, 8 stops and 200,000 starts/yr 5
Green Technology. Standard on the Gen2 system. Because being green is not optional. Uses Energy With the Otis ReGen drive: Energy created by your elevator is captured by the ReGen drive and is put to use it s fed into your building s electrical grid. Creates Energy Energy is captured and used. Regenerative technology Our ReGen Drive, now standard on the Gen2 System, puts electricity back into your building s grid by capturing normally wasted energy. Thanks to low harmonic distortion, this recycled energy provides clean power minimizing impact to your buildings electrical system. All this helps make the Gen2 system up to 75% more efficient than conventional systems. And from an energy consumption standpoint, the Gen2 system uses up to 40% less energy than non-regenerative machine-roomless systems. Efficient LED Lighting Sleep Mode LED illumination, standard on the Gen2 system, reduces energy consumption and lasts up to 10 times longer than conventional fluorescent lamps. Lights and fan are shut down when there s no demand, making the LED lighting up to 80% more efficient than conventional lighting. The system seamlessly springs back to life with the press of a call button. 6
Smoothest Ride A ride so smooth, you ll notice. Or maybe you won t. By taking an in-depth look at all sources of noise and vibration, Otis engineers designed the Gen2 system with passenger and tenant comfort in mind. The Gen2 system s ride quality is so smooth and quiet that passengers often don t notice it at all. Smooth Operation The Gen2 system s method of hoisting - coated-steel belts - eliminates the metal-on-metal contact of steel ropes and sheaves used by traditional systems. The result is a ride experience with noticeably less vibration and noise. Industry Comparison Careful component design and selection enabled Otis to engineer a remarkably smooth and quiet elevator. This means a more comfortable passenger experience as well as quiet operation that is critical to those tenants located near the elevator system. 50 25 20 Vertical Vibration [milli-g] 45 28 12 Horizontal Vibration [milli-g] 75 65 Car Noise [dba] 55 Industry hydraulic system Industry geared system Gen2 machine-roomless 7
MINIMAL JOBSITE COORDINATION Efficient. Seamless. Minimal impact on the jobsite. With a short lead time and all major components located inside the hoistway, the Gen2 system allows for more flexibility and reduced cost. THE INDUSTRY S SHORTEST LEAD TIME Coordinating a construction project is complex. If something changes and the jobsite is not ready for the elevator when it arrives, you ll likely have to pay costly storage and remobilization fees. The Gen2 system has an industry-leading lead time of six weeks, allowing you the flexibility to more accurately plan your project. Order is placed Gen2 6 weeks up to 50% less time Industry System 10 to 12 weeks Time to elevator delivery SAVE CONSTRUCTION TIME AND COST The Gen2 system doesn t require a control room to be built, saving time and material cost on the jobsite. And because its hall call buttons are mounted in the door jamb, even more time is saved there s no longer a need to coordinate with numerous trades on the jobsite. 8
proven reliability Industry-leading service that only Otis can provide. Otis is committed to ensuring optimal equipment performance throughout each product s lifecycle. Innovative technologies let Otis engineers precisely identify or anticipate possible issues. And when our mechanics arrive at customer sites, they are prepared to make repairs quickly and efficiently. Pulse The Pulse system provides safety and peace of mind with 24/7 monitoring of the Gen2 s flat coated-steel belts. It provides advance notice of belt wear by detecting the slightest weakness. OMMS The Otis Maintenance Management System (OMMS) is a predictive and preventative system, ensuring fewer service calls and less downtime than any other plan in the industry. We ll focus on your elevator so you can focus on your building. OTIS ELITE SM 9 Otis Elite service takes elevator service to a new level. Elite experts dedicated to your elevator provide industry-leading response time because they are able to remotely interact with your elevator. They re able to make changes to your elevator and provided critical information with real-time status updates. Elite service provides guaranteed 15-minute response time, instant information and unprecedented control.
