Daily output in May 32 m³

Similar documents
Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

SunSwitch setting requirements min. 15 % Daily output in average month 154 m³

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Water temperature: Dirt loss: Total dynamic head:

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

Yield Reduction Due to Shading:

4TCH Submersible Pumps. Installation and Operating Manual

Yield Reduction Due to Shading:

DIN W.-Nr AISI 304

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Company name: Created by: Phone:

NE (SE) Beam

Sunrise: 05:48 N (S) Beam

Results of annual simulation

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

Energy Produced by PV Array (AC):

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

W (W) Beam

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

Todae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW.

Vunivau, Bua Province Vanua Levu, Fiji Solar Home System Design. Luis A. Vega, Ph.D.

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

ANCR CRU Statistics February 2007 to December 2007

Naresuan University, Phitsanulok 65000, Thailand *Corresponding author ABSTRACT

Graph #1. Micro-Generation Generating Units in Alberta 20

Past Due. Account Charges. Contract Charges Security Deposit Due - Jun 09, , Customer Service. Jun 19, PAST DUE $1,693.

Balance from your previous bill $0.00 Meter # Basic Charge: 17 $ /day 3.23* Energy charge:¹ 2

Up and Down Months of the Stock Market

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

NJ Solar Market Update As of 6/30/15

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

RNG Mono. Monocrystalline Type 10/20/30/50/60/100/150/250W. Key Features High module conversion efficiency. Application. Linear Warranty.

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

PS4000 HR/C SOLAR-OPERATED SUBMERSIBLE PUMP SYSTEMS MANUAL FOR INSTALLATION, OPERATION, SERVICE. Sun. Water. Life.

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

DATASHEET PLECTRE - SOLAR CELL LIGHTING COLUMN

PROVA 1011 Solar System Analyzer

Smart community clustering for sharing local green energy. Yoshiki Yamagata, Hajime Seya and Sho Kuroda

115 KV/34.5KV SOLAR PLANT/SUBSTATION

Photovoltaic Modules Installation Manual for Australia

SunRay Triangular. SunRay Triangular comes with tailored Smart City solutions, and is an ideal energy provider for streets and highways.

PV Module Installation Manual

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

Local Market Update February 2013

NEW-TEK SCHMID R Company High-tech enterprise for the production of PV solar modules

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV

ANCR CRU Statistics Februa.. to December 2007

Large scale solar power plant in Nordic conditions. Antti Kosonen, Jero Ahola, Christian Breyer, Albert Albó

NJ Solar Market Update As of 2/29/16

NJ Solar Market Update

My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing?

Storage in the energy market

E-SERIES RESIDENTIAL SOLAR PANELS

Would you like to be free and enjoy electrical comforts just like at home?

University of Michigan Eco-Driving Index (EDI) Latest data: October 2017

Techno-Economic Design of 432 KW P Grid Interactive Rooftop SPV Power Plant at Delhi Technological University (DTU)

The low carbonization of Mobile communication s BTS (Base Transceiver Station) by the Introduction of TRIBRID system in Indonesia.

115 KV/34.5KV SOLAR PLANT/SUBSTATION

PDR Energy Baseline Alternative. Proposal for Discussion October 27, 2015

X-SERIES SOLAR PANELS

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

Solargis Report. Solar Resource Overview. Plataforma Solar de Almeria, Spain. 03 August Solargis s.r.o.

OPERATIONS TOTALS ,135 7,511 8,823 8,056 8,021 8,319 8,039 8,283 8,001 8,738 8,219 8,094 98,239

Available online at ScienceDirect. Energy Procedia 36 (2013 )

DELTA SOLAR LED LIGHTING

DRAFT. Total Month Average Point (MAP) A Massage 4/30/2014 8/1/2015 A CENTER E

Installation and Operations Manual

American Samoa Power Authority

Suntech Power Cutting-Edge Technology

Virginia Tech Research Center Arlington, Virginia, USA. PPT slides will be available at

User Manual Version: 1.4

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Climatography of the United States No

Presentation to the Customer Service, Operations and Safety Committee OPERATIONS PERFORMANCE INDICATORS

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

Production Part Approval - Material, Performance Test Results Discrete Semiconductor Component Qualification Plan

WinnCompanies Community Solar Photovoltaic to Benefit Affordable Housing Darien Crimmin Vice President of Energy & Sustainability

Climatography of the United States No

NEWS Release. U.S. Manufacturing Technology Orders. Year-to-date U.S. manufacturing technology orders up 4.1% over 2011

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program

Passenger Car and Light Commercial Vehicle Market Showed a Decrease of 59% in January 2019.

4 submersible pumps powered by renewable energy sources

Field Test Results of Green Roofs, Cool Roofs, and Conventional Roofs CNY Engineering Expo Oncenter, Syracuse, NY November 9, 2015

WIM #37 was operational for the entire month of September Volume was computed using all monthly data.