At Otis, reliability is the hallmark of exceptional design. Gen2 is the culmination of Otis commitment to perfecting elevator technology. With flexible coated-steel belts and lubrication-free, energy efficient components, Gen2 sets the benchmark for elevator design and performance. From our industry-leading safety record to our proven reliability, Gen2 is the traction elevator you can count on. 10
Gen2 Specifications F E B G C J I K Travel height maximum 80 100 Maximum stops 10 13 D H A Speed (ft/min) 150 200 M G L Dimensions Rated lbs. 2100 2500 3000 3500 Passenger Capacity (USA/Canada) 13/12 16/15 20/18 23/21 Car 1 A Interior Width 5 8-5 16 6 5-9 16 B Interior depth 2 4 3-9 16 5 0-3 16 5 5-9 16 C Cab height 3 7-9 D Car door width 3-0 3-6 Important: To assist in your planning, we recommend that you call your Otis representative at the beginning of the project. Hoistway E Single width 7-7 8-4 in seismic zones 7-9 8-6 F Double width 15-6 17-0 in seismic zones 15-10 17-4 G Depth 4 5-9 6-4 6-11 in seismic zones 5-9 6-4 6-11 H Rough opening width 5-2 I Rough opening height 7-10 J Clear opening height 7-0 K Clear overhead to safety beam 5 Min 6 12-7 Max 14-7 L Min pit depth 7 4-0 / 5-0 Control Closet/Room 8 (optional) M Control closet simplex H x 3-10 Control room simplex H x 5-9 Control room simplex H x 7-6 1. Interior dimensions may vary depending on interior finishes. 2. For systems with front and rear openings, add 1 4 to depth dimension. 3. Clear cab height varies by ceiling type and floor recess. 4. For systems with front and rear openings, add 6-1 4 to 2100, 2500 and 3500 lb 7-7 8 to 3000 lb. 5. Allow a minimum of 4" between top of safety beam and top of hoistway. 6. In seismic areas, overhead = 12'-11". 7. Some locations require a 5'-0" pit, contact your local Otis sales representative for details. 8. Please consult your local Otis representative regarding smaller dimensions. 11
G F E B H C K J L Travel height maximum 131 Maximum stops 15 PLAN D I A SECTION Speed (ft/min) 350 N H M Dimensions Rated lbs. 2100 2500 3000 3500 4000 Passenger Capacity 13/12 16/15 20/18 23/21 27/25 Car A Interior width 5-8 6-8 7-8 B Interior depth 1 4-3 4-3 4-8 7 8 5-4 13 16 5-4 13 16 C Interior height 8-0 (Optional 10 ) D Car door width 3-0 3-6 4-0 Important: To assist in your planning, we recommend that you call your Otis representative at the beginning of the project. Hoistway E Width Single hoistway 7-6 8-6 8-8 8-8 9-8 In seismic zones 7-8 8-8 8-8 8-8 9-8 F Double hoistway 15-4 17-4 17-8 17-8 19-8 In seismic zones 15-8 17-8 17-8 17-8 19-8 G Triple hoistway 23-2 26-2 26-8 26-8 29-8 In seismic zones 23-8 26-8 26-8 26-8 29-8 H Depth 2 5-9 5-9 6-3 6-11 6-11 In seismic zones 2 5-9 5-9 6-3 6-11 6-11 I Rough opening width 4-8 5-2 5-2 5-2 5-8 J Rough opening height 7'-10" (8-10 if 8 feet doors) K Clear opening height 7-0 (Optional 8-0 ) L Clear overhead for 8'-0"car 3 Minimum 13-2 (200 fpm) 14-6 (350 fpm) Maximum 15-2 (200 fpm) 16-6 (350 fpm) Clear overhead for 10'car 3 Minimum 15-2 (200 fpm) 16-6 (350 fpm) Maximum 17-2 (200 fpm) 18-6 (350 fpm) M Minimum pit depth 4 5-0 (200 fpm) 5-6 (350 fpm) Control Closet/Room 5 N Control closet simplex H x 3-10 Control room simplex H x 5-9 Control room duplex H x 7-6 1. For systems with front and rear openings, add 3 4 to depth dimension. 2. For system with front and rear opening, add 5 7 8 to 2100 and 2500 lb, add 5 3 4 to 3000, 3500, and 4000 lb. 4. Maximum pit depth is 10-4 with blocking supplied from factory. 5. Please consult your local Otis representative regarding smaller dimensions. 3. Allow a minimum of 4 between top of hoist beam and top of hoistway. 12
Gen2 Specifications G F E Travel height maximum 300 Maximum stops 28 PLAN D I A B H C K J L SECTION Speed (ft/min) 400, 450, 500 N H Buffer M PASSENGER ELEVATORS Front Opening Dimensions Front and Rear Opening Dimensions Rated lbs. 2500 3000 3500 4000 2500 3000 3500 4000 Passenger Capacity (USA/Canada) 16/15 20/18 23/21 27/25 16/15 20/18 23/21 27/25 Car 3 A Interior width 6'-8 5 16" 6'-8 5 16" 6'-8 5 16" 7'-8 5 16" 6'-8 5 16" 6'-8 5 16" 6'-8 5 16" 7'-8 5 16" B Interior depth 4'-3 1 8" 4'-9" 5'-5" 5'-5" 4'-3 3 4" 4'-9 5 8" 5'-5 5 8" 5'-5 5 8" C Interior height 8'-0" (Optional 9'-7") D Car door width 3'-6" 3'-6" 3'-6" 4'-0" 3'-6" 3'-6" 3'-6" 4'-0" Hoistway E Width 2 Single hoistway 8'-4" 8'-4" 8'-4" 9'-4" 9'-4" 9'-4" 9'-4" 10'-4" In seismic zones 8'-6" 8'-6" 8'-6" 9'-6" 9'-6" 9'-6" 9'-6" 10'-6" F Double hoistway 17'-0" 17'-0" 17'-0" 19'-0" 19'-0" 19'-0" 19'-0" 21'-0" In seismic zones 17'-4" 17'-4" 17'-4" 19'-4" 19'-4" 19'-4" 19'-4" 21'-4" G Triple hoistway 25'-8" 25'-8" 25'-8" 28'-8" 28'-8" 28'-8" 28'-8" 31'-8" In seismic zones 26'-2" 26'-2" 26'-2" 29'-2" 29'-2" 29'-2" 29'-2" 32'-2" H Depth 6'-6" 7'-0" 7'-8 1 2" 7'-8 1 2" 6'-2 7 8" 6'-8 3 4" 7'-4 3 4" 7'-4 3 4" In seismic zones 6'-6" 7'-0" 7'-8 1 2" 7'-8 1 2" 6'-2 7 8" 6'-8 3 4" 7'-4 3 4" 7'-4 3 4" I Rough opening width 5'-2" 5'-2" 5'-2" 5'-8" 5'-2" 5'-2" 5'-2" 5'-8" J Rough opening height 7'-10" (8-10 if 8-foot doors) K Clear opening height 7'-0" (Optional 8'-0") L Total overhead for 8'-0"car @ 400 ft/min 16'-0" @ 450 ft/min 16'-5" @ 500 ft/min 16'-10" Total overhead for 9'-7"car @ 400 ft/min 17'-7" @ 450 ft/min 18'-0" @ 500 ft/min 18'-5" M Minimum pit depth @ 400 ft/min 5'-8" @ 450 ft/min 6'-2" @ 500 ft/min 6'-9" Control Closet/Room 3 N Control closet simplex H x 3'-10" width Control room simplex H x 5'-9" width Control room duplex H x 7'-6" width H x 9'-11" H x 7'-6" width H x 9'-11" 1. Interior dimensions may vary depending on interior finishes. 2. For elevators with occupied space below, this dimension may change. Consult your local Otis representative for dimensions. 3. Please consult your local Otis representative regarding smaller dimensions. 13