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

Eclipse Solar Suitcase

Design Criteria Data

Report energy requirements Ljusdal

Local Market Update 2012 Year In Review

Design Criteria Data

SASKATOON STATION

Warranty on production defects: 12 years WP YEARS WARRANTY. CLASS 1 CLASS 1 Reaction to fire according to the UNI 9177 UNI standard IEC 61215

Virginia Tech Research Center Arlington, Virginia, USA

INSTALLATION & OPERATION MANUAL

Transcription:

Parameter Location: Serbia, Novi Sad (45 North; 19 East) Total dynamic head: 50 m Required daily output: 30 m³; Sizing for May Motor cable: 55 m Dirt loss: 5.0 % Pipeline: - Water temperature: 20 C Products Quantity Details PS1800 HR-23-1 1 pc. Submersible pump system including controller, motor and pump end STC 245W 8 pc. 1,960 Wp; 4 x 2 modules; 45 tilted Motor cable 55 m 4 mm² 3-phase cable Accessories 1 set Well Probe, PV Disconnect 200V/20A Daily output in May 32 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av. Output [m³] Energy [kwh] 4.8 6.8 8.4 8.7 9.2 9.3 9.4 9.3 8.2 6.5 4.1 3.7 7.4 Irradiation [kwh/m²] 2.4 3.5 4.5 4.8 5.2 5.3 5.5 5.4 4.6 3.5 2.2 1.9 4.1 Rainfall [mm] 1.3 1.2 1.3 1.6 2.0 2.7 2.1 1.9 1.4 1.4 1.7 1.6 1.7 Ambient temp. [ C] 1 2 7 12 18 21 24 24 19 14 7 2 12 Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 Output [m³/h] Energy [kwh] 0.13 0.36 0.60 0.83 1.0 1.1 1.2 1.1 0.99 0.81 0.57 0.35 0.12 Irradiation [kwh/m²] 0.067 0.19 0.32 0.46 0.57 0.64 0.67 0.64 0.57 0.46 0.32 0.19 0.067 Ambient temp. [ C] 13 13 14 16 18 20 22 23 23 23 23 22 22 1/4

System characteristic Min. 800 W/m², 20 C Max./STC* PV generator Cell temperature [ C] 46 25 Temperature loss [%] 8.8 - Dirt loss [%] 5.0 - Pmax [Wp] 1,360 1,960 Vmp [V] 109 120 Imp [A] 12 16 Voc [V] 139 151 Isc [A] 13 17 Pout [W] 877 - Vout [V] 127 - Iout [A] 6.9 - Motor cable Power loss [%] 2.9 2.9 7.9 Pump system Motor power [W] 213 842 842 Motor voltage [V EC] 35 117 117 Motor current [A] 6.1 7.2 7.2 Motor speed [rpm] 940 3,275 3,275 Flow rate [m³/h] 0.45 3.6 3.6 Efficiency [%] 26 57 57 *STC: Standard test conditions for photovoltaic modules, 1000 W/m² solar iradiance, 25 C cell temperature 2/4

Wiring diagram 3/4

Layout H (Static head): T (Tilt angle): M (Motor cable): L (Pipeline): B (Drawdown): D (Pipeline inner diameter) Vertical height from the dynamic water level to the highest point of delivery. Angle between the PV generator pane and the horizontal pane. The cable between controller and pump unit. Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an equivalent length of pipeline. Lowering of water level depending on flow rate and recovery rate of the well. 4/4

Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the well dropped below the level of the well probe, the LORENTZ Controller will stop the pump and indicates Source Low LED. FEATURES Reliable dry run protection Simple to install Trouble free operation Corrosion-free Splicing kit included TECHNICAL DATA Max. operating temperature 55 C Enclosure class: IP68 Submersion depth: max 50 m Cable length: 1.5m Wire size: 2x 0.75mm² or AWG 19, waterproofed Mounted in vertical position STANDARDS Meets the requirements for CE DIMENSION/WEIGHT Packaging dimensions: 260 x 170 x 40 mm 10.3in x 6.7in x 1.6in Total weight: 0.1kg / 0.2lbs V130613 BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel +49 (0)4193 7548-0, Fax -29, Pictures may differ from actual products depending on local market requirements and regulations.

PV Disconnect 200V / 20A PV Disconnect to facilitate an easy Installation for PS 150 until PS 1800 FEATURES For quick installation without opening the Controller Cable conduit allows proper sealing of controller Extends the Controller terminals TECHNICAL DATA 200V DC / 20A Flexible conduit 1x 90cm STANDARDS Meets the requirements for CE DIMENSION/WEIGHT 300mm x 300mm x 150mm 11.8in x 11.8in x 5.9in Total weight: 6.8kg / 15lbs V130613 BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel +49 (0)4193 7548-0, Fax -29, Pictures may differ from actual products depending on local market requirements and regulations.