G F E Travel height maximum 196 300 Maximum stops 24 28 PLAN D I A B H C K J L SECTION Speed (ft/min) 200 350, 400, 450, 500 N H Buffer M SERVICE ELEVATORS Front Opening Dimensions Front and Rear Opening Dimensions Rated lbs. 4000H 4500H 5000H 5000H 4000H 4500H 5000H 5000H AIA Passenger Capacity (USA/Canada) 27/25 30/28 33/31 33/31 27/25 30/28 33/31 33/31 Car 3 A Interior width 5'-8 5 16" 5'-8 5 16" 5'-11 5 16" 5'-8 5 16" 5'-8 5 16" 5'-8 5 16" 5'-11 5 16" 5'-8 5 16" B Interior depth 7'-5" 7'-11" 8'-6" 9'-0" 7'-5 5 8" 7'-11 5 8" 8'-6 5 8" 9'-0 9 16" C Interior height 8'-0" (Optional 9'-7") D Car door width 4'-0" 4'-0" 4'-6" 4'-0" 4'-0" 4'-0" 4'-6" 4'-0" Hoistway E Width 2 Single hoistway 8'-2" 8'-2" 8'-5" 8'-2" 8'-2" 8'-2" 8'-5" 8'-2" In seismic zones 8'-4" 8'-4" 8'-7" 8'-4" 8'-4" 8'-4" 8'-7" 8'-4" F Double hoistway 16'-8" 16'-8" 17'-2" 16'-8" 16'-8" 16'-8" 17'-2" 16'-8" In seismic zones 17'-0" 17'-0" 17'-6" 17'-0" 17'-0" 17'-0" 17'-6" 17'-0" G Triple hoistway 25'-2" 25'-2" 25'-11" 25'-2" 25'-2" 25'-2" 25'-11" 25'-2" In seismic zones 25'-8" 25'-8" 26'-5" 25'-8" 25'-8" 25'-8" 26'-5" 25'-8" H Depth 9'-0" 9'-6" 10'-1" 10'-7" 9'-10 5 8" 10'-4 5 8" 10'-11 5 8" 11'-5 9 16" In seismic zones 9'-0" 9'-6" 10'-1" 10'-7" 9'-10 5 8" 10'-4 5 8" 10'-11 5 8" 11'-5 9 16" I Rough opening width 5'-8 1/2" 5'-8 1/2" 6'-2 1/2" 5'-8 1 2" 5'-8 1 2" 5'-8 1 2" 6'-2 1 2" 5'-8 1 2" J Rough opening height 7'-10" (8-10 if 8-foot doors) K Clear opening height 7'-0" (Optional 8'-0") L Total overhead for 8'-0"car @ 200 ft/min 14'-9 3 16" @ 350 ft/min 15'-5 9 16" @ 400 ft/min 16'-0" @ 450 ft/min 16'-5" - - 16'-5" - - @ 500 ft/min 16'-10" - - - 16'-10" - - - Total overhead for 9'-7"car @ 200 ft/min 16'-4 3 16" @ 350 ft/min 17'-0 9 16" @ 400 ft/min 17'-7" @ 450 ft/min 18'-0" 18'-0" @ 500 ft/min 18'-5" - - - 18'-5" - - - M Minimum pit depth @ 200 ft/min 4'-11 1 4" @ 350 ft/min 5'-5 1 4" @ 400 ft/min 5'-8" @ 450 ft/min 6'-2" - - 6'-2" - - @ 500 ft/min 6'-9" - - - 6'-9" - - Control Closet/Room 3 N Control closet simplex H x 3'-10" width Control room simplex H x 5'-9" width Control room duplex H x 9'-11" width (for>350 fpm) 1. Interior dimensions may vary depending on interior finishes. 2. For elevators with occupied space below, this dimension may change. Consult your local Otis representative for dimensions. 3. Please consult your local Otis representative regarding smaller dimensions. 14
www.otis.com publication GEN2-NSAA-001(0711) colab Otis Elevator Company 2011. All Rights reserved